Skip to main content
Top
Published in: BMC Oral Health 1/2021

Open Access 01-12-2021 | Computed Tomography | Research article

Three-dimensional analysis of the root canal preparation with Reciproc Blue®, WaveOne Gold® and XP EndoShaper®: a new method in vivo

Authors: Javier Caviedes-Bucheli, Nestor Rios-Osorio, Diana Usme, Cristian Jimenez, Adriana Pinzon, Jorge Rincón, María M. Azuero-Holguin, Alvaro Zubizarreta-Macho, Jose F. Gomez-Sosa, Hugo R. Munoz

Published in: BMC Oral Health | Issue 1/2021

Login to get access

Abstract

Background

The purpose of this study was to evaluate the changes in canal volume after root canal preparation in vivo with 3 different single-file techniques (Reciproc-Blue®, WaveOne-Gold® and XP-EndoShaper®), with a new method using CBCT and 3D reconstruction.

Methods

In this prospective study, thirty human lower premolars from healthy patients were used, in which extraction was indicated for orthodontic reasons. All the teeth used were caries- and restoration-free with complete root development, without signs of periodontal disease or traumatic occlusion, and with only one straight canal (up to 25º curvature). Teeth were randomly divided into three different groups: Reciproc-Blue, WaveOne-Gold and XP-EndoShaper. CBCT scans before root canal preparation were used to create a 3D reconstruction with RHINOCEROS 5.0 software to assess the initial canal volume, and then compared with 3D reconstructions after canal preparation to measure the increase in canal volume. Student’s t test for paired data were used to determine statistically significant differences between the before and after canal volumes. Anova test was used to determine statistically significant differences in the percentage of canal volume increase between the groups and Tukey's post-hoc test were used to paired comparison.

Results

Reciproc-Blue showed the higher increase in canal volume, followed by WaveOne-Gold and XP-EndoShaper (p = 0.003). XP-EndoShaper did not show a statistically significant increase in canal volume after root canal preparation (p = 0.06).

Conclusion

With this model, Reciproc-Blue showed higher increase in root canal volume, followed by WaveOne-Gold, while XP-EndoShaper did not significantly increase root canal volume during preparation.
Literature
1.
go back to reference Burroughs JR, Bergeron BE, Roberts MD, Hagan JL, Himel VT. Shaping ability of three nickel-titanium endodontic file systems in simulated S-shaped root canals. J Endod. 2012;38:1618–21.CrossRef Burroughs JR, Bergeron BE, Roberts MD, Hagan JL, Himel VT. Shaping ability of three nickel-titanium endodontic file systems in simulated S-shaped root canals. J Endod. 2012;38:1618–21.CrossRef
2.
go back to reference Ponce EH, Vilar Fernández JA. The cemento-dentino-canal junction, the apical foramen, and the apical constriction: evaluation by optical microscopy. J Endod. 2003;29:214–9.CrossRef Ponce EH, Vilar Fernández JA. The cemento-dentino-canal junction, the apical foramen, and the apical constriction: evaluation by optical microscopy. J Endod. 2003;29:214–9.CrossRef
3.
go back to reference Lacerda MFLS, Marceliano-Alves MF, Pérez AR, Provenzano JC, Neves MAS, Pires FR, et al. Cleaning and shaping oval canals with 3 instrumentation systems: a correlative micro-computed tomographic and histologic study. J Endod. 2017;43:1878–84.CrossRef Lacerda MFLS, Marceliano-Alves MF, Pérez AR, Provenzano JC, Neves MAS, Pires FR, et al. Cleaning and shaping oval canals with 3 instrumentation systems: a correlative micro-computed tomographic and histologic study. J Endod. 2017;43:1878–84.CrossRef
4.
go back to reference Wei Z, Cui Z, Yan P, Jiang H. A comparison of the shaping ability of three nickel–titanium rotary instruments: a micro-computed tomography study via a contrast radiopaque technique in vitro. BMC Oral Health. 2017;17:39.CrossRef Wei Z, Cui Z, Yan P, Jiang H. A comparison of the shaping ability of three nickel–titanium rotary instruments: a micro-computed tomography study via a contrast radiopaque technique in vitro. BMC Oral Health. 2017;17:39.CrossRef
5.
go back to reference Paqué F, Balmer M, Attin T, Peters OA. Preparation of oval-shaped root canals in mandibular molars using nickel–titanium rotary instruments: a micro-computed tomography study. J Endod. 2010;36:703–7.CrossRef Paqué F, Balmer M, Attin T, Peters OA. Preparation of oval-shaped root canals in mandibular molars using nickel–titanium rotary instruments: a micro-computed tomography study. J Endod. 2010;36:703–7.CrossRef
6.
go back to reference Wu MK, Wesselink PR, Walton PR. Apical terminus location of root canal treatment procedures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000;89:99–103.CrossRef Wu MK, Wesselink PR, Walton PR. Apical terminus location of root canal treatment procedures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000;89:99–103.CrossRef
7.
go back to reference Manker A, Solanki M, Tripathi A, Jain ML. Biomechanical preparation in primary molars using manual and three NiTi instruments: a cone-beam-computed tomographic in vitro study. Eur Arch Paediatr Dent. 2020;21:203–13.CrossRef Manker A, Solanki M, Tripathi A, Jain ML. Biomechanical preparation in primary molars using manual and three NiTi instruments: a cone-beam-computed tomographic in vitro study. Eur Arch Paediatr Dent. 2020;21:203–13.CrossRef
8.
go back to reference Giuliani V, Di Nasso L, Pace R, Pagavino G. Shaping ability of waveone primary reciprocating files and ProTaper system used in continuous and reciprocating motion. J Endod. 2014;40:1468–71.CrossRef Giuliani V, Di Nasso L, Pace R, Pagavino G. Shaping ability of waveone primary reciprocating files and ProTaper system used in continuous and reciprocating motion. J Endod. 2014;40:1468–71.CrossRef
9.
go back to reference Thomas JP, Lynch M, Paurazas S, Askar M. Micro-computed tomographic evaluation of the shaping ability of WaveOne Gold, TRUShape, EdgeCoil, and XP-3D shaper endodontic files in single, oval-shaped canals: an in vitro study. J Endod. 2020;46:244–51.CrossRef Thomas JP, Lynch M, Paurazas S, Askar M. Micro-computed tomographic evaluation of the shaping ability of WaveOne Gold, TRUShape, EdgeCoil, and XP-3D shaper endodontic files in single, oval-shaped canals: an in vitro study. J Endod. 2020;46:244–51.CrossRef
10.
go back to reference Adıgüzel M, Capar ID. Comparison of cyclic fatigue resistance of WaveOne and WaveOne gold small, primary, and large instruments. J Endod. 2017;43:623–7.CrossRef Adıgüzel M, Capar ID. Comparison of cyclic fatigue resistance of WaveOne and WaveOne gold small, primary, and large instruments. J Endod. 2017;43:623–7.CrossRef
11.
go back to reference Keskin C, Inan U, Demiral M, Keleş A. Cyclic fatigue resistance of Reciproc Blue, Reciproc, and WaveOne Gold reciprocating instruments. J Endod. 2017;43:1360–3.CrossRef Keskin C, Inan U, Demiral M, Keleş A. Cyclic fatigue resistance of Reciproc Blue, Reciproc, and WaveOne Gold reciprocating instruments. J Endod. 2017;43:1360–3.CrossRef
12.
go back to reference Arıcan Öztürk B, Atav Ateş A, Fişekçioğlu E. Cone-beam computed tomographic analysis of shaping ability of XP-endo Shaper and ProTaper next in large root canals. J Endod. 2020;46(3):437–43.CrossRef Arıcan Öztürk B, Atav Ateş A, Fişekçioğlu E. Cone-beam computed tomographic analysis of shaping ability of XP-endo Shaper and ProTaper next in large root canals. J Endod. 2020;46(3):437–43.CrossRef
13.
go back to reference Chavda R, Mannocci F, Andiappan M, Patel S. Comparing the in vivo diagnostic accuracy of digital periapical radiography with cone-beam computed tomography for the detection of vertical root fracture. J Endod. 2014;40:1524–9.CrossRef Chavda R, Mannocci F, Andiappan M, Patel S. Comparing the in vivo diagnostic accuracy of digital periapical radiography with cone-beam computed tomography for the detection of vertical root fracture. J Endod. 2014;40:1524–9.CrossRef
14.
go back to reference Tyndall DA, Kohltfarber H. Application of cone beam volumetric tomography in endodontics. Aust Dent J. 2012;57:72–81.CrossRef Tyndall DA, Kohltfarber H. Application of cone beam volumetric tomography in endodontics. Aust Dent J. 2012;57:72–81.CrossRef
15.
go back to reference Chen H, Lowe AA, de Almeida FR, Wong M, Fleetham JA, Wang B. Three-dimensional computer-assisted study model analysis of long-term oral-appliance wear. Part 1: Methodology. Am J Orthod Dentofacial Ortho. 2008;134:393–407.CrossRef Chen H, Lowe AA, de Almeida FR, Wong M, Fleetham JA, Wang B. Three-dimensional computer-assisted study model analysis of long-term oral-appliance wear. Part 1: Methodology. Am J Orthod Dentofacial Ortho. 2008;134:393–407.CrossRef
17.
go back to reference Bradel S, Doniga-Crivat L, Besdo S, Lexow F, Fehr M, Lenarz T, et al. Innovative 3D model of the human middle ear in high resolution with a histological microgrinding method: a feasibility study and comparison with μCT. Int J Otolaryngol. 2017;2017:6753604.CrossRef Bradel S, Doniga-Crivat L, Besdo S, Lexow F, Fehr M, Lenarz T, et al. Innovative 3D model of the human middle ear in high resolution with a histological microgrinding method: a feasibility study and comparison with μCT. Int J Otolaryngol. 2017;2017:6753604.CrossRef
18.
go back to reference Amornvit P, Sanohkan S, Peampring C. Studying the optical 3D accuracy of intraoral scans: an in vitro study. J Healthc Eng. 2020;2020:5739312.CrossRef Amornvit P, Sanohkan S, Peampring C. Studying the optical 3D accuracy of intraoral scans: an in vitro study. J Healthc Eng. 2020;2020:5739312.CrossRef
19.
go back to reference Chakroun F, Colombo V, Lie Sam Foek D, Gallo LM, Feilzer A, Özcan M. Displacement of teeth without and with bonded fixed orthodontic retainers: 3D analysis using triangular target frames and optoelectronic motion tracking device. J Mech Behav Biomed Mater. 2018;85:175–80.CrossRef Chakroun F, Colombo V, Lie Sam Foek D, Gallo LM, Feilzer A, Özcan M. Displacement of teeth without and with bonded fixed orthodontic retainers: 3D analysis using triangular target frames and optoelectronic motion tracking device. J Mech Behav Biomed Mater. 2018;85:175–80.CrossRef
20.
go back to reference Verri FR, Okumura MHT, Lemos CAA, Almeida DAF, de Souza Batista VE, Cruz RS, et al. Three-dimensional finite element analysis of glass fiber and cast metal posts with different alloys for reconstruction of teeth without ferrule. J Med Eng Technol. 2017;41:644–51.CrossRef Verri FR, Okumura MHT, Lemos CAA, Almeida DAF, de Souza Batista VE, Cruz RS, et al. Three-dimensional finite element analysis of glass fiber and cast metal posts with different alloys for reconstruction of teeth without ferrule. J Med Eng Technol. 2017;41:644–51.CrossRef
21.
go back to reference Soares PV, Souza LV, Veríssimo C, Zeola LF, Pereira AG, Santos-Filho PC, et al. Effect of root morphology on biomechanical behaviour of premolars associated with abfraction lesions and different loading types. J Oral Rehabil. 2014;41:108–14.CrossRef Soares PV, Souza LV, Veríssimo C, Zeola LF, Pereira AG, Santos-Filho PC, et al. Effect of root morphology on biomechanical behaviour of premolars associated with abfraction lesions and different loading types. J Oral Rehabil. 2014;41:108–14.CrossRef
22.
go back to reference Patel S, Durack C, Abella F, Roig M, Shemesh H, Lambrechts P, Lemberg K. European Society of Endodontology position statement: the use of CBCT in endodontics. Int Endod J. 2014;47:502–4.CrossRef Patel S, Durack C, Abella F, Roig M, Shemesh H, Lambrechts P, Lemberg K. European Society of Endodontology position statement: the use of CBCT in endodontics. Int Endod J. 2014;47:502–4.CrossRef
23.
go back to reference Maeda M, Katsumata A, Ariji Y, Muramatsu A, Yoshida K, Goto S, et al. 3D-CT evaluation of facial asymmetry in patients with maxillofacial deformities. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006;102:382–90.CrossRef Maeda M, Katsumata A, Ariji Y, Muramatsu A, Yoshida K, Goto S, et al. 3D-CT evaluation of facial asymmetry in patients with maxillofacial deformities. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006;102:382–90.CrossRef
24.
go back to reference Plotino G, Giansiracusa Rubini A, Grande NM, Testarelli L, Gambarini G. Cutting efficiency of Reciproc and waveOne reciprocating instruments. J Endod. 2014;40:1228–30.CrossRef Plotino G, Giansiracusa Rubini A, Grande NM, Testarelli L, Gambarini G. Cutting efficiency of Reciproc and waveOne reciprocating instruments. J Endod. 2014;40:1228–30.CrossRef
25.
go back to reference Silva EJNL, Vieira VTL, Belladonna FG, Zuolo AS, Antunes HDS, Cavalcante DM, et al. Cyclic and torsional fatigue resistance of XP-endo Shaper and TRUShape instruments. J Endod. 2018;44:168–72.CrossRef Silva EJNL, Vieira VTL, Belladonna FG, Zuolo AS, Antunes HDS, Cavalcante DM, et al. Cyclic and torsional fatigue resistance of XP-endo Shaper and TRUShape instruments. J Endod. 2018;44:168–72.CrossRef
26.
go back to reference Moinzadeh A, De Bruyne M. Re: A micro-computed tomographic evaluation of apical root canal preparation using three instrumentation techniques. Int Endod J. 2010;43:451–2 (author reply 453).CrossRef Moinzadeh A, De Bruyne M. Re: A micro-computed tomographic evaluation of apical root canal preparation using three instrumentation techniques. Int Endod J. 2010;43:451–2 (author reply 453).CrossRef
27.
go back to reference Azim AA, Piasecki L, da Silva Neto UX, Cruz ATG, Azim KA. XP Shaper, a novel adaptive core rotary instrument: micro-computed tomographic analysis of its shaping abilities. J Endod. 2017;43:1532–8.CrossRef Azim AA, Piasecki L, da Silva Neto UX, Cruz ATG, Azim KA. XP Shaper, a novel adaptive core rotary instrument: micro-computed tomographic analysis of its shaping abilities. J Endod. 2017;43:1532–8.CrossRef
28.
go back to reference Rossi-Fedele G, Ahmed HM. Assessment of root canal filling removal effectiveness using micro-computed tomography: a systematic review. J Endod. 2017;43:520–6.CrossRef Rossi-Fedele G, Ahmed HM. Assessment of root canal filling removal effectiveness using micro-computed tomography: a systematic review. J Endod. 2017;43:520–6.CrossRef
29.
go back to reference Faggion CM Jr. Guidelines for reporting pre-clinical in vitro studies on dental materials. J Evid Based Dent Pract. 2012;12:182–9.CrossRef Faggion CM Jr. Guidelines for reporting pre-clinical in vitro studies on dental materials. J Evid Based Dent Pract. 2012;12:182–9.CrossRef
30.
go back to reference Cotton TP, Geisler TM, Holden DT, Schwartz SA, Schindler WG. Endodontic applications of cone-beam volumetric tomography. J Endod. 2007;33:1121–32.CrossRef Cotton TP, Geisler TM, Holden DT, Schwartz SA, Schindler WG. Endodontic applications of cone-beam volumetric tomography. J Endod. 2007;33:1121–32.CrossRef
31.
go back to reference Moraes SL, Pellizzer EP, Verri FR, Santiago JF Jr, Silva JV. Three-dimensional finite element analysis of stress distribution in retention screws of different crown-implant ratios. Comput Methods Biomech Biomed Engin. 2015;18:689–96.CrossRef Moraes SL, Pellizzer EP, Verri FR, Santiago JF Jr, Silva JV. Three-dimensional finite element analysis of stress distribution in retention screws of different crown-implant ratios. Comput Methods Biomech Biomed Engin. 2015;18:689–96.CrossRef
32.
go back to reference Shea BJ, Grimshaw JM, Wells GA, Boers M, Andersson N, Hamel C, et al. Development of AMSTAR: a measurement tool to assess the methodological quality of systematic reviews. BMC Med Res Methodol. 2007;7:10.CrossRef Shea BJ, Grimshaw JM, Wells GA, Boers M, Andersson N, Hamel C, et al. Development of AMSTAR: a measurement tool to assess the methodological quality of systematic reviews. BMC Med Res Methodol. 2007;7:10.CrossRef
33.
go back to reference Peters OA, Laib A, Göhring TN, Barbakow F. Changes in root canal geometry after preparation assessed by high-resolution computed tomography. J Endod. 2001;27:1–6.CrossRef Peters OA, Laib A, Göhring TN, Barbakow F. Changes in root canal geometry after preparation assessed by high-resolution computed tomography. J Endod. 2001;27:1–6.CrossRef
34.
go back to reference Özyürek T, Yılmaz K, Uslu G. Shaping ability of Reciproc, WaveOne GOLD, and HyFlex EDM single-file systems in simulated s-shaped canals. J Endod. 2017;43:805–9.CrossRef Özyürek T, Yılmaz K, Uslu G. Shaping ability of Reciproc, WaveOne GOLD, and HyFlex EDM single-file systems in simulated s-shaped canals. J Endod. 2017;43:805–9.CrossRef
Metadata
Title
Three-dimensional analysis of the root canal preparation with Reciproc Blue®, WaveOne Gold® and XP EndoShaper®: a new method in vivo
Authors
Javier Caviedes-Bucheli
Nestor Rios-Osorio
Diana Usme
Cristian Jimenez
Adriana Pinzon
Jorge Rincón
María M. Azuero-Holguin
Alvaro Zubizarreta-Macho
Jose F. Gomez-Sosa
Hugo R. Munoz
Publication date
01-12-2021
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2021
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-021-01450-1

Other articles of this Issue 1/2021

BMC Oral Health 1/2021 Go to the issue