Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2020

Open Access 01-12-2020 | Computed Tomography | Research article

The evaluation of the distance between the popliteus tendon and the lateral collateral ligament footprint and the implant in Total knee Arthroplasty using a 3-dimensional template

Authors: Akihito Takubo, Keinosuke Ryu, Takanori Iriuchishima, Masahiro Nagaoka, Yasuaki Tokuhashi, Shin Aizawa

Published in: BMC Musculoskeletal Disorders | Issue 1/2020

Login to get access

Abstract

Background

The popliteus tendon (PT) or lateral collateral ligament (LCL) stabilizes the postero-lateral aspects of the knees. When surgeons perform total knee arthroplasty (TKA), PT and LCL iatrogenic injuries are a risk because the femoral attachments are relatively close to the femoral bone resection area. The purpose of this study was to evaluate the distance between the PT or LCL footprint and the TKA implant using a 3D template system and to evaluate any significant differences according to the implant model.

Methods

Eighteen non-paired formalin fixed cadaveric lower limbs were used (average age: 80.3). Whole length lower limbs were resected from the pelvis. All the surrounding soft tissue except the PT, knee ligaments and meniscus were removed from the limb. Careful dissection of the PT and LCL was performed, and the femoral footprints were detected. Each footprint periphery was marked with a 1.5 mm K-wire. Computed tomography (CT) scanning of the whole lower limb was then performed. The CT data was analyzed with a 3D template system. This simulation models for TKA were the Journey II BCS and the Persona PS. The area of each footprint, and the length between the most distal and posterior point of the lateral femoral condyle and the edge of each footprint were measured. Matching the implant model to the CT image of the femur, the shortest length between each footprint and the bone resection area were calculated.

Results

PT and LCL footprint were detected in all knees. The area of the PT and LCL footprints was 38.7 ± 17.7 mm2 and 58.0 ± 24.6 mm2, respectively. The length between the most distal and posterior point of the lateral femoral condyle and the edge of the PT footprint was 10.3 ± 2.4 mm and 14.2 ± 2.8 mm, respectively. The length between most distal and most posterior point of the lateral femoral condyle and the edge of the LCL footprint was 16.3 ± 2.3 mm and 15.5 ± 3.3 mm, respectively. Under TKA simulation, the shortest length between the PT footprint and the femoral bone resection area for the Journey II BCS and the Persona PS was 4.3 ± 2.5 mm and 3.2 ± 2.9 mm, respectively. The shortest length between the LCL footprint and the femoral bone resection area for the Journey II BCS and the Persona PS was 7.2 ± 2.3 mm and 5.6 ± 2.1 mm, respectively. The PT attachment was damaged by the bone resection of the Journey II BCS and the Persona PS TKA in 3 and 9 knees, respectively.

Conclusion

The PT and LCL femoral attachments existed close to the femoral bone resection area of the TKA. To prevent postero-lateral instability in TKA, careful attention is needed to avoid damage to the PT and LCL during surgical procedures.
Literature
1.
go back to reference Aki T, Sugita T, Takahashi A, Aizawa T, Kamimura M, Sasaki A, Miyatake N, Itoi E. Femoral footprint of the popliteus tendon may be at the risk of damage during total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2017;25(12):3718–22.CrossRef Aki T, Sugita T, Takahashi A, Aizawa T, Kamimura M, Sasaki A, Miyatake N, Itoi E. Femoral footprint of the popliteus tendon may be at the risk of damage during total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2017;25(12):3718–22.CrossRef
2.
go back to reference Basmajian JV, Lovejoy JF Jr. Functions of the popliteus muscle in man. A multifactorial electromyographic study. J Bone Joint Surg Am. 1971;53(3):557–62.CrossRef Basmajian JV, Lovejoy JF Jr. Functions of the popliteus muscle in man. A multifactorial electromyographic study. J Bone Joint Surg Am. 1971;53(3):557–62.CrossRef
3.
go back to reference de Simone V, Demey G, Magunussen RA, Lustig S, Servien E, Neyret P. Iatrogenic popliteus tendon injury during total knee arthroplasty results in decreased knee function two to three years postoperatively. Int Orthop. 2012;36:2061–5.CrossRef de Simone V, Demey G, Magunussen RA, Lustig S, Servien E, Neyret P. Iatrogenic popliteus tendon injury during total knee arthroplasty results in decreased knee function two to three years postoperatively. Int Orthop. 2012;36:2061–5.CrossRef
4.
go back to reference Ghosh KM, Hunt N, Blain A, Athwal KK, Longstaff L, Amis AA, Rushton S, Deehan DJ. Isolated popliteus tendon injury does not lead to abnormal laxity in posterior-stabilised total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2015;23(6):1763–9.CrossRef Ghosh KM, Hunt N, Blain A, Athwal KK, Longstaff L, Amis AA, Rushton S, Deehan DJ. Isolated popliteus tendon injury does not lead to abnormal laxity in posterior-stabilised total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2015;23(6):1763–9.CrossRef
5.
go back to reference LaPrade RF, Wozniczka JK, Stellmaker MP, Wijdicks CA. Analysis of the static function of the popliteus tendon and evaluation of an anatomic reconstruction: the "fifth ligament" of the knee. Am J Sports Med. 2010;38(3):543–9.CrossRef LaPrade RF, Wozniczka JK, Stellmaker MP, Wijdicks CA. Analysis of the static function of the popliteus tendon and evaluation of an anatomic reconstruction: the "fifth ligament" of the knee. Am J Sports Med. 2010;38(3):543–9.CrossRef
6.
go back to reference Ferrari DA, Wilson DR, Hayes WC. The effect of release of the popliteus and quadriceps force on rotation of the knee. Clin Orthop Relat Res. 2003;412:225–33.CrossRef Ferrari DA, Wilson DR, Hayes WC. The effect of release of the popliteus and quadriceps force on rotation of the knee. Clin Orthop Relat Res. 2003;412:225–33.CrossRef
7.
go back to reference Pasque C, Noyes FR, Gibbons M, Levy M, Grood E. The role of the popliteofibular ligament and the tendon of popliteus in providing stability in the human knee. J Bone Joint Surg Br. 2003;85-B:292–8.CrossRef Pasque C, Noyes FR, Gibbons M, Levy M, Grood E. The role of the popliteofibular ligament and the tendon of popliteus in providing stability in the human knee. J Bone Joint Surg Br. 2003;85-B:292–8.CrossRef
8.
go back to reference Takeda S, Tajima G, Fujino K, Yan J, Kamei Y, Maruyama M, Kikuchi S. Doita M. Morphology of the femoral insertion of the lateral collateral ligament and popliteus tendon. 2015;23:3049–54. Takeda S, Tajima G, Fujino K, Yan J, Kamei Y, Maruyama M, Kikuchi S. Doita M. Morphology of the femoral insertion of the lateral collateral ligament and popliteus tendon. 2015;23:3049–54.
10.
go back to reference Berman AT, Zarro VJ, Bosacco SJ, Israelite C. Quantitative gait analysis after unilateral or bilateral total knee replacement. J Bone Joint Surg Am. 1987;69:1340–5.CrossRef Berman AT, Zarro VJ, Bosacco SJ, Israelite C. Quantitative gait analysis after unilateral or bilateral total knee replacement. J Bone Joint Surg Am. 1987;69:1340–5.CrossRef
12.
go back to reference O’Connor MI. Implant survival, knee function, and pain relief after TKA: are there differences between men and women? Clin Orthop Relat Res. 2011;469:1846–51.CrossRef O’Connor MI. Implant survival, knee function, and pain relief after TKA: are there differences between men and women? Clin Orthop Relat Res. 2011;469:1846–51.CrossRef
13.
go back to reference Shan L, Shan B, Suzuki A, Nouh F, Saxena A. Intermediate and long-term quality of life after total knee replacement: a systematic review and meta-analysis. J Bone Joint Surg Am. 2015;97:156–68.CrossRef Shan L, Shan B, Suzuki A, Nouh F, Saxena A. Intermediate and long-term quality of life after total knee replacement: a systematic review and meta-analysis. J Bone Joint Surg Am. 2015;97:156–68.CrossRef
14.
go back to reference Takubo A, Ryu K, Iriuchishima T, Tokuhashi Y. Comparison of muscle recovery following bi-cruciate substituting versus posterior stabilized Total knee Arthroplasty in the Asian population. J Knee Surg. 2017;30(7):725–9.CrossRef Takubo A, Ryu K, Iriuchishima T, Tokuhashi Y. Comparison of muscle recovery following bi-cruciate substituting versus posterior stabilized Total knee Arthroplasty in the Asian population. J Knee Surg. 2017;30(7):725–9.CrossRef
15.
go back to reference Takahashi A, Sugita T, Aizawa T, Chiba D, Kamimura M, Aki T, Itoi E. Potential risk of excising the femoral insertion of the popliteus tendon during primary total knee arthroplasty: a biometric study. J Orthop Sci. 2015;20(6):1030–5.PubMed Takahashi A, Sugita T, Aizawa T, Chiba D, Kamimura M, Aki T, Itoi E. Potential risk of excising the femoral insertion of the popliteus tendon during primary total knee arthroplasty: a biometric study. J Orthop Sci. 2015;20(6):1030–5.PubMed
16.
go back to reference Tantavisut S, Tanavalee A, Ngarmukos S, Limtrakul A, Wilairatana V, Wangroongub Y. Gap changes after popliteus-tendon resection in PS-TKA:a cadaveric study in Thai female knees. Knee. 2012;19(5):597–600.CrossRef Tantavisut S, Tanavalee A, Ngarmukos S, Limtrakul A, Wilairatana V, Wangroongub Y. Gap changes after popliteus-tendon resection in PS-TKA:a cadaveric study in Thai female knees. Knee. 2012;19(5):597–600.CrossRef
17.
go back to reference Ettinger M, Claassen L, Paes P, Calliess T. 2D versus 3D templating in total knee arthroplasty. Knee. 2016;23(1):149–51.CrossRef Ettinger M, Claassen L, Paes P, Calliess T. 2D versus 3D templating in total knee arthroplasty. Knee. 2016;23(1):149–51.CrossRef
18.
go back to reference Miura M, Hagiwara S, Nakamura J, Wako Y, Kawarai Y, Ohtori S. Interobserver and Intraobserver reliability of computed tomography-based three-dimensional preoperative planning for primary Total knee Arthroplasty. J Arthroplast. 2018;33:1572–8.CrossRef Miura M, Hagiwara S, Nakamura J, Wako Y, Kawarai Y, Ohtori S. Interobserver and Intraobserver reliability of computed tomography-based three-dimensional preoperative planning for primary Total knee Arthroplasty. J Arthroplast. 2018;33:1572–8.CrossRef
19.
go back to reference Kesman TJ, Kaufman KR, Trousdale RT. Popliteus tendon resection during total knee arthroplasty: an observational report. Clin Orthop Relat Res. 2011;469(1):76–81.CrossRef Kesman TJ, Kaufman KR, Trousdale RT. Popliteus tendon resection during total knee arthroplasty: an observational report. Clin Orthop Relat Res. 2011;469(1):76–81.CrossRef
Metadata
Title
The evaluation of the distance between the popliteus tendon and the lateral collateral ligament footprint and the implant in Total knee Arthroplasty using a 3-dimensional template
Authors
Akihito Takubo
Keinosuke Ryu
Takanori Iriuchishima
Masahiro Nagaoka
Yasuaki Tokuhashi
Shin Aizawa
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2020
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-020-03347-6

Other articles of this Issue 1/2020

BMC Musculoskeletal Disorders 1/2020 Go to the issue