Skip to main content
Top
Published in: European Radiology 3/2020

01-03-2020 | Computed Tomography | Cardiac

Prediction of pulmonary pressure after Glenn shunts by computed tomography–based machine learning models

Authors: Lei Huang, Jiahua Li, Meiping Huang, Jian Zhuang, Haiyun Yuan, Qianjun Jia, Dewen Zeng, Lifeng Que, Yue Xi, Jijin Lin, Yuhao Dong

Published in: European Radiology | Issue 3/2020

Login to get access

Abstract

Objectives

This study aimed to develop non-invasive machine learning classifiers for predicting post–Glenn shunt patients with low and high risks of a mean pulmonary arterial pressure (mPAP) > 15 mmHg based on preoperative cardiac computed tomography (CT).

Methods

This retrospective study included 96 patients with functional single ventricle who underwent a bidirectional Glenn procedure between November 1, 2009, and July, 31, 2017. All patients underwent post-procedure CT, followed by cardiac catheterization. Overall, 23 morphologic parameters were manually extracted from cardiac CT images for each patient. The Mann-Whitney U or chi-square test was applied to select the most significant predictors. Six machine learning algorithms including logistic regression, Naive Bayes, random forest (RF), linear discriminant analysis, support vector machine, and K-nearest neighbor were used for modeling. These algorithms were independently trained on 100 train-validation random splits with a 3:1 ratio. Their average performance was evaluated by area under the curve (AUC), accuracy, sensitivity, and specificity.

Results

Seven CT morphologic parameters were selected for modeling. RF obtained the best performance, with mean AUC of 0.840 (confidence interval [CI] 0.832–0.850) and 0.787 (95% CI 0.780–0.794); sensitivity of 0.815 (95% CI 0.797–0.833) and 0.778 (95% CI 0.767–0.788), specificity of 0.766 (95% CI 0.748–0.785) and 0.746 (95% CI 0.735–0.757); and accuracy of 0.782 (95% CI 0.771–0.793) and 0.756 (95% CI 0.748–0.764) in the training and validation cohorts, respectively.

Conclusions

The CT-based RF model demonstrates a good performance in the prediction of mPAP, which may reduce the need for right heart catheterization in post–Glenn shunt patients with suspected mPAP > 15 mmHg.

Key Points

• Twenty-three candidate descriptors were manually extracted from cardiac computed tomography images, and seven of them were selected for subsequent modeling.
• The random forest model presents the best predictive performance for pulmonary pressure among all methods.
• The computed tomography–based machine learning model could predict post–Glenn shunt pulmonary pressure non-invasively.
Literature
1.
go back to reference Tanoue Y, Kado H, Boku N et al (2007) Three hundred and thirty-three experiences with the bidirectional Glenn procedure in a single institute. Interact Cardiovasc Thorac Surg 6:97–101CrossRef Tanoue Y, Kado H, Boku N et al (2007) Three hundred and thirty-three experiences with the bidirectional Glenn procedure in a single institute. Interact Cardiovasc Thorac Surg 6:97–101CrossRef
2.
go back to reference Hosein RB, Clarke AJ, McGuirk SP et al (2007) Factors influencing early and late outcome following the Fontan procedure in the current era. The ‘Two Commandments?’. Eur J Cardiothorac Surg 31:344–352CrossRef Hosein RB, Clarke AJ, McGuirk SP et al (2007) Factors influencing early and late outcome following the Fontan procedure in the current era. The ‘Two Commandments?’. Eur J Cardiothorac Surg 31:344–352CrossRef
3.
go back to reference Stern HJ (2010) Fontan “Ten Commandments” revisited and revised. Pediatr Cardiol 31:1131–1134CrossRef Stern HJ (2010) Fontan “Ten Commandments” revisited and revised. Pediatr Cardiol 31:1131–1134CrossRef
4.
go back to reference Mandel J, Poch D (2013) In the clinic. Pulmonary hypertension. Ann Intern Med 158:C1–C5CrossRef Mandel J, Poch D (2013) In the clinic. Pulmonary hypertension. Ann Intern Med 158:C1–C5CrossRef
5.
go back to reference Hoeper MM, Lee SH, Voswinckel R et al (2006) Complications of right heart catheterization procedures in patients with pulmonary hypertension in experienced centers. J Am Coll Cardiol 48:2546–2552CrossRef Hoeper MM, Lee SH, Voswinckel R et al (2006) Complications of right heart catheterization procedures in patients with pulmonary hypertension in experienced centers. J Am Coll Cardiol 48:2546–2552CrossRef
6.
go back to reference Stern KW, McElhinney DB, Gauvreau K, Geva T, Brown DW (2011) Echocardiographic evaluation before bidirectional Glenn operation in functional single-ventricle heart disease: comparison to catheter angiography. Circ Cardiovasc Imaging 4:498–505CrossRef Stern KW, McElhinney DB, Gauvreau K, Geva T, Brown DW (2011) Echocardiographic evaluation before bidirectional Glenn operation in functional single-ventricle heart disease: comparison to catheter angiography. Circ Cardiovasc Imaging 4:498–505CrossRef
7.
go back to reference Shen Y, Wan C, Tian P et al (2014) CT-base pulmonary artery measurement in the detection of pulmonary hypertension: a meta-analysis and systematic review. Medicine (Baltimore) 93:e256CrossRef Shen Y, Wan C, Tian P et al (2014) CT-base pulmonary artery measurement in the detection of pulmonary hypertension: a meta-analysis and systematic review. Medicine (Baltimore) 93:e256CrossRef
8.
go back to reference Janda S, Shahidi N, Gin K, Swiston J (2011) Diagnostic accuracy of echocardiography for pulmonary hypertension: a systematic review and meta-analysis. Heart 97:612–622CrossRef Janda S, Shahidi N, Gin K, Swiston J (2011) Diagnostic accuracy of echocardiography for pulmonary hypertension: a systematic review and meta-analysis. Heart 97:612–622CrossRef
9.
go back to reference Wang N, Hu X, Liu C et al (2014) A systematic review of the diagnostic accuracy of cardiovascular magnetic resonance for pulmonary hypertension. Can J Cardiol 30:455–463CrossRef Wang N, Hu X, Liu C et al (2014) A systematic review of the diagnostic accuracy of cardiovascular magnetic resonance for pulmonary hypertension. Can J Cardiol 30:455–463CrossRef
10.
go back to reference Chen X, Liu K, Wang Z et al (2015) Computed tomography measurement of pulmonary artery for diagnosis of COPD and its comorbidity pulmonary hypertension. Int J Chron Obstruct Pulmon Dis 10:2525–2533CrossRef Chen X, Liu K, Wang Z et al (2015) Computed tomography measurement of pulmonary artery for diagnosis of COPD and its comorbidity pulmonary hypertension. Int J Chron Obstruct Pulmon Dis 10:2525–2533CrossRef
11.
go back to reference Rajaram S, Swift AJ, Condliffe R et al (2015) CT features of pulmonary arterial hypertension and its major subtypes: a systematic CT evaluation of 292 patients from the ASPIRE Registry. Thorax 70:382–387CrossRef Rajaram S, Swift AJ, Condliffe R et al (2015) CT features of pulmonary arterial hypertension and its major subtypes: a systematic CT evaluation of 292 patients from the ASPIRE Registry. Thorax 70:382–387CrossRef
12.
go back to reference Grosse C, Grosse A (2010) CT findings in diseases associated with pulmonary hypertension: a current review. Radiographics 30:1753–1777CrossRef Grosse C, Grosse A (2010) CT findings in diseases associated with pulmonary hypertension: a current review. Radiographics 30:1753–1777CrossRef
13.
go back to reference Abel E, Jankowski A, Pison C, Luc Bosson J, Bouvaist H, Ferretti GR (2012) Pulmonary artery and right ventricle assessment in pulmonary hypertension: correlation between functional parameters of ECG-gated CT and right-side heart catheterization. Acta Radiol 53:720–727CrossRef Abel E, Jankowski A, Pison C, Luc Bosson J, Bouvaist H, Ferretti GR (2012) Pulmonary artery and right ventricle assessment in pulmonary hypertension: correlation between functional parameters of ECG-gated CT and right-side heart catheterization. Acta Radiol 53:720–727CrossRef
14.
go back to reference Siegel Y, Mirpuri T (2014) Pulmonary hypertension detection using dynamic and static measurable parameters on CT angiography. J Comput Assist Tomogr 38:586–590CrossRef Siegel Y, Mirpuri T (2014) Pulmonary hypertension detection using dynamic and static measurable parameters on CT angiography. J Comput Assist Tomogr 38:586–590CrossRef
15.
go back to reference Mahammedi A, Oshmyansky A, Hassoun PM, Thiemann DR, Siegelman SS (2013) Pulmonary artery measurements in pulmonary hypertension: the role of computed tomography. J Thorac Imaging 28:96–103CrossRef Mahammedi A, Oshmyansky A, Hassoun PM, Thiemann DR, Siegelman SS (2013) Pulmonary artery measurements in pulmonary hypertension: the role of computed tomography. J Thorac Imaging 28:96–103CrossRef
16.
go back to reference Goldstein BA, Navar AM, Carter RE (2017) Moving beyond regression techniques in cardiovascular risk prediction: applying machine learning to address analytic challenges. Eur Heart J 38:1805–1814PubMed Goldstein BA, Navar AM, Carter RE (2017) Moving beyond regression techniques in cardiovascular risk prediction: applying machine learning to address analytic challenges. Eur Heart J 38:1805–1814PubMed
17.
go back to reference Krittanawong C, Zhang H, Wang Z, Aydar M, Kitai T (2017) Artificial intelligence in precision cardiovascular medicine. J Am Coll Cardiol 69:2657–2664CrossRef Krittanawong C, Zhang H, Wang Z, Aydar M, Kitai T (2017) Artificial intelligence in precision cardiovascular medicine. J Am Coll Cardiol 69:2657–2664CrossRef
19.
go back to reference Darcy AM, Louie AK, Roberts LW (2016) Machine learning and the profession of medicine. JAMA 315:551–552CrossRef Darcy AM, Louie AK, Roberts LW (2016) Machine learning and the profession of medicine. JAMA 315:551–552CrossRef
20.
go back to reference Hae H, Kang SJ, Kim WJ et al (2018) Machine learning assessment of myocardial ischemia using angiography: development and retrospective validation. PLoS Med 15:e1002693CrossRef Hae H, Kang SJ, Kim WJ et al (2018) Machine learning assessment of myocardial ischemia using angiography: development and retrospective validation. PLoS Med 15:e1002693CrossRef
21.
go back to reference Liu H, Juan YH, Wang Q et al (2014) Evaluation of malposition of the branch pulmonary arteries using cardiovascular computed tomography angiography. Eur Radiol 24:3300–3307CrossRef Liu H, Juan YH, Wang Q et al (2014) Evaluation of malposition of the branch pulmonary arteries using cardiovascular computed tomography angiography. Eur Radiol 24:3300–3307CrossRef
22.
go back to reference Yagi M, Taniguchi H, Kondoh Y et al (2017) CT-determined pulmonary artery to aorta ratio as a predictor of elevated pulmonary artery pressure and survival in idiopathic pulmonary fibrosis. Respirology 22:1393–1399CrossRef Yagi M, Taniguchi H, Kondoh Y et al (2017) CT-determined pulmonary artery to aorta ratio as a predictor of elevated pulmonary artery pressure and survival in idiopathic pulmonary fibrosis. Respirology 22:1393–1399CrossRef
23.
go back to reference Nakata S, Imai Y, Takanashi Y et al (1984) A new method for the quantitative standardization of cross-sectional areas of the pulmonary arteries in congenital heart diseases with decreased pulmonary blood flow. J Thorac Cardiovasc Surg 88:610–619CrossRef Nakata S, Imai Y, Takanashi Y et al (1984) A new method for the quantitative standardization of cross-sectional areas of the pulmonary arteries in congenital heart diseases with decreased pulmonary blood flow. J Thorac Cardiovasc Surg 88:610–619CrossRef
24.
go back to reference Fiore AC, Tobin C, Jureidini S, Rahimi M, Kim ES, Schowengerdt K (2011) A comparison of the modified Blalock-Taussig shunt with the right ventricle-to-pulmonary artery conduit. Ann Thorac Surg 91:1479–1484 1484–1485CrossRef Fiore AC, Tobin C, Jureidini S, Rahimi M, Kim ES, Schowengerdt K (2011) A comparison of the modified Blalock-Taussig shunt with the right ventricle-to-pulmonary artery conduit. Ann Thorac Surg 91:1479–1484 1484–1485CrossRef
25.
go back to reference Jia Q, Cen J, Zhuang J et al (2017) Significant survival advantage of high pulmonary vein index and the presence of native pulmonary artery in pulmonary atresia with ventricular septal defect and major aortopulmonary collateral arteries: results from preoperative computed tomography angiography. Eur J Cardiothorac Surg 52:225–232CrossRef Jia Q, Cen J, Zhuang J et al (2017) Significant survival advantage of high pulmonary vein index and the presence of native pulmonary artery in pulmonary atresia with ventricular septal defect and major aortopulmonary collateral arteries: results from preoperative computed tomography angiography. Eur J Cardiothorac Surg 52:225–232CrossRef
26.
go back to reference Maeda E, Akahane M, Kato N et al (2006) Assessment of major aortopulmonary collateral arteries with multidetector-row computed tomography. Radiat Med 24:378–383CrossRef Maeda E, Akahane M, Kato N et al (2006) Assessment of major aortopulmonary collateral arteries with multidetector-row computed tomography. Radiat Med 24:378–383CrossRef
27.
28.
go back to reference Zhang Y, Zhang B, Liang F et al (2019) Radiomics features on non-contrast-enhanced CT scan can precisely classify AVM-related hematomas from other spontaneous intraparenchymal hematoma types. Eur Radiol 29:2157–2165CrossRef Zhang Y, Zhang B, Liang F et al (2019) Radiomics features on non-contrast-enhanced CT scan can precisely classify AVM-related hematomas from other spontaneous intraparenchymal hematoma types. Eur Radiol 29:2157–2165CrossRef
30.
go back to reference Lungu A, Swift AJ, Capener D, Kiely D, Hose R, Wild JM (2016) Diagnosis of pulmonary hypertension from magnetic resonance imaging-based computational models and decision tree analysis. Pulm Circ 6:181–190CrossRef Lungu A, Swift AJ, Capener D, Kiely D, Hose R, Wild JM (2016) Diagnosis of pulmonary hypertension from magnetic resonance imaging-based computational models and decision tree analysis. Pulm Circ 6:181–190CrossRef
31.
go back to reference Dawes T, de Marvao A, Shi W et al (2017) Machine learning of three-dimensional right ventricular motion enables outcome prediction in pulmonary hypertension: a cardiac MR imaging study. Radiology 283:381–390CrossRef Dawes T, de Marvao A, Shi W et al (2017) Machine learning of three-dimensional right ventricular motion enables outcome prediction in pulmonary hypertension: a cardiac MR imaging study. Radiology 283:381–390CrossRef
32.
go back to reference Dennis A, Michaels AD, Arand P, Ventura D (2010) Noninvasive diagnosis of pulmonary hypertension using heart sound analysis. Comput Biol Med 40:758–764CrossRef Dennis A, Michaels AD, Arand P, Ventura D (2010) Noninvasive diagnosis of pulmonary hypertension using heart sound analysis. Comput Biol Med 40:758–764CrossRef
34.
go back to reference Diller GP, Kempny A, Babu-Narayan SV, et al (2019) Machine learning algorithms estimating prognosis and guiding therapy in adult congenital heart disease: data from a single tertiary centre including 10 019 patients. Eur Heart J 40:1069–1077CrossRef Diller GP, Kempny A, Babu-Narayan SV, et al (2019) Machine learning algorithms estimating prognosis and guiding therapy in adult congenital heart disease: data from a single tertiary centre including 10 019 patients. Eur Heart J 40:1069–1077CrossRef
35.
go back to reference Zhang B, He X, Ouyang F et al (2017) Radiomic machine-learning classifiers for prognostic biomarkers of advanced nasopharyngeal carcinoma. Cancer Lett 403:21–27CrossRef Zhang B, He X, Ouyang F et al (2017) Radiomic machine-learning classifiers for prognostic biomarkers of advanced nasopharyngeal carcinoma. Cancer Lett 403:21–27CrossRef
36.
go back to reference Nagasawa S, Al-Naamani E, Saeki A (2018) Computer-aided screening of conjugated polymers for organic solar cell: classification by random forest. J Phys Chem Lett 9:2639–2646CrossRef Nagasawa S, Al-Naamani E, Saeki A (2018) Computer-aided screening of conjugated polymers for organic solar cell: classification by random forest. J Phys Chem Lett 9:2639–2646CrossRef
37.
go back to reference Yao Y, Li X, Liao B et al (2017) Predicting influenza antigenicity from Hemagglutintin sequence data based on a joint random forest method. Sci Rep 7:1545CrossRef Yao Y, Li X, Liao B et al (2017) Predicting influenza antigenicity from Hemagglutintin sequence data based on a joint random forest method. Sci Rep 7:1545CrossRef
38.
go back to reference Eshaghi A, Wottschel V, Cortese R et al (2016) Gray matter MRI differentiates neuromyelitis optica from multiple sclerosis using random forest. Neurology 87:2463–2470CrossRef Eshaghi A, Wottschel V, Cortese R et al (2016) Gray matter MRI differentiates neuromyelitis optica from multiple sclerosis using random forest. Neurology 87:2463–2470CrossRef
39.
go back to reference Gray KR, Aljabar P, Heckemann RA, Hammers A, Rueckert D (2013) Random forest-based similarity measures for multi-modal classification of Alzheimer’s disease. Neuroimage 65:167–175CrossRef Gray KR, Aljabar P, Heckemann RA, Hammers A, Rueckert D (2013) Random forest-based similarity measures for multi-modal classification of Alzheimer’s disease. Neuroimage 65:167–175CrossRef
40.
go back to reference Esmaily-Moghadam M, Hsia TY, Marsden AL (2015) The assisted bidirectional Glenn: a novel surgical approach for first-stage single-ventricle heart palliation. J Thorac Cardiovasc Surg 149:699–705CrossRef Esmaily-Moghadam M, Hsia TY, Marsden AL (2015) The assisted bidirectional Glenn: a novel surgical approach for first-stage single-ventricle heart palliation. J Thorac Cardiovasc Surg 149:699–705CrossRef
Metadata
Title
Prediction of pulmonary pressure after Glenn shunts by computed tomography–based machine learning models
Authors
Lei Huang
Jiahua Li
Meiping Huang
Jian Zhuang
Haiyun Yuan
Qianjun Jia
Dewen Zeng
Lifeng Que
Yue Xi
Jijin Lin
Yuhao Dong
Publication date
01-03-2020
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 3/2020
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-019-06502-3

Other articles of this Issue 3/2020

European Radiology 3/2020 Go to the issue