Minimum size and positioning of imaging field for CBCT-scans of impacted lower third molars: a retrospective study

Authors: Anne-Mari Ilo, Marja Ekholm, Elmira Pakbaznejad Esmaeili, Janna Waltimo-Sirén

Published in: BMC Oral Health | Issue 1/2021

Login to get access

Abstract

Background

Cone-beam Computed Tomography (CBCT) is widely used for preoperative 3D imaging of lower third molars. Hence, for this imaging indication, the present study aimed to define the minimum field-of-view (FOV) size and its optimum placement, to decrease radiation exposure, and highlight the need of computer-assisted FOV centering technique for dental CBCT devices. To facilitate proper placement of image field, lower second molar was chosen as reference.

Methods

The retrospective study included 50 CBCT-scans of 46 patients with mean age of 34 years. Based on the lower second molar, a three-dimensional coordinate was formed and the location of mandibular canal (MC) and the dimensions and locations of the lower third molars, and possible associated pathological findings were assessed. Accordingly, the FOV size and position for third-molar imaging were optimized, while ensuring encompassment of all relevant structures.

Results

The minimum cylindrical volume, covering lower third molars and MC, was 32.1 (diameter) × 31.6 (height) mm, placed in relation to the second molar crown, top 2.2 mm above cusp tips, anterior edge 6.7 mm in the front of the most distal point of the crown, and lingual edge 7.9 mm on the medial side of the lingual wall.

Conclusions

The optimized FOV for lower third molars was smaller than common standard small FOVs. We recommend using FOV volume 3.5∅ × 3.5 cm for third molars without associated pathology. Accurate FOV protocols are essential for development of new CBCT-devices with computer-assisted and indication-specific FOV placement.
Literature
11.
go back to reference Beganović A, Ciraj-Bjelac O, Dyakov I, Gershan V, Kralik I, Milatović A, Šalát D, Stepanyan K, Vladimirov A, Vassileva J. IAEA survey of dental cone beam computed tomography practice and related patient exposure in nine Central and Eastern European countries. Dentomaxillofac Radiol. 2019;48:20190157. https://doi.org/10.1259/dmfr.20190157.CrossRefPubMed Beganović A, Ciraj-Bjelac O, Dyakov I, Gershan V, Kralik I, Milatović A, Šalát D, Stepanyan K, Vladimirov A, Vassileva J. IAEA survey of dental cone beam computed tomography practice and related patient exposure in nine Central and Eastern European countries. Dentomaxillofac Radiol. 2019;48:20190157. https://​doi.​org/​10.​1259/​dmfr.​20190157.CrossRefPubMed
12.
go back to reference Pauwels R, Beinsberger J, Collaert B, Theodorakou C, Rogers J, Walker A, Cockmartin L, Bosmans H, Jacobs R, Bogaerts R, Horner K, The SEDENTEXCT Project Consortium. Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol. 2019;81:267–271. https://doi.org/10.1016/j.ejrad.2010.11.028. Pauwels R, Beinsberger J, Collaert B, Theodorakou C, Rogers J, Walker A, Cockmartin L, Bosmans H, Jacobs R, Bogaerts R, Horner K, The SEDENTEXCT Project Consortium. Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol. 2019;81:267–271. https://​doi.​org/​10.​1016/​j.​ejrad.​2010.​11.​028.
22.
go back to reference von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP; STROBE Initiative. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. Int J Surg. 2014;12:1495–9. https://doi.org/10.1016/j.ijsu.2014.07.013. von Elm E, Altman DG, Egger M, Pocock SJ, Gøtzsche PC, Vandenbroucke JP; STROBE Initiative. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. Int J Surg. 2014;12:1495–9. https://​doi.​org/​10.​1016/​j.​ijsu.​2014.​07.​013.
Metadata
Title
Minimum size and positioning of imaging field for CBCT-scans of impacted lower third molars: a retrospective study
Authors
Anne-Mari Ilo
Marja Ekholm
Elmira Pakbaznejad Esmaeili
Janna Waltimo-Sirén
Publication date
01-12-2021
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2021
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-021-02029-6

Other articles of this Issue 1/2021

BMC Oral Health 1/2021 Go to the issue