Abstract

Background

From a biomechanical point of view, pedicle screws (PS) are better than other kinds of screws for implantation in the seventh cervical vertebra (C7). However, the application of PS is limited because of the high risk of severe complications. It is essential to define the optimal entry point and trajectory. The aim of this study was to comprehensively analyze the starting point and trajectory for C7 PS insertion using three dimensional (3D) models.

Methods

Overall, 60 subjects aged 18 to 67 years old were included. All CT images were used to construct 3D computer models of the C7 vertebrae. A new coordinate system was established for the next evaluation. The pedicle axis was calculated with respect to the entire pedicle; then, the ideal entry point, screw diameter and length, sagittal angle and lateral angle were assessed.

Results

All the ideal entry points were located at the medial superior to lateral notch (LN), and the mean distance between the entry point and LN was 5.86 ± 1.67 mm in the horizontal direction and 3.47 ± 1.57 mm in the vertical direction. The mean distance between the entry point and the middle point of the inferior edge of the C6 articular process (MP) was 0.74 ± 1.83 mm in the horizontal direction. The mean sagittal angle of the pedicle axis was 90.42°, and the mean pedicle transverse angle was 30.70°. The average diameter and length of the PS were 6.51 ± 0.76 mm and 31.58 ± 4.40 mm, respectively.

Conclusions

This study provided a novel method to calculate the ideal starting point and trajectory for C7 PS insertion. These measurements may be helpful for preoperative planning. It is recommended that 3D CT imaging is used preoperatively to carefully evaluate the anatomy of each individual.
Literature
6.
go back to reference Liu YJ, Tian W, Liu B, et al. Comparison of the clinical accuracy of cervical (C2–C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation. Chin Med J (Engl). 2010;123(21):2995–8. Liu YJ, Tian W, Liu B, et al. Comparison of the clinical accuracy of cervical (C2–C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation. Chin Med J (Engl). 2010;123(21):2995–8.
Metadata
Title
Comprehensive analysis of pedicle screw implantation in the C7 vertebra using computed tomography-based three-dimensional models
Authors
Huan Liu
Zhi-Yong Zhou
Jia-Xu Wei
Ming Zhang
Meng Bai
Ai-Bing Huang
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Surgery / Issue 1/2022
Electronic ISSN: 1471-2482
DOI
https://doi.org/10.1186/s12893-022-01548-5

Other articles of this Issue 1/2022

BMC Surgery 1/2022 Go to the issue