Background

Medial open wedge high tibial osteotomy is a well-established procedure for the treatment of unicompartmental osteoarthritis and symptomatic varus malalignment. We hypothesized that different fixation devices generate different fixation stability profiles for the various wedge sizes in a finite element (FE) analysis.

Methods

Four types of fixation were compared: 1) first and 2) second generation Puddu plates, and 3) TomoFix plate with and 4) without bone graft. Cortical and cancellous bone was modelled and five different opening wedge sizes were studied for each model. Outcome measures included: 1) stresses in bone, 2) relative displacement of the proximal and distal tibial fragments, 3) stresses in the plates, 4) stresses on the upper and lower screw surfaces in the screw channels.

Results

The highest load for all fixation types occurred in the plate axis. For the vast majority of the wedge sizes and fixation types the shear stress (von Mises stress) was dominating in the bone independent of fixation type. The relative displacements of the tibial fragments were low (in μm range). With an increasing wedge size this displacement tended to increase for both Puddu plates and the TomoFix plate with bone graft. For the TomoFix plate without bone graft a rather opposite trend was observed.
For all fixation types the occurring stresses at the screw-bone contact areas pulled at the screws and exceeded the allowable threshold of 1.2 MPa for at least one screw surface. Of the six screw surfaces that were studied, the TomoFix plate with bone graft showed a stress excess of one out of twelve and without bone graft, five out of twelve. With the Puddu plates, an excess stress occurred in the majority of screw surfaces.

Conclusions

The different fixation devices generate different fixation stability profiles for different opening wedge sizes. Based on the computational simulations, none of the studied osteosynthesis fixation types warranted an intransigent full weight bearing per se. The highest fixation stability was observed for the TomoFix plates and the lowest for the first generation Puddu plate. These findings were revealed in theoretical models and need to be validated in controlled clinical settings.
Appendix
Available only for authorised users
Literature
1.
go back to reference Coventry MB: Upper tibial osteotomy for gonarthrosis. The evolution of the operation in the last 18 years and long term results. Orthop Clin North Am. 1979, 10: 191-210.PubMed Coventry MB: Upper tibial osteotomy for gonarthrosis. The evolution of the operation in the last 18 years and long term results. Orthop Clin North Am. 1979, 10: 191-210.PubMed
2.
go back to reference Hernigou P, Medevielle D, Debeyre J, Goutallier D: Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am. 1987, 69: 332-354.PubMed Hernigou P, Medevielle D, Debeyre J, Goutallier D: Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am. 1987, 69: 332-354.PubMed
3.
go back to reference Staubli AE, De Simoni C, Babst R, Lobenhoffer P: TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia–early results in 92 cases. Injury. 2003, 34 (Suppl 2): B55-62.CrossRefPubMed Staubli AE, De Simoni C, Babst R, Lobenhoffer P: TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia–early results in 92 cases. Injury. 2003, 34 (Suppl 2): B55-62.CrossRefPubMed
4.
go back to reference Niemeyer P, Schmal H, Hauschild O, von Heyden J, Sudkamp NP, Kostler W: Open-wedge osteotomy using an internal plate fixator in patients with medial-compartment gonarthritis and varus malalignment: 3-year results with regard to preoperative arthroscopic and radiographic findings. Arthroscopy. 2010, 26: 1607-1616. 10.1016/j.arthro.2010.05.006.CrossRefPubMed Niemeyer P, Schmal H, Hauschild O, von Heyden J, Sudkamp NP, Kostler W: Open-wedge osteotomy using an internal plate fixator in patients with medial-compartment gonarthritis and varus malalignment: 3-year results with regard to preoperative arthroscopic and radiographic findings. Arthroscopy. 2010, 26: 1607-1616. 10.1016/j.arthro.2010.05.006.CrossRefPubMed
5.
go back to reference Smith JO, Wilson AJ, Thomas NP: Osteotomy around the knee: evolution, principles and results. Knee Surg Sports Traumatol Arthrosc. 2013, 21: 3-22. 10.1007/s00167-012-2206-0.CrossRefPubMed Smith JO, Wilson AJ, Thomas NP: Osteotomy around the knee: evolution, principles and results. Knee Surg Sports Traumatol Arthrosc. 2013, 21: 3-22. 10.1007/s00167-012-2206-0.CrossRefPubMed
6.
go back to reference Seil R, van Heerwaarden R, Lobenhoffer P, Kohn D: The rapid evolution of knee osteotomies. Knee Surg Sports Traumatol Arthrosc. 2013, 21: 1-2. 10.1007/s00167-012-2175-3.CrossRefPubMed Seil R, van Heerwaarden R, Lobenhoffer P, Kohn D: The rapid evolution of knee osteotomies. Knee Surg Sports Traumatol Arthrosc. 2013, 21: 1-2. 10.1007/s00167-012-2175-3.CrossRefPubMed
7.
go back to reference Brinkman JM, Lobenhoffer P, Agneskirchner JD, Staubli AE, Wymenga AB, van Heerwaarden RJ: Osteotomies around the knee: patient selection, stability of fixation and bone healing in high tibial osteotomies. J Bone Joint Surg. 2008, 90: 1548-1557.CrossRef Brinkman JM, Lobenhoffer P, Agneskirchner JD, Staubli AE, Wymenga AB, van Heerwaarden RJ: Osteotomies around the knee: patient selection, stability of fixation and bone healing in high tibial osteotomies. J Bone Joint Surg. 2008, 90: 1548-1557.CrossRef
8.
go back to reference Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P: Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc. 2006, 14: 291-300. 10.1007/s00167-005-0690-1.CrossRefPubMed Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P: Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc. 2006, 14: 291-300. 10.1007/s00167-005-0690-1.CrossRefPubMed
9.
go back to reference Dorsey WO, Miller BS, Tadje JP, Bryant CR: The stability of three commercially available implants used in medial opening wedge high tibial osteotomy. J Knee Surg. 2006, 19: 95-98.PubMed Dorsey WO, Miller BS, Tadje JP, Bryant CR: The stability of three commercially available implants used in medial opening wedge high tibial osteotomy. J Knee Surg. 2006, 19: 95-98.PubMed
10.
go back to reference Spahn G, Muckley T, Kahl E, Hofmann GO: Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy. Clin Biomech. 2006, 21: 272-278. 10.1016/j.clinbiomech.2005.10.010.CrossRef Spahn G, Muckley T, Kahl E, Hofmann GO: Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy. Clin Biomech. 2006, 21: 272-278. 10.1016/j.clinbiomech.2005.10.010.CrossRef
11.
go back to reference Spahn G, Wittig R: Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study. J Orthop Sci. 2002, 7: 683-687. 10.1007/s007760200121.CrossRefPubMed Spahn G, Wittig R: Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study. J Orthop Sci. 2002, 7: 683-687. 10.1007/s007760200121.CrossRefPubMed
12.
go back to reference Stoffel K, Stachowiak G, Kuster M: Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate. Clin Biomech. 2004, 19: 944-950. 10.1016/j.clinbiomech.2004.06.007.CrossRef Stoffel K, Stachowiak G, Kuster M: Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate. Clin Biomech. 2004, 19: 944-950. 10.1016/j.clinbiomech.2004.06.007.CrossRef
13.
go back to reference Raja Izaham RM, Abdul Kadir MR, Abdul Rashid AH, Hossain MG, Kamarul T: Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy. Injury. 2012, 43: 898-902. 10.1016/j.injury.2011.12.006.CrossRefPubMed Raja Izaham RM, Abdul Kadir MR, Abdul Rashid AH, Hossain MG, Kamarul T: Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy. Injury. 2012, 43: 898-902. 10.1016/j.injury.2011.12.006.CrossRefPubMed
14.
go back to reference Luo CA, Hua SY, Lin SC, Chen CM, Tseng CS: Stress and stability comparison between different systems for high tibial osteotomies. BMC Musculoskelet Disord. 2013, 14: 110-10.1186/1471-2474-14-110.CrossRefPubMedPubMedCentral Luo CA, Hua SY, Lin SC, Chen CM, Tseng CS: Stress and stability comparison between different systems for high tibial osteotomies. BMC Musculoskelet Disord. 2013, 14: 110-10.1186/1471-2474-14-110.CrossRefPubMedPubMedCentral
15.
go back to reference Brosset T, Pasquier G, Migaud H, Gougeon F: Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix) and early weight-bearing: prospective evaluation of bone union, precision and maintenance of correction in 51 cases. Orthop Traumatol Surg Res. 2011, 97: 705-711. 10.1016/j.otsr.2011.06.011.CrossRefPubMed Brosset T, Pasquier G, Migaud H, Gougeon F: Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix) and early weight-bearing: prospective evaluation of bone union, precision and maintenance of correction in 51 cases. Orthop Traumatol Surg Res. 2011, 97: 705-711. 10.1016/j.otsr.2011.06.011.CrossRefPubMed
16.
go back to reference Zorzi AR, da Silva HG, Muszkat C, Marques LC, Cliquet A, de Miranda JB: Opening-wedge high tibial osteotomy with and without bone graft. Artif Organs. 2011, 35: 301-307. 10.1111/j.1525-1594.2010.01058.x.CrossRefPubMed Zorzi AR, da Silva HG, Muszkat C, Marques LC, Cliquet A, de Miranda JB: Opening-wedge high tibial osteotomy with and without bone graft. Artif Organs. 2011, 35: 301-307. 10.1111/j.1525-1594.2010.01058.x.CrossRefPubMed
17.
go back to reference Zienkiewicz OC, Taylor RL, Zhu JZ: The finite element method. 2005, Burlington, MA: Elsevier, 6 Zienkiewicz OC, Taylor RL, Zhu JZ: The finite element method. 2005, Burlington, MA: Elsevier, 6
18.
go back to reference Martinez de Albornoz P, Leyes M, Forriol F, Del Buono A, Maffulli N: Opening wedge high tibial osteotomy: plate position and biomechanics of the medial tibial plateau. Knee Surg Sports Traumatol Arthrosc. 2014, in press Martinez de Albornoz P, Leyes M, Forriol F, Del Buono A, Maffulli N: Opening wedge high tibial osteotomy: plate position and biomechanics of the medial tibial plateau. Knee Surg Sports Traumatol Arthrosc. 2014, in press
19.
go back to reference Benli S, Aksoy S, Havitcioglu H, Kucuk M: Evaluation of bone plate with low-stiffness material in terms of stress distribution. J Biomech. 2008, 41: 3229-3235. 10.1016/j.jbiomech.2008.08.003.CrossRefPubMed Benli S, Aksoy S, Havitcioglu H, Kucuk M: Evaluation of bone plate with low-stiffness material in terms of stress distribution. J Biomech. 2008, 41: 3229-3235. 10.1016/j.jbiomech.2008.08.003.CrossRefPubMed
20.
go back to reference Obraszov IF: Strength Problems in Biomechanics. 1988, Moscow: High School, 311- Obraszov IF: Strength Problems in Biomechanics. 1988, Moscow: High School, 311-
21.
go back to reference Hearn TC, Szalai JP, Surowiak JF, Schatzker J: Sample size estimates for the use of human bone in the experimental study of cancellous screw extraction mechanics. J Biomech. 1996, 29: 569-572. 10.1016/0021-9290(96)83439-7.CrossRefPubMed Hearn TC, Szalai JP, Surowiak JF, Schatzker J: Sample size estimates for the use of human bone in the experimental study of cancellous screw extraction mechanics. J Biomech. 1996, 29: 569-572. 10.1016/0021-9290(96)83439-7.CrossRefPubMed
22.
go back to reference Nelissen EM, van Langelaan EJ, Nelissen RG: Stability of medial opening wedge high tibial osteotomy: a failure analysis. Int Orthop. 2010, 34: 217-223. 10.1007/s00264-009-0723-3.CrossRefPubMed Nelissen EM, van Langelaan EJ, Nelissen RG: Stability of medial opening wedge high tibial osteotomy: a failure analysis. Int Orthop. 2010, 34: 217-223. 10.1007/s00264-009-0723-3.CrossRefPubMed
23.
go back to reference Chae DJ, Shetty GM, Wang KH, Montalban AS, Kim JI, Nha KW: Early complications of medial opening wedge high tibial osteotomy using autologous tricortical iliac bone graft and T-plate fixation. Knee. 2011, 18: 278-284. 10.1016/j.knee.2010.05.009.CrossRefPubMed Chae DJ, Shetty GM, Wang KH, Montalban AS, Kim JI, Nha KW: Early complications of medial opening wedge high tibial osteotomy using autologous tricortical iliac bone graft and T-plate fixation. Knee. 2011, 18: 278-284. 10.1016/j.knee.2010.05.009.CrossRefPubMed
24.
go back to reference Goulet JA, Senunas LE, DeSilva GL, Greenfield ML: Autogenous iliac crest bone graft. Complications and functional assessment. Clin Orthop Relat Res. 1997, 339: 76-81.CrossRefPubMed Goulet JA, Senunas LE, DeSilva GL, Greenfield ML: Autogenous iliac crest bone graft. Complications and functional assessment. Clin Orthop Relat Res. 1997, 339: 76-81.CrossRefPubMed
25.
go back to reference Valkering KP, van den Bekerom MP, Kappelhoff FM, Albers GH: Complications after tomofix medial opening wedge high tibial osteotomy. J Knee Surg. 2009, 22: 218-225. 10.1055/s-0030-1247752.CrossRefPubMed Valkering KP, van den Bekerom MP, Kappelhoff FM, Albers GH: Complications after tomofix medial opening wedge high tibial osteotomy. J Knee Surg. 2009, 22: 218-225. 10.1055/s-0030-1247752.CrossRefPubMed
26.
go back to reference Bhan S, Dave PK: High valgus tibial osteotomy for osteoarthritis of the knee. Int Orthop. 1992, 16: 13-17.CrossRefPubMed Bhan S, Dave PK: High valgus tibial osteotomy for osteoarthritis of the knee. Int Orthop. 1992, 16: 13-17.CrossRefPubMed
27.
go back to reference Spahn G: Complications in high tibial (medial opening wedge) osteotomy. Arch Orthop Trauma Surg. 2004, 124: 649-653. 10.1007/s00402-003-0588-7.CrossRefPubMed Spahn G: Complications in high tibial (medial opening wedge) osteotomy. Arch Orthop Trauma Surg. 2004, 124: 649-653. 10.1007/s00402-003-0588-7.CrossRefPubMed
28.
go back to reference Brinkman JM, Luites JW, Wymenga AB, van Heerwaarden RJ: Early full weight bearing is safe in open-wedge high tibial osteotomy. Acta Orthop. 2010, 81: 193-198. 10.3109/17453671003619003.CrossRefPubMedPubMedCentral Brinkman JM, Luites JW, Wymenga AB, van Heerwaarden RJ: Early full weight bearing is safe in open-wedge high tibial osteotomy. Acta Orthop. 2010, 81: 193-198. 10.3109/17453671003619003.CrossRefPubMedPubMedCentral
29.
go back to reference Takeuchi R, Aratake M, Bito H, Saito I, Kumagai K, Ishikawa H, Akamatsu Y, Sasaki Y, Saito T: Simultaneous bilateral opening-wedge high tibial osteotomy with early full weight-bearing exercise. Knee Surg Sports Traumatol Arthrosc. 2008, 16: 1030-1037. 10.1007/s00167-008-0609-8.CrossRefPubMed Takeuchi R, Aratake M, Bito H, Saito I, Kumagai K, Ishikawa H, Akamatsu Y, Sasaki Y, Saito T: Simultaneous bilateral opening-wedge high tibial osteotomy with early full weight-bearing exercise. Knee Surg Sports Traumatol Arthrosc. 2008, 16: 1030-1037. 10.1007/s00167-008-0609-8.CrossRefPubMed
30.
go back to reference Wilk KE, Escamilla RF, Fleisig GS, Barrentine SW, Andrews JR, Boyd ML: A comparison of tibiofemoral joint forces and electromyographic activity during open and closed kinetic chain exercises. Am J Sports Med. 1996, 24: 518-527. 10.1177/036354659602400418.CrossRefPubMed Wilk KE, Escamilla RF, Fleisig GS, Barrentine SW, Andrews JR, Boyd ML: A comparison of tibiofemoral joint forces and electromyographic activity during open and closed kinetic chain exercises. Am J Sports Med. 1996, 24: 518-527. 10.1177/036354659602400418.CrossRefPubMed
Metadata
Title
Comparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis
Authors
Мaxim L Golovakhа
Weniamin Orljanski
Karl-Peter Benedetto
Sergey Panchenko
Philippe Büchler
Philipp Henle
Emin Aghayev
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2014
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-15-230

Other articles of this Issue 1/2014

BMC Musculoskeletal Disorders 1/2014 Go to the issue