Comparison of surface roughness and hardness of three different brands of esthetic coated NiTi archwires: invitro study

Authors: Amira A. Aboalnaga, Amal M. El Shahawi

Published in: BMC Oral Health | Issue 1/2023

Login to get access

Abstract

Background

The purpose of the current in vitro study was to evaluate the surface roughness and hardness of three brands of as-received esthetic coated NiTi archwires and compare them with the same parameters after immersion in artificial saliva.

Methods

Three groups of 0.016 × 0.022 inch epoxy-coated NiTi orthodontic wires [Tooth tone coated NiTi (Ortho Technology, West Columbia, USA), EverWhite NiTi (American Orthodontics, Wisconsin, USA) and Nitanium Super Elastic Tooth Tone Plastic coated (Ortho Organizers, San Marcos, CA, USA)] were compared. Each group was subdivided into five as-received archwire specimens and five archwire specimens retrieved following immersion in artificial saliva for 28 days. Atomic force microscopy was used for analysis of average surface roughness (Sa). Hardness testing was performed using Digital Vickers hardness tester. ANOVA and Kruskal-Wallis tests were used for comparing the wire groups.

Results

The ranking of (Sa) values was as follows: Nitanium Ortho Organizers > Everwhite American Orthodontics > Tooth tone Ortho Technology (P > 0.05). Nitanium Ortho Organizers archwires showed significantly greater (Sa) than both other groups following immersion in saliva (P < 0.001). The coating hardness of as-received and post-immersion archwires from Tooth tone Ortho Technology was significantly lower than the other groups (P < 0.001). For all the three types of archwires, the mean hardness of immersed wires was significantly lower than that of the as-received archwires (P < 0.001).

Conclusions

Esthetic coated archwires have shown unpleasant surface changes following exposure to artificial saliva. These surface changes are affected by physical characteristics such as surface roughness and hardness of the coating.
Literature
1.
go back to reference -Hershey HG. The orthodontic appliance: esthetic considerations. J Am Dent Assoc. 1988;117:29E–34E.CrossRefPubMed -Hershey HG. The orthodontic appliance: esthetic considerations. J Am Dent Assoc. 1988;117:29E–34E.CrossRefPubMed
2.
go back to reference -Mousavi SM, Shamohammadi M, Rastegaar Z, Skini M, Rakhshan V. Effect of esthetic coating on surface roughness of orthodontic archwires. Int Orthod. 2017;15(3):312–21.CrossRefPubMed -Mousavi SM, Shamohammadi M, Rastegaar Z, Skini M, Rakhshan V. Effect of esthetic coating on surface roughness of orthodontic archwires. Int Orthod. 2017;15(3):312–21.CrossRefPubMed
4.
go back to reference -Ryu SH, Lim BS, Kwak EJ, Lee GJ, Choi S, Park KH. Surface ultrastructure and mechanical properties of three different white-coated NiTi archwires. Scanning. 2015;37(6):414–21.CrossRefPubMed -Ryu SH, Lim BS, Kwak EJ, Lee GJ, Choi S, Park KH. Surface ultrastructure and mechanical properties of three different white-coated NiTi archwires. Scanning. 2015;37(6):414–21.CrossRefPubMed
5.
go back to reference -Alavi S, Hosseini N. Load-deflection and surface properties of coated and conventional superelastic orthodontic archwires in conventional and metal-insert ceramic brackets. Dent Res J (Isfahan). 2012;9:133–8.CrossRefPubMed -Alavi S, Hosseini N. Load-deflection and surface properties of coated and conventional superelastic orthodontic archwires in conventional and metal-insert ceramic brackets. Dent Res J (Isfahan). 2012;9:133–8.CrossRefPubMed
6.
go back to reference -Lim KF, Lew KK, Toh SL. Bending stiffness of two aesthetic orthodontic archwires: an in vitro comparative study. Clin Mater. 1994;16:63–71.CrossRefPubMed -Lim KF, Lew KK, Toh SL. Bending stiffness of two aesthetic orthodontic archwires: an in vitro comparative study. Clin Mater. 1994;16:63–71.CrossRefPubMed
7.
go back to reference -Kusy RP, Whitley JQ. Effects of surface roughness on the coefficients of friction in model orthodontic systems. J Biomech. 1990;23:913–25.CrossRefPubMed -Kusy RP, Whitley JQ. Effects of surface roughness on the coefficients of friction in model orthodontic systems. J Biomech. 1990;23:913–25.CrossRefPubMed
8.
go back to reference -Da Silva DL, Mattos CT, Simão RA, de Oliveira Ruellas AC. Coating stability and surface characteristics of esthetic orthodontic coated archwires. Angle Orthod. 2013;83(6):994–1001.CrossRefPubMedPubMedCentral -Da Silva DL, Mattos CT, Simão RA, de Oliveira Ruellas AC. Coating stability and surface characteristics of esthetic orthodontic coated archwires. Angle Orthod. 2013;83(6):994–1001.CrossRefPubMedPubMedCentral
9.
go back to reference -Elayyan F, Silikas N, Bearn D. Ex vivo surface and mechanical properties of coated orthodontic archwires. Eur J Orthod. 2008;30:661–7.CrossRefPubMed -Elayyan F, Silikas N, Bearn D. Ex vivo surface and mechanical properties of coated orthodontic archwires. Eur J Orthod. 2008;30:661–7.CrossRefPubMed
10.
go back to reference -Bourauel C, Fries T, Drescher D, Plietsch R. Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry. Eur J Orthod. 1998;20:79–92.CrossRefPubMed -Bourauel C, Fries T, Drescher D, Plietsch R. Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry. Eur J Orthod. 1998;20:79–92.CrossRefPubMed
11.
go back to reference -Da Silva DL, Santos E Jr, Camargo Sde S Jr, Ruellas AC. Infrared spectroscopy, nano-mechanical properties, and scratch resistance of esthetic orthodontic coated archwires. Angle Orthod. 2015;85(5):777–83.CrossRefPubMed -Da Silva DL, Santos E Jr, Camargo Sde S Jr, Ruellas AC. Infrared spectroscopy, nano-mechanical properties, and scratch resistance of esthetic orthodontic coated archwires. Angle Orthod. 2015;85(5):777–83.CrossRefPubMed
12.
go back to reference -Venkatesan K, Kailasam V, Padmanabhan S. Evaluation of titanium dioxide coating on surface roughness of nickel-titanium archwires and its influence on Streptococcus mutans adhesion and enamel mineralization: a prospective clinical study. Am J Orthod Dentofacial Orthop. 2020;158(2):199–208.CrossRefPubMed -Venkatesan K, Kailasam V, Padmanabhan S. Evaluation of titanium dioxide coating on surface roughness of nickel-titanium archwires and its influence on Streptococcus mutans adhesion and enamel mineralization: a prospective clinical study. Am J Orthod Dentofacial Orthop. 2020;158(2):199–208.CrossRefPubMed
13.
go back to reference -Kim H, Johnson JW. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires. Angle Orthod. 1999;69:39–44.PubMed -Kim H, Johnson JW. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires. Angle Orthod. 1999;69:39–44.PubMed
14.
go back to reference -Huang HH. Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva. J Biomed Mater Res A. 2003;66:829–39.CrossRefPubMed -Huang HH. Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva. J Biomed Mater Res A. 2003;66:829–39.CrossRefPubMed
17.
go back to reference -Xu JL, Lai T, Luo JM. Preparation and characterization of the aesthetic coating on nickel-titanium orthodontic archwire by electrophoretic deposition. Prog Org Coat. 2019;137:105271.CrossRef -Xu JL, Lai T, Luo JM. Preparation and characterization of the aesthetic coating on nickel-titanium orthodontic archwire by electrophoretic deposition. Prog Org Coat. 2019;137:105271.CrossRef
18.
go back to reference -Zinelis S, Al Jabbari YS, Gaintantzopoulou M, Eliades G, Eliades T. Mechanical properties of orthodontic wires derived by instrumented indentation testing (IIT) according to ISO 14577. Prog Orthod. 2015;16:19.CrossRefPubMedPubMedCentral -Zinelis S, Al Jabbari YS, Gaintantzopoulou M, Eliades G, Eliades T. Mechanical properties of orthodontic wires derived by instrumented indentation testing (IIT) according to ISO 14577. Prog Orthod. 2015;16:19.CrossRefPubMedPubMedCentral
19.
go back to reference -Daems J, Celis JP, Willems G. Morphological characterization of as-received and in vivo orthodontic stainless steel archwires. Eur J Orthod. 2009;31:260–5.CrossRefPubMed -Daems J, Celis JP, Willems G. Morphological characterization of as-received and in vivo orthodontic stainless steel archwires. Eur J Orthod. 2009;31:260–5.CrossRefPubMed
20.
go back to reference -Lee GJ, Park KH, Park YG, Park HK. A quantitative AFM analysis of nano-scale surface roughness in various orthodontic brackets. Micron. 2010;41:775–82.CrossRefPubMed -Lee GJ, Park KH, Park YG, Park HK. A quantitative AFM analysis of nano-scale surface roughness in various orthodontic brackets. Micron. 2010;41:775–82.CrossRefPubMed
21.
go back to reference -Rongo R, Ametrano G, Gloria A, Spagnuolo G, Galeotti A, Paduano S, Valletta R, D’Anto` V. Effects of intraoral aging on surface properties of coated nickel-titanium archwires. Angle Orthod. 2013;84:665–72.CrossRefPubMedPubMedCentral -Rongo R, Ametrano G, Gloria A, Spagnuolo G, Galeotti A, Paduano S, Valletta R, D’Anto` V. Effects of intraoral aging on surface properties of coated nickel-titanium archwires. Angle Orthod. 2013;84:665–72.CrossRefPubMedPubMedCentral
22.
go back to reference -Iijima M, Muguruma T, Brantley W, Choe HC, Nakagaki S, Alapati SB, Mizoguchi I. Effect of coating on properties of esthetic orthodontic nickel-titanium wires. Angle Orthod. 2011;82:319–25.CrossRefPubMedPubMedCentral -Iijima M, Muguruma T, Brantley W, Choe HC, Nakagaki S, Alapati SB, Mizoguchi I. Effect of coating on properties of esthetic orthodontic nickel-titanium wires. Angle Orthod. 2011;82:319–25.CrossRefPubMedPubMedCentral
23.
go back to reference -Zegan G, Sodor A, Munteanu C. Surface characteristics of retrieved coated and nickel-titanium orthodontic archwires. Rom J Morphol Embryol. 2012;53:935–9.PubMed -Zegan G, Sodor A, Munteanu C. Surface characteristics of retrieved coated and nickel-titanium orthodontic archwires. Rom J Morphol Embryol. 2012;53:935–9.PubMed
24.
go back to reference -Abdulkader YC, Kamaruddin AF, Mydin RBSMN. Effects of salivary pH on coating durability of two different aesthetic archwire coatings under a simulated intraoral environment. Saudi Dent J. 2020;32(6):306–13.CrossRefPubMed -Abdulkader YC, Kamaruddin AF, Mydin RBSMN. Effects of salivary pH on coating durability of two different aesthetic archwire coatings under a simulated intraoral environment. Saudi Dent J. 2020;32(6):306–13.CrossRefPubMed
25.
go back to reference -Ulhaq A, Esmail Z, Kamaruddin A, Meadows S, Daus J, Vitale M, Perillo L, Sherriff M, Bister D. Alignment efficiency and esthetic performance of 4 coated nickel-titanium archwires in orthodontic patients over 8 weeks: a multicenter randomized clinical trial. Am J Orthod Dentofacial Orthop. 2017;152:744–52.CrossRefPubMed -Ulhaq A, Esmail Z, Kamaruddin A, Meadows S, Daus J, Vitale M, Perillo L, Sherriff M, Bister D. Alignment efficiency and esthetic performance of 4 coated nickel-titanium archwires in orthodontic patients over 8 weeks: a multicenter randomized clinical trial. Am J Orthod Dentofacial Orthop. 2017;152:744–52.CrossRefPubMed
26.
go back to reference -Kang WS, Rhee KY, Park SJ. Influence of surface energetics of graphene oxide on fracture toughness of epoxy nanocomposites. Compos B Eng. 2017;114:175–83.CrossRef -Kang WS, Rhee KY, Park SJ. Influence of surface energetics of graphene oxide on fracture toughness of epoxy nanocomposites. Compos B Eng. 2017;114:175–83.CrossRef
27.
go back to reference -Li Y, Xue B. Hydrothermal ageing mechanisms of unidirectional flax fabric reinforced epoxy composites. Polym Degrad Stab. 2016;126:144–58.CrossRef -Li Y, Xue B. Hydrothermal ageing mechanisms of unidirectional flax fabric reinforced epoxy composites. Polym Degrad Stab. 2016;126:144–58.CrossRef
28.
go back to reference -Kusy, Robert P, John Q, Whitley. Friction between different wire-bracket configurations and materials. Seminars in Orthodontics, Vol. 3. No. 3. WB Saunders, 1997. -Kusy, Robert P, John Q, Whitley. Friction between different wire-bracket configurations and materials. Seminars in Orthodontics, Vol. 3. No. 3. WB Saunders, 1997.
29.
go back to reference -Eliades T, Bourauel C. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance. Am J Orthod Dentofacial Orthop. 2005;127(4):403–12.CrossRefPubMed -Eliades T, Bourauel C. Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance. Am J Orthod Dentofacial Orthop. 2005;127(4):403–12.CrossRefPubMed
30.
go back to reference -Rudge P, Sherriff M, Bister D. A comparison of roughness parameters and friction coefficients of aesthetic archwires. Eur J Orthod. 2015;37(1):49–55.CrossRefPubMed -Rudge P, Sherriff M, Bister D. A comparison of roughness parameters and friction coefficients of aesthetic archwires. Eur J Orthod. 2015;37(1):49–55.CrossRefPubMed
31.
go back to reference -Chng CK, Foong K, Gandedkar NH, Chan YH, Chew CL. A new esthetic fiber-reinforced polymer composite resin archwire: a comparative atomic force microscope (AFM) and field-emission scanning electron microscope (FESEM) study. Prog Orthod. 2014;15:39.CrossRefPubMedPubMedCentral -Chng CK, Foong K, Gandedkar NH, Chan YH, Chew CL. A new esthetic fiber-reinforced polymer composite resin archwire: a comparative atomic force microscope (AFM) and field-emission scanning electron microscope (FESEM) study. Prog Orthod. 2014;15:39.CrossRefPubMedPubMedCentral
Metadata
Title
Comparison of surface roughness and hardness of three different brands of esthetic coated NiTi archwires: invitro study
Authors
Amira A. Aboalnaga
Amal M. El Shahawi
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-03497-8

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue