Abstract

Purpose

The goal of this study was to compare the kinematics of knees before and after total knee arthroplasty (TKA) that relies on an inter-condylar ‘third condyle’. The hypothesis was that the ‘third condyle’ provides sufficient flexion stability and induces a close to normal femoral rollback, thus granting natural joint kinematics.

Methods

Intra-operative navigation data were collected from 29 consecutive cases that received a cemented TKA (HLS Noetos, Tornier SA, France) designed with an inter-condylar ‘third condyle’ that engages within the tibial insert beyond 35° flexion. Operations were guided by a non-image-based system (BLU-IGS, Orthokey Italia srl, Italy) that recorded relative femoral and tibial positions in native and implanted knees during: passive range of motion, anterior drawer test at 90° flexion, and varus–valgus stress tests at full extension and at 30° flexion.

Results

The total internal tibial rotation during flexion was similar for native (8.2 ± 4.2°) and implanted knees (8.0 ± 5.4°). The lateral femoral condyle was more posterior in implanted knees (1.2 ± 9.4 mm) than in native knees (9.5 ± 3.6 mm) throughout early flexion (p < 0.01), but this difference diminished beyond 100° flexion (n.s.). The implanted knees did not exhibit paradoxical external tibial rotation. Varus–valgus laxity in full extension was lower for implanted knees than for native knees (p = 0.0221), but at 30° flexion was almost identical for both native and implanted knees. Anteroposterior laxity was similar in implanted and native knees.

Conclusions

The ‘third condyle’ TKA provides similar anteroposterior and mediolateral stability to the natural knee. This feature granted an adequate balance between laxity and constraint to reproduce natural joint kinematics, including smooth femoral rollback, without causing paradoxical external tibial rotation.

Level of evidence

Comparative study, Level III.
Literature
1.
go back to reference Argenson J-NA, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac J-M (2005) In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 38:277–284PubMedCrossRef Argenson J-NA, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac J-M (2005) In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 38:277–284PubMedCrossRef
2.
go back to reference Baier C, Springorum H-R, Götz J, Schaumburger J, Lüring C, Grifka J, Beckmann J (2013) Comparing navigation-based in vivo knee kinematics pre- and postoperatively between a cruciate-retaining and a cruciate-substituting implant. Int Orthop 37:407–414PubMedCentralPubMedCrossRef Baier C, Springorum H-R, Götz J, Schaumburger J, Lüring C, Grifka J, Beckmann J (2013) Comparing navigation-based in vivo knee kinematics pre- and postoperatively between a cruciate-retaining and a cruciate-substituting implant. Int Orthop 37:407–414PubMedCentralPubMedCrossRef
3.
go back to reference Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304PubMedCrossRef Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304PubMedCrossRef
4.
go back to reference Barink M, Meijerink H, Verdonschot N, Kampen A, Waal Malefijt M (2007) Asymmetrical total knee arthroplasty does not improve patella tracking: a study without patella resurfacing. Knee Surg Sports Traumatol Arthrosc 15:184–191PubMedCrossRef Barink M, Meijerink H, Verdonschot N, Kampen A, Waal Malefijt M (2007) Asymmetrical total knee arthroplasty does not improve patella tracking: a study without patella resurfacing. Knee Surg Sports Traumatol Arthrosc 15:184–191PubMedCrossRef
5.
go back to reference Bellemans J, Robijns F, Duerinckx J, Banks S, Vandenneucker H (2005) The influence of tibial slope on maximal flexion after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 13:193–196PubMedCrossRef Bellemans J, Robijns F, Duerinckx J, Banks S, Vandenneucker H (2005) The influence of tibial slope on maximal flexion after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 13:193–196PubMedCrossRef
6.
go back to reference Belvedere C, Ensini A, Leardini A, Dedda V, Feliciangeli A, Cenni F, Timoncini A, Barbadoro P, Giannini S (2014) Tibio-femoral and patello-femoral joint kinematics during navigated total knee arthroplasty with patellar resurfacing. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-013-2825-0 Belvedere C, Ensini A, Leardini A, Dedda V, Feliciangeli A, Cenni F, Timoncini A, Barbadoro P, Giannini S (2014) Tibio-femoral and patello-femoral joint kinematics during navigated total knee arthroplasty with patellar resurfacing. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-013-2825-0
7.
go back to reference Belvedere C, Tamarri S, Notarangelo DP, Ensini A, Feliciangeli A, Leardini A (2013) Three-dimensional motion analysis of the human knee joint: comparison between intra- and post-operative measurements. Knee Surg Sports Traumatol Arthrosc 21:2375–2383PubMedCrossRef Belvedere C, Tamarri S, Notarangelo DP, Ensini A, Feliciangeli A, Leardini A (2013) Three-dimensional motion analysis of the human knee joint: comparison between intra- and post-operative measurements. Knee Surg Sports Traumatol Arthrosc 21:2375–2383PubMedCrossRef
8.
go back to reference Bignozzi S, Lopomo N, Zaffagnini S, Martelli S, Bruni D, Marcacci M (2008) Accuracy, reliability, and repeatability of navigation systems in clinical practice. Oper Tech Orthop 18:154–157CrossRef Bignozzi S, Lopomo N, Zaffagnini S, Martelli S, Bruni D, Marcacci M (2008) Accuracy, reliability, and repeatability of navigation systems in clinical practice. Oper Tech Orthop 18:154–157CrossRef
9.
go back to reference Callaghan JJ, O’Rourke MR, Goetz DD, Schmalzried TP, Campbell PA, Johnston RC (2002) Tibial post impingement in posterior-stabilized total knee arthroplasty. Clin Orthop Relat Res 404:83–88 Callaghan JJ, O’Rourke MR, Goetz DD, Schmalzried TP, Campbell PA, Johnston RC (2002) Tibial post impingement in posterior-stabilized total knee arthroplasty. Clin Orthop Relat Res 404:83–88
10.
go back to reference Casino D, Zaffagnini S, Martelli S, Lopomo N, Bignozzi S, Iacono F, Russo A, Marcacci M (2009) Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system. Knee Surg Sports Traumatol Arthrosc 17:369–373PubMedCrossRef Casino D, Zaffagnini S, Martelli S, Lopomo N, Bignozzi S, Iacono F, Russo A, Marcacci M (2009) Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system. Knee Surg Sports Traumatol Arthrosc 17:369–373PubMedCrossRef
11.
go back to reference Cates HE, Komistek RD, Mahfouz MR, Schmidt MA, Anderle M (2008) In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty. J Arthroplasty 23:1057–1067PubMedCrossRef Cates HE, Komistek RD, Mahfouz MR, Schmidt MA, Anderle M (2008) In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty. J Arthroplasty 23:1057–1067PubMedCrossRef
12.
go back to reference Clarke HD, Math KR, Scuderi GR (2004) Polyethylene post failure in posterior stabilized total knee arthroplasty. J Arthroplasty 19:652–657PubMedCrossRef Clarke HD, Math KR, Scuderi GR (2004) Polyethylene post failure in posterior stabilized total knee arthroplasty. J Arthroplasty 19:652–657PubMedCrossRef
13.
go back to reference Cromie MJ, Siston RA, Giori NJ, Delp SL (2008) Posterior cruciate ligament removal contributes to abnormal knee motion during posterior stabilized total knee arthroplasty. J Orthop Res 26:1494–1499PubMedCrossRef Cromie MJ, Siston RA, Giori NJ, Delp SL (2008) Posterior cruciate ligament removal contributes to abnormal knee motion during posterior stabilized total knee arthroplasty. J Orthop Res 26:1494–1499PubMedCrossRef
14.
go back to reference Delport HP, Banks SA, De Schepper J, Bellemans J (2006) A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Joint Surg Br 88:1016–1021PubMedCrossRef Delport HP, Banks SA, De Schepper J, Bellemans J (2006) A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Joint Surg Br 88:1016–1021PubMedCrossRef
15.
go back to reference Dennis DA, Komistek RD, Hoff WA, Gabriel SM (1996) In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop Relat Res 331:107–117 Dennis DA, Komistek RD, Hoff WA, Gabriel SM (1996) In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop Relat Res 331:107–117
16.
go back to reference Dennis DA, Komistek RD, Mahfouz MR, Haas BD, Stiehl JB (2003) Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57 Dennis DA, Komistek RD, Mahfouz MR, Haas BD, Stiehl JB (2003) Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57
17.
go back to reference Ezechieli M, Dietzek J, Becher C, Ettinger M, Calliess T, Ostermeier S, Windhagen H (2012) The influence of a single-radius-design on the knee stability. Technol Health Care 20:527–534PubMed Ezechieli M, Dietzek J, Becher C, Ettinger M, Calliess T, Ostermeier S, Windhagen H (2012) The influence of a single-radius-design on the knee stability. Technol Health Care 20:527–534PubMed
18.
go back to reference Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144PubMedCrossRef Grood ES, Suntay WJ (1983) A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng 105:136–144PubMedCrossRef
19.
go back to reference Hall J, Copp SN, Adelson WS, D’Lima DD, Colwell CW Jr (2008) Extensor mechanism function in single-radius vs multiradius femoral components for total knee arthroplasty. J Arthroplasty 23:216–219PubMedCrossRef Hall J, Copp SN, Adelson WS, D’Lima DD, Colwell CW Jr (2008) Extensor mechanism function in single-radius vs multiradius femoral components for total knee arthroplasty. J Arthroplasty 23:216–219PubMedCrossRef
20.
go back to reference Hanson GR, Suggs JF, Kwon Y-M, Freiberg AA, Li G (2007) In vivo anterior tibial post contact after posterior stabilizing total knee arthroplasty. J Orthop Res 25:1447–1453PubMedCrossRef Hanson GR, Suggs JF, Kwon Y-M, Freiberg AA, Li G (2007) In vivo anterior tibial post contact after posterior stabilizing total knee arthroplasty. J Orthop Res 25:1447–1453PubMedCrossRef
21.
go back to reference Hollinghurst D, Stoney J, Ward T, Pandit H, Beard D, Murray DW (2007) In vivo sagittal plane kinematics of the Avon patellofemoral arthroplasty. J Arthroplasty 22:117–123PubMedCrossRef Hollinghurst D, Stoney J, Ward T, Pandit H, Beard D, Murray DW (2007) In vivo sagittal plane kinematics of the Avon patellofemoral arthroplasty. J Arthroplasty 22:117–123PubMedCrossRef
22.
go back to reference Iwaki H, Pinskerova V, Freeman MA (2000) Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br 82:1189–1195PubMedCrossRef Iwaki H, Pinskerova V, Freeman MA (2000) Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br 82:1189–1195PubMedCrossRef
23.
go back to reference Klein GR, Parvizi J, Rapuri VR, Austin MS, Hozack WJ (2004) The effect of tibial polyethylene insert design on range of motion: evaluation of in vivo knee kinematics by a computerized navigation system during total knee arthroplasty. J Arthroplasty 19:986–991PubMed Klein GR, Parvizi J, Rapuri VR, Austin MS, Hozack WJ (2004) The effect of tibial polyethylene insert design on range of motion: evaluation of in vivo knee kinematics by a computerized navigation system during total knee arthroplasty. J Arthroplasty 19:986–991PubMed
24.
go back to reference Lin K-J, Huang C-H, Liu Y-L, Chen W-C, Chang T-W, Yang C-T, Lai Y-S, Cheng C-K (2011) Influence of post-cam design of posterior stabilized knee prosthesis on tibiofemoral motion during high knee flexion. Clin Biomech (Bristol, Avon) 26:847–852CrossRef Lin K-J, Huang C-H, Liu Y-L, Chen W-C, Chang T-W, Yang C-T, Lai Y-S, Cheng C-K (2011) Influence of post-cam design of posterior stabilized knee prosthesis on tibiofemoral motion during high knee flexion. Clin Biomech (Bristol, Avon) 26:847–852CrossRef
25.
go back to reference Lüring C, Oczipka F, Perlick L, Tingart M, Grifka J, Bäthis H (2009) Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction. Knee Surg Sports Traumatol Arthrosc 17:228–232PubMedCrossRef Lüring C, Oczipka F, Perlick L, Tingart M, Grifka J, Bäthis H (2009) Two year follow-up comparing computer assisted versus freehand TKR on joint stability, muscular function and patients satisfaction. Knee Surg Sports Traumatol Arthrosc 17:228–232PubMedCrossRef
26.
go back to reference Martelli S, Zaffagnini S, Bignozzi S, Bontempi M, Marcacci M (2006) Validation of a new protocol for computer-assisted evaluation of kinematics of double-bundle ACL reconstruction. Clin Biomech (Bristol, Avon) 21:279–287CrossRef Martelli S, Zaffagnini S, Bignozzi S, Bontempi M, Marcacci M (2006) Validation of a new protocol for computer-assisted evaluation of kinematics of double-bundle ACL reconstruction. Clin Biomech (Bristol, Avon) 21:279–287CrossRef
27.
go back to reference Mihalko WM, Ali M, Phillips MJ, Bayers-Thering M, Krackow KA (2008) Passive knee kinematics before and after total knee arthroplasty: are we correcting pathologic motion? J Arthroplasty 23:57–60PubMedCrossRef Mihalko WM, Ali M, Phillips MJ, Bayers-Thering M, Krackow KA (2008) Passive knee kinematics before and after total knee arthroplasty: are we correcting pathologic motion? J Arthroplasty 23:57–60PubMedCrossRef
28.
go back to reference Pandit H, Ward T, Hollinghurst D, Beard DJ, Gill HS, Thomas NP, Murray DW (2005) Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement. J Bone Joint Surg Br 87:940–945PubMedCrossRef Pandit H, Ward T, Hollinghurst D, Beard DJ, Gill HS, Thomas NP, Murray DW (2005) Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement. J Bone Joint Surg Br 87:940–945PubMedCrossRef
29.
go back to reference Paterson NR, Teeter MG, MacDonald SJ, McCalden RW, Naudie DDR (2013) The 2012 Mark Coventry award: a retrieval analysis of high flexion versus posterior-stabilized tibial inserts. Clin Orthop Relat Res 471:56–63PubMedCentralPubMedCrossRef Paterson NR, Teeter MG, MacDonald SJ, McCalden RW, Naudie DDR (2013) The 2012 Mark Coventry award: a retrieval analysis of high flexion versus posterior-stabilized tibial inserts. Clin Orthop Relat Res 471:56–63PubMedCentralPubMedCrossRef
30.
go back to reference Picard F, Deakin AH, Clarke IV, Dillon JM, Kinninmonth AW (2007) A quantitative method of effective soft tissue management for varus knees in total knee replacement surgery using navigational techniques. Proc Inst Mech Eng H 221:763–772PubMedCrossRef Picard F, Deakin AH, Clarke IV, Dillon JM, Kinninmonth AW (2007) A quantitative method of effective soft tissue management for varus knees in total knee replacement surgery using navigational techniques. Proc Inst Mech Eng H 221:763–772PubMedCrossRef
31.
go back to reference Puloski SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB (2001) Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris. J Bone Joint Surg Am 83-A:390–397PubMed Puloski SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB (2001) Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris. J Bone Joint Surg Am 83-A:390–397PubMed
32.
go back to reference Seon J-K, Park J-K, Shin Y-J, Seo H-Y, Lee K-B, Song E-K (2011) Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs. substituting designs. Knee Surg Sports Traumatol Arthrosc 19:2016–2022PubMedCrossRef Seon J-K, Park J-K, Shin Y-J, Seo H-Y, Lee K-B, Song E-K (2011) Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs. substituting designs. Knee Surg Sports Traumatol Arthrosc 19:2016–2022PubMedCrossRef
33.
go back to reference Shi X, Shen B, Yang J, Kang P, Zhou Z, Pei F (2012) In vivo kinematics comparison of fixed- and mobile-bearing total knee arthroplasty during deep knee bending motion. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-012-2333-7 Shi X, Shen B, Yang J, Kang P, Zhou Z, Pei F (2012) In vivo kinematics comparison of fixed- and mobile-bearing total knee arthroplasty during deep knee bending motion. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-012-2333-7
34.
go back to reference Siston RA, Giori NJ, Goodman SB, Delp SL (2006) Intraoperative passive kinematics of osteoarthritic knees before and after total knee arthroplasty. J Orthop Res 24:1607–1614PubMedCrossRef Siston RA, Giori NJ, Goodman SB, Delp SL (2006) Intraoperative passive kinematics of osteoarthritic knees before and after total knee arthroplasty. J Orthop Res 24:1607–1614PubMedCrossRef
35.
36.
go back to reference Stoddard JE, Deehan DJ, Bull AMJ, McCaskie AW, Amis AA (2013) The kinematics and stability of single-radius versus multi-radius femoral components related to mid-range instability after TKA. J Orthop Res 31:53–58PubMedCrossRef Stoddard JE, Deehan DJ, Bull AMJ, McCaskie AW, Amis AA (2013) The kinematics and stability of single-radius versus multi-radius femoral components related to mid-range instability after TKA. J Orthop Res 31:53–58PubMedCrossRef
37.
go back to reference Suggs JF, Hanson GR, Park SE, Moynihan AL, Li G (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16:290–296PubMedCrossRef Suggs JF, Hanson GR, Park SE, Moynihan AL, Li G (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16:290–296PubMedCrossRef
38.
go back to reference Tamaki M, Tomita T, Watanabe T, Yamazaki T, Yoshikawa H, Sugamoto K (2009) In vivo kinematic analysis of a high-flexion, posterior-stabilized, mobile-bearing knee prosthesis in deep knee bending motion. J Arthroplasty 24:972–978PubMedCrossRef Tamaki M, Tomita T, Watanabe T, Yamazaki T, Yoshikawa H, Sugamoto K (2009) In vivo kinematic analysis of a high-flexion, posterior-stabilized, mobile-bearing knee prosthesis in deep knee bending motion. J Arthroplasty 24:972–978PubMedCrossRef
39.
go back to reference Tayot O, Aït Si Selmi T, Neyret P (2001) Results at 11.5 years of a series of 376 posterior stabilized HLS1 total knee replacements. Survivorship analysis, and risk factors for failure. Knee 8:195–205PubMedCrossRef Tayot O, Aït Si Selmi T, Neyret P (2001) Results at 11.5 years of a series of 376 posterior stabilized HLS1 total knee replacements. Survivorship analysis, and risk factors for failure. Knee 8:195–205PubMedCrossRef
40.
go back to reference Walker PS, Heller Y, Yildirim G, Immerman I (2011) Reference axes for comparing the motion of knee replacements with the anatomic knee. Knee 18:312–316PubMedCrossRef Walker PS, Heller Y, Yildirim G, Immerman I (2011) Reference axes for comparing the motion of knee replacements with the anatomic knee. Knee 18:312–316PubMedCrossRef
41.
go back to reference Wolterbeek N, Nelissen RGHH, Valstar ER (2012) No differences in in vivo kinematics between six different types of knee prostheses. Knee Surg Sports Traumatol Arthrosc 20:559–564PubMedCentralPubMedCrossRef Wolterbeek N, Nelissen RGHH, Valstar ER (2012) No differences in in vivo kinematics between six different types of knee prostheses. Knee Surg Sports Traumatol Arthrosc 20:559–564PubMedCentralPubMedCrossRef
42.
go back to reference Yue B, Varadarajan KM, Moynihan AL, Liu F, Rubash HE, Li G (2011) Kinematics of medial osteoarthritic knees before and after posterior cruciate ligament retaining total knee arthroplasty. J Orthop Res 29:40–46PubMedCrossRef Yue B, Varadarajan KM, Moynihan AL, Liu F, Rubash HE, Li G (2011) Kinematics of medial osteoarthritic knees before and after posterior cruciate ligament retaining total knee arthroplasty. J Orthop Res 29:40–46PubMedCrossRef
Metadata
Title
Comparison of stability and kinematics of the natural knee versus a PS TKA with a ‘third condyle’
Authors
Stefano Zaffagnini
Simone Bignozzi
Mo Saffarini
Francesca Colle
Bharat Sharma
Plamen Slavov Kinov
Maurilio Marcacci
David Dejour
Publication date
01-08-2014
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 8/2014
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-014-3016-3

Other articles of this Issue 8/2014

Knee Surgery, Sports Traumatology, Arthroscopy 8/2014 Go to the issue