Skip to main content
Top
Published in: Breast Cancer Research and Treatment 3/2016

01-02-2016 | Clinical trial

Comparison of intra-operative specimen mammography to standard specimen mammography for excision of non-palpable breast lesions: a randomized trial

Authors: Cynthia L. Miller, Suzanne B. Coopey, Elizabeth Rafferty, Michele Gadd, Barbara L. Smith, Michelle C. Specht

Published in: Breast Cancer Research and Treatment | Issue 3/2016

Login to get access

Abstract

Standard specimen mammography (SSM) is performed in the radiology department after wire-localized excision of non-palpable breast lesions to confirm the presence of the target and evaluate margins. Alternatively, intra-operative specimen mammography (ISM) allows surgeons to view images in the operating room (OR). We conducted a randomized study comparing ISM and SSM. Women undergoing wire-localized excision for breast malignancy or imaging abnormality were randomized to SSM or ISM. For SSM, the specimen was transported to the radiology department for imaging and interpretation. For ISM, the specimen was imaged in the OR for interpretation by the surgeon and sent for SSM. Interpretation time was from specimen leaving OR until radiologist interpretation for SSM and from placement in ISM device until surgeon interpretation for ISM. Procedure and interpretation times were compared. Concordance between ISM and SSM for target and margins was evaluated. 72 patients were randomized, 36 ISM and 36 SSM. Median procedure times were similar, 48.5 (17–138) min for ISM, and 54 (17–40) min for SSM (p = 0.72), likely since specimens in both groups traveled to radiology for SSM. Median interpretation time was significantly shorter with ISM, 1 (0.5–2.0) and 9 (4–16) min for ISM and SSM, respectively (p < 0.0001). Among specimens with ISM and SSM, concordance was 100 % (35/35) for target and 93 % (14/15) for margins. In this randomized trial, use of ISM compared with SSM significantly reduced interpretation times, while accurately identifying the target. This could result in decreased operative costs from shorter OR times with use of ISM.
Literature
2.
go back to reference della Rovere GQ, Benson JR, Morgan M, Warren R, Patel A (1996) Localization of impalpable breast lesions–a surgical approach. Eur J Surg Oncol 22(5):478–482CrossRefPubMed della Rovere GQ, Benson JR, Morgan M, Warren R, Patel A (1996) Localization of impalpable breast lesions–a surgical approach. Eur J Surg Oncol 22(5):478–482CrossRefPubMed
3.
go back to reference Silverstein MJ, Gamagami P, Rosser RJ, Gierson ED, Colburn WJ, Handel N, Fingerhut AG, Lewinsky BS, Hoffman RS, Waisman JR (1987) Hooked-wire-directed breast biopsy and overpenetrated mammography. Cancer 59(4):715–722CrossRefPubMed Silverstein MJ, Gamagami P, Rosser RJ, Gierson ED, Colburn WJ, Handel N, Fingerhut AG, Lewinsky BS, Hoffman RS, Waisman JR (1987) Hooked-wire-directed breast biopsy and overpenetrated mammography. Cancer 59(4):715–722CrossRefPubMed
4.
go back to reference Besic N, Zgajnar J, Hocevar M, Rener M, Frkovic-Grazio S, Snoj N, Lindtner J (2002) Breast biopsy with wire localization: factors influencing complete excision of nonpalpable carcinoma. Eur Radiol 12(11):2684–2689. doi:10.1007/s00330-002-1331-4 PubMed Besic N, Zgajnar J, Hocevar M, Rener M, Frkovic-Grazio S, Snoj N, Lindtner J (2002) Breast biopsy with wire localization: factors influencing complete excision of nonpalpable carcinoma. Eur Radiol 12(11):2684–2689. doi:10.​1007/​s00330-002-1331-4 PubMed
5.
go back to reference Kaufman CS, Jacobson L, Bachman BA, Kaufman LB, Mahon C, Gambrell LJ, Seymour R, Briscoe J, Aulisio K, Cunningham A, Opstad F, Schnell N, Robertson J, Oliver L (2007) Intraoperative digital specimen mammography: rapid, accurate results expedite surgery. Ann Surg Oncol 14(4):1478–1485. doi:10.1245/s10434-006-9126-5 CrossRefPubMed Kaufman CS, Jacobson L, Bachman BA, Kaufman LB, Mahon C, Gambrell LJ, Seymour R, Briscoe J, Aulisio K, Cunningham A, Opstad F, Schnell N, Robertson J, Oliver L (2007) Intraoperative digital specimen mammography: rapid, accurate results expedite surgery. Ann Surg Oncol 14(4):1478–1485. doi:10.​1245/​s10434-006-9126-5 CrossRefPubMed
7.
8.
go back to reference Bathla L, Harris A, Davey M, Sharma P, Silva E (2011) High resolution intra-operative two-dimensional specimen mammography and its impact on second operation for re-excision of positive margins at final pathology after breast conservation surgery. Am J Surg 202(4):387–394. doi:10.1016/j.amjsurg.2010.09.031 CrossRefPubMed Bathla L, Harris A, Davey M, Sharma P, Silva E (2011) High resolution intra-operative two-dimensional specimen mammography and its impact on second operation for re-excision of positive margins at final pathology after breast conservation surgery. Am J Surg 202(4):387–394. doi:10.​1016/​j.​amjsurg.​2010.​09.​031 CrossRefPubMed
9.
go back to reference Kim SH, Cornacchi SD, Heller B, Farrokhyar F, Babra M, Lovrics PJ (2013) An evaluation of intraoperative digital specimen mammography versus conventional specimen radiography for the excision of nonpalpable breast lesions. Am J Surg 205(6):703–710. doi:10.1016/j.amjsurg.2012.08.010 CrossRefPubMed Kim SH, Cornacchi SD, Heller B, Farrokhyar F, Babra M, Lovrics PJ (2013) An evaluation of intraoperative digital specimen mammography versus conventional specimen radiography for the excision of nonpalpable breast lesions. Am J Surg 205(6):703–710. doi:10.​1016/​j.​amjsurg.​2012.​08.​010 CrossRefPubMed
10.
go back to reference Wang Y, Ebuoma L, Saksena M, Liu B, Specht M, Rafferty E (2014) Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification. AJR Am J Roentgenol 203(2):457–462. doi:10.2214/AJR.13.11408 CrossRefPubMed Wang Y, Ebuoma L, Saksena M, Liu B, Specht M, Rafferty E (2014) Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification. AJR Am J Roentgenol 203(2):457–462. doi:10.​2214/​AJR.​13.​11408 CrossRefPubMed
11.
go back to reference Muttalib M, Sinnett HD (2006) Re: Power et al. needle-localised biopsy of impalpable breast lesions: a novel adjunct to surgical technique and specimen mammography. Surg J R Coll Surg Edinb Irel 2004; 2(6): 343–345. Surg J R Coll Surg Edinb Irel 4(1):60 Muttalib M, Sinnett HD (2006) Re: Power et al. needle-localised biopsy of impalpable breast lesions: a novel adjunct to surgical technique and specimen mammography. Surg J R Coll Surg Edinb Irel 2004; 2(6): 343–345. Surg J R Coll Surg Edinb Irel 4(1):60
13.
Metadata
Title
Comparison of intra-operative specimen mammography to standard specimen mammography for excision of non-palpable breast lesions: a randomized trial
Authors
Cynthia L. Miller
Suzanne B. Coopey
Elizabeth Rafferty
Michele Gadd
Barbara L. Smith
Michelle C. Specht
Publication date
01-02-2016
Publisher
Springer US
Published in
Breast Cancer Research and Treatment / Issue 3/2016
Print ISSN: 0167-6806
Electronic ISSN: 1573-7217
DOI
https://doi.org/10.1007/s10549-016-3700-8

Other articles of this Issue 3/2016

Breast Cancer Research and Treatment 3/2016 Go to the issue
Webinar | 19-02-2024 | 17:30 (CET)

Keynote webinar | Spotlight on antibody–drug conjugates in cancer

Antibody–drug conjugates (ADCs) are novel agents that have shown promise across multiple tumor types. Explore the current landscape of ADCs in breast and lung cancer with our experts, and gain insights into the mechanism of action, key clinical trials data, existing challenges, and future directions.

Dr. Véronique Diéras
Prof. Fabrice Barlesi
Developed by: Springer Medicine