Skip to main content
Top
Published in: Cardiovascular Ultrasound 1/2009

Open Access 01-12-2009 | Technical notes

Comparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function

Authors: Bernard Cosyns, David Haberman, Steven Droogmans, Sandrine Warzée, Philippe Mahieu, Eric Laurent, Marie Moonen, Sophie Hernot, Patrizio Lancellotti

Published in: Cardiovascular Ultrasound | Issue 1/2009

Login to get access

Abstract

Background

In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations.

Methods

Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated.

Results

Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 ± 65 mL and was underestimated by triplane contrast RT3DE (128 ± 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 ± 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 ± 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 ± 15%) and full-volume contrast RT3DE (45 ± 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques.

Conclusion

Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease.
Appendix
Available only for authorised users
Literature
1.
go back to reference White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ: Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation. 1987, 76 (1): 44-51.CrossRefPubMed White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ: Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation. 1987, 76 (1): 44-51.CrossRefPubMed
2.
go back to reference Wong M, Johnson G, Shabetai R, Hughes V, Bhat G, Lopez B, Cohn JN: Echocardiographic variables as prognostic indicators and therapeutic monitors in chronic congestive heart failure. Veterans Affairs cooperative studies V-HeFT I and II. V-HeFT VA Cooperative Studies Group. Circulation. 1993, 87 (6 Suppl): VI65-70.PubMed Wong M, Johnson G, Shabetai R, Hughes V, Bhat G, Lopez B, Cohn JN: Echocardiographic variables as prognostic indicators and therapeutic monitors in chronic congestive heart failure. Veterans Affairs cooperative studies V-HeFT I and II. V-HeFT VA Cooperative Studies Group. Circulation. 1993, 87 (6 Suppl): VI65-70.PubMed
3.
go back to reference Folland ED, Parisi AF, Moynihan PF, Jones DR, Feldman CL, Tow DE: Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation. 1979, 60 (4): 760-766.CrossRefPubMed Folland ED, Parisi AF, Moynihan PF, Jones DR, Feldman CL, Tow DE: Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation. 1979, 60 (4): 760-766.CrossRefPubMed
4.
go back to reference Teichholz LE, Kreulen T, Herman MV, Gorlin R: Problems in echocardiographic volume determinations: echocardiographic-angiographic correlations in the presence of absence of asynergy. Am J Cardiol. 1976, 37 (1): 7-11. 10.1016/0002-9149(76)90491-4.CrossRefPubMed Teichholz LE, Kreulen T, Herman MV, Gorlin R: Problems in echocardiographic volume determinations: echocardiographic-angiographic correlations in the presence of absence of asynergy. Am J Cardiol. 1976, 37 (1): 7-11. 10.1016/0002-9149(76)90491-4.CrossRefPubMed
5.
go back to reference Wyatt HL, Meerbaum S, Heng MK, Gueret P, Corday E: Cross-sectional echocardiography. III. Analysis of mathematic models for quantifying volume of symmetric and asymmetric left ventricles. Am Heart J. 1980, 100 (6 Pt 1): 821-828. 10.1016/0002-8703(80)90062-9.CrossRefPubMed Wyatt HL, Meerbaum S, Heng MK, Gueret P, Corday E: Cross-sectional echocardiography. III. Analysis of mathematic models for quantifying volume of symmetric and asymmetric left ventricles. Am Heart J. 1980, 100 (6 Pt 1): 821-828. 10.1016/0002-8703(80)90062-9.CrossRefPubMed
6.
go back to reference Sciagrà R, Bolognese L, Rovai D, Sestini S, Santoro GM, Cerisano G, Marini C, Buonamici P, Antoniucci D, Fazzini PF: Clinical Investigations – Detecting Myocardial Salvage After Primary PTCA: Early Myocardial Contrast Echocardiography Versus Delayed Sestamibi Perfusion Imaging. Journal of Nuclear Medicine. 1999, 40 (3): 363-370.PubMed Sciagrà R, Bolognese L, Rovai D, Sestini S, Santoro GM, Cerisano G, Marini C, Buonamici P, Antoniucci D, Fazzini PF: Clinical Investigations – Detecting Myocardial Salvage After Primary PTCA: Early Myocardial Contrast Echocardiography Versus Delayed Sestamibi Perfusion Imaging. Journal of Nuclear Medicine. 1999, 40 (3): 363-370.PubMed
7.
go back to reference Go V, Bhatt MR, Hendel RC: The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging. J Nucl Med. 2004, 45 (5): 912-921.PubMed Go V, Bhatt MR, Hendel RC: The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging. J Nucl Med. 2004, 45 (5): 912-921.PubMed
8.
go back to reference Yu EH, Sloggett CE, Iwanochko RM, Rakowski H, Siu SC: Feasibility and accuracy of left ventricular volumes and ejection fraction determination by fundamental, tissue harmonic, and intravenous contrast imaging in difficult-to-image patients. J Am Soc Echocardiogr. 2000, 13 (3): 216-224.CrossRefPubMed Yu EH, Sloggett CE, Iwanochko RM, Rakowski H, Siu SC: Feasibility and accuracy of left ventricular volumes and ejection fraction determination by fundamental, tissue harmonic, and intravenous contrast imaging in difficult-to-image patients. J Am Soc Echocardiogr. 2000, 13 (3): 216-224.CrossRefPubMed
9.
go back to reference Jenkins C, Bricknell K, Hanekom L, Marwick TH: Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol. 2004, 44 (4): 878-886. 10.1016/j.jacc.2004.05.050.CrossRefPubMed Jenkins C, Bricknell K, Hanekom L, Marwick TH: Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol. 2004, 44 (4): 878-886. 10.1016/j.jacc.2004.05.050.CrossRefPubMed
10.
go back to reference Senior R, Andersson O, Caidahl K, Carlens P, Herregods MC, Jenni R, Kenny A, Melcher A, Svedenhag J, Vanoverschelde JL, et al: Enhanced left ventricular endocardial border delineation with an intravenous injection of SonoVue, a new echocardiographic contrast agent: A European multicenter study. Echocardiography. 2000, 17 (8): 705-711. 10.1111/j.1540-8175.2000.tb01223.x.CrossRefPubMed Senior R, Andersson O, Caidahl K, Carlens P, Herregods MC, Jenni R, Kenny A, Melcher A, Svedenhag J, Vanoverschelde JL, et al: Enhanced left ventricular endocardial border delineation with an intravenous injection of SonoVue, a new echocardiographic contrast agent: A European multicenter study. Echocardiography. 2000, 17 (8): 705-711. 10.1111/j.1540-8175.2000.tb01223.x.CrossRefPubMed
11.
go back to reference Malm S, Frigstad S, Sagberg E, Larsson H, Skjaerpe T: Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging. J Am Coll Cardiol. 2004, 44 (5): 1030-1035. 10.1016/j.jacc.2004.05.068.CrossRefPubMed Malm S, Frigstad S, Sagberg E, Larsson H, Skjaerpe T: Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging. J Am Coll Cardiol. 2004, 44 (5): 1030-1035. 10.1016/j.jacc.2004.05.068.CrossRefPubMed
12.
go back to reference Jenkins C, Bricknell K, Chan J, Hanekom L, Marwick TH: Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction. Am J Cardiol. 2007, 99 (3): 300-306. 10.1016/j.amjcard.2006.08.026.CrossRefPubMed Jenkins C, Bricknell K, Chan J, Hanekom L, Marwick TH: Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction. Am J Cardiol. 2007, 99 (3): 300-306. 10.1016/j.amjcard.2006.08.026.CrossRefPubMed
13.
go back to reference Sugeng L, Mor-Avi V, Weinert L, Niel J, Ebner C, Steringer-Mascherbauer R, Schmidt F, Galuschky C, Schummers G, Lang RM, et al: Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation. 2006, 114 (7): 654-661. 10.1161/CIRCULATIONAHA.106.626143.CrossRefPubMed Sugeng L, Mor-Avi V, Weinert L, Niel J, Ebner C, Steringer-Mascherbauer R, Schmidt F, Galuschky C, Schummers G, Lang RM, et al: Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference. Circulation. 2006, 114 (7): 654-661. 10.1161/CIRCULATIONAHA.106.626143.CrossRefPubMed
14.
go back to reference Jenkins C, Leano R, Chan J, Marwick TH: Reconstructed versus real-time 3-dimensional echocardiography: comparison with magnetic resonance imaging. J Am Soc Echocardiogr. 2007, 20 (7): 862-868. 10.1016/j.echo.2006.12.010.CrossRefPubMed Jenkins C, Leano R, Chan J, Marwick TH: Reconstructed versus real-time 3-dimensional echocardiography: comparison with magnetic resonance imaging. J Am Soc Echocardiogr. 2007, 20 (7): 862-868. 10.1016/j.echo.2006.12.010.CrossRefPubMed
15.
go back to reference Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, Van Train KF, Berman DS: Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med. 1995, 36 (11): 2138-2147.PubMed Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, Van Train KF, Berman DS: Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med. 1995, 36 (11): 2138-2147.PubMed
16.
go back to reference Everaert H, Bossuyt A, Franken PR: Left ventricular ejection fraction and volumes from gated single photon emission tomographic myocardial perfusion images: comparison between two algorithms working in three-dimensional space. J Nucl Cardiol. 1997, 4 (6): 472-476. 10.1016/S1071-3581(97)90004-0.CrossRefPubMed Everaert H, Bossuyt A, Franken PR: Left ventricular ejection fraction and volumes from gated single photon emission tomographic myocardial perfusion images: comparison between two algorithms working in three-dimensional space. J Nucl Cardiol. 1997, 4 (6): 472-476. 10.1016/S1071-3581(97)90004-0.CrossRefPubMed
17.
go back to reference Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1 (8476): 307-310.CrossRefPubMed Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1 (8476): 307-310.CrossRefPubMed
18.
go back to reference Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, Gutgesell H, Reichek N, Sahn D, Schnittger I, et al: Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr. 1989, 2 (5): 358-367.CrossRefPubMed Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, Gutgesell H, Reichek N, Sahn D, Schnittger I, et al: Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr. 1989, 2 (5): 358-367.CrossRefPubMed
19.
go back to reference Al-Mansour HA, Mulvagh SL, Pumper GM, Klarich KW, Foley DA: Usefulness of harmonic imaging for left ventricular opacification and endocardial border delineation by optison. Am J Cardiol. 2000, 85 (6): 795-799. 10.1016/S0002-9149(99)00868-1.CrossRefPubMed Al-Mansour HA, Mulvagh SL, Pumper GM, Klarich KW, Foley DA: Usefulness of harmonic imaging for left ventricular opacification and endocardial border delineation by optison. Am J Cardiol. 2000, 85 (6): 795-799. 10.1016/S0002-9149(99)00868-1.CrossRefPubMed
20.
go back to reference Corsi C, Lang RM, Veronesi F, Weinert L, Caiani EG, MacEneaney P, Lamberti C, Mor-Avi V: Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images. Circulation. 2005, 112 (8): 1161-1170. 10.1161/CIRCULATIONAHA.104.513689.CrossRefPubMed Corsi C, Lang RM, Veronesi F, Weinert L, Caiani EG, MacEneaney P, Lamberti C, Mor-Avi V: Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images. Circulation. 2005, 112 (8): 1161-1170. 10.1161/CIRCULATIONAHA.104.513689.CrossRefPubMed
21.
go back to reference Kuhl HP, Schreckenberg M, Rulands D, Katoh M, Schafer W, Schummers G, Bucker A, Hanrath P, Franke A: High-resolution transthoracic real-time three-dimensional echocardiography: quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging. J Am Coll Cardiol. 2004, 43 (11): 2083-2090. 10.1016/j.jacc.2004.01.037.CrossRefPubMed Kuhl HP, Schreckenberg M, Rulands D, Katoh M, Schafer W, Schummers G, Bucker A, Hanrath P, Franke A: High-resolution transthoracic real-time three-dimensional echocardiography: quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging. J Am Coll Cardiol. 2004, 43 (11): 2083-2090. 10.1016/j.jacc.2004.01.037.CrossRefPubMed
22.
go back to reference Jenkins C, Chan J, Hanekom L, Marwick TH: Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters. J Am Soc Echocardiogr. 2006, 19 (9): 1119-1128. 10.1016/j.echo.2006.04.002.CrossRefPubMed Jenkins C, Chan J, Hanekom L, Marwick TH: Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters. J Am Soc Echocardiogr. 2006, 19 (9): 1119-1128. 10.1016/j.echo.2006.04.002.CrossRefPubMed
23.
go back to reference Nikitin NP, Constantin C, Loh PH, Ghosh J, Lukaschuk EI, Bennett A, Hurren S, Alamgir F, Clark AL, Cleland JG: New generation 3-dimensional echocardiography for left ventricular volumetric and functional measurements: comparison with cardiac magnetic resonance. Eur J Echocardiogr. 2006, 7 (5): 365-372. 10.1016/j.euje.2005.09.005.CrossRefPubMed Nikitin NP, Constantin C, Loh PH, Ghosh J, Lukaschuk EI, Bennett A, Hurren S, Alamgir F, Clark AL, Cleland JG: New generation 3-dimensional echocardiography for left ventricular volumetric and functional measurements: comparison with cardiac magnetic resonance. Eur J Echocardiogr. 2006, 7 (5): 365-372. 10.1016/j.euje.2005.09.005.CrossRefPubMed
24.
go back to reference Qi X, Cogar B, Hsiung MC, Nanda NC, Miller AP, Yelamanchili P, Baysan O, Wu YS, Lan GY, Ko JS, et al: Live/real time three-dimensional transthoracic echocardiographic assessment of left ventricular volumes, ejection fraction, and mass compared with magnetic resonance imaging. Echocardiography. 2007, 24 (2): 166-173. 10.1111/j.1540-8175.2006.00428.x.CrossRefPubMed Qi X, Cogar B, Hsiung MC, Nanda NC, Miller AP, Yelamanchili P, Baysan O, Wu YS, Lan GY, Ko JS, et al: Live/real time three-dimensional transthoracic echocardiographic assessment of left ventricular volumes, ejection fraction, and mass compared with magnetic resonance imaging. Echocardiography. 2007, 24 (2): 166-173. 10.1111/j.1540-8175.2006.00428.x.CrossRefPubMed
25.
go back to reference Lee D, Fuisz AR, Fan PH, Hsu TL, Liu CP, Chiang HT: Real-time 3-dimensional echocardiographic evaluation of left ventricular volume: correlation with magnetic resonance imaging – a validation study. J Am Soc Echocardiogr. 2001, 14 (10): 1001-1009. 10.1067/mje.2001.113647.CrossRefPubMed Lee D, Fuisz AR, Fan PH, Hsu TL, Liu CP, Chiang HT: Real-time 3-dimensional echocardiographic evaluation of left ventricular volume: correlation with magnetic resonance imaging – a validation study. J Am Soc Echocardiogr. 2001, 14 (10): 1001-1009. 10.1067/mje.2001.113647.CrossRefPubMed
26.
go back to reference Tighe DA, Rosetti M, Vinch CS, Chandok D, Muldoon D, Wiggin B, Dahlberg ST, Aurigemma GP: Influence of image quality on the accuracy of real time three-dimensional echocardiography to measure left ventricular volumes in unselected patients: a comparison with gated-SPECT imaging. Echocardiography. 2007, 24 (10): 1073-1080. 10.1111/j.1540-8175.2007.00525.x.CrossRefPubMed Tighe DA, Rosetti M, Vinch CS, Chandok D, Muldoon D, Wiggin B, Dahlberg ST, Aurigemma GP: Influence of image quality on the accuracy of real time three-dimensional echocardiography to measure left ventricular volumes in unselected patients: a comparison with gated-SPECT imaging. Echocardiography. 2007, 24 (10): 1073-1080. 10.1111/j.1540-8175.2007.00525.x.CrossRefPubMed
27.
go back to reference Chuang ML, Parker RA, Riley MF, Reilly MA, Johnson RB, Korley VJ, Lerner AB, Douglas PS: Three-dimensional echocardiography improves accuracy and compensates for sonographer inexperience in assessment of left ventricular ejection fraction. J Am Soc Echocardiogr. 1999, 12 (5): 290-299. 10.1016/S0894-7317(99)70049-0.CrossRefPubMed Chuang ML, Parker RA, Riley MF, Reilly MA, Johnson RB, Korley VJ, Lerner AB, Douglas PS: Three-dimensional echocardiography improves accuracy and compensates for sonographer inexperience in assessment of left ventricular ejection fraction. J Am Soc Echocardiogr. 1999, 12 (5): 290-299. 10.1016/S0894-7317(99)70049-0.CrossRefPubMed
28.
go back to reference Jacobs LD, Salgo IS, Goonewardena S, Weinert L, Coon P, Bardo D, Gerard O, Allain P, Zamorano JL, de Isla LP, et al: Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data. Eur Heart J. 2006, 27 (4): 460-468. 10.1093/eurheartj/ehi666.CrossRefPubMed Jacobs LD, Salgo IS, Goonewardena S, Weinert L, Coon P, Bardo D, Gerard O, Allain P, Zamorano JL, de Isla LP, et al: Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data. Eur Heart J. 2006, 27 (4): 460-468. 10.1093/eurheartj/ehi666.CrossRefPubMed
29.
go back to reference Krenning BJ, Kirschbaum SW, Soliman OI, Nemes A, van Geuns RJ, Vletter WB, Veltman CE, Ten Cate FJ, Roelandt JR, Geleijnse ML: Comparison of contrast agent-enhanced versus non-contrast agent-enhanced real-time three-dimensional echocardiography for analysis of left ventricular systolic function. Am J Cardiol. 2007, 100 (9): 1485-1489. 10.1016/j.amjcard.2007.06.042.CrossRefPubMed Krenning BJ, Kirschbaum SW, Soliman OI, Nemes A, van Geuns RJ, Vletter WB, Veltman CE, Ten Cate FJ, Roelandt JR, Geleijnse ML: Comparison of contrast agent-enhanced versus non-contrast agent-enhanced real-time three-dimensional echocardiography for analysis of left ventricular systolic function. Am J Cardiol. 2007, 100 (9): 1485-1489. 10.1016/j.amjcard.2007.06.042.CrossRefPubMed
30.
go back to reference Gutierrez-Chico JL, Zamorano JL, Perez de Isla L, Orejas M, Almeria C, Rodrigo JL, Ferreiros J, Serra V, Macaya C: Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies. Am J Cardiol. 2005, 95 (6): 809-813. 10.1016/j.amjcard.2004.11.046.CrossRefPubMed Gutierrez-Chico JL, Zamorano JL, Perez de Isla L, Orejas M, Almeria C, Rodrigo JL, Ferreiros J, Serra V, Macaya C: Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies. Am J Cardiol. 2005, 95 (6): 809-813. 10.1016/j.amjcard.2004.11.046.CrossRefPubMed
31.
go back to reference Bax JJ, Lamb H, Dibbets P, Pelikan H, Boersma E, Viergever EP, Germano G, Vliegen HW, de Roos A, Pauwels EK, et al: Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy. Am J Cardiol. 2000, 86 (12): 1299-1305. 10.1016/S0002-9149(00)01231-5.CrossRefPubMed Bax JJ, Lamb H, Dibbets P, Pelikan H, Boersma E, Viergever EP, Germano G, Vliegen HW, de Roos A, Pauwels EK, et al: Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy. Am J Cardiol. 2000, 86 (12): 1299-1305. 10.1016/S0002-9149(00)01231-5.CrossRefPubMed
32.
go back to reference Tadamura E, Kudoh T, Motooka M, Inubushi M, Shirakawa S, Hattori N, Okada T, Matsuda T, Koshiji T, Nishimura K, et al: Assessment of regional and global left ventricular function by reinjection T1-201 and rest Tc-99m sestamibi ECG-gated SPECT: comparison with three-dimensional magnetic resonance imaging. J Am Coll Cardiol. 1999, 33 (4): 991-997. 10.1016/S0735-1097(98)00661-5.CrossRefPubMed Tadamura E, Kudoh T, Motooka M, Inubushi M, Shirakawa S, Hattori N, Okada T, Matsuda T, Koshiji T, Nishimura K, et al: Assessment of regional and global left ventricular function by reinjection T1-201 and rest Tc-99m sestamibi ECG-gated SPECT: comparison with three-dimensional magnetic resonance imaging. J Am Coll Cardiol. 1999, 33 (4): 991-997. 10.1016/S0735-1097(98)00661-5.CrossRefPubMed
33.
go back to reference Vaduganathan P, He ZX, Mahmarian JJ, Verani MS: Diagnostic accuracy of stress thallium-201 tomography in patients with left ventricular hypertrophy. Am J Cardiol. 1998, 81 (10): 1205-1207. 10.1016/S0002-9149(98)00091-5.CrossRefPubMed Vaduganathan P, He ZX, Mahmarian JJ, Verani MS: Diagnostic accuracy of stress thallium-201 tomography in patients with left ventricular hypertrophy. Am J Cardiol. 1998, 81 (10): 1205-1207. 10.1016/S0002-9149(98)00091-5.CrossRefPubMed
34.
go back to reference Heide van der JA, Mannaerts HF, Yang L, Sieswerda GT, Visser CA, Kamp O: Contrast-enhanced versus non-enhanced three-dimensional echocardiography of left ventricular volumes. Neth Heart J. 2008, 16 (2): 47-52.CrossRefPubMedPubMedCentral Heide van der JA, Mannaerts HF, Yang L, Sieswerda GT, Visser CA, Kamp O: Contrast-enhanced versus non-enhanced three-dimensional echocardiography of left ventricular volumes. Neth Heart J. 2008, 16 (2): 47-52.CrossRefPubMedPubMedCentral
35.
go back to reference Caiani EG, Corsi C, Zamorano J, Sugeng L, MacEneaney P, Weinert L, Battani R, Gutierrez JL, Koch R, Perez de Isla L, et al: Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging. J Am Soc Echocardiogr. 2005, 18 (8): 779-788. 10.1016/j.echo.2004.12.015.CrossRefPubMed Caiani EG, Corsi C, Zamorano J, Sugeng L, MacEneaney P, Weinert L, Battani R, Gutierrez JL, Koch R, Perez de Isla L, et al: Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging. J Am Soc Echocardiogr. 2005, 18 (8): 779-788. 10.1016/j.echo.2004.12.015.CrossRefPubMed
36.
go back to reference Jenkins C, Moir S, Chan J, Rakhit D, Haluska B, Marwick TH: Left ventricular volume measurement with echocardiography: a comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging. Eur Heart J. 2009, 30 (1): 98-106. 10.1093/eurheartj/ehn484.CrossRefPubMed Jenkins C, Moir S, Chan J, Rakhit D, Haluska B, Marwick TH: Left ventricular volume measurement with echocardiography: a comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging. Eur Heart J. 2009, 30 (1): 98-106. 10.1093/eurheartj/ehn484.CrossRefPubMed
Metadata
Title
Comparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function
Authors
Bernard Cosyns
David Haberman
Steven Droogmans
Sandrine Warzée
Philippe Mahieu
Eric Laurent
Marie Moonen
Sophie Hernot
Patrizio Lancellotti
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Cardiovascular Ultrasound / Issue 1/2009
Electronic ISSN: 1476-7120
DOI
https://doi.org/10.1186/1476-7120-7-27

Other articles of this Issue 1/2009

Cardiovascular Ultrasound 1/2009 Go to the issue
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discuss last year's major advances in heart failure and cardiomyopathies.