Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 6/2013

01-08-2013 | Original Paper

Comparison of aortic root dimension changes during cardiac cycle between the patients with and without aortic valve calcification using ECG-gated 64-slice and dual-source 256-slice computed tomography scanners: results of a multicenter study

Authors: Abbas Arjmand Shabestari, Ramin Pourghorban, Mahmood Tehrai, Hamidreza Pouraliakbar, Taraneh Faghihi Langroudi, Hooman Bakhshandeh, Seifollah Abdi

Published in: The International Journal of Cardiovascular Imaging | Issue 6/2013

Login to get access

Abstract

With advent of transcatheter aortic valve implantation, using multislice computed tomography (MSCT) to provide detailed data about aortic root has become more crucial. We compared aortic dimension changes during cardiac cycle in patients with and without aortic valve calcification and evaluated its correlation with aortic valve calcium score in former group. Fifty-two patients with and 52 subjects without aortic valve calcification underwent coronary MSCT using two 64-slice and a dual-source 256-slice CT scanners. Aortic root dimensions were measured in both systolic and diastolic phases. Changes in annular maximum diameter (Dmax), minimum diameter (Dmin), cross sectional area and perimeter, three diameters of sinuses of Valsalva (Va, Vb and Vc), sinotubular junction maximum (STJmax) and minimum (STJmin) diameters between systolic and diastolic phases (systole minus diastole) were −0.59 mm, −0.05 mm, −2.53 mm2, −1.48 mm, +0.91 mm, +1.08 mm, +0.42 mm, +0.63 mm, +0.40 mm and in those without aortic calcification –0.33 mm, 0.00 mm, −6.92 mm2, −0.41 mm, +0.30 mm, +0.38 mm, +0.61 mm, +0.33 mm, +0.20 mm in patients with aortic calcification, respectively. Apart from two diameters in sinuses of Valsalva (Va and Vb), changes in all other diameters of aortic root during cardiac cycle were not significantly different between the two groups. Furthermore, in patients with aortic calcification, no significant correlation was detected between changes in nearly all aortic root dimensions during cardiac cycle and aortic valve calcium score or location of calcification (annular, commissural or both).
Literature
1.
go back to reference Tops LF, Wood DA, Delgado V, Schuijf JD, Mayo JR, Pasupati S, Lamers FP, van der Wall EE, Schalij MJ, Webb JG, Bax JJ (2008) Noninvasive evaluation of the aortic root with multislice computed tomography. Implication for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1:321–330PubMedCrossRef Tops LF, Wood DA, Delgado V, Schuijf JD, Mayo JR, Pasupati S, Lamers FP, van der Wall EE, Schalij MJ, Webb JG, Bax JJ (2008) Noninvasive evaluation of the aortic root with multislice computed tomography. Implication for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1:321–330PubMedCrossRef
2.
go back to reference Leipsic J, Gurvitch R, Labounty TM, Min JK, Wood D, Johnson M, Ajlan AM, Wijesinghe N, Webb JG (2011) Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 4:416–429PubMedCrossRef Leipsic J, Gurvitch R, Labounty TM, Min JK, Wood D, Johnson M, Ajlan AM, Wijesinghe N, Webb JG (2011) Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 4:416–429PubMedCrossRef
3.
go back to reference Wood DA, Tops LF, Mayo JR, Pasupati S, Schalij MJ, Humphries K, Lee M, Al Ali A, Munt B, Moss R, Thompson CR, Bax JJ, Webb JG (2009) Role of multislice computed tomography in transcatheter aortic valve replacement. Am J Cardiol 103(9):1295–1301PubMedCrossRef Wood DA, Tops LF, Mayo JR, Pasupati S, Schalij MJ, Humphries K, Lee M, Al Ali A, Munt B, Moss R, Thompson CR, Bax JJ, Webb JG (2009) Role of multislice computed tomography in transcatheter aortic valve replacement. Am J Cardiol 103(9):1295–1301PubMedCrossRef
4.
go back to reference Willson AB, Webb JG, Freeman M, Wood DA, Gurvitch R, Thompson CR, Moss RR, Toggweiler S, Binder RK, Munt B, Cheung A, Hague C, Ye J, Leipsic JA (2012) Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: comparison with transesophageal echocardiography and rationale for implementation in a prospective trial. J Cardiovasc Comput Tomogr 6(6):406–414PubMedCrossRef Willson AB, Webb JG, Freeman M, Wood DA, Gurvitch R, Thompson CR, Moss RR, Toggweiler S, Binder RK, Munt B, Cheung A, Hague C, Ye J, Leipsic JA (2012) Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: comparison with transesophageal echocardiography and rationale for implementation in a prospective trial. J Cardiovasc Comput Tomogr 6(6):406–414PubMedCrossRef
5.
go back to reference Mizia-Stec K, Pysz P, Jasiński M, Adamczyk T, Drzewiecka-Gerber A, Chmiel A, Krejca M, Bochenek A, Woś S, Sosnowski M, Gąsior Z, Trusz-Gluza M, Tendera M (2012) Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis. Int J Cardiovasc Imaging 28:343–352PubMedCrossRef Mizia-Stec K, Pysz P, Jasiński M, Adamczyk T, Drzewiecka-Gerber A, Chmiel A, Krejca M, Bochenek A, Woś S, Sosnowski M, Gąsior Z, Trusz-Gluza M, Tendera M (2012) Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis. Int J Cardiovasc Imaging 28:343–352PubMedCrossRef
6.
go back to reference Ewe SH, Klautz RJ, Schalij MJ, Delgado V (2011) Role of computed tomography imaging for transcatheter valvular repair/insertion. Int J Cardiovasc Imaging 27:1179–1193PubMedCrossRef Ewe SH, Klautz RJ, Schalij MJ, Delgado V (2011) Role of computed tomography imaging for transcatheter valvular repair/insertion. Int J Cardiovasc Imaging 27:1179–1193PubMedCrossRef
7.
go back to reference Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA (2012) SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 6(6):366–380PubMedCrossRef Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA (2012) SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 6(6):366–380PubMedCrossRef
8.
go back to reference Blanke P, Euringer W, Baumann T, Reinöhl J, Schlensak C, Langer M, Pache G (2010) Combined assessment of aortic root anatomy and aortoiliac vasculature with dual-source CT as a screening tool in patients evaluated for transcatheter aortic valve implantation. AJR Am J Roentgenol 195:872–881PubMedCrossRef Blanke P, Euringer W, Baumann T, Reinöhl J, Schlensak C, Langer M, Pache G (2010) Combined assessment of aortic root anatomy and aortoiliac vasculature with dual-source CT as a screening tool in patients evaluated for transcatheter aortic valve implantation. AJR Am J Roentgenol 195:872–881PubMedCrossRef
9.
go back to reference Leipsic J, Wood D, Manders D, Nietlispach F, Masson JB, Mayo J, Al-Bugami S, Webb JG (2009) The evolving role of MDCT in transcatheter aortic valve replacement: a radiologists’ perspective. AJR Am J Roentgenol 193:W214–W219PubMedCrossRef Leipsic J, Wood D, Manders D, Nietlispach F, Masson JB, Mayo J, Al-Bugami S, Webb JG (2009) The evolving role of MDCT in transcatheter aortic valve replacement: a radiologists’ perspective. AJR Am J Roentgenol 193:W214–W219PubMedCrossRef
10.
go back to reference Thubrikar MK, Harry R, Nolan SP (1977) Normal aortic valve function in dogs. Am J Cardiol 40:563–568PubMedCrossRef Thubrikar MK, Harry R, Nolan SP (1977) Normal aortic valve function in dogs. Am J Cardiol 40:563–568PubMedCrossRef
11.
go back to reference Gnyaneshwar R, Kumar RK, Balakrishnan KR (2002) Dynamic analysis of the aortic valve using finite element model. Ann Thorac Surg 73:1122–1129PubMedCrossRef Gnyaneshwar R, Kumar RK, Balakrishnan KR (2002) Dynamic analysis of the aortic valve using finite element model. Ann Thorac Surg 73:1122–1129PubMedCrossRef
12.
go back to reference de Heer LM, Budde RP, Mali WP, de Vos AM, van Herwerden LA, Kluin J (2011) Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography. Int J Cardiovasc Imaging 27:1195–1204PubMedCrossRef de Heer LM, Budde RP, Mali WP, de Vos AM, van Herwerden LA, Kluin J (2011) Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography. Int J Cardiovasc Imaging 27:1195–1204PubMedCrossRef
13.
go back to reference de Heer LM, Budde RP, van Prehn J, Mali WP, Bartels LW, Stella PR, van Herwerden LA, Kluin J, Vincken KL (2012) Pulsatile distention of the nondiseased and stenotic aortic valve annulus: analysis with electrocardiogram-gated computed tomography. Ann Thorac Surg 93:516–522PubMedCrossRef de Heer LM, Budde RP, van Prehn J, Mali WP, Bartels LW, Stella PR, van Herwerden LA, Kluin J, Vincken KL (2012) Pulsatile distention of the nondiseased and stenotic aortic valve annulus: analysis with electrocardiogram-gated computed tomography. Ann Thorac Surg 93:516–522PubMedCrossRef
14.
go back to reference Bertaso AG, Wong DT, Liew GY, Cunnington MS, Richardson JD, Thomson VS, Lorraine B, Kourlis G, Leech D, Worthley MI, Worthley SG (2012) Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole. Int J Cardiovasc Imaging 28(8):2091–2098PubMedCrossRef Bertaso AG, Wong DT, Liew GY, Cunnington MS, Richardson JD, Thomson VS, Lorraine B, Kourlis G, Leech D, Worthley MI, Worthley SG (2012) Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole. Int J Cardiovasc Imaging 28(8):2091–2098PubMedCrossRef
15.
go back to reference Kingwell BA, Waddell TK, Medley TL, Cameron JD, Dart AM (2002) Large artery stiffness predicts ischemic threshold in patients with coronary artery disease. J Am Coll Cardiol 40(4):773–779PubMedCrossRef Kingwell BA, Waddell TK, Medley TL, Cameron JD, Dart AM (2002) Large artery stiffness predicts ischemic threshold in patients with coronary artery disease. J Am Coll Cardiol 40(4):773–779PubMedCrossRef
16.
go back to reference Cruickshank K, Riste L, Anderson SG, Wright JS, Dunn G, Gosling RG (2002) Aortic pulse-wave velocity and its relationship to mortality in diabetes and glucose intolerance: an integrated index of vascular function? Circulation 106(16):2085–2090PubMedCrossRef Cruickshank K, Riste L, Anderson SG, Wright JS, Dunn G, Gosling RG (2002) Aortic pulse-wave velocity and its relationship to mortality in diabetes and glucose intolerance: an integrated index of vascular function? Circulation 106(16):2085–2090PubMedCrossRef
17.
go back to reference Tentolouris N, Liatis S, Moyssakis I, Tsapogas P, Psallas M, Diakoumopoulou E, Voteas V, Katsilambros N (2003) Aortic distensibility is reduced in subjects with type 2 diabetes and cardiac autonomic neuropathy. Eur J Clin Invest 33(12):1075–1083PubMedCrossRef Tentolouris N, Liatis S, Moyssakis I, Tsapogas P, Psallas M, Diakoumopoulou E, Voteas V, Katsilambros N (2003) Aortic distensibility is reduced in subjects with type 2 diabetes and cardiac autonomic neuropathy. Eur J Clin Invest 33(12):1075–1083PubMedCrossRef
18.
go back to reference Schultz CJ, Moelker A, Piazza N, Tzikas A, Otten A, Nuis RJ, Neefjes LA, van Geuns RJ, de Feyter P, Krestin G, Serruys PW, de Jaegere PP (2010) Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer’s guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 31:849–856PubMedCrossRef Schultz CJ, Moelker A, Piazza N, Tzikas A, Otten A, Nuis RJ, Neefjes LA, van Geuns RJ, de Feyter P, Krestin G, Serruys PW, de Jaegere PP (2010) Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer’s guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 31:849–856PubMedCrossRef
20.
go back to reference Ng AC, Delgado V, van der Kley F, Shanks M, van de Veire NR, Bertini M, Nucifora G, van Bommel RJ, Tops LF, de Weger A, Tavilla G, de Roos A, Kroft LJ, Leung DY, Schuijf J, Schalij MJ, Bax JJ (2010) Comparison of aortic root dimensions and geometries pre- and post-transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multi-slice computed tomography. Circ Cardiovasc Imaging 3:94–102PubMedCrossRef Ng AC, Delgado V, van der Kley F, Shanks M, van de Veire NR, Bertini M, Nucifora G, van Bommel RJ, Tops LF, de Weger A, Tavilla G, de Roos A, Kroft LJ, Leung DY, Schuijf J, Schalij MJ, Bax JJ (2010) Comparison of aortic root dimensions and geometries pre- and post-transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multi-slice computed tomography. Circ Cardiovasc Imaging 3:94–102PubMedCrossRef
21.
go back to reference Rixe J, Schuhbaeck A, Liebetrau C, Moellmann H, Nef HM, Szardien S, Brandt R, Schmitt J, Neumann T, Schneider C, Krombach G, Hamm CW, Achenbach S, Rolf A (2012) Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation. Eur Radiol 22:2662–2669PubMedCrossRef Rixe J, Schuhbaeck A, Liebetrau C, Moellmann H, Nef HM, Szardien S, Brandt R, Schmitt J, Neumann T, Schneider C, Krombach G, Hamm CW, Achenbach S, Rolf A (2012) Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation. Eur Radiol 22:2662–2669PubMedCrossRef
22.
go back to reference Delgado V, Ng AC, van de Veire NR, van der Kley F, Schuijf JD, Tops LF, de Weger A, Tavilla G, de Roos A, Kroft LJ, Schalij MJ, Bax JJ (2010) Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function. Eur Heart J 31:1114–1123PubMedCrossRef Delgado V, Ng AC, van de Veire NR, van der Kley F, Schuijf JD, Tops LF, de Weger A, Tavilla G, de Roos A, Kroft LJ, Schalij MJ, Bax JJ (2010) Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function. Eur Heart J 31:1114–1123PubMedCrossRef
23.
go back to reference Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, Makhija R, Doctor N, Leon MB, Makkar RR (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59(14):1275–1286PubMedCrossRef Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, Makhija R, Doctor N, Leon MB, Makkar RR (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59(14):1275–1286PubMedCrossRef
24.
go back to reference Messika-Zeitoun D, Serfaty JM, Brochet E, Ducrocq G, Lepage L, Detaint D, Hyafil F, Himbert D, Pasi N, Laissy JP, Iung B, Vahanian A (2010) Multimodal assessment of the aortic annulus diameter. J Am Coll Cardiol 55:186–194PubMedCrossRef Messika-Zeitoun D, Serfaty JM, Brochet E, Ducrocq G, Lepage L, Detaint D, Hyafil F, Himbert D, Pasi N, Laissy JP, Iung B, Vahanian A (2010) Multimodal assessment of the aortic annulus diameter. J Am Coll Cardiol 55:186–194PubMedCrossRef
25.
go back to reference Kazui T, Izumoto H, Yoshioka K, Kawazoe K (2006) Dynamic morphologic changes in the normal aortic annulus during systole and diastole. J Heart Valve Dis 15(5):617–621PubMed Kazui T, Izumoto H, Yoshioka K, Kawazoe K (2006) Dynamic morphologic changes in the normal aortic annulus during systole and diastole. J Heart Valve Dis 15(5):617–621PubMed
26.
go back to reference Ahmadi N, Nabavi V, Hajsadeghi F, Flores F, Azmoon S, Ismaeel H, Shavelle D, Mao SS, Ebrahimi R, Budoff MJ (2011) Impaired aortic distensibility measured by computed tomography is associated with the severity of coronary artery disease. Int J Cardiovasc Imaging 27:459–469PubMedCrossRef Ahmadi N, Nabavi V, Hajsadeghi F, Flores F, Azmoon S, Ismaeel H, Shavelle D, Mao SS, Ebrahimi R, Budoff MJ (2011) Impaired aortic distensibility measured by computed tomography is associated with the severity of coronary artery disease. Int J Cardiovasc Imaging 27:459–469PubMedCrossRef
27.
go back to reference Lehmkuhl L, Foldyna B, Von Aspern K, Lücke C, Grothoff M, Nitzsche S, Kempfert J, Haensig M, Rastan A, Walther T, Mohr FW, Gutberlet M (2012) Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it crucial for correct sizing? Int J Cardiovasc Imaging 29(3):693–703PubMedCrossRef Lehmkuhl L, Foldyna B, Von Aspern K, Lücke C, Grothoff M, Nitzsche S, Kempfert J, Haensig M, Rastan A, Walther T, Mohr FW, Gutberlet M (2012) Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it crucial for correct sizing? Int J Cardiovasc Imaging 29(3):693–703PubMedCrossRef
28.
go back to reference Cueff C, Serfaty JM, Cimadevilla C, Laissy JP, Himbert D, Tubach F, Duval X, Iung B, Enriquez-Sarano M, Vahanian A, Messika-Zeitoun D (2011) Measurement of aortic valve calcification using multislice computed tomography: correlation with haemodynamic severity of aortic stenosis and clinical implication for patients with low ejection fraction. Heart 97(9):721–726PubMedCrossRef Cueff C, Serfaty JM, Cimadevilla C, Laissy JP, Himbert D, Tubach F, Duval X, Iung B, Enriquez-Sarano M, Vahanian A, Messika-Zeitoun D (2011) Measurement of aortic valve calcification using multislice computed tomography: correlation with haemodynamic severity of aortic stenosis and clinical implication for patients with low ejection fraction. Heart 97(9):721–726PubMedCrossRef
29.
go back to reference Gokce N, Holbrook M, Hunter LM, Palmisano J, Vigalok E, Keaney JF Jr, Vita JA (2002) Acute effects of vasoactive drug treatment on brachial artery reactivity. J Am Coll Cardiol 40(4):761–765PubMedCrossRef Gokce N, Holbrook M, Hunter LM, Palmisano J, Vigalok E, Keaney JF Jr, Vita JA (2002) Acute effects of vasoactive drug treatment on brachial artery reactivity. J Am Coll Cardiol 40(4):761–765PubMedCrossRef
Metadata
Title
Comparison of aortic root dimension changes during cardiac cycle between the patients with and without aortic valve calcification using ECG-gated 64-slice and dual-source 256-slice computed tomography scanners: results of a multicenter study
Authors
Abbas Arjmand Shabestari
Ramin Pourghorban
Mahmood Tehrai
Hamidreza Pouraliakbar
Taraneh Faghihi Langroudi
Hooman Bakhshandeh
Seifollah Abdi
Publication date
01-08-2013
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 6/2013
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-013-0217-7

Other articles of this Issue 6/2013

The International Journal of Cardiovascular Imaging 6/2013 Go to the issue