Skip to main content
Top
Published in: European Archives of Paediatric Dentistry 1/2019

01-02-2019 | Original Scientific Article

Comparative evaluation of surface roughness of posterior primary zirconia crowns

Authors: T. Walia, C. Brigi, Abdel Rahman M. M. KhirAllah

Published in: European Archives of Paediatric Dentistry | Issue 1/2019

Login to get access

Abstract

Aims

To compare the surface roughness of four commercially available posterior zirconia crowns on the occlusal surface and occlusal edge (buccal cusps) of first and second primary molars crowns.

Methods

Surface roughness of 40 posterior primary zirconia crowns was measured using a mechanical stylus profilometer. Ten mandibular right molar crowns, consisting of five first primary molar and five second primary molar crowns from four brands—Cheng, Sprig EZCrowns, NuSmile and Kinder Krowns were selected. Mean roughness, Ra and mean roughness depth, Rz was measured for all crowns on two selected surfaces, occlusal surface and buccal cusp tips. Data was evaluated by one way analysis of variance and Tukey’s honestly significant difference test at 0.05 level of significance.

Results

Statistically significant differences were observed in the mean Ra and Rz values at both selected surfaces among four prefabricated paedodontic zirconia crowns. Kinder Krowns had higher Ra and Rz values compared to Cheng, Sprig EZCrowns and NuSmile. Roughness profile of Kinder Krowns also showed higher vertical scale values co-relating with higher Ra and Rz scores, irrespective of the measurements taken on relatively flat surfaces (occlusal edge) or deeper surface (occlusal pits and fissures).

Conclusions

Mechanically polished posterior primary zirconia crowns had a smoother surface profile than the combined polished-glazed primary zirconia crowns. Cheng Crowns had the lowest mean Ra and Rz values although not statistically significant from Sprig EZCrowns and Nu Smile. Kinder Krowns had the highest mean Ra and Rz scores than other crown groups.
Literature
go back to reference Abdulhadi SB, Abdullah MM, Alaki SM, et al. Clinical evaluation between zirconia crowns and stainless steel crowns in primary molars teeth. J Pediatr Dent. 2017;5:21–7.CrossRef Abdulhadi SB, Abdullah MM, Alaki SM, et al. Clinical evaluation between zirconia crowns and stainless steel crowns in primary molars teeth. J Pediatr Dent. 2017;5:21–7.CrossRef
go back to reference Arecchi FT, Bertani D, Ciliberto S. A fast versatile optical profilometer. Opt Commun. 1979;31:263–6.CrossRef Arecchi FT, Bertani D, Ciliberto S. A fast versatile optical profilometer. Opt Commun. 1979;31:263–6.CrossRef
go back to reference Bandeira MB, Queiroz IMS, Fernandes SKSC, et al. Evaluation of surface roughness of monolithic zirconia after using different polishing kits. Pesq Bras Odontoped Clin Integr. 2017;17(1):e2984–e90.CrossRef Bandeira MB, Queiroz IMS, Fernandes SKSC, et al. Evaluation of surface roughness of monolithic zirconia after using different polishing kits. Pesq Bras Odontoped Clin Integr. 2017;17(1):e2984–e90.CrossRef
go back to reference Bollen CM, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater. 1997;13:258–69.CrossRefPubMed Bollen CM, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater. 1997;13:258–69.CrossRefPubMed
go back to reference Cerci BB, Roman LS, Guariza-Filho O, et al. Dental enamel roughness with different acid etching times: atomic force microscopy study. Eur J Gen Dent. 2012;1(3):187–91.CrossRef Cerci BB, Roman LS, Guariza-Filho O, et al. Dental enamel roughness with different acid etching times: atomic force microscopy study. Eur J Gen Dent. 2012;1(3):187–91.CrossRef
go back to reference Esquivel-Upshaw JF, Kim MJ, Hsu SM, et al. Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns. J Dent. 2017;68:19–27.CrossRefPubMedPubMedCentral Esquivel-Upshaw JF, Kim MJ, Hsu SM, et al. Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns. J Dent. 2017;68:19–27.CrossRefPubMedPubMedCentral
go back to reference Field J, Waterhouse P, German M. Quantifying and qualifying surface changes on dental hard tissues in vitro. J Dent. 2010;38(3):182–90.CrossRefPubMed Field J, Waterhouse P, German M. Quantifying and qualifying surface changes on dental hard tissues in vitro. J Dent. 2010;38(3):182–90.CrossRefPubMed
go back to reference Hjerppe J, Närhi TO, Vallittu PK, et al. Surface roughness and the flexural and bend strength of zirconia after different surface treatment. J Prosthet Dent. 2016;116(4):577–83.CrossRefPubMed Hjerppe J, Närhi TO, Vallittu PK, et al. Surface roughness and the flexural and bend strength of zirconia after different surface treatment. J Prosthet Dent. 2016;116(4):577–83.CrossRefPubMed
go back to reference Holsinger DM, Wells MH, Scarbecz M, et al. Clinical evaluation and parental satisfaction with pediatric zirconia anterior crowns. Pediatr Dent. 2016;38(3):192–7.PubMed Holsinger DM, Wells MH, Scarbecz M, et al. Clinical evaluation and parental satisfaction with pediatric zirconia anterior crowns. Pediatr Dent. 2016;38(3):192–7.PubMed
go back to reference Janyavula S, Lawson N, Cakir D, et al. The wear of polished and glazed zirconia against enamel. J Prosthet Dent. 2013;109(1):22–9.CrossRefPubMed Janyavula S, Lawson N, Cakir D, et al. The wear of polished and glazed zirconia against enamel. J Prosthet Dent. 2013;109(1):22–9.CrossRefPubMed
go back to reference Johnson-Harris D, Chiquet B, Flaitz C, et al. Wear of primary tooth enamel by ceramic materials. Pediatr Dent. 2016;38(7):519–22. Johnson-Harris D, Chiquet B, Flaitz C, et al. Wear of primary tooth enamel by ceramic materials. Pediatr Dent. 2016;38(7):519–22.
go back to reference Jung YS, Lee JW, Choi YJ, et al. A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain. J Adv Prosthodont. 2010;2(3):111–5.CrossRefPubMedPubMedCentral Jung YS, Lee JW, Choi YJ, et al. A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain. J Adv Prosthodont. 2010;2(3):111–5.CrossRefPubMedPubMedCentral
go back to reference Khera SC, Carpenter CW, Vetter JD, et al. Anatomy of cusps of posterior teeth and their fracture potential. J Prosthet Dent. 1990;64(2):139–47.CrossRef Khera SC, Carpenter CW, Vetter JD, et al. Anatomy of cusps of posterior teeth and their fracture potential. J Prosthet Dent. 1990;64(2):139–47.CrossRef
go back to reference Kontos L, Schille C, Schweizer E, et al. Influence of surface treatment on the wear of solid zirconia. Acta Odontol Scand. 2013;71(3–4):482–7.CrossRefPubMed Kontos L, Schille C, Schweizer E, et al. Influence of surface treatment on the wear of solid zirconia. Acta Odontol Scand. 2013;71(3–4):482–7.CrossRefPubMed
go back to reference Lawson NC, Janyavula S, Syklawer S, et al. Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing. J Dent. 2014;42(12):1586–91.CrossRefPubMed Lawson NC, Janyavula S, Syklawer S, et al. Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing. J Dent. 2014;42(12):1586–91.CrossRefPubMed
go back to reference Mitov G, Heintze SD, Walz S, et al. Wear behavior of dental Y-TZP ceramic against natural enamel after different finishing procedures. Dent Mater. 2012;28(8):909–18.CrossRefPubMed Mitov G, Heintze SD, Walz S, et al. Wear behavior of dental Y-TZP ceramic against natural enamel after different finishing procedures. Dent Mater. 2012;28(8):909–18.CrossRefPubMed
go back to reference Mundhe K, Jain V, Pruthi G, et al. Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns. J Prosthet Dent. 2015;114(3):358–63.CrossRefPubMed Mundhe K, Jain V, Pruthi G, et al. Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns. J Prosthet Dent. 2015;114(3):358–63.CrossRefPubMed
go back to reference Nelson GV, Osborne JW, Gale EN, et al. A three-year clinical evaluation of composite resin and a high copper amalgam in posterior primary teeth. ASDC J Dent Child. 1980;47(6):414–8.PubMed Nelson GV, Osborne JW, Gale EN, et al. A three-year clinical evaluation of composite resin and a high copper amalgam in posterior primary teeth. ASDC J Dent Child. 1980;47(6):414–8.PubMed
go back to reference Oh WS, Delong R, Anusavice KJ. Factors affecting enamel and ceramic wear: a literature review. J Prosthet Dent. 2002;87(4):451–9.CrossRefPubMed Oh WS, Delong R, Anusavice KJ. Factors affecting enamel and ceramic wear: a literature review. J Prosthet Dent. 2002;87(4):451–9.CrossRefPubMed
go back to reference Pan Y, Wu G, Huang Z, et al. Effect of surface roughness on interlaminar peel and shear strength of CFRP/Mg laminates. Int J Adhes Adhes. 2017;79:1–7.CrossRef Pan Y, Wu G, Huang Z, et al. Effect of surface roughness on interlaminar peel and shear strength of CFRP/Mg laminates. Int J Adhes Adhes. 2017;79:1–7.CrossRef
go back to reference Passos SP, Torrealba Y, Major P, et al. In vitro wear behavior of zirconia opposing enamel: a systematic review. J Prosthodont. 2014;23(8):593–601.CrossRefPubMed Passos SP, Torrealba Y, Major P, et al. In vitro wear behavior of zirconia opposing enamel: a systematic review. J Prosthodont. 2014;23(8):593–601.CrossRefPubMed
go back to reference Passos S, Torrealba Y, Linke B, et al. Wear evaluation of dental Y-TZP opposing human enamel. Dent Mater. 2016;32:5–6.CrossRef Passos S, Torrealba Y, Linke B, et al. Wear evaluation of dental Y-TZP opposing human enamel. Dent Mater. 2016;32:5–6.CrossRef
go back to reference Sandoval GC, Castanon GAM, Marin NP, et al. Surface roughness and hardness evaluation of some base metal alloys and denture base acrylics used for oral rehabilitation. J Mater Lett. 2015;144:100–5.CrossRef Sandoval GC, Castanon GAM, Marin NP, et al. Surface roughness and hardness evaluation of some base metal alloys and denture base acrylics used for oral rehabilitation. J Mater Lett. 2015;144:100–5.CrossRef
go back to reference Schaefer DM, Carpenter M, Gady B, et al. Surface roughness and its influence on particle adhesion using atomic force techniques. J Adhes Sci Technol. 1995;9:1049–62.CrossRef Schaefer DM, Carpenter M, Gady B, et al. Surface roughness and its influence on particle adhesion using atomic force techniques. J Adhes Sci Technol. 1995;9:1049–62.CrossRef
go back to reference Song F, Koo H, Ren D. Effects of material properties on bacterial adhesion and biofilm formation. J Dent Res. 2015;94(8):1027–34.CrossRefPubMed Song F, Koo H, Ren D. Effects of material properties on bacterial adhesion and biofilm formation. J Dent Res. 2015;94(8):1027–34.CrossRefPubMed
go back to reference Stober T, Bermejo Jl, Rammelsberg P, et al. Enamel wear caused by monolithic zirconia crowns after 6 months of clinical use. J Oral Rehabil. 2014;41:314–22.CrossRefPubMed Stober T, Bermejo Jl, Rammelsberg P, et al. Enamel wear caused by monolithic zirconia crowns after 6 months of clinical use. J Oral Rehabil. 2014;41:314–22.CrossRefPubMed
go back to reference Teicher U, Rosenbaum T, Nestler A, et al. Characterization of the surface roughness of milled carbon fiber reinforced plastic structures. Procedia CIRP. 2017;66:199–203.CrossRef Teicher U, Rosenbaum T, Nestler A, et al. Characterization of the surface roughness of milled carbon fiber reinforced plastic structures. Procedia CIRP. 2017;66:199–203.CrossRef
go back to reference Theriot AL, Frey GN, Ontiveros JC, et al. Gloss and surface roughness of anterior pediatric zirconia crowns. J Dent Child. 2017;84(3):115–9. Theriot AL, Frey GN, Ontiveros JC, et al. Gloss and surface roughness of anterior pediatric zirconia crowns. J Dent Child. 2017;84(3):115–9.
go back to reference Walia T, Salami AA, Bashiri R, et al. A randomised controlled trial of three aesthetic full-coronal restorations in primary maxillary teeth. Eur J Paediatr Dent. 2014;15(2):113–8.CrossRefPubMed Walia T, Salami AA, Bashiri R, et al. A randomised controlled trial of three aesthetic full-coronal restorations in primary maxillary teeth. Eur J Paediatr Dent. 2014;15(2):113–8.CrossRefPubMed
go back to reference Walia T, Bashiri R, Alaghband F. Split mouth clinical study evaluating stainless steel crowns and primary zirconia crowns in pulp treated primary molars. Int J Pediatr Dent. 2015;25(S1):26. Walia T, Bashiri R, Alaghband F. Split mouth clinical study evaluating stainless steel crowns and primary zirconia crowns in pulp treated primary molars. Int J Pediatr Dent. 2015;25(S1):26.
go back to reference Wilson PR, Beynon AD. Mineralization differences between human deciduous and permanent enamel measured by quantitative microradiography. Arch Oral Biol. 1989;34(2):85–8.CrossRefPubMed Wilson PR, Beynon AD. Mineralization differences between human deciduous and permanent enamel measured by quantitative microradiography. Arch Oral Biol. 1989;34(2):85–8.CrossRefPubMed
go back to reference Yilbas Z, Hasmi MSJ. Surface roughness measurement using an optical system. J Mater Process Technol. 1999;88(1–3):10–22.CrossRef Yilbas Z, Hasmi MSJ. Surface roughness measurement using an optical system. J Mater Process Technol. 1999;88(1–3):10–22.CrossRef
go back to reference Zimmerman JA, Feigal RJ, Till MJ, et al. Parental attitudes on restorative materials as factors influencing current use in pediatric dentistry. Pediatr Dent. 2009;31(1):63–7.PubMed Zimmerman JA, Feigal RJ, Till MJ, et al. Parental attitudes on restorative materials as factors influencing current use in pediatric dentistry. Pediatr Dent. 2009;31(1):63–7.PubMed
go back to reference Zinelis S, Eliades T, Eliades G, et al. Comparative assessment of the roughness, hardness, and wear resistance of aesthetic bracket materials. Dent Mater. 2005;21(9):890–4.CrossRefPubMed Zinelis S, Eliades T, Eliades G, et al. Comparative assessment of the roughness, hardness, and wear resistance of aesthetic bracket materials. Dent Mater. 2005;21(9):890–4.CrossRefPubMed
Metadata
Title
Comparative evaluation of surface roughness of posterior primary zirconia crowns
Authors
T. Walia
C. Brigi
Abdel Rahman M. M. KhirAllah
Publication date
01-02-2019
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Paediatric Dentistry / Issue 1/2019
Print ISSN: 1818-6300
Electronic ISSN: 1996-9805
DOI
https://doi.org/10.1007/s40368-018-0382-4