Skip to main content
Top
Published in: Neuroradiology 5/2010

01-05-2010 | Interventional Neuroradiology

Coil embolization of anterior circulation aneurysms supported by the Solitaire™ AB Neurovascular Remodeling Device

Authors: Joachim Klisch, Christin Clajus, Vojtech Sychra, Cornelia Eger, Christoph Strasilla, Steffen Rosahl, Rüdiger Gerlach, Ingrid Bär, Heinrich Hoch, Uta Herbon, Ljubisa Borota, Per Jonasson, Thomas Liebig

Published in: Neuroradiology | Issue 5/2010

Login to get access

Abstract

Introduction

The purpose of the study is to evaluate patients with wide-necked or complex aneurysms of the anterior circulation who underwent Solitaire™ AB Neurovascular Remodeling Device-assisted coil embolization.

Methods

From February 2008 to March 2009, consecutive data were collected from 45 patients with anterior circulation aneurysms. Eighteen of the patients presented with acute subarachnoid hemorrhage. Forty-six aneurysms were treated with the aid of different applications (n = 49) of the Solitaire™ AB Remodeling Device followed by standard coiling procedure (n = 43) using bioactive coils or/and bare coils.

Results

Successful positioning of the remodeling device was obtained in 95.9% of the cases. There were two thromboembolic complications (4.1%) and one severe vasospasm requiring retrieval of the device. Permanent procedural morbidity was observed in one patient (2%). The proportion of patients in whom Raymond class 1 occlusion was obtained was 53.5% (n = 23). Raymond class 2 occlusion was achieved in 42% (n = 18) and Raymond class 3 occlusion in 4.7% (n = 2). Thirty-nine patients left the hospital with a good clinical status.

Conclusion

The initial technical and clinical results of Solitaire™ AB device-assisted coiling of aneurysms in the anterior circulation are highly encouraging. This technique may enhance the possibilities of the endovascular treatment of these aneurysms in clinical routine.
Literature
1.
go back to reference Akpek S, Arat A, Morsi H, Klucznick RP, Strother CM, Mawad ME (2005) Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol 26:1223–1231PubMed Akpek S, Arat A, Morsi H, Klucznick RP, Strother CM, Mawad ME (2005) Self-expandable stent-assisted coiling of wide-necked intracranial aneurysms: a single-center experience. AJNR Am J Neuroradiol 26:1223–1231PubMed
2.
go back to reference Alfke K, Straube T, Dörner L, Mehdorn M, Jansen O (2004) Treatment of intracranial broad-neck aneurysms with a new self-expanding stent and coil embolization. AJNR Am J Neuroradiol 25:584–591PubMed Alfke K, Straube T, Dörner L, Mehdorn M, Jansen O (2004) Treatment of intracranial broad-neck aneurysms with a new self-expanding stent and coil embolization. AJNR Am J Neuroradiol 25:584–591PubMed
3.
go back to reference Benitez RP, Silva MT, Klem J, Veznedaroglu E, Rosenwasser RH (2004) Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery 54:1359–1367CrossRefPubMed Benitez RP, Silva MT, Klem J, Veznedaroglu E, Rosenwasser RH (2004) Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery 54:1359–1367CrossRefPubMed
4.
go back to reference Biondi A, Janardhan V, Katz JM, Salvaggio KRN, Riina HA, Gobin YP (2007) Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61:460–469CrossRefPubMed Biondi A, Janardhan V, Katz JM, Salvaggio KRN, Riina HA, Gobin YP (2007) Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. Neurosurgery 61:460–469CrossRefPubMed
5.
go back to reference Broadbent LP, Moran CJ, Cross DT III, Derdeyn CP (2003) Management of neuroform stent dislodgement and misplacement. AJNR Am J Neuroradiol 24:1819–1822PubMed Broadbent LP, Moran CJ, Cross DT III, Derdeyn CP (2003) Management of neuroform stent dislodgement and misplacement. AJNR Am J Neuroradiol 24:1819–1822PubMed
6.
go back to reference Byrne JV, Sohn MJ, Molyneux AJ, Chir B (1999) Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 90:656–663CrossRefPubMed Byrne JV, Sohn MJ, Molyneux AJ, Chir B (1999) Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 90:656–663CrossRefPubMed
7.
go back to reference Jahromi BS, Mocco J, Bang JA, Gologorsky Y, Siddiqui AH, Horowitz MB, Hopkins LN, Levy EI (2008) Clinical and angiographic outcome after endovascular management of giant intracranial aneurysms. Neurosurgery 63:662–674 discussion 674–675CrossRefPubMed Jahromi BS, Mocco J, Bang JA, Gologorsky Y, Siddiqui AH, Horowitz MB, Hopkins LN, Levy EI (2008) Clinical and angiographic outcome after endovascular management of giant intracranial aneurysms. Neurosurgery 63:662–674 discussion 674–675CrossRefPubMed
8.
go back to reference Kelly ME, Turner R, Gonugunta V, Woo HH, Rasmussen PA, Masaryk TJ, Fiorella D (2007) Stent reconstruction of wide-necked aneurysms across the circle of Willis. Neurosurgery 61:249–254 discussion 254–255CrossRefPubMed Kelly ME, Turner R, Gonugunta V, Woo HH, Rasmussen PA, Masaryk TJ, Fiorella D (2007) Stent reconstruction of wide-necked aneurysms across the circle of Willis. Neurosurgery 61:249–254 discussion 254–255CrossRefPubMed
9.
go back to reference Lee YJ, Kim DJ, Suh SH, Lee SK, Kim J, Kim DI (2005) Stent-assisted coil embolization of intracranial wide-necked aneurysms. Neuroradiology 47:680–689CrossRefPubMed Lee YJ, Kim DJ, Suh SH, Lee SK, Kim J, Kim DI (2005) Stent-assisted coil embolization of intracranial wide-necked aneurysms. Neuroradiology 47:680–689CrossRefPubMed
10.
go back to reference Lylyk P, Ferrario A, Pasbon B, Miranda C, Doroszuk G (2005) Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms. J Neurosurg 102:235–241CrossRefPubMed Lylyk P, Ferrario A, Pasbon B, Miranda C, Doroszuk G (2005) Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysms. J Neurosurg 102:235–241CrossRefPubMed
11.
go back to reference Wanke I, Doerfler A, Schoch B, Stolke D, Forsting M (2003) Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience. AJNR Am J Neuroradiol 24:1192–1199PubMed Wanke I, Doerfler A, Schoch B, Stolke D, Forsting M (2003) Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience. AJNR Am J Neuroradiol 24:1192–1199PubMed
12.
go back to reference Hope JK, Byrne JV, Molyneux AJ (1999) Factors influencing successful angiographic occlusion of aneurysms treated by coil embolization. AJNR 20:391–399PubMed Hope JK, Byrne JV, Molyneux AJ (1999) Factors influencing successful angiographic occlusion of aneurysms treated by coil embolization. AJNR 20:391–399PubMed
14.
go back to reference Kurre W, Berkefeld J (2008) Materials and techniques for coiling of cerebral aneurysms: how much scientific evidence do we have? Neuroradiology 50:909–927CrossRefPubMed Kurre W, Berkefeld J (2008) Materials and techniques for coiling of cerebral aneurysms: how much scientific evidence do we have? Neuroradiology 50:909–927CrossRefPubMed
15.
go back to reference Fiorella D, Albuquerque FC, Woo H, Rasmussen PA, Masaryk TJ, McDougall CG (2006) Neuroform in-stent stenosis: incidence, natural history, and treatment strategies. Neurosurgery 59:34–42CrossRefPubMed Fiorella D, Albuquerque FC, Woo H, Rasmussen PA, Masaryk TJ, McDougall CG (2006) Neuroform in-stent stenosis: incidence, natural history, and treatment strategies. Neurosurgery 59:34–42CrossRefPubMed
16.
go back to reference Fiorella D, Albuquerque FC, Deshmukh VR, McDougall CG (2005) Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3–6-mo) follow-up. Neurosurgery 56:1191–1202CrossRefPubMed Fiorella D, Albuquerque FC, Deshmukh VR, McDougall CG (2005) Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3–6-mo) follow-up. Neurosurgery 56:1191–1202CrossRefPubMed
17.
go back to reference Lubicz B, Leclerc X, Levivier M, Brotchi J, Pruvo JP, Lejeune JP, Baleriaux D (2006) Retractable self-expandable stent for endovascular treatment of wide-necked intracranial aneurysms: preliminary experience. Neurosurgery 58:451–457PubMed Lubicz B, Leclerc X, Levivier M, Brotchi J, Pruvo JP, Lejeune JP, Baleriaux D (2006) Retractable self-expandable stent for endovascular treatment of wide-necked intracranial aneurysms: preliminary experience. Neurosurgery 58:451–457PubMed
18.
go back to reference Lubicz B, Collignon L, Lefranc F, Bruneau M, Brotchi J, Balériaux D, De Witte O (2008) Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents. Neuroradiology 50:499–507CrossRefPubMed Lubicz B, Collignon L, Lefranc F, Bruneau M, Brotchi J, Balériaux D, De Witte O (2008) Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents. Neuroradiology 50:499–507CrossRefPubMed
19.
go back to reference Lylyk P, Cohen JE, Ferrario A, Ceratto R, Miranda C (2002) Partially clipped intracranial aneurysm obliterated with combined stent and coil implantation. J Endovasc Ther 9:160–164CrossRefPubMed Lylyk P, Cohen JE, Ferrario A, Ceratto R, Miranda C (2002) Partially clipped intracranial aneurysm obliterated with combined stent and coil implantation. J Endovasc Ther 9:160–164CrossRefPubMed
20.
go back to reference Mawad ME, Cekirge S, Ciceri E, Saatci I (2002) Endovascular treatment of giant and large intracranial aneurysms by using a combination of stent placement and liquid polymer injection. J Neurosurg 96:474–482CrossRefPubMed Mawad ME, Cekirge S, Ciceri E, Saatci I (2002) Endovascular treatment of giant and large intracranial aneurysms by using a combination of stent placement and liquid polymer injection. J Neurosurg 96:474–482CrossRefPubMed
21.
go back to reference Lefkowitz MA, Gobin YP, Akiba Y, Duckwiler GR, Murayama Y, Guglielmi G, Martin NA, Vinuela F (1999) Balloon-assisted Guglielmi detachable coiling of wide-necked aneurysms, II: clinical results. Neurosurgery 45:531–536CrossRefPubMed Lefkowitz MA, Gobin YP, Akiba Y, Duckwiler GR, Murayama Y, Guglielmi G, Martin NA, Vinuela F (1999) Balloon-assisted Guglielmi detachable coiling of wide-necked aneurysms, II: clinical results. Neurosurgery 45:531–536CrossRefPubMed
22.
go back to reference Cottier JP, Pasco A, Gallas S, Gabrillargues J, Cognard C, Drouineau J, Brunereau L, Herbreteau D (2001) Utility of balloon-assisted Guglielmi detachable coiling in the treatment of 49 cerebral aneurysms: a retrospective, multicenter study. AJNR Am J Neuroradiol 22:345–351PubMed Cottier JP, Pasco A, Gallas S, Gabrillargues J, Cognard C, Drouineau J, Brunereau L, Herbreteau D (2001) Utility of balloon-assisted Guglielmi detachable coiling in the treatment of 49 cerebral aneurysms: a retrospective, multicenter study. AJNR Am J Neuroradiol 22:345–351PubMed
23.
go back to reference Mocco J, Snyder KV, Albuquerque FC, Bendok BR, Boulos AS, Carpenter JS, Fiorella DJ, Hoh BL, Howington JU, Jankowitz BT, Liebman KM, Rai AT, Rodriguez-Mercado R, Siddiqui AH, Veznedaroglu E, Hopkins LN, Levy EI (2009) Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. J Neurosurg 110:35–39CrossRefPubMed Mocco J, Snyder KV, Albuquerque FC, Bendok BR, Boulos AS, Carpenter JS, Fiorella DJ, Hoh BL, Howington JU, Jankowitz BT, Liebman KM, Rai AT, Rodriguez-Mercado R, Siddiqui AH, Veznedaroglu E, Hopkins LN, Levy EI (2009) Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. J Neurosurg 110:35–39CrossRefPubMed
24.
go back to reference Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) Reconstruction technique in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results: apropos of 56 cases [in French]. J Neuroradiol 24:30–44PubMed Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) Reconstruction technique in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results: apropos of 56 cases [in French]. J Neuroradiol 24:30–44PubMed
25.
go back to reference Pumar JM, Blanco M, Vazquez F, Castineira JA, Guimaraens L, Garcia-Allut A (2005) Preliminary experience with Leo self-expanding stent for the treatment of intracranial aneurysms. AJNR Am J Neuroradiol 26:2573–2577PubMed Pumar JM, Blanco M, Vazquez F, Castineira JA, Guimaraens L, Garcia-Allut A (2005) Preliminary experience with Leo self-expanding stent for the treatment of intracranial aneurysms. AJNR Am J Neuroradiol 26:2573–2577PubMed
26.
go back to reference Wanke I, Forsting M (2008) Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neuroradiology 50:991–998CrossRefPubMed Wanke I, Forsting M (2008) Stents for intracranial wide-necked aneurysms: more than mechanical protection. Neuroradiology 50:991–998CrossRefPubMed
27.
go back to reference Sedat J, Chau Y, Mondot L, Vargas J, Szapiro J, Lonjon M (2009) Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results. Neuroradiology . doi:10.1007/s00234-009-0502-2 PubMed Sedat J, Chau Y, Mondot L, Vargas J, Szapiro J, Lonjon M (2009) Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results. Neuroradiology . doi:10.​1007/​s00234-009-0502-2 PubMed
28.
go back to reference The American Society of Interventional and Therapeutic Neuroradiology (2008) ASITN: standards of practice. The American Society of Interventional and Therapeutic Neuroradiology, Fairfax The American Society of Interventional and Therapeutic Neuroradiology (2008) ASITN: standards of practice. The American Society of Interventional and Therapeutic Neuroradiology, Fairfax
29.
go back to reference Henkes H, Flesser A, Brew S, Miloslavski E, Doerfler A, Felber S, Monstadt H, Kuehne D (2003) A novel microcatheter-delivered, highly-flexible and fully-retrievable stent, specifically designed for intracranial use. Interv Neuroradiol 9:391–393 Henkes H, Flesser A, Brew S, Miloslavski E, Doerfler A, Felber S, Monstadt H, Kuehne D (2003) A novel microcatheter-delivered, highly-flexible and fully-retrievable stent, specifically designed for intracranial use. Interv Neuroradiol 9:391–393
30.
go back to reference Doerfler A, Becker WP, Wanke I, Goericke SL, Mueller KM, Blechschmid N, Flesser A, Monstadt H, Forsting M (2005) A novel flexible, retrievable endovascular stent system for small-vessel anatomy: preliminary in vivo data. AJNR Am J Neuroradiol 26:862–868PubMed Doerfler A, Becker WP, Wanke I, Goericke SL, Mueller KM, Blechschmid N, Flesser A, Monstadt H, Forsting M (2005) A novel flexible, retrievable endovascular stent system for small-vessel anatomy: preliminary in vivo data. AJNR Am J Neuroradiol 26:862–868PubMed
31.
go back to reference Liebig T, Henkes H, Reinartz J, Milolavski E, Kühne D (2006) A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion. Neuroradiology 48:471–478CrossRefPubMed Liebig T, Henkes H, Reinartz J, Milolavski E, Kühne D (2006) A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion. Neuroradiology 48:471–478CrossRefPubMed
32.
go back to reference Yavuz K, Geyik S, Pamuk AG, Koc O, Saatci I, Cekirge HS (2007) Immediate and midterm follow-up results of using an electrodetachable, fully retrievable SOLO stent system in the endovascular coil occlusion of wide-necked cerebral aneurysms. J Neurosurg 107:49–55CrossRefPubMed Yavuz K, Geyik S, Pamuk AG, Koc O, Saatci I, Cekirge HS (2007) Immediate and midterm follow-up results of using an electrodetachable, fully retrievable SOLO stent system in the endovascular coil occlusion of wide-necked cerebral aneurysms. J Neurosurg 107:49–55CrossRefPubMed
33.
go back to reference Raymond J, Roy D (1997) Safety and efficacy of endovascular treatment of acutely ruptured aneurysms. Neurosurgery 41:1235–1246CrossRefPubMed Raymond J, Roy D (1997) Safety and efficacy of endovascular treatment of acutely ruptured aneurysms. Neurosurgery 41:1235–1246CrossRefPubMed
34.
go back to reference Bonita R, Beaglehole R (1988) Modification of Rankin Scale: recovery of motor function after stroke. Stroke 19:1497–1500PubMed Bonita R, Beaglehole R (1988) Modification of Rankin Scale: recovery of motor function after stroke. Stroke 19:1497–1500PubMed
35.
go back to reference Lee VH, Connolly HM, Fulgham JR, Manno EM, Brown RD Jr, Wijdicks EF (2006) Tako-tsubo cardiomyopathy in aneurysmal subarachnoid hemorrhage: an underappreciated ventricular dysfunction. J Neurosurg 105:264–267CrossRefPubMed Lee VH, Connolly HM, Fulgham JR, Manno EM, Brown RD Jr, Wijdicks EF (2006) Tako-tsubo cardiomyopathy in aneurysmal subarachnoid hemorrhage: an underappreciated ventricular dysfunction. J Neurosurg 105:264–267CrossRefPubMed
36.
go back to reference Mordasini P, Walser A, Gralla J, Wiest R, Ozdoba C, Reinert M, Schroth G (2008) Stent placement in the endovascular treatment of intracranial aneurysms. Swiss Med Wkly 138:646–654PubMed Mordasini P, Walser A, Gralla J, Wiest R, Ozdoba C, Reinert M, Schroth G (2008) Stent placement in the endovascular treatment of intracranial aneurysms. Swiss Med Wkly 138:646–654PubMed
37.
go back to reference Kelly ME, Turner RD 4th, Moskowitz SI, Gonugunta V, Hussain MS, Fiorella D (2008) Delayed migration of a self-expanding intracranial microstent. AJNR Am J Neuroradiol 29:1959–1960CrossRefPubMed Kelly ME, Turner RD 4th, Moskowitz SI, Gonugunta V, Hussain MS, Fiorella D (2008) Delayed migration of a self-expanding intracranial microstent. AJNR Am J Neuroradiol 29:1959–1960CrossRefPubMed
38.
go back to reference Lubicz B, Bandeira A, Bruneau M, Dewindt A, Baleriaux D, De Witte O (2009) Stenting is improving and stabilizing anatomical results of coiled intracranial aneurysms. Neuroradiology . doi:10.1007/s00234-009-0519-6 Lubicz B, Bandeira A, Bruneau M, Dewindt A, Baleriaux D, De Witte O (2009) Stenting is improving and stabilizing anatomical results of coiled intracranial aneurysms. Neuroradiology . doi:10.​1007/​s00234-009-0519-6
40.
go back to reference Tateshima S, Tanishita K, Hakata Y, Tanoue SY, Viñuela F (2009) Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent. J Neurosurg 111:22–27CrossRefPubMed Tateshima S, Tanishita K, Hakata Y, Tanoue SY, Viñuela F (2009) Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent. J Neurosurg 111:22–27CrossRefPubMed
41.
go back to reference Henkes H, Lowens S, Preiss H, Reinartz J, Miloslavski E, Kühne D (2006) A new device for endovascular coil retrieval from intracranial vessels: alligator retrieval device. AJNR Am J Neuroradiol 27:327–329PubMed Henkes H, Lowens S, Preiss H, Reinartz J, Miloslavski E, Kühne D (2006) A new device for endovascular coil retrieval from intracranial vessels: alligator retrieval device. AJNR Am J Neuroradiol 27:327–329PubMed
42.
go back to reference Panagiotopoulos V, Gizewski E, Wanke I (2008) Intra-aneurysmal navigation technique for stenting of a wide-neck basilar aneurysm with a new self-expandable stent: technical note. Minim Invasive Neurosurg 51:240–243CrossRefPubMed Panagiotopoulos V, Gizewski E, Wanke I (2008) Intra-aneurysmal navigation technique for stenting of a wide-neck basilar aneurysm with a new self-expandable stent: technical note. Minim Invasive Neurosurg 51:240–243CrossRefPubMed
43.
go back to reference Horowitz M, Levy E, Sauvaqeau E, Genevro J, Guterman LR, Hanel R, Wehman C, Gupta R, Jovin T (2006) Intra/extra-aneurysmal stent placement for management of complex and wide-necked-bifurcation aneurysms: eight cases using the waffle cone technique. Neurosurgery 58(4):258–262 discussion 262 Horowitz M, Levy E, Sauvaqeau E, Genevro J, Guterman LR, Hanel R, Wehman C, Gupta R, Jovin T (2006) Intra/extra-aneurysmal stent placement for management of complex and wide-necked-bifurcation aneurysms: eight cases using the waffle cone technique. Neurosurgery 58(4):258–262 discussion 262
44.
go back to reference Siddiqui MA, Bhattacharya JJ, Lindsay KW, Jenkins S (2009) Horizontal stent-assisted coil embolisation of wide-necked intracranial aneurysms with the Enterprise stent—a case series with early angiographic follow-up. Neuroradiology 51:411–418CrossRefPubMed Siddiqui MA, Bhattacharya JJ, Lindsay KW, Jenkins S (2009) Horizontal stent-assisted coil embolisation of wide-necked intracranial aneurysms with the Enterprise stent—a case series with early angiographic follow-up. Neuroradiology 51:411–418CrossRefPubMed
Metadata
Title
Coil embolization of anterior circulation aneurysms supported by the Solitaire™ AB Neurovascular Remodeling Device
Authors
Joachim Klisch
Christin Clajus
Vojtech Sychra
Cornelia Eger
Christoph Strasilla
Steffen Rosahl
Rüdiger Gerlach
Ingrid Bär
Heinrich Hoch
Uta Herbon
Ljubisa Borota
Per Jonasson
Thomas Liebig
Publication date
01-05-2010
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 5/2010
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-009-0568-x

Other articles of this Issue 5/2010

Neuroradiology 5/2010 Go to the issue