Skip to main content
Top
Published in: BMC Ophthalmology 1/2014

Open Access 01-12-2014 | Research article

Clinical utility of spectral analysis of intraocular pressure pulse wave

Authors: Magdalena Asejczyk-Widlicka, Patrycja Krzyżanowska-Berkowska, Małgorzata Kowalska, D Robert Iskander

Published in: BMC Ophthalmology | Issue 1/2014

Login to get access

Abstract

Background

To evaluate the clinical utility of spectral analysis of intraocular pressure pulse wave in healthy eyes of a control group (CG), patients having glaucomatous optic disc appearance or ocular hypertension, and patients with primary open angle glaucoma or primary angle closure glaucoma.

Methods

This is a prospective study that enrolled 296 patients from a single glaucoma clinic. Age matched CG consisted of 62 individuals. Subjects underwent comprehensive clinical diagnostic procedures including intraocular pressure (IOP) measurement with dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT). DCT time series were analyzed with custom written software that included signal preprocessing, filtering and spectral analysis. An amplitude and energy content analysis, which takes into account non-stationarity of signals but also provides methodology that is independent of IOP and ocular pulse amplitude (OPA) levels, was applied. Spectral content up to the 6th harmonic of the pressure pulse wave was considered. Statistical analyses included descriptive statistics, normality test, and a multicomparison of medians for independent groups using Kruskal-Wallis test.

Results

GAT IOP showed statistical significance (Kruskal-Willis test p < 0.05) for three out of 10 considered multiple comparisons, DCT IOP and OPA showed statistically significant results in five and seven cases, respectively. Changes in heart rate and central corneal thickness between the groups were statistically significant in two cases. None of the above parameters showed statistically significant differences between CG and the suspects with glaucomatous optic disc appearance (GODA). On the other hand, spectral analysis showed statistically significant differences for that case.

Conclusions

Spectral analysis of the DCT signals was the only method showing statistically significant differences between healthy eyes and those of GODA suspects.
Appendix
Available only for authorised users
Literature
1.
go back to reference Cook C, Foster P: Epidemiology of glaucoma: what’s new?. Can J Ophthalmol. 2012, 47: 223-226. 10.1016/j.jcjo.2012.02.003.CrossRefPubMed Cook C, Foster P: Epidemiology of glaucoma: what’s new?. Can J Ophthalmol. 2012, 47: 223-226. 10.1016/j.jcjo.2012.02.003.CrossRefPubMed
2.
go back to reference Chung HS, Harris A, Evans DW, Kagemann L, Garzozi HJ, Martin B: Vascular aspects in the pathophysiology of glaucomatous optic neuropathy. Surv Ophthalmol. 1999, 43 (Suppl 1): S43-S50.CrossRefPubMed Chung HS, Harris A, Evans DW, Kagemann L, Garzozi HJ, Martin B: Vascular aspects in the pathophysiology of glaucomatous optic neuropathy. Surv Ophthalmol. 1999, 43 (Suppl 1): S43-S50.CrossRefPubMed
3.
go back to reference Wang Y, Henson DB: Diagnostic performance of visual field test using subsets of the 24–2 test pattern for early glaucomatous field loss. Invest Ophthalmol Vis Sci. 2013, 54: 756-761. 10.1167/iovs.12-10468.CrossRefPubMed Wang Y, Henson DB: Diagnostic performance of visual field test using subsets of the 24–2 test pattern for early glaucomatous field loss. Invest Ophthalmol Vis Sci. 2013, 54: 756-761. 10.1167/iovs.12-10468.CrossRefPubMed
4.
go back to reference Liang SY, Lee GA, Shields D: Self-tonometry in glaucoma management-past, present and future. Surv Ophthalmol. 2009, 54: 450-462. 10.1016/j.survophthal.2009.04.006.CrossRefPubMed Liang SY, Lee GA, Shields D: Self-tonometry in glaucoma management-past, present and future. Surv Ophthalmol. 2009, 54: 450-462. 10.1016/j.survophthal.2009.04.006.CrossRefPubMed
5.
go back to reference Singh K, Shrivastava A: Intraocular pressure fluctuations: how much do they matter?. Curr Opin Ophthalmol. 2009, 20: 84-87. 10.1097/ICU.0b013e328324e6c4.CrossRefPubMed Singh K, Shrivastava A: Intraocular pressure fluctuations: how much do they matter?. Curr Opin Ophthalmol. 2009, 20: 84-87. 10.1097/ICU.0b013e328324e6c4.CrossRefPubMed
6.
go back to reference Deokule S, Weinreb RN: Relationships among systematic blood pressure, intraocular pressure, and open angle glaucoma. Can J Ophthalmol. 2008, 43: 302-307. 10.3129/i08-061.CrossRefPubMed Deokule S, Weinreb RN: Relationships among systematic blood pressure, intraocular pressure, and open angle glaucoma. Can J Ophthalmol. 2008, 43: 302-307. 10.3129/i08-061.CrossRefPubMed
7.
go back to reference Zion IB, Harris A, Siesky B, Shulman S, McCranor L, Garzozi HJ: Pulsatile ocular blood flow: relationship with flow velocities in vessels supplying the retina and choroid. Br J Ophthalmol. 2007, 91: 882-884. 10.1136/bjo.2006.108340.CrossRefPubMedPubMedCentral Zion IB, Harris A, Siesky B, Shulman S, McCranor L, Garzozi HJ: Pulsatile ocular blood flow: relationship with flow velocities in vessels supplying the retina and choroid. Br J Ophthalmol. 2007, 91: 882-884. 10.1136/bjo.2006.108340.CrossRefPubMedPubMedCentral
8.
go back to reference Grieshaber MC, Katamay R, Gugleta K, Kochkorov A, Flammer J, Orgul S: Relationship between ocular pulse amplitude and systemic blood pressure measurements. Acta Ophthalmol. 2009, 87: 329-334. 10.1111/j.1755-3768.2008.01217.x.CrossRefPubMed Grieshaber MC, Katamay R, Gugleta K, Kochkorov A, Flammer J, Orgul S: Relationship between ocular pulse amplitude and systemic blood pressure measurements. Acta Ophthalmol. 2009, 87: 329-334. 10.1111/j.1755-3768.2008.01217.x.CrossRefPubMed
9.
go back to reference Choi J, Lee J, Park SB, Lee KS, Sung KR, Kook MS: Factors affecting ocular pulse amplitude in eyes with open angle glaucoma and glaucoma-suspect eyes. Acta Ophthalmol. 2012, 90: 552-558. 10.1111/j.1755-3768.2010.01954.x.CrossRefPubMed Choi J, Lee J, Park SB, Lee KS, Sung KR, Kook MS: Factors affecting ocular pulse amplitude in eyes with open angle glaucoma and glaucoma-suspect eyes. Acta Ophthalmol. 2012, 90: 552-558. 10.1111/j.1755-3768.2010.01954.x.CrossRefPubMed
10.
go back to reference Dastiridou AI, Ginis HS, De Brouwere D, Tsilimbaris MK, Miltiadis K, Pallikaris IG: Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: the effect of intraocular pressure. Invest Ophthalmol Vis Sci. 2009, 50: 5718-5722. 10.1167/iovs.09-3760.CrossRefPubMed Dastiridou AI, Ginis HS, De Brouwere D, Tsilimbaris MK, Miltiadis K, Pallikaris IG: Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: the effect of intraocular pressure. Invest Ophthalmol Vis Sci. 2009, 50: 5718-5722. 10.1167/iovs.09-3760.CrossRefPubMed
11.
go back to reference Breusegem C, Fieuws S, Zeyen T, Stalmans I: The effect of trabeculectomy on ocular pulse amplitude. Invest Ophthalmol Vis Sci. 2010, 51: 231-235. 10.1167/iovs.09-3712.CrossRefPubMed Breusegem C, Fieuws S, Zeyen T, Stalmans I: The effect of trabeculectomy on ocular pulse amplitude. Invest Ophthalmol Vis Sci. 2010, 51: 231-235. 10.1167/iovs.09-3712.CrossRefPubMed
12.
go back to reference Kanngiesser HE, Kniestedt C, Robert YC: Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma. 2005, 14: 344-350. 10.1097/01.ijg.0000176936.16015.4e.CrossRefPubMed Kanngiesser HE, Kniestedt C, Robert YC: Dynamic contour tonometry: presentation of a new tonometer. J Glaucoma. 2005, 14: 344-350. 10.1097/01.ijg.0000176936.16015.4e.CrossRefPubMed
13.
go back to reference Kniestedt C, Kanngiesser HE: Dynamic contour tonometry. Ophthalmology. 2006, 103: 713-721. 10.1007/s00347-006-1387-7.CrossRef Kniestedt C, Kanngiesser HE: Dynamic contour tonometry. Ophthalmology. 2006, 103: 713-721. 10.1007/s00347-006-1387-7.CrossRef
14.
go back to reference Punjabi OS, Ho HV, Kniestedt C, Bostrom AG, Stamper RL, Lin SC: Intraocular pressure and ocular pulse amplitude comparison in different types of glaucoma using dynamic contour tonometry. Curr Eye Res. 2008, 31: 851-862.CrossRef Punjabi OS, Ho HV, Kniestedt C, Bostrom AG, Stamper RL, Lin SC: Intraocular pressure and ocular pulse amplitude comparison in different types of glaucoma using dynamic contour tonometry. Curr Eye Res. 2008, 31: 851-862.CrossRef
15.
go back to reference Boehm AG, Weber A, Pillunat LE, Koch R, Spoerl E: Dynamic contour tonometry in comparison to intracameral IOP measurements. Invest Ophthalmol Vis Sci. 2008, 49: 2472-2477. 10.1167/iovs.07-1366.CrossRefPubMed Boehm AG, Weber A, Pillunat LE, Koch R, Spoerl E: Dynamic contour tonometry in comparison to intracameral IOP measurements. Invest Ophthalmol Vis Sci. 2008, 49: 2472-2477. 10.1167/iovs.07-1366.CrossRefPubMed
16.
go back to reference Evans DW, Hosking SL, Embleton SJ, Morgan AJ, Bartlett JD: Spectral content of the intraocular pressure pulse wave: glaucoma patients versus normal subjects. Graefes Arch Clin Exp Ophthalmol. 2002, 240: 475-480. 10.1007/s00417-002-0460-4.CrossRefPubMed Evans DW, Hosking SL, Embleton SJ, Morgan AJ, Bartlett JD: Spectral content of the intraocular pressure pulse wave: glaucoma patients versus normal subjects. Graefes Arch Clin Exp Ophthalmol. 2002, 240: 475-480. 10.1007/s00417-002-0460-4.CrossRefPubMed
17.
go back to reference Božić M, Dukić ML, Stojković M: Spectral analysis of intraocular pressure pulse wave in open angle glaucomas and healthy eyes. Curr Eye Res. 2012, 37: 1019-1024. 10.3109/02713683.2012.700755.CrossRefPubMed Božić M, Dukić ML, Stojković M: Spectral analysis of intraocular pressure pulse wave in open angle glaucomas and healthy eyes. Curr Eye Res. 2012, 37: 1019-1024. 10.3109/02713683.2012.700755.CrossRefPubMed
18.
go back to reference Realini T, Weinreb RN, Hobbs G: Correlation of intraocular pressure measured with Goldmann and dynamic contour tonometry in normal and glaucomatous eyes. J Glaucoma. 2009, 18: 119-123. 10.1097/IJG.0b013e31817d23c7.CrossRefPubMedPubMedCentral Realini T, Weinreb RN, Hobbs G: Correlation of intraocular pressure measured with Goldmann and dynamic contour tonometry in normal and glaucomatous eyes. J Glaucoma. 2009, 18: 119-123. 10.1097/IJG.0b013e31817d23c7.CrossRefPubMedPubMedCentral
19.
go back to reference Ceruti P, Morbio R, Marraffa M, Marchini G: Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes. Eye. 2009, 23: 262-269. 10.1038/sj.eye.6703102.CrossRefPubMed Ceruti P, Morbio R, Marraffa M, Marchini G: Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes. Eye. 2009, 23: 262-269. 10.1038/sj.eye.6703102.CrossRefPubMed
20.
go back to reference Barleon L, Hoffmann EM, Berres M, Pfeiffer N, Grus FH: Comparison of dynamic contour tonometry and Goldmann applanation tonometry in glaucoma patients and healthy subjects. Am J Ophthalmol. 2006, 142: 583-590. 10.1016/j.ajo.2006.05.030.CrossRefPubMed Barleon L, Hoffmann EM, Berres M, Pfeiffer N, Grus FH: Comparison of dynamic contour tonometry and Goldmann applanation tonometry in glaucoma patients and healthy subjects. Am J Ophthalmol. 2006, 142: 583-590. 10.1016/j.ajo.2006.05.030.CrossRefPubMed
21.
go back to reference Savitzky A, Golay MJE: Smoothing and differentiation of data by simplified least squares procedures. Analytic Chem. 1964, 36: 1627-1639. 10.1021/ac60214a047.CrossRef Savitzky A, Golay MJE: Smoothing and differentiation of data by simplified least squares procedures. Analytic Chem. 1964, 36: 1627-1639. 10.1021/ac60214a047.CrossRef
22.
go back to reference Angelone A, Coulter NA: Respiratory sinus arrhythmia: a frequency dependent phenomenon. J Appl Physiol. 1964, 19: 479-482.PubMed Angelone A, Coulter NA: Respiratory sinus arrhythmia: a frequency dependent phenomenon. J Appl Physiol. 1964, 19: 479-482.PubMed
23.
go back to reference Kasprzak H, Iskander DR: Spectral characteristics of longitudinal corneal apex velocities and their relation to the cardiopulmonary system. Eye. 2007, 21: 1212-1219. 10.1038/sj.eye.6702578.CrossRefPubMed Kasprzak H, Iskander DR: Spectral characteristics of longitudinal corneal apex velocities and their relation to the cardiopulmonary system. Eye. 2007, 21: 1212-1219. 10.1038/sj.eye.6702578.CrossRefPubMed
Metadata
Title
Clinical utility of spectral analysis of intraocular pressure pulse wave
Authors
Magdalena Asejczyk-Widlicka
Patrycja Krzyżanowska-Berkowska
Małgorzata Kowalska
D Robert Iskander
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2014
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/1471-2415-14-30

Other articles of this Issue 1/2014

BMC Ophthalmology 1/2014 Go to the issue

Reviewer acknowledgement

Reviewer acknowledgement 2013