Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 7/2018

01-07-2018 | Clinical Investigation

Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement

Authors: Georg Böning, Willie M. Lüdemann, Julius Chapiro, Martin Jonczyk, Bernd Hamm, Rolf W. Günther, Bernhard Gebauer, Florian Streitparth

Published in: CardioVascular and Interventional Radiology | Issue 7/2018

Login to get access

Abstract

Purpose

The aim of this study was to evaluate the feasibility of cone-beam computed tomography (CBCT)-based real-time 3-D guidance of TIPSS placement and its positioning compared to standard guiding methods.

Materials and Methods

In a prospective, randomized, consecutive study design from 2015 to 2017, we included 21 patients in the CBCT guided group and 15 patients in the ultrasound (US) guided group. The prospective groups were compared in terms of success rate of intervention, portal vein puncture/procedure time, number of puncture attempts and applied dose. We furthermore retrospectively analyzed the last 23 consecutive cases with fluoroscopic guided portal vein puncture in terms of success rate, procedure time and applied dose, as it has been the standard method before US guidance.

Results

The median number of puncture attempts (CBCT: n = 2, US: n = 4, p = 0.249) and the mean puncture time (CBCT: 32 ± 45 min, US: 36 ± 45 min, p = 0.515) were not significantly different. There were furthermore no significant differences in the mean time needed for the total TIPSS procedure (CBCT: 115 ± 52 min, US: 112 ± 41 min, fluoroscopy: 110 ± 33 min, p = 0.996). The mean applied dose of the complete procedure also showed no statistically significant differences (CBCT: 563 ± 289 Gy·cm2, US: 322 ± 186 Gy·cm2, fluoroscopy: 469 ± 352 Gy·cm2, p = 0.069). There were no image guidance related complications.

Conclusion

Real-time 3-D needle guidance based on CBCT is feasible for TIPSS placement. In terms of puncture attempts, duration and dose, CBCT guidance was not inferior to the control groups and may be a valuable support for interventionists in TIPSS procedures.
Literature
1.
go back to reference Ketelsen D, Groezinger G, Maurer M, et al. Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: feasibility, technical success and procedural time. Eur Radiol. 2016;26(12):4277–83.CrossRefPubMed Ketelsen D, Groezinger G, Maurer M, et al. Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: feasibility, technical success and procedural time. Eur Radiol. 2016;26(12):4277–83.CrossRefPubMed
2.
go back to reference Rossle M, Haag K, Ochs A, et al. The transjugular intrahepatic portosystemic stent-shunt procedure for variceal bleeding. N Engl J Med. 1994;330(3):165–71.CrossRefPubMed Rossle M, Haag K, Ochs A, et al. The transjugular intrahepatic portosystemic stent-shunt procedure for variceal bleeding. N Engl J Med. 1994;330(3):165–71.CrossRefPubMed
3.
go back to reference Fidelman N, Kwan SW, LaBerge JM, Gordon RL, Ring EJ, Kerlan RK Jr. The transjugular intrahepatic portosystemic shunt: an update. AJR. 2012;199(4):746–55.CrossRefPubMed Fidelman N, Kwan SW, LaBerge JM, Gordon RL, Ring EJ, Kerlan RK Jr. The transjugular intrahepatic portosystemic shunt: an update. AJR. 2012;199(4):746–55.CrossRefPubMed
4.
go back to reference Farsad K, Kaufman JA. Novel image guidance techniques for portal vein targeting during transjugular intrahepatic portosystemic shunt creation. Tech Vasc Interv Radiol. 2016;19(1):10–20.CrossRefPubMed Farsad K, Kaufman JA. Novel image guidance techniques for portal vein targeting during transjugular intrahepatic portosystemic shunt creation. Tech Vasc Interv Radiol. 2016;19(1):10–20.CrossRefPubMed
5.
go back to reference Floridi C, Radaelli A, Abi-Jaoudeh N, et al. C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications. Radiol Med. 2014;119(7):521–32.CrossRefPubMedPubMedCentral Floridi C, Radaelli A, Abi-Jaoudeh N, et al. C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications. Radiol Med. 2014;119(7):521–32.CrossRefPubMedPubMedCentral
6.
go back to reference Bell BM Jr, Cura M, Shaw CJ, Rees CR. Transjugular intrahepatic portosystemic shunt creation using a three-dimensional fluoroscopy guidance system in patients with the Budd–Chiari syndrome. Proc (Bayl Univ Med Cent). 2015;28(4):484–7.CrossRef Bell BM Jr, Cura M, Shaw CJ, Rees CR. Transjugular intrahepatic portosystemic shunt creation using a three-dimensional fluoroscopy guidance system in patients with the Budd–Chiari syndrome. Proc (Bayl Univ Med Cent). 2015;28(4):484–7.CrossRef
7.
go back to reference Kalender WA, Kyriakou Y. Flat-detector computed tomography (FD-CT). Eur Radiol. 2007;17(11):2767–79.CrossRefPubMed Kalender WA, Kyriakou Y. Flat-detector computed tomography (FD-CT). Eur Radiol. 2007;17(11):2767–79.CrossRefPubMed
8.
go back to reference Bapst B, Lagadec M, Breguet R, Vilgrain V, Ronot M. Cone beam computed tomography (CBCT) in the field of interventional oncology of the liver. Cardiovasc Interv Radiol. 2016;39(1):8–20.CrossRef Bapst B, Lagadec M, Breguet R, Vilgrain V, Ronot M. Cone beam computed tomography (CBCT) in the field of interventional oncology of the liver. Cardiovasc Interv Radiol. 2016;39(1):8–20.CrossRef
10.
go back to reference Luo X, Wang X, Zhao Y, et al. Real-time 3D CT image guidance for transjugular intrahepatic portosystemic shunt creation using preoperative CT: a prospective feasibility study of 20 patients. AJR Am J Roentgenol. 2017;208(1):W11–6.CrossRefPubMed Luo X, Wang X, Zhao Y, et al. Real-time 3D CT image guidance for transjugular intrahepatic portosystemic shunt creation using preoperative CT: a prospective feasibility study of 20 patients. AJR Am J Roentgenol. 2017;208(1):W11–6.CrossRefPubMed
11.
go back to reference Rouabah K, Varoquaux A, Caporossi JM, et al. Image fusion-guided portal vein puncture during transjugular intrahepatic portosystemic shunt placement. Diagn Interv Imaging. 2016;97(11):1095–102.CrossRefPubMed Rouabah K, Varoquaux A, Caporossi JM, et al. Image fusion-guided portal vein puncture during transjugular intrahepatic portosystemic shunt placement. Diagn Interv Imaging. 2016;97(11):1095–102.CrossRefPubMed
12.
go back to reference Schulz B, Heidenreich R, Heidenreich M, et al. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications. Eur J Radiol. 2012;81(12):4138–42.CrossRefPubMed Schulz B, Heidenreich R, Heidenreich M, et al. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications. Eur J Radiol. 2012;81(12):4138–42.CrossRefPubMed
13.
go back to reference Kothary N, Abdelmaksoud MH, Tognolini A, et al. Imaging guidance with C-arm CT: prospective evaluation of its impact on patient radiation exposure during transhepatic arterial chemoembolization. J Vasc Interv Radiol. 2011;22(11):1535–43.CrossRefPubMed Kothary N, Abdelmaksoud MH, Tognolini A, et al. Imaging guidance with C-arm CT: prospective evaluation of its impact on patient radiation exposure during transhepatic arterial chemoembolization. J Vasc Interv Radiol. 2011;22(11):1535–43.CrossRefPubMed
14.
go back to reference Kim S, Yoshizumi TT, Frush DP, Toncheva G, Yin FF. Radiation dose from cone beam CT in a pediatric phantom: risk estimation of cancer incidence. AJR. 2010;194(1):186–90.CrossRefPubMed Kim S, Yoshizumi TT, Frush DP, Toncheva G, Yin FF. Radiation dose from cone beam CT in a pediatric phantom: risk estimation of cancer incidence. AJR. 2010;194(1):186–90.CrossRefPubMed
15.
go back to reference Pugmire BS, Shailam R, Sagar P, et al. Initial clinical experience with extremity cone-beam CT of the foot and ankle in pediatric patients. AJR. 2016;206(2):431–5.CrossRefPubMed Pugmire BS, Shailam R, Sagar P, et al. Initial clinical experience with extremity cone-beam CT of the foot and ankle in pediatric patients. AJR. 2016;206(2):431–5.CrossRefPubMed
16.
go back to reference Pellerin O, Lin M, Bhagat N, Shao W, Geschwind JF. Can C-arm cone-beam CT detect a micro-embolic effect after TheraSphere radioembolization of neuroendocrine and carcinoid liver metastasis? Cancer Biother Radiopharm. 2013;28(6):459–65.CrossRefPubMedPubMedCentral Pellerin O, Lin M, Bhagat N, Shao W, Geschwind JF. Can C-arm cone-beam CT detect a micro-embolic effect after TheraSphere radioembolization of neuroendocrine and carcinoid liver metastasis? Cancer Biother Radiopharm. 2013;28(6):459–65.CrossRefPubMedPubMedCentral
17.
go back to reference Loffroy R, Lin M, Yenokyan G, et al. Intraprocedural C-arm dual-phase cone-beam CT: can it be used to predict short-term response to TACE with drug-eluting beads in patients with hepatocellular carcinoma? Radiology. 2013;266(2):636–48.CrossRefPubMedPubMedCentral Loffroy R, Lin M, Yenokyan G, et al. Intraprocedural C-arm dual-phase cone-beam CT: can it be used to predict short-term response to TACE with drug-eluting beads in patients with hepatocellular carcinoma? Radiology. 2013;266(2):636–48.CrossRefPubMedPubMedCentral
18.
go back to reference Worm ES, Hoyer M, Fledelius W, Nielsen JE, Larsen LP, Poulsen PR. On-line use of three-dimensional marker trajectory estimation from cone-beam computed tomography projections for precise setup in radiotherapy for targets with respiratory motion. Int J Radiat Oncol Biol Phys. 2012;83(1):e145–51.CrossRefPubMed Worm ES, Hoyer M, Fledelius W, Nielsen JE, Larsen LP, Poulsen PR. On-line use of three-dimensional marker trajectory estimation from cone-beam computed tomography projections for precise setup in radiotherapy for targets with respiratory motion. Int J Radiat Oncol Biol Phys. 2012;83(1):e145–51.CrossRefPubMed
19.
go back to reference Kim MS, Singh S, Halpern E, Saini S, Kalra MK. Ablation margin assessment of liver tumors with intravenous contrast-enhanced C-arm computed tomography. World J Radiol. 2012;4(3):102–8.CrossRefPubMedPubMedCentral Kim MS, Singh S, Halpern E, Saini S, Kalra MK. Ablation margin assessment of liver tumors with intravenous contrast-enhanced C-arm computed tomography. World J Radiol. 2012;4(3):102–8.CrossRefPubMedPubMedCentral
20.
go back to reference Jonczyk M, Chapiro J, Collettini F, et al. Diagnostic accuracy of split-bolus single-phase contrast-enhanced cone-beam CT for the detection of liver tumors before transarterial chemoembolization. J Vasc Interv Radiol. 2017;28(10):1378–85.CrossRefPubMed Jonczyk M, Chapiro J, Collettini F, et al. Diagnostic accuracy of split-bolus single-phase contrast-enhanced cone-beam CT for the detection of liver tumors before transarterial chemoembolization. J Vasc Interv Radiol. 2017;28(10):1378–85.CrossRefPubMed
21.
go back to reference Raza SA, Walser E, Hernandez A, Chen K, Marroquin S. Transhepatic puncture of portal and hepatic veins for TIPS using a single-needle pass under sonographic guidance. AJR. 2006;187(1):W87–91.CrossRefPubMed Raza SA, Walser E, Hernandez A, Chen K, Marroquin S. Transhepatic puncture of portal and hepatic veins for TIPS using a single-needle pass under sonographic guidance. AJR. 2006;187(1):W87–91.CrossRefPubMed
22.
go back to reference Yang C, Wu P, Gong S, et al. Shading correction assisted iterative cone-beam CT reconstruction. Phys Med Biol. 2017;62(22):8495–520.CrossRefPubMed Yang C, Wu P, Gong S, et al. Shading correction assisted iterative cone-beam CT reconstruction. Phys Med Biol. 2017;62(22):8495–520.CrossRefPubMed
Metadata
Title
Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement
Authors
Georg Böning
Willie M. Lüdemann
Julius Chapiro
Martin Jonczyk
Bernd Hamm
Rolf W. Günther
Bernhard Gebauer
Florian Streitparth
Publication date
01-07-2018
Publisher
Springer US
Published in
CardioVascular and Interventional Radiology / Issue 7/2018
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-018-1877-4

Other articles of this Issue 7/2018

CardioVascular and Interventional Radiology 7/2018 Go to the issue