Skip to main content
Top
Published in: Pediatric Cardiology 6/2016

01-08-2016 | Original Article

Cerebral Microemboli Detection and Differentiation During Transcatheter Closure of Patent Ductus Arteriosus

Authors: Sean Wallace, Gaute Døhlen, Henrik Holmstrøm, Christian Lund, David Russell

Published in: Pediatric Cardiology | Issue 6/2016

Login to get access

Abstract

The aim of this prospective study was to determine the frequency and composition of cerebral microemboli in a pediatric population, during transcatheter closure of patent ductus arteriosus (PDA). Multifrequency transcranial Doppler was used to monitor cerebral blood flow velocity (CBFV) and detect microembolic signals (MES) in the middle cerebral artery in 23 patients (median age 18 months). MES were automatically identified and differentiated according to composition; gaseous or solid. The procedure was divided into five periods: Arterial catheterization; venous catheterization; ductal catheterization; angiography; device placement and release. Timing of catheter manipulations and MES were registered and compared. MES were detected in all patients. The median number of signals was 7, (minimum 1, maximum 28). Over 95 % of all MES were gaseous. 11 % were detected during device placement while 64 % were detected during angiographic studies, significantly higher than during any other period (P < 0.001). There was a moderate correlation between the number of MES and volume of contrast used, (R = 0.622, P < 0.01). There was no correlation with fluoroscopic time or duration of procedure. This is the first study to investigate the timing and composition of cerebral microemboli during PDA occlusion. Microemboli were related to specific catheter manipulations and correlated with the amount of contrast used.
Literature
1.
go back to reference Gournay V (2011) The ductus arteriosus: physiology, regulation, and functional and congenital anomalies. Arch Cardiovasc Dis 104(11):578–585CrossRefPubMed Gournay V (2011) The ductus arteriosus: physiology, regulation, and functional and congenital anomalies. Arch Cardiovasc Dis 104(11):578–585CrossRefPubMed
2.
go back to reference Park YA et al (2010) Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less. Korean J Pediatr 53(12):1012–1017CrossRefPubMedPubMedCentral Park YA et al (2010) Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less. Korean J Pediatr 53(12):1012–1017CrossRefPubMedPubMedCentral
3.
go back to reference Rao PS (2001) Summary and comparison of patent ductus arteriosus closure devices. Curr Interv Cardiol Rep 3(3):268–274PubMed Rao PS (2001) Summary and comparison of patent ductus arteriosus closure devices. Curr Interv Cardiol Rep 3(3):268–274PubMed
4.
go back to reference Masura J et al (2006) Long-term outcome of transcatheter patent ductus arteriosus closure using Amplatzer duct occluders. Am Heart J 151(3):755 e7–755 e10CrossRefPubMed Masura J et al (2006) Long-term outcome of transcatheter patent ductus arteriosus closure using Amplatzer duct occluders. Am Heart J 151(3):755 e7–755 e10CrossRefPubMed
5.
go back to reference Magee AG et al (2001) Transcatheter coil occlusion of the arterial duct; results of the European registry. Eur Heart J 22(19):1817–1821CrossRefPubMed Magee AG et al (2001) Transcatheter coil occlusion of the arterial duct; results of the European registry. Eur Heart J 22(19):1817–1821CrossRefPubMed
6.
go back to reference Hamon M et al (2012) Silent cerebral infarcts after cardiac catheterization: a randomized comparison of radial and femoral approaches. Am Heart J 164(4):449–454CrossRefPubMed Hamon M et al (2012) Silent cerebral infarcts after cardiac catheterization: a randomized comparison of radial and femoral approaches. Am Heart J 164(4):449–454CrossRefPubMed
7.
go back to reference Itoh S et al (2011) Microembolic signals measured by transcranial Doppler during transcatheter closure of atrial septal defect using the Amplatzer septal occluder. Cardiol Young 21(2):182–186CrossRefPubMed Itoh S et al (2011) Microembolic signals measured by transcranial Doppler during transcatheter closure of atrial septal defect using the Amplatzer septal occluder. Cardiol Young 21(2):182–186CrossRefPubMed
8.
go back to reference Wallace S et al (2015) Cerebral microemboli detection and differentiation during transcatheter closure of atrial septal defect in a paediatric population. Cardiol Young 25(2):237–244CrossRefPubMed Wallace S et al (2015) Cerebral microemboli detection and differentiation during transcatheter closure of atrial septal defect in a paediatric population. Cardiol Young 25(2):237–244CrossRefPubMed
9.
go back to reference Rodriguez RA et al (1999) Cerebral blood flow velocity during occlusive manipulation of patent ductus arteriosus in children. J Neuroimaging 9(1):23–29CrossRefPubMed Rodriguez RA et al (1999) Cerebral blood flow velocity during occlusive manipulation of patent ductus arteriosus in children. J Neuroimaging 9(1):23–29CrossRefPubMed
10.
go back to reference Bissonnette B, Benson LN (1998) Closure of persistently patent arterial duct and its impact on cerebral circulatory haemodynamics in children. Can J Anaesth 45(3):199–205CrossRefPubMed Bissonnette B, Benson LN (1998) Closure of persistently patent arterial duct and its impact on cerebral circulatory haemodynamics in children. Can J Anaesth 45(3):199–205CrossRefPubMed
11.
go back to reference Russell D, Brucher R (2002) Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler. Stroke 33(8):1975–1980CrossRefPubMed Russell D, Brucher R (2002) Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler. Stroke 33(8):1975–1980CrossRefPubMed
12.
go back to reference Brucher R, Russell D (2002) Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler. Stroke 33(8):1969–1974CrossRefPubMed Brucher R, Russell D (2002) Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler. Stroke 33(8):1969–1974CrossRefPubMed
13.
go back to reference Russell D, Brucher R (2005) Embolus detection and differentiation using multifrequency transcranial Doppler. Stroke 36(4):706CrossRefPubMed Russell D, Brucher R (2005) Embolus detection and differentiation using multifrequency transcranial Doppler. Stroke 36(4):706CrossRefPubMed
14.
go back to reference Lund C et al (2005) Cerebral emboli during left heart catheterization may cause acute brain injury. Eur Heart J 26(13):1269–1275CrossRefPubMed Lund C et al (2005) Cerebral emboli during left heart catheterization may cause acute brain injury. Eur Heart J 26(13):1269–1275CrossRefPubMed
15.
go back to reference Leclercq F et al (2001) Transcranial Doppler detection of cerebral microemboli during left heart catheterization. Cerebrovasc Dis 12(1):59–65CrossRefPubMed Leclercq F et al (2001) Transcranial Doppler detection of cerebral microemboli during left heart catheterization. Cerebrovasc Dis 12(1):59–65CrossRefPubMed
16.
go back to reference Bladin CF et al (1998) Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty. Stroke 29(11):2367–2370CrossRefPubMed Bladin CF et al (1998) Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty. Stroke 29(11):2367–2370CrossRefPubMed
17.
go back to reference Busing KA et al (2005) Cerebral infarction: incidence and risk factors after diagnostic and interventional cardiac catheterization–prospective evaluation at diffusion-weighted MR imaging. Radiology 235(1):177–183CrossRefPubMed Busing KA et al (2005) Cerebral infarction: incidence and risk factors after diagnostic and interventional cardiac catheterization–prospective evaluation at diffusion-weighted MR imaging. Radiology 235(1):177–183CrossRefPubMed
18.
go back to reference Francis E et al (2010) Transcatheter occlusion of patent ductus arteriosus in pre-term infants. JACC Cardiovasc Interv 3(5):550–555CrossRefPubMed Francis E et al (2010) Transcatheter occlusion of patent ductus arteriosus in pre-term infants. JACC Cardiovasc Interv 3(5):550–555CrossRefPubMed
19.
go back to reference Kumar RK et al (2004) Bioptome-assisted coil occlusion of moderate-large patent ductus arteriosus in infants and small children. Catheter Cardiovasc Interv 62(2):266–271CrossRefPubMed Kumar RK et al (2004) Bioptome-assisted coil occlusion of moderate-large patent ductus arteriosus in infants and small children. Catheter Cardiovasc Interv 62(2):266–271CrossRefPubMed
20.
go back to reference Ferrari J et al (2004) Cerebral microembolism during transcatheter closure of patent foramen ovale. J Neurol 251(7):825–829CrossRefPubMed Ferrari J et al (2004) Cerebral microembolism during transcatheter closure of patent foramen ovale. J Neurol 251(7):825–829CrossRefPubMed
21.
go back to reference Morandi E et al (2006) Silent brain embolism during transcatheter closure of patent foramen ovale: a transcranial Doppler study. Neurol Sci 27(5):328–331CrossRefPubMed Morandi E et al (2006) Silent brain embolism during transcatheter closure of patent foramen ovale: a transcranial Doppler study. Neurol Sci 27(5):328–331CrossRefPubMed
22.
go back to reference Braekken SK et al (1998) Influence of guidewire and catheter type on the frequency of cerebral microembolic signals during left heart catheterization. Am J Cardiol 82(5):632–637CrossRefPubMed Braekken SK et al (1998) Influence of guidewire and catheter type on the frequency of cerebral microembolic signals during left heart catheterization. Am J Cardiol 82(5):632–637CrossRefPubMed
23.
go back to reference Hamon M et al (2006) Cerebral microembolism during cardiac catheterization and risk of acute brain injury: a prospective diffusion-weighted magnetic resonance imaging study. Stroke 37(8):2035–2038CrossRefPubMed Hamon M et al (2006) Cerebral microembolism during cardiac catheterization and risk of acute brain injury: a prospective diffusion-weighted magnetic resonance imaging study. Stroke 37(8):2035–2038CrossRefPubMed
24.
go back to reference Scott DA et al (2014) Cognitive dysfunction follows left heart catheterisation but is not related to microembolic count. Int J Cardiol 175(1):67–71CrossRefPubMed Scott DA et al (2014) Cognitive dysfunction follows left heart catheterisation but is not related to microembolic count. Int J Cardiol 175(1):67–71CrossRefPubMed
25.
go back to reference Kruis RW, Vlasveld FA, Van Dijk D (2010) The (un)importance of cerebral microemboli. Semin Cardiothorac Vasc Anesth 14(2):111–118CrossRefPubMed Kruis RW, Vlasveld FA, Van Dijk D (2010) The (un)importance of cerebral microemboli. Semin Cardiothorac Vasc Anesth 14(2):111–118CrossRefPubMed
26.
go back to reference Lund C et al (2005) Cerebral ischemic injury and cognitive impairment after off-pump and on-pump coronary artery bypass grafting surgery. Ann Thorac Surg 80(6):2126–2131CrossRefPubMed Lund C et al (2005) Cerebral ischemic injury and cognitive impairment after off-pump and on-pump coronary artery bypass grafting surgery. Ann Thorac Surg 80(6):2126–2131CrossRefPubMed
27.
go back to reference Skjelland M et al (2009) Cerebral microemboli and brain injury during carotid artery endarterectomy and stenting. Stroke 40(1):230–234CrossRefPubMed Skjelland M et al (2009) Cerebral microemboli and brain injury during carotid artery endarterectomy and stenting. Stroke 40(1):230–234CrossRefPubMed
28.
go back to reference Banahan C et al (2014) An in vitro comparison of embolus differentiation techniques for clinically significant macroemboli: dual-frequency technique versus frequency modulation method. Ultrasound Med Biol 40(11):2642–2654CrossRefPubMedPubMedCentral Banahan C et al (2014) An in vitro comparison of embolus differentiation techniques for clinically significant macroemboli: dual-frequency technique versus frequency modulation method. Ultrasound Med Biol 40(11):2642–2654CrossRefPubMedPubMedCentral
29.
go back to reference Russell D, Brucher R (2006) Embolus detection and differentiation using multifrequency transcranial Doppler. Stroke 37(2):340–341CrossRefPubMed Russell D, Brucher R (2006) Embolus detection and differentiation using multifrequency transcranial Doppler. Stroke 37(2):340–341CrossRefPubMed
Metadata
Title
Cerebral Microemboli Detection and Differentiation During Transcatheter Closure of Patent Ductus Arteriosus
Authors
Sean Wallace
Gaute Døhlen
Henrik Holmstrøm
Christian Lund
David Russell
Publication date
01-08-2016
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 6/2016
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-016-1410-y

Other articles of this Issue 6/2016

Pediatric Cardiology 6/2016 Go to the issue