Abstract

Purpose

The cement augmentation of a conventional anterior screw fixation in type II odontoid process fractures for elderly patients significantly increased stiffness and load to failure under anterior–posterior load in comparison with non-augmented fixation. The amount and quality of bone cement are usually taken ad hoc in clinical practise. In this study, we wanted to clarify the role of bone cement amount and its quality to the stiffness of odontoid and vertebrae body junction.

Methods

Finite-element method was used to achieve different scenarios of cement augmentation. For all models, an initial stiffness was calculated. Model (1) the intact vertebrae were virtually potted into a polymethylmethacrylate base via the posterior vertebral arches. A V-shaped punch was used for loading the odontoid in an anterior–posterior direction. (2) The odontoid fracture type IIa (Anderson–D’Alonzo classification) was achieved by virtual transverse osteotomy. Anterior screw fixation was virtually performed by putting self-drilling titanium alloy 3.5 mm diameter anterior cannulated lag screw with a 12 mm thread into the inspected vertebrae. A V-shaped punch was used for loading the odontoid in an anterior–posterior direction. The vertebrae body was assumed to be non-cemented and cemented with different volume.

Results

The mean cement volume was lowest for body base filling with 0.47 ± 0.03 ml. The standard body filling corresponds to 0.95 ± 0.15 ml. The largest volume corresponds to 1.62 ± 0.12 ml in the presence of cement leakage. The initial stiffness of the intact C2 vertebrae was taken as the reference value. The mean initial stiffness for non-porous cement (E = 3000 MPa) increased linearly (R2 = 0.98). The lowest stiffness (123.3 ± 5.8 N/mm) was measured in the intact C2 vertebrae. However, the highest stiffness (165.2 ± 5.2 N/mm) was measured when cement leakage out of the odontoid peg occurred. The mean initial stiffness of the base-only cemented group was 147.2 ± 8.4 N/mm compared with 157.9 ± 6.6 N/mm for the base and body cemented group. This difference was statistically significant (p < 0.0061). The mean initial stiffness for porous cement (E = 500 MPa) remains constant. Therefore, there is no difference between cemented and non-cemented junction. This difference was not statistically significant (p < 0.18).

Conclusion

The present study showed that the low porous cement was able to significantly influence the stiffness of the augmented odontoid screw fixation in vitro, although further in vivo clinical studies should be undertaken. Our results suggest that only a small amount of non-porous cement is needed to restore stiffness at least to its pre-fracture level and this can be achieved with the injection of 0.7–1.2 ml of cement.

Graphic abstract

These slides can be retrieved under Electronic Supplementary Material.
Appendix
Available only for authorised users
Literature
1.
go back to reference Hide IG, Gangi A (2004) Percutaneous vertebroplasty: history, technique and current perspectives. Clin Radiol 59(6):461–467CrossRef Hide IG, Gangi A (2004) Percutaneous vertebroplasty: history, technique and current perspectives. Clin Radiol 59(6):461–467CrossRef
2.
go back to reference Liebschner MA, Rosenberg WS, Keaveny TM (2001) Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine (Phila Pa 1976) 26(14):1547–1554CrossRef Liebschner MA, Rosenberg WS, Keaveny TM (2001) Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine (Phila Pa 1976) 26(14):1547–1554CrossRef
3.
go back to reference Kohlhof H, Seidel U, Hoppe S, Keel MJ, Benneker LM (2013) Cement-augmented anterior screw fixation of Type II odontoid fractures in elderly patients with osteoporosis. Spine J 13(12):1858–1863CrossRef Kohlhof H, Seidel U, Hoppe S, Keel MJ, Benneker LM (2013) Cement-augmented anterior screw fixation of Type II odontoid fractures in elderly patients with osteoporosis. Spine J 13(12):1858–1863CrossRef
4.
go back to reference Waschke A, Berger-Roscher N, Kielstein H, Ewald C, Kalff R, Wilke HJ (2015) Cement augmented anterior odontoid screw fixation is biomechanically advantageous in osteoporotic patients with Anderson Type II fractures. J Spinal Disord Tech 28(3):E126–E132CrossRef Waschke A, Berger-Roscher N, Kielstein H, Ewald C, Kalff R, Wilke HJ (2015) Cement augmented anterior odontoid screw fixation is biomechanically advantageous in osteoporotic patients with Anderson Type II fractures. J Spinal Disord Tech 28(3):E126–E132CrossRef
5.
go back to reference Schmidt R, Cakir B, Mattes T, Wegener M, Puhl W, Richter M (2005) Cement leakage during vertebroplasty: an underestimated problem? Eur Spine J 14(5):466–473CrossRef Schmidt R, Cakir B, Mattes T, Wegener M, Puhl W, Richter M (2005) Cement leakage during vertebroplasty: an underestimated problem? Eur Spine J 14(5):466–473CrossRef
6.
go back to reference Hulme PA, Krebs J, Ferguson SJ, Berlemann U (2006) Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies. Spine (Phila Pa 1976) 31(17):1983–2001CrossRef Hulme PA, Krebs J, Ferguson SJ, Berlemann U (2006) Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies. Spine (Phila Pa 1976) 31(17):1983–2001CrossRef
7.
go back to reference Zhan Y, Jiang J, Liao H, Tan H, Yang K (2017) Risk factors for cement leakage after vertebroplasty or kyphoplasty: a meta-analysis of published evidence. World Neurosurg 101:633–642CrossRef Zhan Y, Jiang J, Liao H, Tan H, Yang K (2017) Risk factors for cement leakage after vertebroplasty or kyphoplasty: a meta-analysis of published evidence. World Neurosurg 101:633–642CrossRef
8.
go back to reference Nieuwenhuijse MJ, Van Erkel AR, Dijkstra PD (2011) Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors. Spine J 11(9):839–848CrossRef Nieuwenhuijse MJ, Van Erkel AR, Dijkstra PD (2011) Cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: identification of risk factors. Spine J 11(9):839–848CrossRef
9.
go back to reference Sun HB, Jing XS, Liu YZ, Qi M, Wang XK, Hai Y (2018) The optimal volume fraction in percutaneous vertebroplasty evaluated by pain relief, cement dispersion, and cement leakage: a prospective cohort study of 130 patients with painful osteoporotic vertebral compression fracture in the thoracolumbar vertebra. World Neurosurg 114:e677–e688CrossRef Sun HB, Jing XS, Liu YZ, Qi M, Wang XK, Hai Y (2018) The optimal volume fraction in percutaneous vertebroplasty evaluated by pain relief, cement dispersion, and cement leakage: a prospective cohort study of 130 patients with painful osteoporotic vertebral compression fracture in the thoracolumbar vertebra. World Neurosurg 114:e677–e688CrossRef
10.
go back to reference Yang EZ, Xu JG, Huang GZ, Xiao WZ, Liu XK, Zeng BF et al (2016) Percutaneous vertebroplasty versus conservative treatment in aged patients with acute osteoporotic vertebral compression fractures: a prospective randomized controlled clinical study. Spine (Phila Pa 1976) 41(8):653–660CrossRef Yang EZ, Xu JG, Huang GZ, Xiao WZ, Liu XK, Zeng BF et al (2016) Percutaneous vertebroplasty versus conservative treatment in aged patients with acute osteoporotic vertebral compression fractures: a prospective randomized controlled clinical study. Spine (Phila Pa 1976) 41(8):653–660CrossRef
11.
go back to reference Berlemann U, Ferguson SJ, Nolte LP, Heini PF (2002) Adjacent vertebral failure after vertebroplasty. A biomechanical investigation. J Bone Joint Surg Br 84(5):748–752CrossRef Berlemann U, Ferguson SJ, Nolte LP, Heini PF (2002) Adjacent vertebral failure after vertebroplasty. A biomechanical investigation. J Bone Joint Surg Br 84(5):748–752CrossRef
12.
go back to reference Boszczyk B (2010) Volume matters: a review of procedural details of two randomised controlled vertebroplasty trials of 2009. Eur Spine J 19(11):1837–1840CrossRef Boszczyk B (2010) Volume matters: a review of procedural details of two randomised controlled vertebroplasty trials of 2009. Eur Spine J 19(11):1837–1840CrossRef
13.
go back to reference Rehousek P, Jenner E, Holton J, Czyz M, Capek L, Henys P et al (2018) Biomechanical comparison of cemented versus non-cemented anterior screw fixation in type II odontoid fractures in the elderly: a cadaveric study. Spine J 18(10):1888–1895CrossRef Rehousek P, Jenner E, Holton J, Czyz M, Capek L, Henys P et al (2018) Biomechanical comparison of cemented versus non-cemented anterior screw fixation in type II odontoid fractures in the elderly: a cadaveric study. Spine J 18(10):1888–1895CrossRef
14.
go back to reference Goel VK, Nyman E (2016) Computational modeling and finite element analysis. Spine (Phila Pa 1976) 41(Suppl 7):S6–S7CrossRef Goel VK, Nyman E (2016) Computational modeling and finite element analysis. Spine (Phila Pa 1976) 41(Suppl 7):S6–S7CrossRef
15.
go back to reference Rohlmann A, Burra NK, Zander T, Bergmann G (2007) Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Eur Spine J 16(8):1223–1231CrossRef Rohlmann A, Burra NK, Zander T, Bergmann G (2007) Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Eur Spine J 16(8):1223–1231CrossRef
16.
go back to reference Morgan EF, Bayraktar HH, Keaveny TM (2003) Trabecular bone modulus-density relationships depend on anatomic site. J Biomech 36(7):897–904CrossRef Morgan EF, Bayraktar HH, Keaveny TM (2003) Trabecular bone modulus-density relationships depend on anatomic site. J Biomech 36(7):897–904CrossRef
17.
go back to reference Pauchard Y, Fitze T, Browarnik D, Eskandari A, Enns-Bray W, Pálsson H, Sigurdsson S, Ferguson Stephen J, Harris Tamara B, Gudnason V, Helgason B (2016) Interactive graph-cut segmentation for fast creation of finite element models from clinical CT data for hip fracture prediction. Comput Methods Biomech Biomed Eng 19(16):1693–1703CrossRef Pauchard Y, Fitze T, Browarnik D, Eskandari A, Enns-Bray W, Pálsson H, Sigurdsson S, Ferguson Stephen J, Harris Tamara B, Gudnason V, Helgason B (2016) Interactive graph-cut segmentation for fast creation of finite element models from clinical CT data for hip fracture prediction. Comput Methods Biomech Biomed Eng 19(16):1693–1703CrossRef
18.
go back to reference Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC et al (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31(3):1116–1128CrossRef Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC et al (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31(3):1116–1128CrossRef
19.
go back to reference Pal D, Sell P, Grevitt M (2011) Type II odontoid fractures in the elderly: an evidence-based narrative review of management. Eur Spine J 20(2):195–204CrossRef Pal D, Sell P, Grevitt M (2011) Type II odontoid fractures in the elderly: an evidence-based narrative review of management. Eur Spine J 20(2):195–204CrossRef
20.
go back to reference Löhrer L, Raschke MJ, Thiesen D, Hartensuer R, Surke C, Ochman S et al (2012) Current concepts in the treatment of Anderson type II odontoid fractures in the elderly in Germany, Austria and Switzerland. Injury 43(4):462–469CrossRef Löhrer L, Raschke MJ, Thiesen D, Hartensuer R, Surke C, Ochman S et al (2012) Current concepts in the treatment of Anderson type II odontoid fractures in the elderly in Germany, Austria and Switzerland. Injury 43(4):462–469CrossRef
21.
go back to reference Daniels AH, Magee W, Badra M, Bay B, Hettwer W, Hart RA (2012) Preliminary biomechanical proof of concept for a hybrid locking plate/variable pitch screw construct for anterior fixation of type II odontoid fractures. Spine (Phila Pa 1976) 37(19):E1159–E1164CrossRef Daniels AH, Magee W, Badra M, Bay B, Hettwer W, Hart RA (2012) Preliminary biomechanical proof of concept for a hybrid locking plate/variable pitch screw construct for anterior fixation of type II odontoid fractures. Spine (Phila Pa 1976) 37(19):E1159–E1164CrossRef
22.
go back to reference Belkoff SM, Mathis JM, Jasper LE, Deramond H (2001) The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior. Spine (Phila Pa 1976) 26(14):1537–1541CrossRef Belkoff SM, Mathis JM, Jasper LE, Deramond H (2001) The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior. Spine (Phila Pa 1976) 26(14):1537–1541CrossRef
23.
go back to reference Luo J, Daines L, Charalambous A, Adams MA, Annesley-Williams DJ, Dolan P (2009) Vertebroplasty: only small cement volumes are required to normalize stress distributions on the vertebral bodies. Spine (Phila Pa 1976) 34(26):2865–2873CrossRef Luo J, Daines L, Charalambous A, Adams MA, Annesley-Williams DJ, Dolan P (2009) Vertebroplasty: only small cement volumes are required to normalize stress distributions on the vertebral bodies. Spine (Phila Pa 1976) 34(26):2865–2873CrossRef
24.
go back to reference Lador R, Dreiangel N, Ben-Galim PJ, Hipp JA (2010) A pictorial classification atlas of cement extravasation with vertebral augmentation. Spine J 10(12):1118–1127CrossRef Lador R, Dreiangel N, Ben-Galim PJ, Hipp JA (2010) A pictorial classification atlas of cement extravasation with vertebral augmentation. Spine J 10(12):1118–1127CrossRef
25.
go back to reference Belkoff SM, Molloy S (2003) Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine (Phila Pa 1976) 28(14):1555–1559 Belkoff SM, Molloy S (2003) Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty. Spine (Phila Pa 1976) 28(14):1555–1559
26.
go back to reference Teo JCM, Teoh SH (2012) Permeability study of vertebral cancellous bone using micro- computational fluid dynamics. Comput Methods Biomech Biomed Eng 15:417–423CrossRef Teo JCM, Teoh SH (2012) Permeability study of vertebral cancellous bone using micro- computational fluid dynamics. Comput Methods Biomech Biomed Eng 15:417–423CrossRef
27.
go back to reference Kurutza M, Vargab P, Jakab G (2019) Prophylactic vertebroplasty versus kyphoplasty in osteoporosis: A comprehensive biomechanical matched-pair study by in vitro compressive testing. Med Eng Phys 65:45–46 Kurutza M, Vargab P, Jakab G (2019) Prophylactic vertebroplasty versus kyphoplasty in osteoporosis: A comprehensive biomechanical matched-pair study by in vitro compressive testing. Med Eng Phys 65:45–46
Metadata
Title
Cement augmentation of odontoid peg fractures: the effect of cement volume and distribution on construct stiffness
Authors
Lukas Capek
Petr Rehousek
Petr Henys
Sabri Bleibleh
Edward Jenner
Marketa Kulvajtova
Jiri Skala-Rosenbaum
Publication date
01-05-2020
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 5/2020
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-019-06286-6

Other articles of this Issue 5/2020

European Spine Journal 5/2020 Go to the issue

Announcements

Announcements