Skip to main content
Top
Published in: European Spine Journal 5/2020

01-05-2020 | Original Article

C1–C2 posterior screw fixation in atlantoaxial fractures revisited: technical update based on 127 cases

Authors: Niels Buchmann, Claudia Schweizer, Jan S. Kirschke, Anna Rienmüller, Jens Gempt, Florian Ringel, Bernhard Meyer, Yu- Mi Ryang

Published in: European Spine Journal | Issue 5/2020

Login to get access

Abstract

Introduction

Posterior fusion of traumatic odontoid fractures by C1 lateral mass and C2 isthmic screws (modified Harms–Goel technique) is a viable alternative to transarticular screw fixation due to its universal applicability. This retrospective study reports on a series of 127 patients.

Material and methods

Our clinical database was screened for patients with fractures of the upper cervical spine incorporating a C2 fracture, operated on between 2007 and 2015. Patients were included if fused by internal fixation via C1 lateral mass screws, C2 isthmic screws in freehand technique under lateral fluoroscopy. Screw placement was controlled postoperatively by computed tomography and rated using the Gertzbein & Robbins classification. Surgery-related complications, consecutive treatment, revision surgeries and duration of surgeries were registered.

Results

In total, 127 patients were identified with altogether 572 screws. Correct screw positions of grade A and B according to Gertzbein & Robbins were achieved in a total of 539 (94.2%) screws (grade A: 453 (79.2%); grade B: 86 (15%)), grade C screw malpositions noted in 21 (3.7%), grade D in 10 (1.7%) and grade E in 2 (0.3%) screws. Vertebral artery canal breaches occurred in 29 screws (5.1%), with vertebral artery occlusion in 4 patients. Coiling of injured vertebral artery had to be performed in one patient. None of these patients suffered clinically apparent cerebrovascular complications. Revision surgery was performed in 8 patients (6%).

Conclusion

Posterior fixation of atlantoaxial fractures by C1 lateral mass and C2 isthmic screws with fluoroscopy without navigation is a safe and feasible method but not free of risk of vertebral artery injuries.

Graphic abstract

These slides can be retrieved under Electronic Supplementary Material.
Appendix
Available only for authorised users
Literature
4.
go back to reference Vaccaro AR, Kepler CK, Kopjar B, Chapman J, Shaffrey C, Arnold P, Gokaslan Z, Brodke D, France J, Dekutoski M, Sasso R, Yoon ST, Bono C, Harrop J, Fehlings MG (2013) Functional and quality-of-life outcomes in geriatric patients with type-II dens fracture. J Bone Joint Surg Am 95(8):729–735. https://doi.org/10.2106/JBJS.K.01636 CrossRefPubMed Vaccaro AR, Kepler CK, Kopjar B, Chapman J, Shaffrey C, Arnold P, Gokaslan Z, Brodke D, France J, Dekutoski M, Sasso R, Yoon ST, Bono C, Harrop J, Fehlings MG (2013) Functional and quality-of-life outcomes in geriatric patients with type-II dens fracture. J Bone Joint Surg Am 95(8):729–735. https://​doi.​org/​10.​2106/​JBJS.​K.​01636 CrossRefPubMed
7.
go back to reference Jeanneret B, Magerl F (1992) Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord 5(4):464–475CrossRefPubMed Jeanneret B, Magerl F (1992) Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord 5(4):464–475CrossRefPubMed
8.
go back to reference Magerl F, Seemann P-S (1987) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Cervical spine I. Springer, pp 322–327 Magerl F, Seemann P-S (1987) Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Cervical spine I. Springer, pp 322–327
11.
go back to reference Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129(1–2):47–53CrossRef Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129(1–2):47–53CrossRef
12.
go back to reference Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51(6):1351–1356CrossRefPubMed Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51(6):1351–1356CrossRefPubMed
13.
go back to reference Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine 26(22):2467–2471CrossRefPubMed Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine 26(22):2467–2471CrossRefPubMed
14.
go back to reference Madawi A, Solanki G, Casey AT, Crockard HA (1997) Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation. J Bone Joint Surg Br 79(5):820–823CrossRefPubMed Madawi A, Solanki G, Casey AT, Crockard HA (1997) Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation. J Bone Joint Surg Br 79(5):820–823CrossRefPubMed
16.
go back to reference Wright NM, Lauryssen C (1998) Vertebral artery injury in C1–2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. J Neurosurg 88(4):634–640CrossRefPubMed Wright NM, Lauryssen C (1998) Vertebral artery injury in C1–2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. J Neurosurg 88(4):634–640CrossRefPubMed
27.
go back to reference Nitising A, Jetjumnong C, Tisavipat N, Nantaaree S (2011) Posterior C1–C2 fusion using C1 lateral mass and C2 pars screw with rod fixation: techniques and outcomes. J Med Assoc Thai 94(7):794–800PubMed Nitising A, Jetjumnong C, Tisavipat N, Nantaaree S (2011) Posterior C1–C2 fusion using C1 lateral mass and C2 pars screw with rod fixation: techniques and outcomes. J Med Assoc Thai 94(7):794–800PubMed
Metadata
Title
C1–C2 posterior screw fixation in atlantoaxial fractures revisited: technical update based on 127 cases
Authors
Niels Buchmann
Claudia Schweizer
Jan S. Kirschke
Anna Rienmüller
Jens Gempt
Florian Ringel
Bernhard Meyer
Yu- Mi Ryang
Publication date
01-05-2020
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 5/2020
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-019-06244-2

Other articles of this Issue 5/2020

European Spine Journal 5/2020 Go to the issue