Cardiac output monitoring: an integrative perspective

Authors: Jamal A Alhashemi, Maurizio Cecconi, Christoph K Hofer

Published in: Critical Care | Issue 2/2011

Login to get access

Excerpt

Cardiac output monitoring in the critically ill patient is standard practice in order to ensure tissue oxygenation [1] and has been traditionally accomplished using the pulmonary artery catheter (PAC). In recent years, however, the value of PAC has been questioned with some suggesting that its use might not only be unnecessary but also potentially harmful [1]. This notion, together with the availability of new less invasive cardiac output measuring devices, has markedly decreased the widespread use of the PAC [2]. Today, various devices are available to measure or estimate cardiac output using different methods. Some of these less invasive devices track stroke volume (SV) continuously and provide dynamic indices of fluid responsiveness, others allow assessment of volumetric preload variables, and some also provide continuous measurement of central venous saturation via the use of proprietary catheters that are attached to the same monitor. All these variables - together with cardiac output - may result in an improved hemodynamic assessment of the critically ill patient. However, it is important to appreciate that each device has its inherent limitations and that no cardiac output monitoring device can change patient outcome unless its use is coupled with an intervention that by itself has been associated with improved patient outcomes. Therefore, the concept of hemodynamic optimization is increasingly recognized as a cornerstone in the management of critically ill patients and has been shown to be associated with improved outcome in the perioperative [3] and in the intensive care unit (ICU) [4] setting. …
Literature
1.
go back to reference Connors AF Jr, Speroff T, Dawson NV, et al.: The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 1996, 276: 889-897. 10.1001/jama.276.11.889CrossRefPubMed Connors AF Jr, Speroff T, Dawson NV, et al.: The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 1996, 276: 889-897. 10.1001/jama.276.11.889CrossRefPubMed
2.
go back to reference Harvey S, Stevens K, Harrison D, et al.: An evaluation of the clinical and cost-effectiveness of pulmonary artery catheters in patient management in intensive care: a systematic review and a randomised controlled trial. Health Technol Assess 2006, 10: 1-133.CrossRef Harvey S, Stevens K, Harrison D, et al.: An evaluation of the clinical and cost-effectiveness of pulmonary artery catheters in patient management in intensive care: a systematic review and a randomised controlled trial. Health Technol Assess 2006, 10: 1-133.CrossRef
4.
go back to reference Funk D, Sebat F, Kumar A: A systems approach to the early recognition and rapid administration of best practice therapy in sepsis and septic shock. Curr Opin Crit Care 2009, 15: 301-307. 10.1097/MCC.0b013e32832e3825CrossRefPubMed Funk D, Sebat F, Kumar A: A systems approach to the early recognition and rapid administration of best practice therapy in sepsis and septic shock. Curr Opin Crit Care 2009, 15: 301-307. 10.1097/MCC.0b013e32832e3825CrossRefPubMed
5.
go back to reference Harvey S, Harrison DA, Singer M, et al.: Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 2005, 366: 472-477. 10.1016/S0140-6736(05)67061-4CrossRefPubMed Harvey S, Harrison DA, Singer M, et al.: Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 2005, 366: 472-477. 10.1016/S0140-6736(05)67061-4CrossRefPubMed
6.
go back to reference Nishikawa T, Dohi S: Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993, 40: 142-153. 10.1007/BF03011312CrossRefPubMed Nishikawa T, Dohi S: Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993, 40: 142-153. 10.1007/BF03011312CrossRefPubMed
7.
go back to reference Aranda M, Mihm FG, Garrett S, Mihm MN, Pearl RG: Continuous cardiac output catheters: delay in in vitro response time after controlled flow changes. Anesthesiology 1998, 89: 1592-1595. 10.1097/00000542-199812000-00047CrossRefPubMed Aranda M, Mihm FG, Garrett S, Mihm MN, Pearl RG: Continuous cardiac output catheters: delay in in vitro response time after controlled flow changes. Anesthesiology 1998, 89: 1592-1595. 10.1097/00000542-199812000-00047CrossRefPubMed
8.
go back to reference Leather HA, Vuylsteke A, Bert C, et al.: Evaluation of a new continuous cardiac output monitor in off-pump coronary artery surgery. Anaesthesia 2004, 59: 385-389. 10.1111/j.1365-2044.2004.03668.xCrossRefPubMed Leather HA, Vuylsteke A, Bert C, et al.: Evaluation of a new continuous cardiac output monitor in off-pump coronary artery surgery. Anaesthesia 2004, 59: 385-389. 10.1111/j.1365-2044.2004.03668.xCrossRefPubMed
9.
go back to reference Hamzaoui O, Monnet X, Richard C, et al.: Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Crit Care Med 2008, 36: 434-440. 10.1097/01.CCM.OB013E318161FEC4CrossRefPubMed Hamzaoui O, Monnet X, Richard C, et al.: Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period. Crit Care Med 2008, 36: 434-440. 10.1097/01.CCM.OB013E318161FEC4CrossRefPubMed
10.
go back to reference Button D, Weibel L, Reuthebuch O, et al.: Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. Br J Anaesth 2007, 99: 329-336. 10.1093/bja/aem188CrossRefPubMed Button D, Weibel L, Reuthebuch O, et al.: Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. Br J Anaesth 2007, 99: 329-336. 10.1093/bja/aem188CrossRefPubMed
11.
go back to reference Della Rocca G, Costa MG, Coccia C, et al.: Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation. Can J Anaesth 2003, 50: 707-711. 10.1007/BF03018714CrossRefPubMed Della Rocca G, Costa MG, Coccia C, et al.: Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation. Can J Anaesth 2003, 50: 707-711. 10.1007/BF03018714CrossRefPubMed
12.
go back to reference Cecconi M, Fawcett J, Grounds RM, Rhodes A: A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients. BMC Anesthesiol 2008, 8: 3. 10.1186/1471-2253-8-3PubMedCentralCrossRefPubMed Cecconi M, Fawcett J, Grounds RM, Rhodes A: A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients. BMC Anesthesiol 2008, 8: 3. 10.1186/1471-2253-8-3PubMedCentralCrossRefPubMed
13.
go back to reference Cecconi M, Dawson D, Grounds RM, Rhodes A: Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique. Intensive Care Med 2009, 35: 498-504. 10.1007/s00134-008-1292-4CrossRefPubMed Cecconi M, Dawson D, Grounds RM, Rhodes A: Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique. Intensive Care Med 2009, 35: 498-504. 10.1007/s00134-008-1292-4CrossRefPubMed
14.
go back to reference Pearse R, Dawson D, Fawcett J, Rhodes A, Grounds RM, Bennett ED: Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care 2005, 9: R687-R693. 10.1186/cc3887PubMedCentralCrossRefPubMed Pearse R, Dawson D, Fawcett J, Rhodes A, Grounds RM, Bennett ED: Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care 2005, 9: R687-R693. 10.1186/cc3887PubMedCentralCrossRefPubMed
15.
go back to reference Mayer J, Boldt J, Poland R, Peterson A, Manecke GR Jr: Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis. J Cardiothorac Vasc Anesth 2009, 23: 401-406. 10.1053/j.jvca.2009.03.003CrossRefPubMed Mayer J, Boldt J, Poland R, Peterson A, Manecke GR Jr: Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis. J Cardiothorac Vasc Anesth 2009, 23: 401-406. 10.1053/j.jvca.2009.03.003CrossRefPubMed
16.
go back to reference Senn A, Button D, Zollinger A, Hofer CK: Assessment of cardiac output changes using a modified FloTrac/Vigileo algorithm in cardiac surgery patients. Crit Care 2009, 13: R32. 10.1186/cc7739PubMedCentralCrossRefPubMed Senn A, Button D, Zollinger A, Hofer CK: Assessment of cardiac output changes using a modified FloTrac/Vigileo algorithm in cardiac surgery patients. Crit Care 2009, 13: R32. 10.1186/cc7739PubMedCentralCrossRefPubMed
18.
go back to reference Mayer J, Boldt J, Mengistu AM, Rohm KD, Suttner S: Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial. Crit Care 2010, 14: R18. 10.1186/cc8875PubMedCentralCrossRefPubMed Mayer J, Boldt J, Mengistu AM, Rohm KD, Suttner S: Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial. Crit Care 2010, 14: R18. 10.1186/cc8875PubMedCentralCrossRefPubMed
19.
go back to reference Scolletta S, Romano SM, Biagioli B, Capannini G, Giomarelli P: Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states. Br J Anaesth 2005, 95: 159-165. 10.1093/bja/aei154CrossRefPubMed Scolletta S, Romano SM, Biagioli B, Capannini G, Giomarelli P: Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states. Br J Anaesth 2005, 95: 159-165. 10.1093/bja/aei154CrossRefPubMed
20.
go back to reference Giomarelli P, Biagioli B, Scolletta S: Cardiac output monitoring by pressure recording analytical method in cardiac surgery. Eur J Cardiothorac Surg 2004, 26: 515-520. 10.1016/j.ejcts.2004.05.025CrossRefPubMed Giomarelli P, Biagioli B, Scolletta S: Cardiac output monitoring by pressure recording analytical method in cardiac surgery. Eur J Cardiothorac Surg 2004, 26: 515-520. 10.1016/j.ejcts.2004.05.025CrossRefPubMed
21.
go back to reference Stover JF, Stocker R, Lenherr R, et al.: Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients. BMC Anesthesiol 2009, 9: 6. 10.1186/1471-2253-9-6PubMedCentralCrossRefPubMed Stover JF, Stocker R, Lenherr R, et al.: Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients. BMC Anesthesiol 2009, 9: 6. 10.1186/1471-2253-9-6PubMedCentralCrossRefPubMed
22.
go back to reference Lefrant JY, Bruelle P, Aya AG, et al.: Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 1998, 24: 347-352. 10.1007/s001340050578CrossRefPubMed Lefrant JY, Bruelle P, Aya AG, et al.: Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 1998, 24: 347-352. 10.1007/s001340050578CrossRefPubMed
23.
go back to reference Valtier B, Cholley BP, Belot JP, et al.: Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Respir Crit Care Med 1998, 158: 77-83.CrossRefPubMed Valtier B, Cholley BP, Belot JP, et al.: Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Respir Crit Care Med 1998, 158: 77-83.CrossRefPubMed
24.
go back to reference Abbas SM, Hill AG: Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery. Anaesthesia 2008, 63: 44-51. 10.1111/j.1365-2044.2007.05233.xCrossRefPubMed Abbas SM, Hill AG: Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery. Anaesthesia 2008, 63: 44-51. 10.1111/j.1365-2044.2007.05233.xCrossRefPubMed
25.
go back to reference Chan JS, Segara D, Nair P: Measurement of cardiac output with a non-invasive continuous wave Doppler device versus the pulmonary artery catheter: a comparative study. Crit Care Resusc 2006, 8: 309-314.PubMed Chan JS, Segara D, Nair P: Measurement of cardiac output with a non-invasive continuous wave Doppler device versus the pulmonary artery catheter: a comparative study. Crit Care Resusc 2006, 8: 309-314.PubMed
26.
go back to reference Thom O, Taylor DM, Wolfe RE, et al.: Comparison of a supra-sternal cardiac output monitor (USCOM) with the pulmonary artery catheter. Br J Anaesth 2009, 103: 800-804. 10.1093/bja/aep296CrossRefPubMed Thom O, Taylor DM, Wolfe RE, et al.: Comparison of a supra-sternal cardiac output monitor (USCOM) with the pulmonary artery catheter. Br J Anaesth 2009, 103: 800-804. 10.1093/bja/aep296CrossRefPubMed
27.
go back to reference Gueret G, Kiss G, Rossignol B, et al.: Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter. Eur J Anaesthesiol 2006, 23: 848-854. 10.1017/S0265021506000573CrossRefPubMed Gueret G, Kiss G, Rossignol B, et al.: Cardiac output measurements in off-pump coronary surgery: comparison between NICO and the Swan-Ganz catheter. Eur J Anaesthesiol 2006, 23: 848-854. 10.1017/S0265021506000573CrossRefPubMed
28.
go back to reference Tachibana K, Imanaka H, Takeuchi M, Takauchi Y, Miyano H, Nishimura M: Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present. Anesthesiology 2003, 98: 830-837. 10.1097/00000542-200304000-00007CrossRefPubMed Tachibana K, Imanaka H, Takeuchi M, Takauchi Y, Miyano H, Nishimura M: Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present. Anesthesiology 2003, 98: 830-837. 10.1097/00000542-200304000-00007CrossRefPubMed
29.
go back to reference Hofer CK, Buhlmann S, Klaghofer R, Genoni M, Zollinger A: Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique. Acta Anaesthesiol Scand 2004, 48: 653-657. 10.1111/j.1399-6576.2004.00371.xCrossRefPubMed Hofer CK, Buhlmann S, Klaghofer R, Genoni M, Zollinger A: Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique. Acta Anaesthesiol Scand 2004, 48: 653-657. 10.1111/j.1399-6576.2004.00371.xCrossRefPubMed
30.
go back to reference Ball TR, Culp BC, Patel V, et al.: Comparison of the endotracheal cardiac output monitor to thermodilution in cardiac surgery patients. J Cardiothorac Vasc 2010, 24: 762-766. 10.1053/j.jvca.2010.04.008CrossRef Ball TR, Culp BC, Patel V, et al.: Comparison of the endotracheal cardiac output monitor to thermodilution in cardiac surgery patients. J Cardiothorac Vasc 2010, 24: 762-766. 10.1053/j.jvca.2010.04.008CrossRef
31.
go back to reference Gujjar AR, Muralidhar K, Banakal S, et al.: Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: comparison with thermodilution method. J Clin Monit Comput 2008, 22: 175-180. 10.1007/s10877-008-9119-yCrossRefPubMed Gujjar AR, Muralidhar K, Banakal S, et al.: Non-invasive cardiac output by transthoracic electrical bioimpedence in post-cardiac surgery patients: comparison with thermodilution method. J Clin Monit Comput 2008, 22: 175-180. 10.1007/s10877-008-9119-yCrossRefPubMed
32.
go back to reference Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C: Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 2007, 33: 1191-1194. 10.1007/s00134-007-0640-0CrossRefPubMed Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C: Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 2007, 33: 1191-1194. 10.1007/s00134-007-0640-0CrossRefPubMed
33.
go back to reference Raval NY, Squara P, Cleman M, Yalamanchili K, Winklmaier M, Burkhoff D: Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput 2008, 22: 113-119. 10.1007/s10877-008-9112-5CrossRefPubMed Raval NY, Squara P, Cleman M, Yalamanchili K, Winklmaier M, Burkhoff D: Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput 2008, 22: 113-119. 10.1007/s10877-008-9112-5CrossRefPubMed
34.
go back to reference Boldt J, Lenz M, Kumle B, Papsdorf M: Volume replacement strategies on intensive care units: results from a postal survey. Intensive Care Med 1998, 24: 147-151. 10.1007/s001340050536CrossRefPubMed Boldt J, Lenz M, Kumle B, Papsdorf M: Volume replacement strategies on intensive care units: results from a postal survey. Intensive Care Med 1998, 24: 147-151. 10.1007/s001340050536CrossRefPubMed
35.
go back to reference Hofer CK, Furrer L, Matter-Ensner S, et al.: Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth 2005, 94: 748-755. 10.1093/bja/aei123CrossRefPubMed Hofer CK, Furrer L, Matter-Ensner S, et al.: Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth 2005, 94: 748-755. 10.1093/bja/aei123CrossRefPubMed
36.
go back to reference Kumar A, Anel R, Bunnell E, et al.: Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004, 32: 691-699. 10.1097/01.CCM.0000114996.68110.C9CrossRefPubMed Kumar A, Anel R, Bunnell E, et al.: Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004, 32: 691-699. 10.1097/01.CCM.0000114996.68110.C9CrossRefPubMed
37.
go back to reference Goepfert MS, Reuter DA, Akyol D, et al.: Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med 2007, 33: 96-103. 10.1007/s00134-006-0404-2CrossRefPubMed Goepfert MS, Reuter DA, Akyol D, et al.: Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med 2007, 33: 96-103. 10.1007/s00134-006-0404-2CrossRefPubMed
38.
go back to reference Sakka SG, Klein M, Reinhart K, Meier-Hellmann A: Prognostic value of extravascular lung water in critically ill patients. Chest 2002, 122: 2080-2086. 10.1378/chest.122.6.2080CrossRefPubMed Sakka SG, Klein M, Reinhart K, Meier-Hellmann A: Prognostic value of extravascular lung water in critically ill patients. Chest 2002, 122: 2080-2086. 10.1378/chest.122.6.2080CrossRefPubMed
39.
go back to reference Marik PE, Cavallazzi R, Vasu T, Hirani A: Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009, 37: 2642-2647. 10.1097/CCM.0b013e3181a590daCrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A: Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009, 37: 2642-2647. 10.1097/CCM.0b013e3181a590daCrossRefPubMed
40.
go back to reference Marik PE, Baram M, Vahid B: Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008, 134: 172-178. 10.1378/chest.07-2331CrossRefPubMed Marik PE, Baram M, Vahid B: Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008, 134: 172-178. 10.1378/chest.07-2331CrossRefPubMed
41.
go back to reference Monnet X, Teboul JL: Passive leg raising. Intensive Care Med 2008, 34: 659-663. 10.1007/s00134-008-0994-yCrossRefPubMed Monnet X, Teboul JL: Passive leg raising. Intensive Care Med 2008, 34: 659-663. 10.1007/s00134-008-0994-yCrossRefPubMed
42.
go back to reference Marx G, Reinhart K: Venous oximetry. Curr Opin Crit Care 2006, 12: 263-268. 10.1097/01.ccx.0000224872.09077.dcCrossRefPubMed Marx G, Reinhart K: Venous oximetry. Curr Opin Crit Care 2006, 12: 263-268. 10.1097/01.ccx.0000224872.09077.dcCrossRefPubMed
43.
go back to reference Rivers E, Nguyen B, Havstad S, et al.: Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001, 345: 1368-1377. 10.1056/NEJMoa010307CrossRefPubMed Rivers E, Nguyen B, Havstad S, et al.: Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001, 345: 1368-1377. 10.1056/NEJMoa010307CrossRefPubMed
44.
go back to reference Dueck MH, Klimek M, Appenrodt S, Weigand C, Boerner U: Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology 2005, 103: 249-257. 10.1097/00000542-200508000-00007CrossRefPubMed Dueck MH, Klimek M, Appenrodt S, Weigand C, Boerner U: Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology 2005, 103: 249-257. 10.1097/00000542-200508000-00007CrossRefPubMed
Metadata
Title
Cardiac output monitoring: an integrative perspective
Authors
Jamal A Alhashemi
Maurizio Cecconi
Christoph K Hofer
Publication date
01-04-2011
Publisher
BioMed Central
Published in
Critical Care / Issue 2/2011
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc9996

Other articles of this Issue 2/2011

Critical Care 2/2011 Go to the issue