01-04-2013 | Technological Advances in Cardiac Multi-modality Imaging (TH Schindler, Section Editor)

Cardiac Micro-PET-CT

Authors: Etienne Croteau, Jennifer M. Renaud, Robert A. deKemp

Published in: Current Cardiovascular Imaging Reports | Issue 2/2013

Login to get access

Abstract

Molecular imaging is a rapidly emerging field, with the use of multi-modality or hybrid technology scanners for in vivo investigations covering a broad spectrum of disease. Cardiac micro-PET-CT is one such promising multimodality. Standalone imaging technologies such as PET and CT have existed for several decades, however, they have only recently been utilized in concert, mainly for clinical cancer imaging. Cardiovascular events are responsible for nearly one-third of deaths in North America every year. Atherosclerosis, coronary artery disease (CAD), and heart failure are the most common types of heart disease. Cardiac imaging-related research into their prevention and treatment has contributed to a decrease in mortality. This review outlines the recent progress in the development and application of advanced cardiac micro-PET-CT technology. Current development of novel PET radiotracers focusing on diagnosis and characterization of different stages of atherosclerosis is discussed, as well as myocardial perfusion radiotracers mimicking previously established SPECT tracers and others. Small animal (mouse and rat) models of disease investigated with cardiac imaging are becoming more common, and will facilitate rapid translation to clinical studies with improvement in micro-PET-CT technology. Also, increasingly popular animal models for cardiovascular disease research such as mini-pigs and rabbits are used with interventional therapies, including catheterization due to larger artery sizes. The emergence of cardiac CT will be discussed with comparison between preclinical and clinical approaches, including consideration of radiation doses.
Literature
1.
go back to reference •• Sinusas AJ, Bengel F, Nahrendorf M, Epstein FH, Wu JC, Villanueva FS, et al. Multimodality cardiovascular molecular imaging, part I. Circ Cardiovasc Imaging. 2008;1:244–56. Comprehensive review of the instrumentation used in cardiac molecular imaging.PubMedCrossRef •• Sinusas AJ, Bengel F, Nahrendorf M, Epstein FH, Wu JC, Villanueva FS, et al. Multimodality cardiovascular molecular imaging, part I. Circ Cardiovasc Imaging. 2008;1:244–56. Comprehensive review of the instrumentation used in cardiac molecular imaging.PubMedCrossRef
2.
go back to reference • Halpern EJ. Clinical applications of cardiac CT angiography. Insights Imaging. 2010;1:205–22. Recent overview of CTA indications.PubMedCrossRef • Halpern EJ. Clinical applications of cardiac CT angiography. Insights Imaging. 2010;1:205–22. Recent overview of CTA indications.PubMedCrossRef
3.
go back to reference • Desai MY. Cardiac CT beyond coronary angiography: current and emerging non-coronary cardiac applications. Heart. 2011;97:417–24. Recent overview of non-CTA indications.PubMedCrossRef • Desai MY. Cardiac CT beyond coronary angiography: current and emerging non-coronary cardiac applications. Heart. 2011;97:417–24. Recent overview of non-CTA indications.PubMedCrossRef
4.
go back to reference Kramer CM, Sinusas AJ, Sosnovik DE, French BA, Bengel FM. Multimodality imaging of myocardial injury and remodeling. J Nucl Med. 2010;51:107S–21S.PubMedCrossRef Kramer CM, Sinusas AJ, Sosnovik DE, French BA, Bengel FM. Multimodality imaging of myocardial injury and remodeling. J Nucl Med. 2010;51:107S–21S.PubMedCrossRef
5.
go back to reference Ali B, Hsiao E, Di Carli MF. Combined anatomic and perfusion imaging of the heart. Curr Cardiol Rep. 2010;12:90–7.PubMedCrossRef Ali B, Hsiao E, Di Carli MF. Combined anatomic and perfusion imaging of the heart. Curr Cardiol Rep. 2010;12:90–7.PubMedCrossRef
6.
go back to reference Judenhofer MS, Wehrl HF, Newport DF, Catana C, Siegel SB, Becker M, et al. Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat Med. 2008;14:459–65.PubMedCrossRef Judenhofer MS, Wehrl HF, Newport DF, Catana C, Siegel SB, Becker M, et al. Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat Med. 2008;14:459–65.PubMedCrossRef
7.
go back to reference Nekolla SG, Martinez-Moeller A, Saraste A. PET and MRI in cardiac imaging: from validation studies to integrated applications. Eur J Nucl Med Mol Imaging. 2009;36:S121–30.PubMedCrossRef Nekolla SG, Martinez-Moeller A, Saraste A. PET and MRI in cardiac imaging: from validation studies to integrated applications. Eur J Nucl Med Mol Imaging. 2009;36:S121–30.PubMedCrossRef
8.
go back to reference Laitinen I, Saraste A, Weidl E, Poethko T, Weber AW, Nekolla SG, et al. Evaluation of alphavbeta3 integrin-targeted positron emission tomography tracer 18F-galacto-RGD for imaging of vascular inflammation in atherosclerotic mice. Circ Cardiovasc Imaging. 2009;2:331–8.PubMedCrossRef Laitinen I, Saraste A, Weidl E, Poethko T, Weber AW, Nekolla SG, et al. Evaluation of alphavbeta3 integrin-targeted positron emission tomography tracer 18F-galacto-RGD for imaging of vascular inflammation in atherosclerotic mice. Circ Cardiovasc Imaging. 2009;2:331–8.PubMedCrossRef
9.
go back to reference Nahrendorf M, Keliher E, Panizzi P, Zhang H, Hembrador S, Figueiredo JL, et al. 18F-4V for PET-CT imaging of VCAM-1 expression in atherosclerosis. Jacc: Cardiovasc Imaging. 2009;2:1213–22.CrossRef Nahrendorf M, Keliher E, Panizzi P, Zhang H, Hembrador S, Figueiredo JL, et al. 18F-4V for PET-CT imaging of VCAM-1 expression in atherosclerosis. Jacc: Cardiovasc Imaging. 2009;2:1213–22.CrossRef
10.
go back to reference Liu Y, Abendschein D, Woodard GE, Rossin R, McCommis K, Zheng J, et al. Molecular imaging of atherosclerotic plaque with (64)cu-labeled natriuretic peptide and PET. J Nucl Med. 2010;51:85–91.PubMedCrossRef Liu Y, Abendschein D, Woodard GE, Rossin R, McCommis K, Zheng J, et al. Molecular imaging of atherosclerotic plaque with (64)cu-labeled natriuretic peptide and PET. J Nucl Med. 2010;51:85–91.PubMedCrossRef
11.
go back to reference Silvola JM, Saraste A, Forsback S, Laine VJ, Saukko P, Heinonen SE, et al. Detection of hypoxia by [18F]EF5 in atherosclerotic plaques in mice. Arterioscler Thromb Vasc Biol. 2011;31:1011–5.PubMedCrossRef Silvola JM, Saraste A, Forsback S, Laine VJ, Saukko P, Heinonen SE, et al. Detection of hypoxia by [18F]EF5 in atherosclerotic plaques in mice. Arterioscler Thromb Vasc Biol. 2011;31:1011–5.PubMedCrossRef
12.
go back to reference Anderson CJ, Bulte JW, Chen K, Chen X, Khaw BA, Shokeen M, et al. Design of targeted cardiovascular molecular imaging probes. J Nucl Med. 2010;51:3S–17S.PubMedCrossRef Anderson CJ, Bulte JW, Chen K, Chen X, Khaw BA, Shokeen M, et al. Design of targeted cardiovascular molecular imaging probes. J Nucl Med. 2010;51:3S–17S.PubMedCrossRef
13.
go back to reference Nahrendorf M, Zhang H, Hembrador S, Panizzi P, Sosnovik DE, Aikawa E, et al. Nanoparticle PET-CT imaging of macrophages in inflammatory atherosclerosis. Circulation. 2008;117:379–87.PubMedCrossRef Nahrendorf M, Zhang H, Hembrador S, Panizzi P, Sosnovik DE, Aikawa E, et al. Nanoparticle PET-CT imaging of macrophages in inflammatory atherosclerosis. Circulation. 2008;117:379–87.PubMedCrossRef
14.
go back to reference Ujula T, Huttunen M, Luoto P, Perakyla H, Simpura I, Wilson I, et al. Matrix metalloproteinase 9 targeting peptides: Syntheses, 68Ga-labeling, and preliminary evaluation in a rat melanoma xenograft model. Bioconjug Chem. 2010;21:1612–21.PubMedCrossRef Ujula T, Huttunen M, Luoto P, Perakyla H, Simpura I, Wilson I, et al. Matrix metalloproteinase 9 targeting peptides: Syntheses, 68Ga-labeling, and preliminary evaluation in a rat melanoma xenograft model. Bioconjug Chem. 2010;21:1612–21.PubMedCrossRef
15.
go back to reference Dweck MR, Chow MW, Joshi NV, Williams MC, Jones C, Fletcher AM, et al. Coronary arterial 18F-sodium fluoride uptake: a novel marker of plaque biology. J Am Coll Cardiol. 2012;59:1539–48.PubMedCrossRef Dweck MR, Chow MW, Joshi NV, Williams MC, Jones C, Fletcher AM, et al. Coronary arterial 18F-sodium fluoride uptake: a novel marker of plaque biology. J Am Coll Cardiol. 2012;59:1539–48.PubMedCrossRef
16.
go back to reference Solingapuram Sai KK, Kil KE, Tu Z, Chu W, Finck BN, Rothfuss JM, et al. Synthesis, radiolabeling and initial in vivo evaluation of [(11)C]KSM-01 for imaging PPAR-alpha receptors. Bioorg Med Chem Lett. 2012;22:6233–6.PubMedCrossRef Solingapuram Sai KK, Kil KE, Tu Z, Chu W, Finck BN, Rothfuss JM, et al. Synthesis, radiolabeling and initial in vivo evaluation of [(11)C]KSM-01 for imaging PPAR-alpha receptors. Bioorg Med Chem Lett. 2012;22:6233–6.PubMedCrossRef
17.
go back to reference Lee H, Chen DL, Rothfuss JM, Welch MJ, Gropler RJ, Mach RH. Synthesis and evaluation of 18F-labeled PPARgamma antagonists. Nucl Med Biol. 2012;39:77–87.PubMedCrossRef Lee H, Chen DL, Rothfuss JM, Welch MJ, Gropler RJ, Mach RH. Synthesis and evaluation of 18F-labeled PPARgamma antagonists. Nucl Med Biol. 2012;39:77–87.PubMedCrossRef
18.
go back to reference DeGrado TR, Bhattacharyya F, Pandey MK, Belanger AP, Wang S. Synthesis and preliminary evaluation of 18-(18)F-fluoro-4-thia-oleate as a PET probe of fatty acid oxidation. J Nucl Med. 2010;51:1310–7.PubMedCrossRef DeGrado TR, Bhattacharyya F, Pandey MK, Belanger AP, Wang S. Synthesis and preliminary evaluation of 18-(18)F-fluoro-4-thia-oleate as a PET probe of fatty acid oxidation. J Nucl Med. 2010;51:1310–7.PubMedCrossRef
19.
go back to reference Thomas AJ, DaSilva JN, Lortie M, Renaud JM, Kenk M, Beanlands RS, et al. PET of (R)-11C-rolipram binding to phosphodiesterase-4 is reproducible and sensitive to increased norepinephrine in the rat heart. J Nucl Med. 2011;52:263–9.PubMedCrossRef Thomas AJ, DaSilva JN, Lortie M, Renaud JM, Kenk M, Beanlands RS, et al. PET of (R)-11C-rolipram binding to phosphodiesterase-4 is reproducible and sensitive to increased norepinephrine in the rat heart. J Nucl Med. 2011;52:263–9.PubMedCrossRef
20.
go back to reference Herrero P, Laforest R, Shoghi K, Zhou D, Ewald G, Pfeifer J, et al. Feasibility and dosimetry studies for 18F-NOS as a potential PET radiopharmaceutical for inducible nitric oxide synthase in humans. J Nucl Med. 2012;53:994–1001.PubMedCrossRef Herrero P, Laforest R, Shoghi K, Zhou D, Ewald G, Pfeifer J, et al. Feasibility and dosimetry studies for 18F-NOS as a potential PET radiopharmaceutical for inducible nitric oxide synthase in humans. J Nucl Med. 2012;53:994–1001.PubMedCrossRef
21.
go back to reference Higuchi T, Fukushima K, Xia J, Mathews WB, Lautamaki R, Bravo PE, et al. Radionuclide imaging of angiotensin II type 1 receptor upregulation after myocardial ischemia-reperfusion injury. J Nucl Med. 2010;51:1956–61.PubMedCrossRef Higuchi T, Fukushima K, Xia J, Mathews WB, Lautamaki R, Bravo PE, et al. Radionuclide imaging of angiotensin II type 1 receptor upregulation after myocardial ischemia-reperfusion injury. J Nucl Med. 2010;51:1956–61.PubMedCrossRef
22.
go back to reference Lehner S, Todica A, Brunner S, Uebleis C, Wang H, Wängler C, et al. Temporal changes in phosphatidylserine expression and glucose metabolism after myocardial infarction: an in vivo imaging study in mice. Mol Imaging. 2012;11:461–70.PubMed Lehner S, Todica A, Brunner S, Uebleis C, Wang H, Wängler C, et al. Temporal changes in phosphatidylserine expression and glucose metabolism after myocardial infarction: an in vivo imaging study in mice. Mol Imaging. 2012;11:461–70.PubMed
23.
go back to reference Lautamaki R, Terrovitis J, Bonios M, Yu J, Tsui BM, Abraham MR, et al. Perfusion defect size predicts engraftment but not early retention of intra-myocardially injected cardiosphere-derived cells after acute myocardial infarction. Basic Res Cardiol. 2011;106:1379–86.PubMedCrossRef Lautamaki R, Terrovitis J, Bonios M, Yu J, Tsui BM, Abraham MR, et al. Perfusion defect size predicts engraftment but not early retention of intra-myocardially injected cardiosphere-derived cells after acute myocardial infarction. Basic Res Cardiol. 2011;106:1379–86.PubMedCrossRef
24.
go back to reference Ziadi MC, Dekemp RA, Williams K, Guo A, Renaud JM, Chow BJ, et al. Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease? J Nucl Cardiol. 2012;19:670–80.PubMedCrossRef Ziadi MC, Dekemp RA, Williams K, Guo A, Renaud JM, Chow BJ, et al. Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease? J Nucl Cardiol. 2012;19:670–80.PubMedCrossRef
25.
go back to reference • Yu M, Nekolla SG, Schwaiger M, Robinson SP. The next generation of cardiac positron emission tomography imaging agents: discovery of flurpiridaz F-18 for detection of coronary disease. Semin Nucl Med. 2011;41:305–13. Promising recent novel PET myocardial perfusion radiotracers.PubMedCrossRef • Yu M, Nekolla SG, Schwaiger M, Robinson SP. The next generation of cardiac positron emission tomography imaging agents: discovery of flurpiridaz F-18 for detection of coronary disease. Semin Nucl Med. 2011;41:305–13. Promising recent novel PET myocardial perfusion radiotracers.PubMedCrossRef
26.
go back to reference Mou T, Zhao Z, Fang W, Peng C, Guo F, Liu B, et al. Synthesis and preliminary evaluation of 18F-labeled pyridaben analogues for myocardial perfusion imaging with PET. J Nucl Med. 2012;53:472–9.PubMedCrossRef Mou T, Zhao Z, Fang W, Peng C, Guo F, Liu B, et al. Synthesis and preliminary evaluation of 18F-labeled pyridaben analogues for myocardial perfusion imaging with PET. J Nucl Med. 2012;53:472–9.PubMedCrossRef
27.
go back to reference Kim DY, Kim HS, Le UN, Jiang SN, Kim HJ, Lee KC, et al. Evaluation of a mitochondrial voltage sensor, (18F-fluoropentyl)triphenylphosphonium cation, in a rat myocardial infarction model. J Nucl Med. 2012;53:1779–85. Kim DY, Kim HS, Le UN, Jiang SN, Kim HJ, Lee KC, et al. Evaluation of a mitochondrial voltage sensor, (18F-fluoropentyl)triphenylphosphonium cation, in a rat myocardial infarction model. J Nucl Med. 2012;53:1779–85.
28.
go back to reference Gottumukkala V, Heinrich TK, Baker A, Dunning P, Fahey FH, Treves ST, et al. Biodistribution and stability studies of [18F]fluoroethylrhodamine B, a potential PET myocardial perfusion agent. Nucl Med Biol. 2010;37:365–70.PubMedCrossRef Gottumukkala V, Heinrich TK, Baker A, Dunning P, Fahey FH, Treves ST, et al. Biodistribution and stability studies of [18F]fluoroethylrhodamine B, a potential PET myocardial perfusion agent. Nucl Med Biol. 2010;37:365–70.PubMedCrossRef
29.
go back to reference • Whitman SC. A practical approach to using mice in atherosclerosis research. Clin Biochem Rev. 2004;25:81–93. Overview of ischemia-reperfusion and infarction mice models.PubMed • Whitman SC. A practical approach to using mice in atherosclerosis research. Clin Biochem Rev. 2004;25:81–93. Overview of ischemia-reperfusion and infarction mice models.PubMed
30.
go back to reference Zhang G, Li M, Li L, Xu Y, Li P, Yang C, et al. The immunologic injury composite with balloon injury leads to dyslipidemia: a robust rabbit model of human atherosclerosis and vulnerable plaque. J Biomed Biotechnol. 2012;2012:249129.PubMed Zhang G, Li M, Li L, Xu Y, Li P, Yang C, et al. The immunologic injury composite with balloon injury leads to dyslipidemia: a robust rabbit model of human atherosclerosis and vulnerable plaque. J Biomed Biotechnol. 2012;2012:249129.PubMed
31.
go back to reference Detombe SA, Ford NL, Xiang F, Lu X, Feng Q, Drangova M. Longitudinal follow-up of cardiac structure and functional changes in an infarct mouse model using retrospectively gated micro-computed tomography. Invest Radiol. 2008;43:520–9.PubMedCrossRef Detombe SA, Ford NL, Xiang F, Lu X, Feng Q, Drangova M. Longitudinal follow-up of cardiac structure and functional changes in an infarct mouse model using retrospectively gated micro-computed tomography. Invest Radiol. 2008;43:520–9.PubMedCrossRef
32.
go back to reference Gargiulo S, Greco A, Gramanzini M, Petretta MP, Ferro A, Larobina M, et al. PET/CT imaging in mouse models of myocardial ischemia. J Biomed Biotechnol. 2012;2012:541872.PubMedCrossRef Gargiulo S, Greco A, Gramanzini M, Petretta MP, Ferro A, Larobina M, et al. PET/CT imaging in mouse models of myocardial ischemia. J Biomed Biotechnol. 2012;2012:541872.PubMedCrossRef
33.
go back to reference Delso G, Martinez-Moller A, Bundschuh RA, Nekolla SG, Ziegler SI, Schwaiger M. Preliminary study of the detectability of coronary plaque with PET. Phys Med Biol. 2011;56:2145–60.PubMedCrossRef Delso G, Martinez-Moller A, Bundschuh RA, Nekolla SG, Ziegler SI, Schwaiger M. Preliminary study of the detectability of coronary plaque with PET. Phys Med Biol. 2011;56:2145–60.PubMedCrossRef
34.
go back to reference Aziz K, Berger K, Claycombe K, Huang R, Patel R, Abela GS. Noninvasive detection and localization of vulnerable plaque and arterial thrombosis with computed tomography angiography/positron emission tomography. Circulation. 2008;117:2061–70.PubMedCrossRef Aziz K, Berger K, Claycombe K, Huang R, Patel R, Abela GS. Noninvasive detection and localization of vulnerable plaque and arterial thrombosis with computed tomography angiography/positron emission tomography. Circulation. 2008;117:2061–70.PubMedCrossRef
35.
go back to reference van der Laarse A, van der Wall EE. Monitoring plaque composition: is it worthwile? Int J Cardiovasc Imaging. 2009;25:259–61.PubMedCrossRef van der Laarse A, van der Wall EE. Monitoring plaque composition: is it worthwile? Int J Cardiovasc Imaging. 2009;25:259–61.PubMedCrossRef
36.
go back to reference Croteau E, Gascon S, Bentourkia M, Langlois R, Rousseau JA, Lecomte R, et al. 11C]acetate rest-stress protocol to assess myocardial perfusion and oxygen consumption reserve in a model of congestive heart failure in rats. Nucl Med Biol. 2012;39:287–94.PubMedCrossRef Croteau E, Gascon S, Bentourkia M, Langlois R, Rousseau JA, Lecomte R, et al. 11C]acetate rest-stress protocol to assess myocardial perfusion and oxygen consumption reserve in a model of congestive heart failure in rats. Nucl Med Biol. 2012;39:287–94.PubMedCrossRef
37.
go back to reference Szanda I, Mackewn J, Patay G, Major P, Sunassee K, Mullen GE, et al. National electrical manufacturers association NU-4 performance evaluation of the PET component of the NanoPET/CT preclinical PET/CT scanner. J Nucl Med. 2011;52:1741–7.PubMedCrossRef Szanda I, Mackewn J, Patay G, Major P, Sunassee K, Mullen GE, et al. National electrical manufacturers association NU-4 performance evaluation of the PET component of the NanoPET/CT preclinical PET/CT scanner. J Nucl Med. 2011;52:1741–7.PubMedCrossRef
40.
go back to reference Bergeron M, Thibaudeau C, Cadorette J, Pepin C, Tetrault M, Davies M, et al. LabPET II, an APD-based PET detector module with counting CT imaging capability. IEEE Nucl Sci Symp Conf Rec. 2011.:3543–3547. Bergeron M, Thibaudeau C, Cadorette J, Pepin C, Tetrault M, Davies M, et al. LabPET II, an APD-based PET detector module with counting CT imaging capability. IEEE Nucl Sci Symp Conf Rec. 2011.:3543–3547.
44.
go back to reference Visser EP, Disselhorst JA, Brom M, Laverman P, Gotthardt M, Oyen WJ, et al. Spatial resolution and sensitivity of the inveon small-animal PET scanner. J Nucl Med. 2009;50:139–47.PubMedCrossRef Visser EP, Disselhorst JA, Brom M, Laverman P, Gotthardt M, Oyen WJ, et al. Spatial resolution and sensitivity of the inveon small-animal PET scanner. J Nucl Med. 2009;50:139–47.PubMedCrossRef
45.
go back to reference Siemens S. INVEON PET/CT. 2012. Website: Healthcare.siemens.com/molecular-imaging/preclinical-imaging/inveon-configurations/inveon-docked-pet-ct. Siemens S. INVEON PET/CT. 2012. Website: Healthcare.siemens.com/molecular-imaging/preclinical-imaging/inveon-configurations/inveon-docked-pet-ct.
46.
go back to reference Sanchez F, Moliner L, Correcher C, Gonzalez A, Orero A, Carles M, et al. Small animal PET scanner based on monolithic LYSO crystals: performance evaluation. Med Phys. 2012;39:643–53.PubMedCrossRef Sanchez F, Moliner L, Correcher C, Gonzalez A, Orero A, Carles M, et al. Small animal PET scanner based on monolithic LYSO crystals: performance evaluation. Med Phys. 2012;39:643–53.PubMedCrossRef
47.
go back to reference Yang Y, James SS, Wu Y, Du H, Qi J, Farrell R, et al. Tapered LSO arrays for small animal PET. Phys Med Biol. 2011;56:139–53.PubMedCrossRef Yang Y, James SS, Wu Y, Du H, Qi J, Farrell R, et al. Tapered LSO arrays for small animal PET. Phys Med Biol. 2011;56:139–53.PubMedCrossRef
48.
go back to reference Yoshida E, Kinouchi S, Tashima H, Nishikido F, Inadama N, Murayama H, et al. System design of a small OpenPET prototype with 4-layer DOI detectors. Radiol Phys Technol. 2012;5:92–7.PubMedCrossRef Yoshida E, Kinouchi S, Tashima H, Nishikido F, Inadama N, Murayama H, et al. System design of a small OpenPET prototype with 4-layer DOI detectors. Radiol Phys Technol. 2012;5:92–7.PubMedCrossRef
49.
go back to reference Bircher C, Shao Y. Investigation of crystal surface finish and geometry on single LYSO scintillator detector performance for depth-of-interaction measurement with silicon photomultipliers. Nucl Instrum Methods Phys Res A. 2012;693:236–43.PubMedCrossRef Bircher C, Shao Y. Investigation of crystal surface finish and geometry on single LYSO scintillator detector performance for depth-of-interaction measurement with silicon photomultipliers. Nucl Instrum Methods Phys Res A. 2012;693:236–43.PubMedCrossRef
50.
go back to reference Gu Y, Matteson JL, Skelton RT, Deal AC, Stephan EA, Duttweiler F, et al. Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET. Phys Med Biol. 2011;56:1563–84.PubMedCrossRef Gu Y, Matteson JL, Skelton RT, Deal AC, Stephan EA, Duttweiler F, et al. Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET. Phys Med Biol. 2011;56:1563–84.PubMedCrossRef
51.
go back to reference Levin CS. Promising new photon detection concepts for high-resolution clinical and preclinical PET. J Nucl Med. 2012;53:167–70.PubMedCrossRef Levin CS. Promising new photon detection concepts for high-resolution clinical and preclinical PET. J Nucl Med. 2012;53:167–70.PubMedCrossRef
52.
go back to reference Kolb A, Lorenz E, Judenhofer MS, Renker D, Lankes K, Pichler BJ. Evaluation of geiger-mode APDs for PET block detector designs. Phys Med Biol. 2010;55:1815–32.PubMedCrossRef Kolb A, Lorenz E, Judenhofer MS, Renker D, Lankes K, Pichler BJ. Evaluation of geiger-mode APDs for PET block detector designs. Phys Med Biol. 2010;55:1815–32.PubMedCrossRef
53.
go back to reference Buscher K, Judenhofer MS, Kuhlmann MT, Hermann S, Wehrl HF, Schafers KP, et al. Isochronous assessment of cardiac metabolism and function in mice using hybrid PET/MRI. J Nucl Med. 2010;51:1277–84.PubMedCrossRef Buscher K, Judenhofer MS, Kuhlmann MT, Hermann S, Wehrl HF, Schafers KP, et al. Isochronous assessment of cardiac metabolism and function in mice using hybrid PET/MRI. J Nucl Med. 2010;51:1277–84.PubMedCrossRef
54.
go back to reference Tsui BM, Kraitchman DL. Recent advances in small-animal cardiovascular imaging. J Nucl Med. 2009;50:667–70.PubMedCrossRef Tsui BM, Kraitchman DL. Recent advances in small-animal cardiovascular imaging. J Nucl Med. 2009;50:667–70.PubMedCrossRef
55.
go back to reference Liu B, Wang G, Ritman EL, Cao G, Lu J, Zhou O, et al. Image reconstruction from limited angle projections collected by multisource interior x-ray imaging systems. Phys Med Biol. 2011;56:6337–57.PubMedCrossRef Liu B, Wang G, Ritman EL, Cao G, Lu J, Zhou O, et al. Image reconstruction from limited angle projections collected by multisource interior x-ray imaging systems. Phys Med Biol. 2011;56:6337–57.PubMedCrossRef
56.
go back to reference Thibaudeau C, Bérard P, Tétrault MA, Leroux JD, Bergeron M, Fontaine R, et al. Toward truly combined PET/CT imaging using PET detectors and photon counting CT with iterative reconstruction implementing physical detector response. Med Phys. 2012;39:5697–707.PubMedCrossRef Thibaudeau C, Bérard P, Tétrault MA, Leroux JD, Bergeron M, Fontaine R, et al. Toward truly combined PET/CT imaging using PET detectors and photon counting CT with iterative reconstruction implementing physical detector response. Med Phys. 2012;39:5697–707.PubMedCrossRef
57.
go back to reference Badea CT, Fubara B, Hedlund LW, Johnson GA. 4-D micro-CT of the mouse heart. Mol Imaging. 2005;4:110–6.PubMed Badea CT, Fubara B, Hedlund LW, Johnson GA. 4-D micro-CT of the mouse heart. Mol Imaging. 2005;4:110–6.PubMed
58.
go back to reference Nahrendorf M, Badea C, Hedlund LW, Figueiredo JL, Sosnovik DE, Johnson GA, et al. High-resolution imaging of murine myocardial infarction with delayed-enhancement cine micro-CT. Am J Physiol Heart Circ Physiol. 2007;292:H3172–8.PubMedCrossRef Nahrendorf M, Badea C, Hedlund LW, Figueiredo JL, Sosnovik DE, Johnson GA, et al. High-resolution imaging of murine myocardial infarction with delayed-enhancement cine micro-CT. Am J Physiol Heart Circ Physiol. 2007;292:H3172–8.PubMedCrossRef
59.
go back to reference Tran DN, Straka M, Roos JE, Napel S, Fleischmann D. Dual-energy CT discrimination of iodine and calcium: Experimental results and implications for lower extremity CT angiography. Acad Radiol. 2009;16:160–71.PubMedCrossRef Tran DN, Straka M, Roos JE, Napel S, Fleischmann D. Dual-energy CT discrimination of iodine and calcium: Experimental results and implications for lower extremity CT angiography. Acad Radiol. 2009;16:160–71.PubMedCrossRef
60.
go back to reference Schultke E, Fiedler S, Nemoz C, Ogieglo L, Kelly ME, Crawford P, et al. Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: a feasibility study. Eur J Radiol. 2010;73:677–81.PubMedCrossRef Schultke E, Fiedler S, Nemoz C, Ogieglo L, Kelly ME, Crawford P, et al. Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: a feasibility study. Eur J Radiol. 2010;73:677–81.PubMedCrossRef
61.
go back to reference Lundstrom U, Larsson DH, Burvall A, Takman PA, Scott L, Brismar H, et al. X-ray phase contrast for CO2 microangiography. Phys Med Biol. 2012;57:2603–17.PubMedCrossRef Lundstrom U, Larsson DH, Burvall A, Takman PA, Scott L, Brismar H, et al. X-ray phase contrast for CO2 microangiography. Phys Med Biol. 2012;57:2603–17.PubMedCrossRef
62.
go back to reference Kerl HU, Isaza CT, Boll H, Schambach SJ, Nolte IS, Groden C, et al. Evaluation of a continuous-rotation, high-speed scanning protocol for micro-computed tomography. J Comput Assist Tomogr. 2011;35:517–23.PubMedCrossRef Kerl HU, Isaza CT, Boll H, Schambach SJ, Nolte IS, Groden C, et al. Evaluation of a continuous-rotation, high-speed scanning protocol for micro-computed tomography. J Comput Assist Tomogr. 2011;35:517–23.PubMedCrossRef
63.
go back to reference Ropinski T, Hermann S, Reich R, Schafers M, Hinrichs K. Multimodal vessel visualization of mouse aorta PET/CT scans. IEEE Trans Vis Comput Graph. 2009;15:1515–22.PubMedCrossRef Ropinski T, Hermann S, Reich R, Schafers M, Hinrichs K. Multimodal vessel visualization of mouse aorta PET/CT scans. IEEE Trans Vis Comput Graph. 2009;15:1515–22.PubMedCrossRef
64.
go back to reference Pascau J, Vaquero JJ, Chamorro-Servent J, Rodriguez-Ruano A, Desco M. A method for small-animal PET/CT alignment calibration. Phys Med Biol. 2012;57:N199–207.PubMedCrossRef Pascau J, Vaquero JJ, Chamorro-Servent J, Rodriguez-Ruano A, Desco M. A method for small-animal PET/CT alignment calibration. Phys Med Biol. 2012;57:N199–207.PubMedCrossRef
65.
go back to reference Feng B, Yan S, Chen M, Austin D, Deng J, Mintzer R. Automated least-squares calibration of the coregistration parameters for a micro PET-CT system. IEEE Trans Nucl Sci. 2011;58:2303–7.CrossRef Feng B, Yan S, Chen M, Austin D, Deng J, Mintzer R. Automated least-squares calibration of the coregistration parameters for a micro PET-CT system. IEEE Trans Nucl Sci. 2011;58:2303–7.CrossRef
66.
go back to reference Chow PL, Stout DB, Komisopoulou E, Chatziioannou AF. A method of image registration for small animal, multi-modality imaging. Phys Med Biol. 2006;51:379–90.PubMedCrossRef Chow PL, Stout DB, Komisopoulou E, Chatziioannou AF. A method of image registration for small animal, multi-modality imaging. Phys Med Biol. 2006;51:379–90.PubMedCrossRef
67.
go back to reference Del Guerra A, Belcari N. State-of-the-art of PET, SPECT and CT for small animal imaging. Nucl Instrum Meth Phys Res A. 2007;583:119–24.CrossRef Del Guerra A, Belcari N. State-of-the-art of PET, SPECT and CT for small animal imaging. Nucl Instrum Meth Phys Res A. 2007;583:119–24.CrossRef
68.
go back to reference Chow PL, Rannou FR, Chatziioannou AF. Attenuation correction for small animal PET tomographs. Phys Med Biol. 2005;50:1837–50.PubMedCrossRef Chow PL, Rannou FR, Chatziioannou AF. Attenuation correction for small animal PET tomographs. Phys Med Biol. 2005;50:1837–50.PubMedCrossRef
69.
go back to reference Konik A, Koesters T, Madsen MT, Sunderland JJ. Evaluation of attenuation and scatter correction requirements as a function of object size in small animal PET imaging. IEEE Trans on Nucl Sci. 2011;5:2308–14.CrossRef Konik A, Koesters T, Madsen MT, Sunderland JJ. Evaluation of attenuation and scatter correction requirements as a function of object size in small animal PET imaging. IEEE Trans on Nucl Sci. 2011;5:2308–14.CrossRef
70.
go back to reference Yao R, Lecomte R, Crawford ES. Small-animal PET: what is it, and why do we need it? J Nucl Med Technol. 2012;40:157–65.PubMedCrossRef Yao R, Lecomte R, Crawford ES. Small-animal PET: what is it, and why do we need it? J Nucl Med Technol. 2012;40:157–65.PubMedCrossRef
71.
go back to reference • de Kemp RA, Epstein FH, Catana C, Tsui BM, Ritman EL. Small-animal molecular imaging methods. J Nucl Med. 2010;51:18S–32S. Comprehensive review of instrumentation in small animal molecular imaging.PubMedCrossRef • de Kemp RA, Epstein FH, Catana C, Tsui BM, Ritman EL. Small-animal molecular imaging methods. J Nucl Med. 2010;51:18S–32S. Comprehensive review of instrumentation in small animal molecular imaging.PubMedCrossRef
72.
go back to reference Cheng JC, Shoghi K, Laforest R. Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals. Med Phys. 2012;39:1029–41.PubMedCrossRef Cheng JC, Shoghi K, Laforest R. Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals. Med Phys. 2012;39:1029–41.PubMedCrossRef
73.
go back to reference Rousset O, Rahmim A, Alavi A, Zaidi H. Partial volume correction strategies in PET. PET Clin. 2007;2:235–49.CrossRef Rousset O, Rahmim A, Alavi A, Zaidi H. Partial volume correction strategies in PET. PET Clin. 2007;2:235–49.CrossRef
74.
go back to reference Dumouchel T, Thorn S, Kordos M, DaSilva J, Beanlands RS, deKemp RA. A three-dimensional model-based partial volume correction strategy for gated cardiac mouse PET imaging. Phys Med Biol. 2012;57:4309–34.PubMedCrossRef Dumouchel T, Thorn S, Kordos M, DaSilva J, Beanlands RS, deKemp RA. A three-dimensional model-based partial volume correction strategy for gated cardiac mouse PET imaging. Phys Med Biol. 2012;57:4309–34.PubMedCrossRef
75.
go back to reference Croteau E, Lavallee E, Labbe SM, Hubert L, Pifferi F, Rousseau JA, et al. Image-derived input function in dynamic human PET/CT: Methodology and validation with 11C-acetate and 18F-fluorothioheptadecanoic acid in muscle and 18F-fluorodeoxyglucose in brain. Eur J Nucl Med Mol Imaging. 2010;37:1539–50.PubMedCrossRef Croteau E, Lavallee E, Labbe SM, Hubert L, Pifferi F, Rousseau JA, et al. Image-derived input function in dynamic human PET/CT: Methodology and validation with 11C-acetate and 18F-fluorothioheptadecanoic acid in muscle and 18F-fluorodeoxyglucose in brain. Eur J Nucl Med Mol Imaging. 2010;37:1539–50.PubMedCrossRef
76.
go back to reference Johnson NP, Sdringola S, Gould KL. Partial volume correction incorporating rb-82 positron range for quantitative myocardial perfusion PET based on systolic-diastolic activity ratios and phantom measurements. J Nucl Cardiol. 2011;18:247–58.PubMedCrossRef Johnson NP, Sdringola S, Gould KL. Partial volume correction incorporating rb-82 positron range for quantitative myocardial perfusion PET based on systolic-diastolic activity ratios and phantom measurements. J Nucl Cardiol. 2011;18:247–58.PubMedCrossRef
77.
go back to reference Lehnert W, Gregoire MC, Reilhac A, Meikle SR. Characterisation of partial volume effect and region-based correction in small animal positron emission tomography (PET) of the rat brain. NeuroImage. 2012;60:2144–57.PubMedCrossRef Lehnert W, Gregoire MC, Reilhac A, Meikle SR. Characterisation of partial volume effect and region-based correction in small animal positron emission tomography (PET) of the rat brain. NeuroImage. 2012;60:2144–57.PubMedCrossRef
78.
go back to reference Yang Y, Rendig S, Siegel S, Newport DF, Cherry SR. Cardiac PET imaging in mice with simultaneous cardiac and respiratory gating. Phys Med Biol. 2005;50:2979–89.PubMedCrossRef Yang Y, Rendig S, Siegel S, Newport DF, Cherry SR. Cardiac PET imaging in mice with simultaneous cardiac and respiratory gating. Phys Med Biol. 2005;50:2979–89.PubMedCrossRef
79.
go back to reference Su Y. Inter-frame motion correction for small animal PET imaging. IEEE Int Conf Biomed Eng Inform. 2011;1:338–42. Su Y. Inter-frame motion correction for small animal PET imaging. IEEE Int Conf Biomed Eng Inform. 2011;1:338–42.
80.
go back to reference Kramer CM, Sinusas AJ, Sosnovik DE, French BA, Bengel FM. Multimodality imaging of myocardial injury and remodeling. J Nucl Med. 2010;51 Suppl 1:107S–21S.PubMedCrossRef Kramer CM, Sinusas AJ, Sosnovik DE, French BA, Bengel FM. Multimodality imaging of myocardial injury and remodeling. J Nucl Med. 2010;51 Suppl 1:107S–21S.PubMedCrossRef
81.
go back to reference •• Nahrendorf M, Sosnovik DE, French BA, Swirski FK, Bengel F, Sadeghi MM, et al. Multimodality cardiovascular molecular imaging, part II. Circ Cardiovasc Imaging. 2009;2:56–70. Comprehensive review of multimodality imaging of cardiac molecular disease.PubMedCrossRef •• Nahrendorf M, Sosnovik DE, French BA, Swirski FK, Bengel F, Sadeghi MM, et al. Multimodality cardiovascular molecular imaging, part II. Circ Cardiovasc Imaging. 2009;2:56–70. Comprehensive review of multimodality imaging of cardiac molecular disease.PubMedCrossRef
82.
go back to reference Rydberg J, Buckwalter KA, Caldemeyer KS, Phillips MD, Conces Jr DJ, Aisen AM, et al. Multisection CT: scanning techniques and clinical applications. Radiographics. 2000;20:1787–806.PubMed Rydberg J, Buckwalter KA, Caldemeyer KS, Phillips MD, Conces Jr DJ, Aisen AM, et al. Multisection CT: scanning techniques and clinical applications. Radiographics. 2000;20:1787–806.PubMed
83.
go back to reference Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology. 2010;256:32–61.PubMedCrossRef Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology. 2010;256:32–61.PubMedCrossRef
84.
go back to reference Van de Veire NR, Schuijf JD, De Sutter J, Devos D, Bleeker GB, de Roos A, et al. Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography. J Am Coll Cardiol. 2006;48:1832–8.PubMedCrossRef Van de Veire NR, Schuijf JD, De Sutter J, Devos D, Bleeker GB, de Roos A, et al. Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography. J Am Coll Cardiol. 2006;48:1832–8.PubMedCrossRef
85.
go back to reference Malyar NM, Gossl M, Beighley PE, Ritman EL. Relationship between arterial diameter and perfused tissue volume in myocardial microcirculation: a micro-CT-based analysis. Am J Physiol Heart Circ Physiol. 2004;286:H2386–92.PubMedCrossRef Malyar NM, Gossl M, Beighley PE, Ritman EL. Relationship between arterial diameter and perfused tissue volume in myocardial microcirculation: a micro-CT-based analysis. Am J Physiol Heart Circ Physiol. 2004;286:H2386–92.PubMedCrossRef
86.
go back to reference Sangaralingham SJ, Ritman EL, McKie PM, Ichiki T, Lerman A, Scott CG, et al. Cardiac micro-computed tomography imaging of the aging coronary vasculature. Circ Cardiovasc Imaging. 2012;5:518–24.PubMedCrossRef Sangaralingham SJ, Ritman EL, McKie PM, Ichiki T, Lerman A, Scott CG, et al. Cardiac micro-computed tomography imaging of the aging coronary vasculature. Circ Cardiovasc Imaging. 2012;5:518–24.PubMedCrossRef
87.
go back to reference Detombe SA, Dunmore-Buyze J, Drangova M. Evaluation of eXIA 160 cardiac-related enhancement in C57BL/6 and BALB/c mice using micro-CT. Contrast Media Mol Imaging. 2012;7:240–6.PubMedCrossRef Detombe SA, Dunmore-Buyze J, Drangova M. Evaluation of eXIA 160 cardiac-related enhancement in C57BL/6 and BALB/c mice using micro-CT. Contrast Media Mol Imaging. 2012;7:240–6.PubMedCrossRef
88.
go back to reference Roosens B, Bala G, Droogmans S, Hostens J, Somja J, Delvenne E, et al. Occurrence of cardiovascular calcifications in normal, aging rats. Exp Gerontol. 2012;47:614–9.PubMedCrossRef Roosens B, Bala G, Droogmans S, Hostens J, Somja J, Delvenne E, et al. Occurrence of cardiovascular calcifications in normal, aging rats. Exp Gerontol. 2012;47:614–9.PubMedCrossRef
89.
go back to reference Willekens I, Buls N, Lahoutte T, Baeyens L, Vanhove C, Caveliers V, et al. Evaluation of the radiation dose in micro-CT with optimization of the scan protocol. Contrast Media Mol Imaging. 2010;5:201–7.PubMedCrossRef Willekens I, Buls N, Lahoutte T, Baeyens L, Vanhove C, Caveliers V, et al. Evaluation of the radiation dose in micro-CT with optimization of the scan protocol. Contrast Media Mol Imaging. 2010;5:201–7.PubMedCrossRef
90.
go back to reference •• Schambach SJ, Bag S, Schilling L, Groden C, Brockmann MA. Application of micro-CT in small animal imaging. Methods. 2010;50:2–13. Recent overview of micro CT.PubMedCrossRef •• Schambach SJ, Bag S, Schilling L, Groden C, Brockmann MA. Application of micro-CT in small animal imaging. Methods. 2010;50:2–13. Recent overview of micro CT.PubMedCrossRef
91.
go back to reference Liang L, Mendonca MS, Deng L, Nguyen SC, Shao C, Tischfield JA. Reduced apoptosis and increased deletion mutations at aprt locus in vivo in mice exposed to repeated ionizing radiation. Cancer Res. 2007;67:1910–7.PubMedCrossRef Liang L, Mendonca MS, Deng L, Nguyen SC, Shao C, Tischfield JA. Reduced apoptosis and increased deletion mutations at aprt locus in vivo in mice exposed to repeated ionizing radiation. Cancer Res. 2007;67:1910–7.PubMedCrossRef
92.
go back to reference •• Kersemans V, Thompson J, Cornelissen B, Woodcock M, Allen PD, Buls N, et al. Micro-CT for anatomic referencing in PET and SPECT: radiation dose, biologic damage, and image quality. J Nucl Med. 2011;52:1827–33. Recent reference for the dosimetry of micro CT.PubMedCrossRef •• Kersemans V, Thompson J, Cornelissen B, Woodcock M, Allen PD, Buls N, et al. Micro-CT for anatomic referencing in PET and SPECT: radiation dose, biologic damage, and image quality. J Nucl Med. 2011;52:1827–33. Recent reference for the dosimetry of micro CT.PubMedCrossRef
93.
go back to reference •• Funk T, Sun M, Hasegawa BH. Radiation dose estimate in small animal SPECT and PET. Med Phys. 2004;31:2680–6. Reference for the dosimetry for radiotracers in small animal imaging.PubMedCrossRef •• Funk T, Sun M, Hasegawa BH. Radiation dose estimate in small animal SPECT and PET. Med Phys. 2004;31:2680–6. Reference for the dosimetry for radiotracers in small animal imaging.PubMedCrossRef
94.
go back to reference Hupfer M, Kolditz D, Nowak T, Eisa F, Brauweiler R, Kalender WA. Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT. Med Phys. 2012;39:658–70.PubMedCrossRef Hupfer M, Kolditz D, Nowak T, Eisa F, Brauweiler R, Kalender WA. Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT. Med Phys. 2012;39:658–70.PubMedCrossRef
95.
go back to reference Rodt T, Luepke M, Boehm C, Hueper K, Halter R, Glage S, et al. Combined micro-PET/Micro-CT imaging of lung tumours in SPC-raf and SPC-myc transgenic mice. PLoS One. 2012;7:e44427.PubMedCrossRef Rodt T, Luepke M, Boehm C, Hueper K, Halter R, Glage S, et al. Combined micro-PET/Micro-CT imaging of lung tumours in SPC-raf and SPC-myc transgenic mice. PLoS One. 2012;7:e44427.PubMedCrossRef
96.
go back to reference Brouwers JE, van Rietbergen B, Huiskes R. No effects of in vivo micro-CT radiation on structural parameters and bone marrow cells in proximal tibia of wistar rats detected after eight weekly scans. J Orthop Res. 2007;25:1325–32.PubMedCrossRef Brouwers JE, van Rietbergen B, Huiskes R. No effects of in vivo micro-CT radiation on structural parameters and bone marrow cells in proximal tibia of wistar rats detected after eight weekly scans. J Orthop Res. 2007;25:1325–32.PubMedCrossRef
97.
go back to reference Vandeghinste B, Trachet B, Renard M, Casteleyn C, Staelens S, Loeys B, et al. Replacing vascular corrosion casting by in vivo micro-CT imaging for building 3D cardiovascular models in mice. Mol Imaging Biol. 2011;13:78–86.PubMedCrossRef Vandeghinste B, Trachet B, Renard M, Casteleyn C, Staelens S, Loeys B, et al. Replacing vascular corrosion casting by in vivo micro-CT imaging for building 3D cardiovascular models in mice. Mol Imaging Biol. 2011;13:78–86.PubMedCrossRef
98.
go back to reference Schambach SJ, Bag S, Steil V, Isaza C, Schilling L, Groden C, et al. Ultrafast high-resolution in vivo volume-CTA of mice cerebral vessels. Stroke. 2009;40:1444–50.PubMedCrossRef Schambach SJ, Bag S, Steil V, Isaza C, Schilling L, Groden C, et al. Ultrafast high-resolution in vivo volume-CTA of mice cerebral vessels. Stroke. 2009;40:1444–50.PubMedCrossRef
Metadata
Title
Cardiac Micro-PET-CT
Authors
Etienne Croteau
Jennifer M. Renaud
Robert A. deKemp
Publication date
01-04-2013
Publisher
Current Science Inc.
Published in
Current Cardiovascular Imaging Reports / Issue 2/2013
Print ISSN: 1941-9066
Electronic ISSN: 1941-9074
DOI
https://doi.org/10.1007/s12410-012-9188-7

Other articles of this Issue 2/2013

Current Cardiovascular Imaging Reports 2/2013 Go to the issue

Technological Advances in Cardiac Multi-modality Imaging (TH Schindler, Section Editor)

Cardiac PET/MRI

Cardiac Magnetic Resonance (E Nagel, Section Editor)

Clinical Applications of Aortic 4D Flow Imaging