Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 5/2018

01-05-2018 | Original Paper

Cardiac and respiratory-gated volumetric murine ultrasound

Authors: Arvin H. Soepriatna, Frederick W. Damen, Pavlos P. Vlachos, Craig J. Goergen

Published in: The International Journal of Cardiovascular Imaging | Issue 5/2018

Login to get access

Abstract

Current cardiovascular ultrasound mainly employs planar imaging techniques to assess function and physiology. These techniques rely on geometric assumptions, which are dependent on the imaging plane, susceptible to inter-observer variability, and may be inaccurate when studying complex diseases. Here, we developed a gated volumetric murine ultrasound technique to visualize cardiovascular motion with high spatiotemporal resolution and directly evaluate cardiovascular health. Cardiac and respiratory-gated cine loops, acquired at 1000 frames-per-second from sequential positions, were temporally registered to generate a four-dimensional (4D) dataset. We applied this technique to (1) evaluate left ventricular (LV) function from both healthy mice and mice with myocardial infarction and (2) characterize aortic wall strain of angiotensin II-induced dissecting abdominal aortic aneurysms in apolipoprotein E-deficient mice. Combined imaging and processing times for the 4D technique was approximately 2–4 times longer than conventional 2D approaches, but substantially more data is collected with 4D ultrasound and further optimization can be implemented to reduce imaging times. Direct volumetric measurements of 4D cardiac data aligned closely with those obtained from MRI, contrary to conventional methods, which were sensitive to transducer alignment, leading to overestimation or underestimation of estimated LV parameters in infarcted hearts. Green–Lagrange circumferential strain analysis revealed higher strain values proximal and distal to the aneurysm than within the aneurysmal region, consistent with published reports. By eliminating the need for geometrical assumptions, the presented 4D technique can be used to more accurately evaluate cardiac function and aortic pulsatility. Furthermore, this technique allows for the visualization of regional differences that may be overlooked with conventional 2D approaches.
Appendix
Available only for authorised users
Literature
1.
go back to reference Mozaffarian D, Benjamin EJ, Go AS, Arnett DK, Blaha MJ, Cushman M, Das SR, de Ferranti S, Despres JP, Fullerton HJ, Howard VJ, Huffman MD, Isasi CR, Jimenez MC, Judd SE, Kissela BM, Lichtman JH, Lisabeth LD, Liu S, Mackey RH, Magid DJ, McGuire DK, Mohler ER, 3rd, Moy CS, Muntner P, Mussolino ME, Nasir K, Neumar RW, Nichol G, Palaniappan L, Pandey DK, Reeves MJ, Rodriguez CJ, Rosamond W, Sorlie PD, Stein J, Towfighi A, Turan TN, Virani SS, Woo D, Yeh RW, Turner MB, American Heart Association Statistics Committee, Stroke Statistics Subcommittee (2016) Heart disease and stroke statistics-2016 update: a report from the American Heart Association. Circulation 133 (4):e38–e60. https://doi.org/10.1161/CIR.0000000000000350 CrossRefPubMed Mozaffarian D, Benjamin EJ, Go AS, Arnett DK, Blaha MJ, Cushman M, Das SR, de Ferranti S, Despres JP, Fullerton HJ, Howard VJ, Huffman MD, Isasi CR, Jimenez MC, Judd SE, Kissela BM, Lichtman JH, Lisabeth LD, Liu S, Mackey RH, Magid DJ, McGuire DK, Mohler ER, 3rd, Moy CS, Muntner P, Mussolino ME, Nasir K, Neumar RW, Nichol G, Palaniappan L, Pandey DK, Reeves MJ, Rodriguez CJ, Rosamond W, Sorlie PD, Stein J, Towfighi A, Turan TN, Virani SS, Woo D, Yeh RW, Turner MB, American Heart Association Statistics Committee, Stroke Statistics Subcommittee (2016) Heart disease and stroke statistics-2016 update: a report from the American Heart Association. Circulation 133 (4):e38–e60. https://​doi.​org/​10.​1161/​CIR.​0000000000000350​ CrossRefPubMed
2.
go back to reference Heidenreich PA, Trogdon JG, Khavjou OA, Butler J, Dracup K, Ezekowitz MD, Finkelstein EA, Hong Y, Johnston SC, Khera A, Lloyd-Jones DM, Nelson SA, Nichol G, Orenstein D, Wilson PW, Woo YJ, American Heart Association Advocacy Coordinating Committee, Stroke Council, Council on Cardiovascular Radiology and Intervention, Council on Clinical Cardiology, Council on Epidemiology and Prevention, Council on Arteriosclerosis, Thrombosis and Vascular Biology, Council on Cardiopulmonary, Critical Care, Perioperative and Resuscitation, Council on Cardiovascular Nursing, Council on the Kidney in Cardiovascular Disease, Council on Cardiovascular Surgery and Anesthesia, Interdisciplinary Council on Quality of Care and Outcomes Research (2011) Forecasting the future of cardiovascular disease in the United States: a policy statement from the American Heart Association. Circulation 123 (8):933–944. https://doi.org/10.1161/CIR.0b013e31820a55f5 CrossRefPubMed Heidenreich PA, Trogdon JG, Khavjou OA, Butler J, Dracup K, Ezekowitz MD, Finkelstein EA, Hong Y, Johnston SC, Khera A, Lloyd-Jones DM, Nelson SA, Nichol G, Orenstein D, Wilson PW, Woo YJ, American Heart Association Advocacy Coordinating Committee, Stroke Council, Council on Cardiovascular Radiology and Intervention, Council on Clinical Cardiology, Council on Epidemiology and Prevention, Council on Arteriosclerosis, Thrombosis and Vascular Biology, Council on Cardiopulmonary, Critical Care, Perioperative and Resuscitation, Council on Cardiovascular Nursing, Council on the Kidney in Cardiovascular Disease, Council on Cardiovascular Surgery and Anesthesia, Interdisciplinary Council on Quality of Care and Outcomes Research (2011) Forecasting the future of cardiovascular disease in the United States: a policy statement from the American Heart Association. Circulation 123 (8):933–944. https://​doi.​org/​10.​1161/​CIR.​0b013e31820a55f5​ CrossRefPubMed
3.
go back to reference Li G, Citrin D, Camphausen K, Mueller B, Burman C, Mychalczak B, Miller RW, Song Y (2008) Advances in 4D medical imaging and 4D radiation therapy. Technol Cancer Res Treat 7(1):67–81CrossRefPubMed Li G, Citrin D, Camphausen K, Mueller B, Burman C, Mychalczak B, Miller RW, Song Y (2008) Advances in 4D medical imaging and 4D radiation therapy. Technol Cancer Res Treat 7(1):67–81CrossRefPubMed
5.
go back to reference Gao M, Huang J, Zhang S, Qian Z, Voros S, Metaxas D, Axel L (2011) 4D cardiac reconstruction using high resolution CT images. In: Functional imaging and modeling of the heart. Springer, Berlin, pp 153–160 Gao M, Huang J, Zhang S, Qian Z, Voros S, Metaxas D, Axel L (2011) 4D cardiac reconstruction using high resolution CT images. In: Functional imaging and modeling of the heart. Springer, Berlin, pp 153–160
6.
go back to reference Allen BD, Barker AJ, Parekh K, Sommerville LC, Schnell S, Jarvis KB, Carr M, Carr J, Collins J, Markl M (2013) Incorporating time-resolved three-dimensional phase contrast (4D flow) MRI in clinical workflow: initial experiences at a large tertiary care medical center. Resonance 15(1):P32 Allen BD, Barker AJ, Parekh K, Sommerville LC, Schnell S, Jarvis KB, Carr M, Carr J, Collins J, Markl M (2013) Incorporating time-resolved three-dimensional phase contrast (4D flow) MRI in clinical workflow: initial experiences at a large tertiary care medical center. Resonance 15(1):P32
13.
go back to reference Kaplan HM, Brewer NR, Blair WH (2007) Physiology. In: Fox JG, Barthold SW, Davisson MT et al (eds) The mouse in biomedical research, vol 3, 2nd edn. Academic Press, San Diego, pp 247–292 Kaplan HM, Brewer NR, Blair WH (2007) Physiology. In: Fox JG, Barthold SW, Davisson MT et al (eds) The mouse in biomedical research, vol 3, 2nd edn. Academic Press, San Diego, pp 247–292
14.
go back to reference Badea CT, Hedlund LW, Mackel JF, Mao L, Rockman HA, Johnson GA (2007) Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice. Mol Imaging 6(4):261–268CrossRefPubMedPubMedCentral Badea CT, Hedlund LW, Mackel JF, Mao L, Rockman HA, Johnson GA (2007) Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice. Mol Imaging 6(4):261–268CrossRefPubMedPubMedCentral
17.
go back to reference Keall PJ, Vedam SS, George R, Williamson JF (2007) Respiratory regularity gated 4D CT acquisition: concepts and proof of principle. Australas Phys Eng Sci Med 30(3):211–220CrossRefPubMed Keall PJ, Vedam SS, George R, Williamson JF (2007) Respiratory regularity gated 4D CT acquisition: concepts and proof of principle. Australas Phys Eng Sci Med 30(3):211–220CrossRefPubMed
18.
go back to reference Coatney RW (2001) Ultrasound imaging: principles and applications in rodent research. ILAR J 42(3):233–247CrossRefPubMed Coatney RW (2001) Ultrasound imaging: principles and applications in rodent research. ILAR J 42(3):233–247CrossRefPubMed
20.
go back to reference Damen FW, Adelsperger AR, Wilson KE, Goergen CJ (2015) Comparison of traditional and integrated digital anesthetic vaporizers. J Am Assoc Lab Anim Sci 54(6):756–762PubMedPubMedCentral Damen FW, Adelsperger AR, Wilson KE, Goergen CJ (2015) Comparison of traditional and integrated digital anesthetic vaporizers. J Am Assoc Lab Anim Sci 54(6):756–762PubMedPubMedCentral
23.
go back to reference Daugherty A, Cassis L (1999) Chronic angiotensin II infusion promotes atherogenesis in low density lipoprotein receptor -/- mice. Ann N Y Acad Sci 892:108–118CrossRefPubMed Daugherty A, Cassis L (1999) Chronic angiotensin II infusion promotes atherogenesis in low density lipoprotein receptor -/- mice. Ann N Y Acad Sci 892:108–118CrossRefPubMed
25.
go back to reference Folland ED, Parisi AF, Moynihan PF, Jones DR, Feldman CL, Tow DE (1979) Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation 60(4):760–766CrossRefPubMed Folland ED, Parisi AF, Moynihan PF, Jones DR, Feldman CL, Tow DE (1979) Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation 60(4):760–766CrossRefPubMed
26.
go back to reference Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ, Chamber Quantification Writing Group; American Society of Echocardiography’s Guidelines and Standards Committee; European Association of Echocardiography (2005) Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 18(12):1440–1463. https://doi.org/10.1016/j.echo.2005.10.005 CrossRefPubMed Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, Picard MH, Roman MJ, Seward J, Shanewise JS, Solomon SD, Spencer KT, Sutton MS, Stewart WJ, Chamber Quantification Writing Group; American Society of Echocardiography’s Guidelines and Standards Committee; European Association of Echocardiography (2005) Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 18(12):1440–1463. https://​doi.​org/​10.​1016/​j.​echo.​2005.​10.​005 CrossRefPubMed
27.
go back to reference Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L, Flachskampf FA, Foster E, Goldstein SA, Kuznetsova T, Lancellotti P, Muraru D, Picard MH, Rietzschel ER, Rudski L, Spencer KT, Tsang W, Voigt JU (2015) Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr 28(1):1–39.e14. https://doi.org/10.1016/j.echo.2014.10.003 CrossRefPubMed Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L, Flachskampf FA, Foster E, Goldstein SA, Kuznetsova T, Lancellotti P, Muraru D, Picard MH, Rietzschel ER, Rudski L, Spencer KT, Tsang W, Voigt JU (2015) Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr 28(1):1–39.e14. https://​doi.​org/​10.​1016/​j.​echo.​2014.​10.​003 CrossRefPubMed
29.
go back to reference Holzapfel GA (2000) Nonlinear solid mechanics: a continuum approach for engineering. West Sussex: Wiley Holzapfel GA (2000) Nonlinear solid mechanics: a continuum approach for engineering. West Sussex: Wiley
30.
go back to reference Sonesson B, Hansen F, Lanne T (1997) Abdominal aortic aneurysm: a general defect in the vasculature with focal manifestations in the abdominal aorta? J Vasc Surg 26(2):247–254CrossRefPubMed Sonesson B, Hansen F, Lanne T (1997) Abdominal aortic aneurysm: a general defect in the vasculature with focal manifestations in the abdominal aorta? J Vasc Surg 26(2):247–254CrossRefPubMed
31.
go back to reference Ailawadi G, Eliason JL, Upchurch GR Jr (2003) Current concepts in the pathogenesis of abdominal aortic aneurysm. J Vasc Surg 38(3):584–588CrossRefPubMed Ailawadi G, Eliason JL, Upchurch GR Jr (2003) Current concepts in the pathogenesis of abdominal aortic aneurysm. J Vasc Surg 38(3):584–588CrossRefPubMed
32.
go back to reference Phillips EH, Yrineo AA, Schroeder HD, Wilson KE, Cheng JX, Goergen CJ (2015) Morphological and biomechanical differences in the elastase & AngII apoE–/– rodent models of abdominal aortic aneurysms. BioMed Res Int 2015:1–12, Article ID 413189. https://doi.org/10.1155/2015/413189 Phillips EH, Yrineo AA, Schroeder HD, Wilson KE, Cheng JX, Goergen CJ (2015) Morphological and biomechanical differences in the elastase & AngII apoE–/– rodent models of abdominal aortic aneurysms. BioMed Res Int 2015:1–12, Article ID 413189. https://​doi.​org/​10.​1155/​2015/​413189
35.
go back to reference Michael LH, Entman ML, Hartley CJ, Youker KA, Zhu J, Hall SR, Hawkins HK, Berens K, Ballantyne CM (1995) Myocardial ischemia and reperfusion: a murine model. Am J Physiol 269(6 Pt 2):H2147–H2154PubMed Michael LH, Entman ML, Hartley CJ, Youker KA, Zhu J, Hall SR, Hawkins HK, Berens K, Ballantyne CM (1995) Myocardial ischemia and reperfusion: a murine model. Am J Physiol 269(6 Pt 2):H2147–H2154PubMed
Metadata
Title
Cardiac and respiratory-gated volumetric murine ultrasound
Authors
Arvin H. Soepriatna
Frederick W. Damen
Pavlos P. Vlachos
Craig J. Goergen
Publication date
01-05-2018
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 5/2018
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-017-1283-z

Other articles of this Issue 5/2018

The International Journal of Cardiovascular Imaging 5/2018 Go to the issue