Skip to main content
Top
Published in: Critical Care 6/2004

01-01-2004 | Commentary

Can electrophysiological assessments of brain function be useful to the intensive care physician in daily clinical practice?

Author: Pierre C Pandin

Published in: Critical Care | Issue 6/2004

Login to get access

Abstract

Changes in electroencephalogram parameters and auditory event-related potentials, induced by interruption to propofol sedation in intensive care patients, provide a number of electrophysiological measures that can be used to assess neurological function accurately. Studies of electroencephalogram parameters suggest that power spectral estimation, as root mean square power, is more useful and precise than spectral edge frequency 95% in evaluating the functional integrity of the brain. When such parameters are used to evaluate neurological function, in particular the N100 and mismatch negativity components, a precise assessment of a patient's readiness to awaken from a pharmacologically induced coma (such as sedation) can be obtained. In terms of ease of use, however, it is more difficult to establish whether N100 or mismatch negativity is superior.
Literature
1.
go back to reference Yppärilä H, Nunes S, Korkhonen I, Partanen J, Ruokonen E: The effect of interruption of propofol sedation on auditory event-related potentials (ERPs) and electroencephalogram (EEG) in intensive care patients. Crit Care 2004, 8: R483-R490. 10.1186/cc2984PubMedCentralCrossRefPubMed Yppärilä H, Nunes S, Korkhonen I, Partanen J, Ruokonen E: The effect of interruption of propofol sedation on auditory event-related potentials (ERPs) and electroencephalogram (EEG) in intensive care patients. Crit Care 2004, 8: R483-R490. 10.1186/cc2984PubMedCentralCrossRefPubMed
2.
go back to reference Guérit JM: Medical technology assessment of EEG and evoked potentials in intensive care unit. Neurophysiol Clin 1999, 29: 301-317.CrossRefPubMed Guérit JM: Medical technology assessment of EEG and evoked potentials in intensive care unit. Neurophysiol Clin 1999, 29: 301-317.CrossRefPubMed
3.
go back to reference Sneyd R, Samra S, Davidson B, Kishimoto T, Kadoya C, Domino E: Electrophysiological effects of propofol sedation. Anesth Analg 1994, 79: 1151-1158.CrossRefPubMed Sneyd R, Samra S, Davidson B, Kishimoto T, Kadoya C, Domino E: Electrophysiological effects of propofol sedation. Anesth Analg 1994, 79: 1151-1158.CrossRefPubMed
4.
go back to reference Engelhardt W, Friess K, Hartung E, Sold M, Dierks T: EEG and auditory evoked potential P300 compared with psychometric test in assessing vigilance after benzodiazepine sedation and antagonism. Br J Anaesth 1992, 69: 75-80.CrossRefPubMed Engelhardt W, Friess K, Hartung E, Sold M, Dierks T: EEG and auditory evoked potential P300 compared with psychometric test in assessing vigilance after benzodiazepine sedation and antagonism. Br J Anaesth 1992, 69: 75-80.CrossRefPubMed
5.
go back to reference Nuwer M: Assessment of digital EEG, quantitative EEG and brain EEG mapping: report of the American Academy of Neurology and the American Clinical Neurophysiology Society. Neurology 1997,49(1):277-292.CrossRefPubMed Nuwer M: Assessment of digital EEG, quantitative EEG and brain EEG mapping: report of the American Academy of Neurology and the American Clinical Neurophysiology Society. Neurology 1997,49(1):277-292.CrossRefPubMed
6.
go back to reference John ER: Invariant reversible QEEG effects of anesthetics. Conscious Cogn 2001, 10: 165-183. 10.1006/ccog.2001.0507CrossRefPubMed John ER: Invariant reversible QEEG effects of anesthetics. Conscious Cogn 2001, 10: 165-183. 10.1006/ccog.2001.0507CrossRefPubMed
7.
go back to reference Ropcke H, Schwilden H: Interaction of isoflurane and nitrous oxide combination similar for median electroencephalographic frequency and clinical anesthesia. Anesthesiology 1996, 84: 782-788. 10.1097/00000542-199604000-00004CrossRefPubMed Ropcke H, Schwilden H: Interaction of isoflurane and nitrous oxide combination similar for median electroencephalographic frequency and clinical anesthesia. Anesthesiology 1996, 84: 782-788. 10.1097/00000542-199604000-00004CrossRefPubMed
8.
go back to reference Thomsen CE, Prior PF: Quantitative EEG in assessment of anaesthetic depth: comparative study of methodology. Br J Anaesth 1996, 77: 172-178.CrossRefPubMed Thomsen CE, Prior PF: Quantitative EEG in assessment of anaesthetic depth: comparative study of methodology. Br J Anaesth 1996, 77: 172-178.CrossRefPubMed
9.
go back to reference Horn B, Schneider G, Ningler M, Stockmanns G, Kochs E: Identification of EEG parameters that can be used to monitor the full range of anesthesia [abstract]. Anesthesiology 2004, 101: A-329. Horn B, Schneider G, Ningler M, Stockmanns G, Kochs E: Identification of EEG parameters that can be used to monitor the full range of anesthesia [abstract]. Anesthesiology 2004, 101: A-329.
10.
go back to reference Schneider G, Ningler M, Stockmanns G, Nebl C, Kochs E: EEG parameters separate awareness from unconsciousness at loss and return of consciousness [abstract]. Anesthesiology 2004, 101: A-332. Schneider G, Ningler M, Stockmanns G, Nebl C, Kochs E: EEG parameters separate awareness from unconsciousness at loss and return of consciousness [abstract]. Anesthesiology 2004, 101: A-332.
11.
go back to reference Vespa P, Nuwer M, Juhasz C, Alexander M, Nenov V, Martin N, Becker D: Early detection of vasospasm after acute subarachnoid hemorrhage using continuous EEG ICU monitoring. Electroencephalogr Clin Neurophysiol 1997, 103: 607-615. 10.1016/S0013-4694(97)00071-0CrossRefPubMed Vespa P, Nuwer M, Juhasz C, Alexander M, Nenov V, Martin N, Becker D: Early detection of vasospasm after acute subarachnoid hemorrhage using continuous EEG ICU monitoring. Electroencephalogr Clin Neurophysiol 1997, 103: 607-615. 10.1016/S0013-4694(97)00071-0CrossRefPubMed
12.
go back to reference Vespa P, Nuwer M, Nenov V, Ronne-Engstrom E, Hovda DA, Bergsneider M, Kelly D, Martin N, Becker D: Increased incidence and impact of nonconvulsive and convulsive seizures after traumatic brain injury as detected by continuous electroencephalographic monitoring. J Neurosurg 1999, 91: 750-760.PubMedCentralCrossRefPubMed Vespa P, Nuwer M, Nenov V, Ronne-Engstrom E, Hovda DA, Bergsneider M, Kelly D, Martin N, Becker D: Increased incidence and impact of nonconvulsive and convulsive seizures after traumatic brain injury as detected by continuous electroencephalographic monitoring. J Neurosurg 1999, 91: 750-760.PubMedCentralCrossRefPubMed
13.
go back to reference Näätänen R, Picton T: The N1 wave of the human electric and magnetic response to sound: a review and an analysis of the component structure. Psychophysiology 1987, 24: 375-425.CrossRefPubMed Näätänen R, Picton T: The N1 wave of the human electric and magnetic response to sound: a review and an analysis of the component structure. Psychophysiology 1987, 24: 375-425.CrossRefPubMed
14.
go back to reference Näätänen R: The mismatch negativity: a powerful tool for cognitive neuroscience. Ear Hear 1995, 16: 6-18.CrossRefPubMed Näätänen R: The mismatch negativity: a powerful tool for cognitive neuroscience. Ear Hear 1995, 16: 6-18.CrossRefPubMed
15.
go back to reference Fischer C, Morlet D, Bouchet P, Luaute J, Jourdan C, Salford F: Mismatch negativity and late auditory evoked potentials in comatose patients. Clin Neurophysiol 1999, 110: 1601-1610. 10.1016/S1388-2457(99)00131-5CrossRefPubMed Fischer C, Morlet D, Bouchet P, Luaute J, Jourdan C, Salford F: Mismatch negativity and late auditory evoked potentials in comatose patients. Clin Neurophysiol 1999, 110: 1601-1610. 10.1016/S1388-2457(99)00131-5CrossRefPubMed
Metadata
Title
Can electrophysiological assessments of brain function be useful to the intensive care physician in daily clinical practice?
Author
Pierre C Pandin
Publication date
01-01-2004
Publisher
BioMed Central
Published in
Critical Care / Issue 6/2004
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc3011

Other articles of this Issue 6/2004

Critical Care 6/2004 Go to the issue