Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?

Authors: Michael Dahl, Chris Hayes, Bodil Steen Rasmussen, Anders Larsson, Niels H. Secher

Published in: BMC Anesthesiology | Issue 1/2015

Login to get access

Abstract

Background

Whether during spontaneous breathing arterial pressure variations (APV) can detect a volume deficit is not established. We hypothesized that amplification of intra-thoracic pressure oscillations by breathing through resistors would enhance APV to allow identification of a reduced cardiac output (CO). This study tested that hypothesis in healthy volunteers exposed to central hypovolemia by head-up tilt.

Methods

Thirteen healthy volunteers were exposed to central hypovolemia by 45° head-up tilt while breathing through a facemask with 7.5 cmH2O inspiratory and/or expiratory resistors. A brachial arterial catheter was used to measure blood pressure and thus systolic pressure variation (SPV), pulse pressure variation and stroke volume variation . Pulse contour analysis determined stroke volume (SV) and CO and we evaluated whether APV could detect a 10 % decrease in CO.

Results

During head-up tilt SV decreased form 91 (±46) to 55 (±24) mL (mean ± SD) and CO from 5.8 (±2.9) to 4.0 (±1.8) L/min (p < 0.05), while heart rate increased (65 (±11) to 75 (±13) bpm; P < 0.05). Systolic pressure decreased from 127 (±14) to 121 (±13) mmHg during head-up tilt, while SPV tended to increase (from 21 (±15)% to 30 (±13)%). Yet during head-up tilt, a SPV ≥ 37 % predicted a decrease in CO ≥ 10 % with a sensitivity and specificity of 78 % and 100 %, respectively.

Conclusion

In spontaneously breathing healthy volunteers combined inspiratory and expiratory resistors enhance SPV during head-up tilted induced central hypovolemia and allow identifying a 10 % reduction in CO. Applying inspiratory and expiratory resistors might detect a fluid deficit in spontaneously breathing patients.

Trial registration

ClinicalTrials.gov number NCT02549482 Registered September 10th 2015.
Literature
1.
go back to reference Rooke G, Schwid H, Shapira Y. The Effect of Graded Hemorrhage and Intravascular Volume Replacement on Systolic Pressure Variation in Humans During Mecanical and Spontaneous Ventilation. Anesth Analg. 1995;80:925–32.PubMed Rooke G, Schwid H, Shapira Y. The Effect of Graded Hemorrhage and Intravascular Volume Replacement on Systolic Pressure Variation in Humans During Mecanical and Spontaneous Ventilation. Anesth Analg. 1995;80:925–32.PubMed
3.
go back to reference Cecconi M, Hofer C, Teboul J-L, Pettila V, Wilkman E, Molnar Z, Della Rocca G, Aldecoa C, Artigas A, Jog S, Sander M, Spies C, Lefrant J-Y, De Backer D. Fluid challenges in intensive care: the FENICE study. Intensive Care Med. 2015;41:1529–37.CrossRefPubMedPubMedCentral Cecconi M, Hofer C, Teboul J-L, Pettila V, Wilkman E, Molnar Z, Della Rocca G, Aldecoa C, Artigas A, Jog S, Sander M, Spies C, Lefrant J-Y, De Backer D. Fluid challenges in intensive care: the FENICE study. Intensive Care Med. 2015;41:1529–37.CrossRefPubMedPubMedCentral
4.
go back to reference Marik PE, Cavallazzi R. Does the Central Venous Pressure Predict Fluid Responsiveness? An Updated Meta-Analysis and a Plea for Some Common Sense. Crit Care Med. 2013;41:1774–81.CrossRefPubMed Marik PE, Cavallazzi R. Does the Central Venous Pressure Predict Fluid Responsiveness? An Updated Meta-Analysis and a Plea for Some Common Sense. Crit Care Med. 2013;41:1774–81.CrossRefPubMed
5.
go back to reference Secher NH, Van Lieshout JJ. Hypovolaemic Shock. In: Clinical Fluid Therapy in the Perioperative Setting. London, United Kingdom: Cambridge University Press. 2011:166–176. Secher NH, Van Lieshout JJ. Hypovolaemic Shock. In: Clinical Fluid Therapy in the Perioperative Setting. London, United Kingdom: Cambridge University Press. 2011:166–176.
6.
go back to reference Wu Y, Zhou S, Zhou Z, Liu B. A 10 second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness. Crit Care. 2014;18:R108.CrossRefPubMedPubMedCentral Wu Y, Zhou S, Zhou Z, Liu B. A 10 second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness. Crit Care. 2014;18:R108.CrossRefPubMedPubMedCentral
7.
go back to reference De Backer D, Scolletta S. Why do pulse pressure variations fail to predict the response to fluids in acute respiratory distress syndrome patients ventilated with low tidal volume? Crit Care. 2011;15:150.CrossRefPubMedPubMedCentral De Backer D, Scolletta S. Why do pulse pressure variations fail to predict the response to fluids in acute respiratory distress syndrome patients ventilated with low tidal volume? Crit Care. 2011;15:150.CrossRefPubMedPubMedCentral
8.
go back to reference Cecconi M, Monge García MI, Gracia Romero M, Mellinghoff J, Caliandro F, Grounds RM, Rhodes A. The Use of Pulse Pressure Variation and Stroke Volume Variation in Spontaneously Breathing Patients to Assess Dynamic Arterial Elastance and to Predict Arterial Pressure Response to Fluid Administration. Anesth Analg. 2015;120:76–84.CrossRefPubMed Cecconi M, Monge García MI, Gracia Romero M, Mellinghoff J, Caliandro F, Grounds RM, Rhodes A. The Use of Pulse Pressure Variation and Stroke Volume Variation in Spontaneously Breathing Patients to Assess Dynamic Arterial Elastance and to Predict Arterial Pressure Response to Fluid Administration. Anesth Analg. 2015;120:76–84.CrossRefPubMed
9.
go back to reference Feihl F, Broccard AF. Interactions between respiration and systemic hemodynamics. Part I: basic concepts. Intensive Care Med. 2009;35:45–54.CrossRefPubMed Feihl F, Broccard AF. Interactions between respiration and systemic hemodynamics. Part I: basic concepts. Intensive Care Med. 2009;35:45–54.CrossRefPubMed
10.
go back to reference Feihl F, Broccard AF. Interactions between respiration and systemic hemodynamics. Part II: practical implications in critical care. Intensive Care Med. 2009;35:198–205.CrossRefPubMed Feihl F, Broccard AF. Interactions between respiration and systemic hemodynamics. Part II: practical implications in critical care. Intensive Care Med. 2009;35:198–205.CrossRefPubMed
11.
go back to reference Magder S. Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med. 2004;169:151–5.CrossRefPubMed Magder S. Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med. 2004;169:151–5.CrossRefPubMed
12.
go back to reference Michard F, Chemla D, Richard C, Wysocki M, Pinsky MR, Lecarpentier Y, Teboul JL. Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med. 1999;159:935–9.CrossRefPubMed Michard F, Chemla D, Richard C, Wysocki M, Pinsky MR, Lecarpentier Y, Teboul JL. Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med. 1999;159:935–9.CrossRefPubMed
13.
go back to reference Michard F, Teboul J. Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence. Chest. 2002;121:2000–8.CrossRefPubMed Michard F, Teboul J. Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence. Chest. 2002;121:2000–8.CrossRefPubMed
14.
go back to reference Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014;18:650.CrossRefPubMedPubMedCentral Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014;18:650.CrossRefPubMedPubMedCentral
15.
go back to reference Heenen S, De Backer D, Vincent J-L. How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care. 2006;10:R102.CrossRefPubMedPubMedCentral Heenen S, De Backer D, Vincent J-L. How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care. 2006;10:R102.CrossRefPubMedPubMedCentral
16.
go back to reference Teboul J-L, Monnet X. Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity. Curr Opin Crit Care. 2008;14:334–9.CrossRefPubMed Teboul J-L, Monnet X. Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity. Curr Opin Crit Care. 2008;14:334–9.CrossRefPubMed
17.
go back to reference Soubrier S, Saulnier F, Hubert H, Delour P, Lenci H, Onimus T, Nseir S, Durocher A. Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients? Intensive Care Med. 2007;33:1117–24.CrossRefPubMed Soubrier S, Saulnier F, Hubert H, Delour P, Lenci H, Onimus T, Nseir S, Durocher A. Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients? Intensive Care Med. 2007;33:1117–24.CrossRefPubMed
18.
go back to reference Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul J-L. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med. 2006;34:1402–7.CrossRefPubMed Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul J-L. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med. 2006;34:1402–7.CrossRefPubMed
19.
go back to reference Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, Guerin L, Richard C, Teboul J-L. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med. 2013;39:93–100.CrossRefPubMed Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, Guerin L, Richard C, Teboul J-L. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med. 2013;39:93–100.CrossRefPubMed
21.
go back to reference Frost H, Mortensen C, Secher N, Nielsen H. Postoperative volume balance: Does stroke volume increase in Trendelenburg’s position. Clin Physiol Func Imag. 2015. (In press). Frost H, Mortensen C, Secher N, Nielsen H. Postoperative volume balance: Does stroke volume increase in Trendelenburg’s position. Clin Physiol Func Imag. 2015. (In press).
22.
go back to reference Zaniboni M, Formenti P, Umbrello M, Galimberti A, Noto A, Iapichino G. Pulse and systolic pressure variation assessment in partially assisted ventilatory support. J Clin Monit Comput. 2008;22:355–9.CrossRefPubMed Zaniboni M, Formenti P, Umbrello M, Galimberti A, Noto A, Iapichino G. Pulse and systolic pressure variation assessment in partially assisted ventilatory support. J Clin Monit Comput. 2008;22:355–9.CrossRefPubMed
23.
go back to reference Dahl MK, Vistisen ST, Koefoed-Nielsen J, Larsson A. Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study. Crit Care. 2009;13:R39.CrossRefPubMedPubMedCentral Dahl MK, Vistisen ST, Koefoed-Nielsen J, Larsson A. Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study. Crit Care. 2009;13:R39.CrossRefPubMedPubMedCentral
24.
go back to reference Bronzwaer A-SGT, Ouweneel DM, Stok WJ, Westerhof BE, van Lieshout JJ. Arterial Pressure Variation as a Biomarker of Preload Dependency in Spontaneously Breathing Subjects – A Proof of Principle. PLoS One. 2015;10, e0137364.CrossRefPubMedPubMedCentral Bronzwaer A-SGT, Ouweneel DM, Stok WJ, Westerhof BE, van Lieshout JJ. Arterial Pressure Variation as a Biomarker of Preload Dependency in Spontaneously Breathing Subjects – A Proof of Principle. PLoS One. 2015;10, e0137364.CrossRefPubMedPubMedCentral
25.
go back to reference Matzen S, Perko G, Groth S, Friedman DB, Secher NH. Blood volume distribution during head-up tilt induced central hypovolaemia in man. Clin Physiol. 1991;11:411–22.CrossRefPubMed Matzen S, Perko G, Groth S, Friedman DB, Secher NH. Blood volume distribution during head-up tilt induced central hypovolaemia in man. Clin Physiol. 1991;11:411–22.CrossRefPubMed
26.
go back to reference Brigden W, Howarth S, Sharpey-Schafer EP. Postural changes in the peripheral blood-flow of normal subjects with observations on vasovagal fainting reactions as a result of tilting, the lordotic posture, pregnancy and spinal anæsthesia. Clin Sci. 1950;9:79–90.PubMed Brigden W, Howarth S, Sharpey-Schafer EP. Postural changes in the peripheral blood-flow of normal subjects with observations on vasovagal fainting reactions as a result of tilting, the lordotic posture, pregnancy and spinal anæsthesia. Clin Sci. 1950;9:79–90.PubMed
27.
go back to reference Knopp R, Claypool R, Leonardi D. Use of the Tilt Test in Measuring Acute Blood Loss. Ann Emerg Med. 1980;9:29–32. Knopp R, Claypool R, Leonardi D. Use of the Tilt Test in Measuring Acute Blood Loss. Ann Emerg Med. 1980;9:29–32.
28.
go back to reference Wilson TE, Brothers RM, Tollund C, Dawson EA, Nissen P, Yoshiga CC, Jons C, Secher NH, Crandall CG. Effect of thermal stress on Frank-Starling relations in humans. J Physiol. 2009;587:3383–92.CrossRefPubMedPubMedCentral Wilson TE, Brothers RM, Tollund C, Dawson EA, Nissen P, Yoshiga CC, Jons C, Secher NH, Crandall CG. Effect of thermal stress on Frank-Starling relations in humans. J Physiol. 2009;587:3383–92.CrossRefPubMedPubMedCentral
29.
go back to reference Harms MPM, Van Lieshout JJ, Jenstrup M, Pott F, Secher NH. Postural effects on cardiac output and mixed venous oxygen saturation in human. Exp Physiol. 2003;88:611–6.CrossRefPubMed Harms MPM, Van Lieshout JJ, Jenstrup M, Pott F, Secher NH. Postural effects on cardiac output and mixed venous oxygen saturation in human. Exp Physiol. 2003;88:611–6.CrossRefPubMed
30.
go back to reference Bundgaard-Nielsen M, Sørensen H, Dalsgaard M, Rasmussen P, Secher NH. Relationship between stroke volume, cardiac output and filling of the heart during tilt. Acta Anaesthesiol Scand. 2009;53:1324–8.CrossRefPubMed Bundgaard-Nielsen M, Sørensen H, Dalsgaard M, Rasmussen P, Secher NH. Relationship between stroke volume, cardiac output and filling of the heart during tilt. Acta Anaesthesiol Scand. 2009;53:1324–8.CrossRefPubMed
32.
go back to reference Monnet X, Anguel N, Naudin B, Jabot J, Richard C, Teboul J-L. Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices. Crit Care. 2010;14:R109.CrossRefPubMedPubMedCentral Monnet X, Anguel N, Naudin B, Jabot J, Richard C, Teboul J-L. Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices. Crit Care. 2010;14:R109.CrossRefPubMedPubMedCentral
33.
go back to reference Zöllei É, Bertalan V, Németh A, Csábi P, László I, Kaszaki J, Rudas L. Non-invasive detection of hypovolemia or fluid responsiveness in spontaneously breathing subjects. BMC Anesthesiol. 2013;13:40.CrossRefPubMedPubMedCentral Zöllei É, Bertalan V, Németh A, Csábi P, László I, Kaszaki J, Rudas L. Non-invasive detection of hypovolemia or fluid responsiveness in spontaneously breathing subjects. BMC Anesthesiol. 2013;13:40.CrossRefPubMedPubMedCentral
Metadata
Title
Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?
Authors
Michael Dahl
Chris Hayes
Bodil Steen Rasmussen
Anders Larsson
Niels H. Secher
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2015
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-016-0224-z

Other articles of this Issue 1/2015

BMC Anesthesiology 1/2015 Go to the issue