Skip to main content
Top
Published in: BMC Oral Health 1/2023

Open Access 01-12-2023 | CAD and CAM | Research

Evaluation of the masking ability, marginal adaptation, and fracture resistance of screw-retained lithium disilicate implant-supported crowns cemented to titanium bases versus preparable abutments

Authors: Ahmad Waled Mohamad Kordi, Abdallah Ibrahim Salman, Nayrouz Adel Metwally, Mohamed Moataz Khamis

Published in: BMC Oral Health | Issue 1/2023

Login to get access

Abstract

Background

Straight preparable abutments and titanium bases (ti-base) can be used to support single-unit screw-retained lithium disilicate implant-supported restorations. The choice between using both abutments depends on many factors. The purpose of this in vitro study was to compare the masking ability, marginal adaptation, and fracture resistance of screw-retained lithium disilicate implant-supported crowns cemented to straight preparable abutments and ti-bases.

Methods

Twenty laboratory implant analogs (Straumann Bone Level; Straumann AG) were randomly divided into 2 groups (n = 10 each) according to the type of the abutment used. Preparable abutment group and ti-base group. Lithium disilicate crowns were used to restore the specimens. All specimens were subjected to thermocycling (from 5 to 55 °C for 2000 cycles) followed by cyclic loading (120 000 cycles). The vertical marginal gap between the abutment finish line and the most apical part of the crown was measured in (µm) by using a stereomicroscope after cementation and after thermocycling and cyclic loading. A spectrophotometer was used to evaluate the masking ability of the specimens after cementation. The load required to fracture the crowns was measured in Newtons (N) by using a universal testing machine after thermocycling and cyclic loading. The Shapiro-Wilk test of normality was used. The appropriate statistical test was used.

Results

Regarding the masking ability, the color difference (∆E) showed no statistically significant difference between the ti-base group (2.6 ± 0.2) and the preparable abutment group (2.6 ± 0.3) (P = .888). The average of the microgap values (µm) was greater in ti-basegroup after cementation (13.9 ± 9.2) than preparable group (7.63 ± 1.78) with no statistically significant difference between the 2 groups (P = .49). After cyclic loading and thermocycling, the average microgap values (µm) was significantly greater in the ti base group (21.3 ± 7.4) than in preparable group (13.3 ± 1.5) (P = .02). The load required to fracture the specimens was greater in the preparable group (1671.5 ± 143.8) than in the ti-base group (1550.2 ± 157.5) with no statistically significant difference between the 2 groups (P = .089).

Conclusion

The abutments used in the present study did not compromise the masking ability of the screw-retained lithium disilicate implant supported crowns. Moreover, the crowns cemented to preparable abutments had better marginal adaptation and higher fracture resistance when compared to those cemented to ti-bases.

Clinical implications

Straight preparable abutments are considered as an alternative to the ti-bases when restoring single screw-retained lithium disilicate implant-supported crowns with comparable fracture resistance, marginal adaptation, and masking ability.
Literature
1.
go back to reference Fasbinder DJ, Dennison JB, Heys D, Neiva GA. Clinical evaluation of chairside lithium disilicate CAD/CAM crowns. J Am Dent Assoc. 2010;14:10–4.CrossRef Fasbinder DJ, Dennison JB, Heys D, Neiva GA. Clinical evaluation of chairside lithium disilicate CAD/CAM crowns. J Am Dent Assoc. 2010;14:10–4.CrossRef
2.
go back to reference Khamis MM, Zakaria NH. Effect of screw access channel on the fracture rate of lithium 5.Disilicate cement-retained implant-supported posterior crowns. J Prosthet Dent. 2022;127:618–25.CrossRefPubMed Khamis MM, Zakaria NH. Effect of screw access channel on the fracture rate of lithium 5.Disilicate cement-retained implant-supported posterior crowns. J Prosthet Dent. 2022;127:618–25.CrossRefPubMed
3.
go back to reference Khalifa AA, Metwally NA, Khamis MM. Evaluation of debonding force of screw retained lithium disilicate implant supported crowns cemented to abutments of different designs and surface treatments. J Prosthet Dent. 2023. Khalifa AA, Metwally NA, Khamis MM. Evaluation of debonding force of screw retained lithium disilicate implant supported crowns cemented to abutments of different designs and surface treatments. J Prosthet Dent. 2023.
4.
go back to reference Proussaefs P, AlHelal A. The combination prosthesis: a digitally designed retrievable cement- and screw-retained implant-supported prosthesis. J Prosthet Dent. 2018;119:535–9.CrossRefPubMed Proussaefs P, AlHelal A. The combination prosthesis: a digitally designed retrievable cement- and screw-retained implant-supported prosthesis. J Prosthet Dent. 2018;119:535–9.CrossRefPubMed
5.
go back to reference Benakatti V, Sajjanar JA, Acharya AR. Dental Implant Abutments and their selection -. Rev J Evol Med Dent Sci. 2020;10:3053–9. Benakatti V, Sajjanar JA, Acharya AR. Dental Implant Abutments and their selection -. Rev J Evol Med Dent Sci. 2020;10:3053–9.
6.
go back to reference Luthardt R, Weber A, Rudolph H, Schone C, Quaas S, Walter M. Design and production of dental prosthetic restorations: basic research on dental CAD/CAM technology. Int J Comput Dent. 2002;5:165–76.PubMed Luthardt R, Weber A, Rudolph H, Schone C, Quaas S, Walter M. Design and production of dental prosthetic restorations: basic research on dental CAD/CAM technology. Int J Comput Dent. 2002;5:165–76.PubMed
7.
go back to reference Erozan Ç, Ozan O. Evaluation of the precision of different intraoral scanner-computer aided design (CAD) software combinations in digital dentistry. Med Sci Monit. 2020;26:e918529.CrossRefPubMedPubMedCentral Erozan Ç, Ozan O. Evaluation of the precision of different intraoral scanner-computer aided design (CAD) software combinations in digital dentistry. Med Sci Monit. 2020;26:e918529.CrossRefPubMedPubMedCentral
8.
go back to reference Mangano F, Veronesi G. Digital versus analog procedures for the prosthetic restoration of single implants: a randomized controlled trial with 1 year of follow-up. BioMed Res int. 2018;18:1–20. Mangano F, Veronesi G. Digital versus analog procedures for the prosthetic restoration of single implants: a randomized controlled trial with 1 year of follow-up. BioMed Res int. 2018;18:1–20.
9.
go back to reference Pires LA, Novais PM, Araújo VD, Pegoraro LF. Effects of the type and thickness of ceramic, substrate, and cement on the optical color of a lithium disilicate ceramic. J Prosthet Dent. 2017;117:144–9.CrossRefPubMed Pires LA, Novais PM, Araújo VD, Pegoraro LF. Effects of the type and thickness of ceramic, substrate, and cement on the optical color of a lithium disilicate ceramic. J Prosthet Dent. 2017;117:144–9.CrossRefPubMed
10.
go back to reference Niu E, Agustin M, Douglas RD. Color match of machinable lithium disilicate ceramics: Effects of cement color and thickness. J Prosthet Dent. 2014;111:42–50.CrossRefPubMed Niu E, Agustin M, Douglas RD. Color match of machinable lithium disilicate ceramics: Effects of cement color and thickness. J Prosthet Dent. 2014;111:42–50.CrossRefPubMed
11.
go back to reference Chen XD, Hong G, Xing WZ, Wang YN. The influence of resin cements on the final color of ceramic veneers. J Prosthodont Res. 2015;59:172–7.CrossRefPubMed Chen XD, Hong G, Xing WZ, Wang YN. The influence of resin cements on the final color of ceramic veneers. J Prosthodont Res. 2015;59:172–7.CrossRefPubMed
12.
go back to reference Thilagar P, Sampathkumar J, Krishnan CS, Ramakrishnan H, Ramasubramanian H, Azhagarasan NH. Comparative evaluation of the masking ability of lithium disilicate ceramic with different core thickness on the shade match of indirect restorations over metallic substrate: an in vitro study. Contemp Clin Dent. 2019;10:56–63.CrossRefPubMedPubMedCentral Thilagar P, Sampathkumar J, Krishnan CS, Ramakrishnan H, Ramasubramanian H, Azhagarasan NH. Comparative evaluation of the masking ability of lithium disilicate ceramic with different core thickness on the shade match of indirect restorations over metallic substrate: an in vitro study. Contemp Clin Dent. 2019;10:56–63.CrossRefPubMedPubMedCentral
13.
go back to reference Vohra F, Alnajashi S, Aljardi A, Al Deeb M, Al Deeb L, Al Ahdal K, et al. Color masking ability of lithium disilicate ceramic for titanium alloy implant abutments. J Biomater Tissue Eng. 2020;10:852–7.CrossRef Vohra F, Alnajashi S, Aljardi A, Al Deeb M, Al Deeb L, Al Ahdal K, et al. Color masking ability of lithium disilicate ceramic for titanium alloy implant abutments. J Biomater Tissue Eng. 2020;10:852–7.CrossRef
14.
go back to reference Lee KB, Park CW, Kim KH, Kwon TY. Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems. Dent Mater J. 2008;27:422–6.CrossRefPubMed Lee KB, Park CW, Kim KH, Kwon TY. Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems. Dent Mater J. 2008;27:422–6.CrossRefPubMed
15.
go back to reference Keith SE, Miller BH, Woody RD, et al. Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments. Int J Oral Maxillofac Implants. 1999;14:369–78.PubMed Keith SE, Miller BH, Woody RD, et al. Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments. Int J Oral Maxillofac Implants. 1999;14:369–78.PubMed
16.
go back to reference Elsayed S, Elbanna K. Effect of different fabrication materials and techniques on the retention of implant meso-structures to Ti-base abutments. Egypt Dent J. 2021;67:2567–85.CrossRef Elsayed S, Elbanna K. Effect of different fabrication materials and techniques on the retention of implant meso-structures to Ti-base abutments. Egypt Dent J. 2021;67:2567–85.CrossRef
17.
go back to reference Zhang Y, Mai Z, Barani A, Bush M, Lawn B. Fracture-resistant monolithic dental crowns. Dent Mater J. 2016;32:442–9.CrossRef Zhang Y, Mai Z, Barani A, Bush M, Lawn B. Fracture-resistant monolithic dental crowns. Dent Mater J. 2016;32:442–9.CrossRef
18.
go back to reference Khalifa AE, Mostafa D, Khamis MM. Influence of screw access channel on all ceramic cement-retained implant-supported posterior crowns. Int J Sci Res. 2016;5:2252–8. Khalifa AE, Mostafa D, Khamis MM. Influence of screw access channel on all ceramic cement-retained implant-supported posterior crowns. Int J Sci Res. 2016;5:2252–8.
19.
go back to reference Hussien AN, Rayyan MM, Sayed NM, Segaan LG, Goodacre CJ, Kattadiyil MT. Effect of screw-access channels on the fracture resistance of 3 types of ceramic implant-supported crowns. J Prosthet Dent. 2016;116:214–20.CrossRefPubMed Hussien AN, Rayyan MM, Sayed NM, Segaan LG, Goodacre CJ, Kattadiyil MT. Effect of screw-access channels on the fracture resistance of 3 types of ceramic implant-supported crowns. J Prosthet Dent. 2016;116:214–20.CrossRefPubMed
20.
go back to reference Hey J, Kasaliyska M, Kiesow A, Schweyen R, Arnold C. Retentive force of glass-ceramic soldered customized Zirconia abutment copings with prefabricated titanium bases. Materials. 2020;13:31–93.CrossRef Hey J, Kasaliyska M, Kiesow A, Schweyen R, Arnold C. Retentive force of glass-ceramic soldered customized Zirconia abutment copings with prefabricated titanium bases. Materials. 2020;13:31–93.CrossRef
21.
go back to reference Mohamed MR, Abdel Kader SH, Aboushady YH, El-latif A, Mona M. Biaxial flexural strength of un-shaded and shaded monolithic translucent zirconia. Alex Dent J. 2018;43:69–73.CrossRef Mohamed MR, Abdel Kader SH, Aboushady YH, El-latif A, Mona M. Biaxial flexural strength of un-shaded and shaded monolithic translucent zirconia. Alex Dent J. 2018;43:69–73.CrossRef
22.
go back to reference Kotz S, Balakrishnan N, Read CB, Vidakovic B. Encyclopedia of statistical sciences. 2nd ed. Hoboken, NJ: Wiley-Interscience; 2006. pp. 981–9. Kotz S, Balakrishnan N, Read CB, Vidakovic B. Encyclopedia of statistical sciences. 2nd ed. Hoboken, NJ: Wiley-Interscience; 2006. pp. 981–9.
23.
go back to reference Thoma DS, Ioannidis A, Fehmer V, Michelotti G, Jung RE, Sailer I. Threshold values for the perception of color changes in human teeth. Int J Periodontics Restorative Dent. 2016;36:777–83.CrossRefPubMed Thoma DS, Ioannidis A, Fehmer V, Michelotti G, Jung RE, Sailer I. Threshold values for the perception of color changes in human teeth. Int J Periodontics Restorative Dent. 2016;36:777–83.CrossRefPubMed
24.
go back to reference Sailer I, Fehmer V, Ioannidis A, Hämmerle CH, Thoma DS. Threshold value for the perception of color changes of human gingiva. Int J Periodontics Restorative Dent. 2014;34:757–62.CrossRefPubMed Sailer I, Fehmer V, Ioannidis A, Hämmerle CH, Thoma DS. Threshold value for the perception of color changes of human gingiva. Int J Periodontics Restorative Dent. 2014;34:757–62.CrossRefPubMed
Metadata
Title
Evaluation of the masking ability, marginal adaptation, and fracture resistance of screw-retained lithium disilicate implant-supported crowns cemented to titanium bases versus preparable abutments
Authors
Ahmad Waled Mohamad Kordi
Abdallah Ibrahim Salman
Nayrouz Adel Metwally
Mohamed Moataz Khamis
Publication date
01-12-2023
Publisher
BioMed Central
Keyword
CAD and CAM
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-03281-8

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue