Open Access 25-04-2024 | Brain Death | Original work

Apnea Testing on Conventional Mechanical Ventilation During Brain Death Evaluation

Authors: Rameez Ali Merchant, Shahid Nafees Ahmad, Bradley Haddix, Craig Andrew Williamson, Teresa Lee Jacobs, Tarun Deep Singh, Andrew M. Nguyen, Venkatakrishna Rajajee

Published in: Neurocritical Care

Login to get access

Abstract

Introduction

The use of continuous positive airway pressure has been shown to improve the tolerance of the apnea test, a critical component of brain death evaluation. The ability to deactivate the apnea backup setting has made apnea testing possible using several conventional mechanical ventilators. Our goal was to evaluate the safety and efficacy of apnea testing performed on mechanical ventilation, compared with the oxygen insufflation technique, for the determination of brain death.

Methods

This was a retrospective study. In 2016, our institution approved a change in policy to permit apnea testing on conventional mechanical ventilation. We examined the records of consecutive adults who underwent apnea testing as part of the brain death evaluation process between 2016 and 2022. Using an apnea test technique was decided at the discretion of the attending physician. Outcomes were successful apnea test and the occurrence of patient instability during the test. This included oxygen desaturation (SpO2) < 90%, hypotension (mean arterial pressure < 65 mm Hg despite titration of vasopressor), cardiac arrhythmia, pneumothorax, and cardiac arrest.

Results

Ninety-two adult patients underwent apnea testing during the study period: 58 (63%) with mechanical ventilation, 32 (35%) with oxygen insufflation, and 2 (2%) lacked documentation of technique. Apnea tests could not be completed successfully in 3 of 92 (3%) patients—two patients undergoing the oxygen insufflation technique (one patient with hypoxemia and one patient with hypotension) and one patient on mechanical ventilation (aborted for hemodynamic instability). Hypoxemia occurred in 4 of 32 (12.5%) patients with oxygen insufflation and in zero patients on mechanical ventilation (p = 0.01). Hypotension occurred during 3 of 58 (5%) tests with mechanical ventilation and 4 of 32 (12.5%) tests with oxygen insufflation (p = 0.24). In multivariate analysis, the use of oxygen insufflation was an independent predictor of patient instability during the apnea test (odds ratio 37.74, 95% confidence interval 2.74–520.14).

Conclusions

Apnea testing on conventional mechanical ventilation is feasible and offers several potential advantages over other techniques.
Literature
1.
go back to reference Greer DM, Kirschen MP, Lewis A, et al. Pediatric and adult brain death/death by neurologic criteria consensus guideline: report of the AAN Guidelines Subcommittee, AAP, CNS, and SCCM. Neurology. 2023;101:1112–32.CrossRefPubMed Greer DM, Kirschen MP, Lewis A, et al. Pediatric and adult brain death/death by neurologic criteria consensus guideline: report of the AAN Guidelines Subcommittee, AAP, CNS, and SCCM. Neurology. 2023;101:1112–32.CrossRefPubMed
2.
go back to reference Busl KM, Lewis A, Varelas PN. Apnea testing for the determination of brain death: a systematic scoping review. Neurocrit Care. 2021;34(2):608–20.CrossRefPubMed Busl KM, Lewis A, Varelas PN. Apnea testing for the determination of brain death: a systematic scoping review. Neurocrit Care. 2021;34(2):608–20.CrossRefPubMed
3.
go back to reference Datar S, Fugate J, Rabinstein A, Couillard P, Wijdicks EF. Completing the apnea test: decline in complications. Neurocrit Care. 2014;21(3):392–6.CrossRefPubMed Datar S, Fugate J, Rabinstein A, Couillard P, Wijdicks EF. Completing the apnea test: decline in complications. Neurocrit Care. 2014;21(3):392–6.CrossRefPubMed
6.
go back to reference Bar-Joseph G, Bar-Lavie Y, Zonis Z. Tension pneumothorax during apnea testing for the determination of brain death. Anesthesiology. 1998;89(5):1250–1.CrossRefPubMed Bar-Joseph G, Bar-Lavie Y, Zonis Z. Tension pneumothorax during apnea testing for the determination of brain death. Anesthesiology. 1998;89(5):1250–1.CrossRefPubMed
7.
go back to reference Kramer AH, Couillard P, Bader R, et al. Prevention of hypoxemia during apnea testing: a comparison of oxygen insufflation and continuous positive airway pressure. Neurocrit Care. 2017;27(1):60–7.CrossRefPubMed Kramer AH, Couillard P, Bader R, et al. Prevention of hypoxemia during apnea testing: a comparison of oxygen insufflation and continuous positive airway pressure. Neurocrit Care. 2017;27(1):60–7.CrossRefPubMed
8.
go back to reference Levesque S, Lessard MR, Nicole PC, et al. Efficacy of a T-piece system and a continuous positive airway pressure system for apnea testing in the diagnosis of brain death. Crit Care Med. 2006;34(8):2213–6.CrossRefPubMed Levesque S, Lessard MR, Nicole PC, et al. Efficacy of a T-piece system and a continuous positive airway pressure system for apnea testing in the diagnosis of brain death. Crit Care Med. 2006;34(8):2213–6.CrossRefPubMed
9.
go back to reference Solek-Pastuszka J, Biernawska J, Iwanczuk W, et al. Comparison of two apnea test methods, oxygen insufflation and continuous positive airway pressure during diagnosis of brain death: final report. Neurocrit Care. 2019;30(2):348–54.CrossRefPubMed Solek-Pastuszka J, Biernawska J, Iwanczuk W, et al. Comparison of two apnea test methods, oxygen insufflation and continuous positive airway pressure during diagnosis of brain death: final report. Neurocrit Care. 2019;30(2):348–54.CrossRefPubMed
10.
go back to reference Greer DM, Shemie SD, Lewis A, et al. Determination of Brain death/death by neurologic criteria: the world brain death project. JAMA. 2020;324(11):1078–97.CrossRefPubMed Greer DM, Shemie SD, Lewis A, et al. Determination of Brain death/death by neurologic criteria: the world brain death project. JAMA. 2020;324(11):1078–97.CrossRefPubMed
11.
go back to reference Force ADT, Ranieri VM, Rubenfeld GD, et al. Acute respiratory distress syndrome: the Berlin definition. JAMA. 2012;307(23):2526–33. Force ADT, Ranieri VM, Rubenfeld GD, et al. Acute respiratory distress syndrome: the Berlin definition. JAMA. 2012;307(23):2526–33.
12.
go back to reference Park J, Lee YJ, Hong KS. Proposed safe apnea test using positive end-expiratory pressure valve and short-term blood gas analysis: observational study. Medicine (Baltimore). 2019;98(19): e15602.CrossRefPubMed Park J, Lee YJ, Hong KS. Proposed safe apnea test using positive end-expiratory pressure valve and short-term blood gas analysis: observational study. Medicine (Baltimore). 2019;98(19): e15602.CrossRefPubMed
13.
go back to reference Giani M, Scaravilli V, Colombo SM, et al. Apnea test during brain death assessment in mechanically ventilated and ECMO patients. Intensive Care Med. 2016;42(1):72–81.CrossRefPubMed Giani M, Scaravilli V, Colombo SM, et al. Apnea test during brain death assessment in mechanically ventilated and ECMO patients. Intensive Care Med. 2016;42(1):72–81.CrossRefPubMed
14.
go back to reference Radaideh Y, Garg R, Abdalla AA, et al. Challenges in brain death determination and apnea testing for patients with COVID-19. J Stroke Cerebrovasc Dis. 2020;29(12): 105419.CrossRefPubMedPubMedCentral Radaideh Y, Garg R, Abdalla AA, et al. Challenges in brain death determination and apnea testing for patients with COVID-19. J Stroke Cerebrovasc Dis. 2020;29(12): 105419.CrossRefPubMedPubMedCentral
15.
go back to reference Truog RD, Tasker RC. COUNTERPOINT: should informed consent be required for apnea testing in patients with suspected brain death? Yes. Chest. 2017;152(4):702–4.CrossRefPubMed Truog RD, Tasker RC. COUNTERPOINT: should informed consent be required for apnea testing in patients with suspected brain death? Yes. Chest. 2017;152(4):702–4.CrossRefPubMed
16.
go back to reference Russell JA, Epstein LG, Greer DM, et al. Brain death, the determination of brain death, and member guidance for brain death accommodation requests: AAN position statement. Neurology. 2019;92(5):228–32.CrossRefPubMed Russell JA, Epstein LG, Greer DM, et al. Brain death, the determination of brain death, and member guidance for brain death accommodation requests: AAN position statement. Neurology. 2019;92(5):228–32.CrossRefPubMed
Metadata
Title
Apnea Testing on Conventional Mechanical Ventilation During Brain Death Evaluation
Authors
Rameez Ali Merchant
Shahid Nafees Ahmad
Bradley Haddix
Craig Andrew Williamson
Teresa Lee Jacobs
Tarun Deep Singh
Andrew M. Nguyen
Venkatakrishna Rajajee
Publication date
25-04-2024
Publisher
Springer US
Published in
Neurocritical Care
Print ISSN: 1541-6933
Electronic ISSN: 1556-0961
DOI
https://doi.org/10.1007/s12028-024-01990-8