Skip to main content
Top
Published in: International Ophthalmology 1/2024

01-12-2024 | Blepharoplasty | Original Paper

Evaluation of early period changes in intraocular pressure, ocular biometry and anterior segment after upper eyelid blepharoplasty

Authors: Hakan Koc, Serkan Ozen, Ugur Bayram, Ali Kanik

Published in: International Ophthalmology | Issue 1/2024

Login to get access

Abstract

Purpose

To investigate the acute effects of upper eyelid blepharoplasty on intraocular pressure (IOP) and ocular biometric parameters.

Method

This prospective cross sectional study examined the eyes of 49 patients with dermatochalasis. Following a detailed ophthalmological examination, corneal topography was used to evaluate the eyes mesopic and photopic pupil diameter, anterior chamber depth, and corneal astigmatism on the day of surgery and on days first and seventh postoperatively. Ocular biometry was used to assess axial length and intraocular lens power. Goldmann applanation tonometry was used to measure intraocular pressure.

Results

Forty-nine eyes (26 males and 23 females) of 49 patients aged between 44 and 76 years (mean 61 ± 7.9) were included in our study. The mean anterior chamber depth (ACD) was 2.90 ± 0.37 mm preoperatively, 3.00 ± 0.29 mm at postoperative day first, and 3.04 ± 0.29 mm at postoperative day seventh, and the increase in anterior chamber depth was statistically significant (p < 0.001). The mean astigmatism values were measured as preoperative 0.73 ± 0.69 D, postoperative first day 0.93 ± 0.81 D, and postoperative seventh day 1.26 ± 0.90 D. The increase in astigmatism values was statistically significant (p < 0.001). The mean pupil diameter measurements in the mesopic environment were 4.20 ± 0.61 mm preoperatively, 4.40 ± 0.59 mm on the first postoperative day, and 4.39 ± 0.57 mm on the seventh postoperative day, and there was a statistically significant difference between the three measurements (p = 0.03). The mean IOP measurements of the patients were 15.91 ± 3.51 mmHg preoperatively, 16.81 ± 3.36 mmHg on the first postoperative day, and 16.97 ± 3.13 mmHg on the seventh postoperative day. The increase between these three measurements was statistically significant (p = 0.013).

Conclusion

This study includes important insights into the potential acute phase impact of blepharoplasty surgery on ocular findings. Patients undergoing upper eyelid surgery should be informed about the possible change in ocular biometric parameters, intraocular pressure, and pupil diameter.
Literature
5.
6.
11.
go back to reference Haverals K, Augustinus A, Hondeghem K (2010) Bilateral acute angle-closure glaucoma after blepharoplasty. Bull Soc Belge Ophtalmol 316:59–61 Haverals K, Augustinus A, Hondeghem K (2010) Bilateral acute angle-closure glaucoma after blepharoplasty. Bull Soc Belge Ophtalmol 316:59–61
16.
go back to reference Brown MS, Siegel IM, Lisman RD (1999) Prospective analysis of changes in corneal topography after upper eyelid surgery. Ophthal Plast Reconstr Surg 15(6):378–383CrossRefPubMed Brown MS, Siegel IM, Lisman RD (1999) Prospective analysis of changes in corneal topography after upper eyelid surgery. Ophthal Plast Reconstr Surg 15(6):378–383CrossRefPubMed
Metadata
Title
Evaluation of early period changes in intraocular pressure, ocular biometry and anterior segment after upper eyelid blepharoplasty
Authors
Hakan Koc
Serkan Ozen
Ugur Bayram
Ali Kanik
Publication date
01-12-2024
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 1/2024
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-024-02935-y

Other articles of this Issue 1/2024

International Ophthalmology 1/2024 Go to the issue