Skip to main content
Top
Published in: Forensic Science, Medicine and Pathology 1/2021

01-03-2021 | Biomarkers | Original Article

Electrical weapons and rhabdomyolysis

Authors: Mark W. Kroll, Klaus K. Witte, Mollie B. Ritter, Sebastian N. Kunz, Richard M. Luceri, John C. Criscione

Published in: Forensic Science, Medicine and Pathology | Issue 1/2021

Login to get access

Abstract

It has been suggested that an application of a conducted electrical weapon (CEW) might cause muscle injury such as rhabdomyolysis and an acute inflammatory response. We explored this hypothesis by testing the effects of electrical weapons on circulating markers of inflammation and muscle damage. In a prospective study, 29 volunteers received a full-trunk 5-s TASER® X26(E) CEW exposure. Venous blood samples were taken before, 5 min after, and at 24 h following the discharge. We tested for changes in serum levels of C-reactive protein (CRP), alkaline phosphatase (ALP), myoglobin, albumin, globulin, albumin/globulin ratio, aspartate and alanine aminotransferase, creatine kinase, total protein, bilirubin, and lactic acid dehydrogenase. Uncorrected CRP and myoglobin levels were lower in the immediate post exposure period (CRP levels 1.44 ± 1.39 v 1.43 ± 1.32 mg/L; p = 0.046 and myoglobin 36.8 ± 11.9 v 36.1 ± 13.9 μg/L; p = 0.0019) but these changes were not significant after correction for multiple comparisons. There were no changes in other biomarkers. At 24 h, CRP levels had decreased by 30% to 1.01 ± 0.80 mg/L (p = 0.001 from baseline). ALP was unchanged immediately after the CEW application but was reduced by 5% from baseline (66.2 ± 16.1 to 62.7 ± 16.1 IU/L; p = 0.0003) at 24 h. No other biomarkers were different from baseline at 24 h. A full-trunk electrical weapon exposure did not lead to clinically significant changes in the acute phase protein levels or changes in measures of muscle cellular injury. We found no biomarker evidence of rhabdomyolysis.
Literature
1.
go back to reference Vilke GM, Chan TC. Less lethal technology: medical issues. Policing. 2007;30:341–57.CrossRef Vilke GM, Chan TC. Less lethal technology: medical issues. Policing. 2007;30:341–57.CrossRef
2.
go back to reference White MD, Ready J. The TASER as a less lethal force alternative: findings on use and effectiveness in a large metropolitan police agency. Police Q. 2007;10:170–91.CrossRef White MD, Ready J. The TASER as a less lethal force alternative: findings on use and effectiveness in a large metropolitan police agency. Police Q. 2007;10:170–91.CrossRef
3.
go back to reference MacDonald JM, Kaminski RJ, Smith MR. The effect of less-lethal weapons on injuries in police use-of-force events. Am J Public Health. 2009;99:2268–74.CrossRef MacDonald JM, Kaminski RJ, Smith MR. The effect of less-lethal weapons on injuries in police use-of-force events. Am J Public Health. 2009;99:2268–74.CrossRef
4.
go back to reference Taylor B, Woods DJ. Injuries to officers and suspects in police use-of-force cases: a quasi-experimental evaluation. Police Q. 2010;13:260–89.CrossRef Taylor B, Woods DJ. Injuries to officers and suspects in police use-of-force cases: a quasi-experimental evaluation. Police Q. 2010;13:260–89.CrossRef
5.
go back to reference Kroll M, Brave M, Pratt H, Witte K, Kunz S, Luceri R. Benefits, risks, and myths of TASER® handheld electrical weapons. Human Factors Mech Eng Defense Safety. 2019;3:7.CrossRef Kroll M, Brave M, Pratt H, Witte K, Kunz S, Luceri R. Benefits, risks, and myths of TASER® handheld electrical weapons. Human Factors Mech Eng Defense Safety. 2019;3:7.CrossRef
6.
go back to reference Ferdik FV, Kaminski RJ, Cooney MD, Sevigny EL. The influence of agency policies on conducted energy device use and police use of lethal force. Police Q. 2014;17:328–58.CrossRef Ferdik FV, Kaminski RJ, Cooney MD, Sevigny EL. The influence of agency policies on conducted energy device use and police use of lethal force. Police Q. 2014;17:328–58.CrossRef
7.
go back to reference Kroll MW, Adamec J, Wetli CV, Williams HE. Fatal traumatic brain injury with electrical weapon falls. J Forensic Legal Med. 2016;43:12–9.CrossRef Kroll MW, Adamec J, Wetli CV, Williams HE. Fatal traumatic brain injury with electrical weapon falls. J Forensic Legal Med. 2016;43:12–9.CrossRef
8.
go back to reference Kroll M, Ritter M, Williams H. Fatal and non-fatal burn injuries with electrical weapons and explosive fumes. J Forensic Legal Med. 2017;50:6–11.CrossRef Kroll M, Ritter M, Williams H. Fatal and non-fatal burn injuries with electrical weapons and explosive fumes. J Forensic Legal Med. 2017;50:6–11.CrossRef
9.
go back to reference Kroll MW, Ritter MB, Kennedy EA, Silverman NK, Shinder R, Brave MA, et al. Eye injuries from electrical weapon probes: incidents, prevalence, and legal implications. J Forensic Legal Med. 2018;55:52–7.CrossRef Kroll MW, Ritter MB, Kennedy EA, Silverman NK, Shinder R, Brave MA, et al. Eye injuries from electrical weapon probes: incidents, prevalence, and legal implications. J Forensic Legal Med. 2018;55:52–7.CrossRef
10.
go back to reference Gapsis BC, Hoang A, Nazari K, Morcos M. Ocular manifestations of TASER-induced trauma. Trauma Case Rep. 2017;12:4–7.CrossRef Gapsis BC, Hoang A, Nazari K, Morcos M. Ocular manifestations of TASER-induced trauma. Trauma Case Rep. 2017;12:4–7.CrossRef
11.
go back to reference Gleason JB, Ahmad I. TASER((R)) electronic control device-induced rhabdomyolysis and renal failure: a case report. J Clin Diagn Res. 2015;9:HD01–2.PubMedPubMedCentral Gleason JB, Ahmad I. TASER((R)) electronic control device-induced rhabdomyolysis and renal failure: a case report. J Clin Diagn Res. 2015;9:HD01–2.PubMedPubMedCentral
12.
go back to reference Sanford JM, Jacobs GJ, Roe EJ, Terndrup TE. Two patients subdued with a TASER(R) device: cases and review of complications. J Emerg Med. 2011;40:28–32.CrossRef Sanford JM, Jacobs GJ, Roe EJ, Terndrup TE. Two patients subdued with a TASER(R) device: cases and review of complications. J Emerg Med. 2011;40:28–32.CrossRef
13.
go back to reference Ho JD, Dawes DM. TASER device-induced rhabdomyolysis is unlikely. J Emerg Med. 2011;40:68–9 author reply 69.CrossRef Ho JD, Dawes DM. TASER device-induced rhabdomyolysis is unlikely. J Emerg Med. 2011;40:68–9 author reply 69.CrossRef
14.
go back to reference Dawes DM, Ho JD, Sweeney JD, Lundin EJ, Kunz SN, Miner JR. The effect of an electronic control device on muscle injury as determined by creatine kinase enzyme. Forensic Sci Med Pathol. 2011;7:3–8.CrossRef Dawes DM, Ho JD, Sweeney JD, Lundin EJ, Kunz SN, Miner JR. The effect of an electronic control device on muscle injury as determined by creatine kinase enzyme. Forensic Sci Med Pathol. 2011;7:3–8.CrossRef
15.
go back to reference Kunz SN, Calkins H, Adamec J, Kroll MW. Cardiac and skeletal muscle effects of electrical weapons: a review of human and animal studies. Forensic Sci Med Pathol. 2018;14:358–66.CrossRef Kunz SN, Calkins H, Adamec J, Kroll MW. Cardiac and skeletal muscle effects of electrical weapons: a review of human and animal studies. Forensic Sci Med Pathol. 2018;14:358–66.CrossRef
16.
go back to reference Ho JD, Miner JR, Lakireddy DR, Bultman LL, Heegaard WG. Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med. 2006;13:589–95.CrossRef Ho JD, Miner JR, Lakireddy DR, Bultman LL, Heegaard WG. Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med. 2006;13:589–95.CrossRef
17.
go back to reference Ho J, Dawes D, Miner J, Kunz S, Nelson R, Sweeney J. Conducted electrical weapon incapacitation during a goal-directed task as a function of probe spread. Forensic Sci Med Pathol. 2012;8:358–66.CrossRef Ho J, Dawes D, Miner J, Kunz S, Nelson R, Sweeney J. Conducted electrical weapon incapacitation during a goal-directed task as a function of probe spread. Forensic Sci Med Pathol. 2012;8:358–66.CrossRef
18.
go back to reference Jauchem JR, Seaman RL, Fines DA. Survival of anesthetized Sus scrofa after cycling (7-second on/3-second off) exposures to an electronic control device for 3 minutes. Am J Forensic Med Pathol. 2011;32:124–30.CrossRef Jauchem JR, Seaman RL, Fines DA. Survival of anesthetized Sus scrofa after cycling (7-second on/3-second off) exposures to an electronic control device for 3 minutes. Am J Forensic Med Pathol. 2011;32:124–30.CrossRef
19.
go back to reference Jauchem JR, Bernhard JA, Cerna CZ, Lim TY, Seaman RL, Tarango M. Effects of a TASER conducted energy weapon on the circulating red-blood-cell population and other factors in Sus scrofa. Forensic Sci Med Pathol. 2013;9:308–20.CrossRef Jauchem JR, Bernhard JA, Cerna CZ, Lim TY, Seaman RL, Tarango M. Effects of a TASER conducted energy weapon on the circulating red-blood-cell population and other factors in Sus scrofa. Forensic Sci Med Pathol. 2013;9:308–20.CrossRef
20.
go back to reference Weibrecht K, Dayno M, Darling C, Bird SB. Liver aminotransferases are elevated with rhabdomyolysis in the absence of significant liver injury. J Med Toxicol. 2010;6:294–300.CrossRef Weibrecht K, Dayno M, Darling C, Bird SB. Liver aminotransferases are elevated with rhabdomyolysis in the absence of significant liver injury. J Med Toxicol. 2010;6:294–300.CrossRef
21.
go back to reference Vladutiu AO, Venuto RC. Creatine kinase MB and lactate dehydrogenase 5 isoenzymes in rhabdomyolysis. Clin Chem. 1977;23:1366.CrossRef Vladutiu AO, Venuto RC. Creatine kinase MB and lactate dehydrogenase 5 isoenzymes in rhabdomyolysis. Clin Chem. 1977;23:1366.CrossRef
22.
go back to reference Rudberg A, Magnusson P, Larsson L, Joborn H. Serum isoforms of bone alkaline phosphatase increase during physical exercise in women. Calcif Tissue Int. 2000;66:342–7.CrossRef Rudberg A, Magnusson P, Larsson L, Joborn H. Serum isoforms of bone alkaline phosphatase increase during physical exercise in women. Calcif Tissue Int. 2000;66:342–7.CrossRef
23.
go back to reference Gulmez O, Ertan C, Yildirir A, Konas D, Bal U, Aydinalp A, et al. C-reactive protein levels increase after exercise testing in patients with increased platelet reactivity. Coron Artery Dis. 2007;18:437–42.CrossRef Gulmez O, Ertan C, Yildirir A, Konas D, Bal U, Aydinalp A, et al. C-reactive protein levels increase after exercise testing in patients with increased platelet reactivity. Coron Artery Dis. 2007;18:437–42.CrossRef
24.
go back to reference Segal O, Behrbalk E, Shapira I, Otremsky I, Berliner S, Halpern P, et al. Timing of C-reactive protein increment in acute traumatic stress: relevance for CRP determinations in acute cardiovascular events. Stress Health: J Int Soc Investigat Stress. 2008;24:281–5.CrossRef Segal O, Behrbalk E, Shapira I, Otremsky I, Berliner S, Halpern P, et al. Timing of C-reactive protein increment in acute traumatic stress: relevance for CRP determinations in acute cardiovascular events. Stress Health: J Int Soc Investigat Stress. 2008;24:281–5.CrossRef
25.
go back to reference Kunz SN, Calkins HG, Adamec J, Kroll MW. Adrenergic and metabolic effects of electrical weapons: review and meta-analysis of human data. Int J Legal Med. 2018;132:1469–75.CrossRef Kunz SN, Calkins HG, Adamec J, Kroll MW. Adrenergic and metabolic effects of electrical weapons: review and meta-analysis of human data. Int J Legal Med. 2018;132:1469–75.CrossRef
27.
go back to reference Kroll MW, Perkins PE, Panescu D. Electric fence standards comport with human data and AC limits. Conf Proc IEEE EMBC. 2015;37:1343–8. Kroll MW, Perkins PE, Panescu D. Electric fence standards comport with human data and AC limits. Conf Proc IEEE EMBC. 2015;37:1343–8.
29.
go back to reference Nimunkar AJ, Webster JG. Safety of pulsed electric devices. Physiol Meas. 2009;30:101–14.CrossRef Nimunkar AJ, Webster JG. Safety of pulsed electric devices. Physiol Meas. 2009;30:101–14.CrossRef
30.
31.
go back to reference Chiles BD, Nerheim MH, Brave MA, Panescu D, Kroll MW. Electrical weapon charge delivery with arcing. Conf Proc IEEE Eng Med Biol Soc. 2018;2018:2234–9. Chiles BD, Nerheim MH, Brave MA, Panescu D, Kroll MW. Electrical weapon charge delivery with arcing. Conf Proc IEEE Eng Med Biol Soc. 2018;2018:2234–9.
32.
go back to reference Brewer J, Kroll M. Field statistics overview. In: Kroll M, Ho J, editors. TASER conducted electrical weapons: physiology, pathology, and law. New York City: Springer-Kluwer; 2009. Brewer J, Kroll M. Field statistics overview. In: Kroll M, Ho J, editors. TASER conducted electrical weapons: physiology, pathology, and law. New York City: Springer-Kluwer; 2009.
33.
go back to reference Bozeman WP, Hauda WE 2nd, Heck JJ, Graham DD Jr, Martin BP, Winslow JE. Safety and injury profile of conducted electrical weapons used by law enforcement officers against criminal suspects. Ann Emerg Med. 2009;53:480–9.CrossRef Bozeman WP, Hauda WE 2nd, Heck JJ, Graham DD Jr, Martin BP, Winslow JE. Safety and injury profile of conducted electrical weapons used by law enforcement officers against criminal suspects. Ann Emerg Med. 2009;53:480–9.CrossRef
Metadata
Title
Electrical weapons and rhabdomyolysis
Authors
Mark W. Kroll
Klaus K. Witte
Mollie B. Ritter
Sebastian N. Kunz
Richard M. Luceri
John C. Criscione
Publication date
01-03-2021
Publisher
Springer US
Keyword
Biomarkers
Published in
Forensic Science, Medicine and Pathology / Issue 1/2021
Print ISSN: 1547-769X
Electronic ISSN: 1556-2891
DOI
https://doi.org/10.1007/s12024-020-00311-7

Other articles of this Issue 1/2021

Forensic Science, Medicine and Pathology 1/2021 Go to the issue