Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 11/2012

Open Access 01-11-2012 | Knee

Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction

Authors: Stephan Frosch, Anne Rittstieg, Peter Balcarek, Tim Alexander Walde, Jan P. Schüttrumpf, Martin M. Wachowski, Klaus M. Stürmer, Karl-Heinz Frosch

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 11/2012

Login to get access

Abstract

Purpose

The aim of this study was to evaluate the clinical outcome and differences in anterior–posterior laxity of ACL reconstruction using a bioabsorbable interference screw for femoral graft fixation when compared to femoral bioabsorbable cross pin fixation.

Methods

Clinical outcome was evaluated among 59 patients 1 year after arthroscopic ACL reconstruction with hamstrings graft in a prospective, non-randomised study. In 31 cases, femoral fixation of the graft was performed using a bioabsorbable interference screw. In 28 cases, two bioabsorbable cross pins were used for femoral fixation. Patients were evaluated using Tegner, Lysholm and Marshall scores, the visual analogue scale for pain and KT-1000 arthrometer measurement.

Results

No significant difference (P ≥ 0.05) was observed at follow-up for the knee scores. The average Tegner score was 5.83 points (±2.00) for the interference screw fixation and 5.83 points (±1.24) for the cross pin fixation; the average Lysholm score was 93.58 (±5.79) to 92.72 (±6.34) points; and the average Marshall score 46.72 (±2.4) to 47.30 (±2.35) points. No significant difference was found for the visual analogue scale for pain. KT-1000 arthrometer measurement revealed a significant (P < 0.05) difference in the mean side-to-side anterior translation at all applied forces. At 67 N, the mean difference was 1.53 mm (±1.24) in the interference screw group and 0.47 mm (±1.18) in the cross pin group (P < 0.05). At 89 N, the mean differences were 1.85 mm (±1.29) versus 0.59 mm (±1.59), respectively, (P < 0.05), and maximum manual displacements were 2.02 mm (±1.26) versus 1.22 mm (1.18; P < 0.05).

Conclusions

In ACL reconstruction with hamstrings graft, similar clinical results are obtained for the use of bioabsorbable cross pins when compared to bioabsorbable interference screws for femoral fixation. Cross pin fixation was superior with regard to the anteroposterior laxity as measured with KT-1000.
Literature
1.
go back to reference Andersson D, Samuelsson K, Karlsson J (2009) Treatment of anterior cruciate ligament injuries with special reference to surgical technique and rehabilitation: an assessment of randomized controlled trials. Arthroscopy 25(6):653–685PubMedCrossRef Andersson D, Samuelsson K, Karlsson J (2009) Treatment of anterior cruciate ligament injuries with special reference to surgical technique and rehabilitation: an assessment of randomized controlled trials. Arthroscopy 25(6):653–685PubMedCrossRef
2.
go back to reference Bostman O, Hirvensalo E, Makinen J, Rokkanen P (1990) Foreign body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br 72(4):592–596PubMed Bostman O, Hirvensalo E, Makinen J, Rokkanen P (1990) Foreign body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br 72(4):592–596PubMed
3.
go back to reference Brand J, Weiler A, Caborn DN, Brown CH Jr, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28(5):761–774PubMed Brand J, Weiler A, Caborn DN, Brown CH Jr, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28(5):761–774PubMed
4.
go back to reference Cain EL, Phillips BB, Charlebois SZ, Azar FM (2005) Effect of tibial tunnel dilation on pullout strength of semitendinosus-gracilis graft in anterior cruciate ligament reconstruction. Orthopedics 28(8):779–783PubMed Cain EL, Phillips BB, Charlebois SZ, Azar FM (2005) Effect of tibial tunnel dilation on pullout strength of semitendinosus-gracilis graft in anterior cruciate ligament reconstruction. Orthopedics 28(8):779–783PubMed
5.
go back to reference Drogset JO, Straume LG, Bjørkmo I, Myhr G (2011) A prospective randomized study of ACL-reconstructions using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws. Knee Surg Sports Traumatol Arthrosc 19(5):753–759PubMedCrossRef Drogset JO, Straume LG, Bjørkmo I, Myhr G (2011) A prospective randomized study of ACL-reconstructions using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws. Knee Surg Sports Traumatol Arthrosc 19(5):753–759PubMedCrossRef
6.
go back to reference Drogset JO, Grontvedt T, Myhr G (2006) Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of bone-patellar tendon-bone autografts in endoscopic reconstruction of the anterior cruciate ligament. Am J Sports Med 34(7):1164–1169PubMedCrossRef Drogset JO, Grontvedt T, Myhr G (2006) Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of bone-patellar tendon-bone autografts in endoscopic reconstruction of the anterior cruciate ligament. Am J Sports Med 34(7):1164–1169PubMedCrossRef
7.
go back to reference Emond CE, Woelber EB, Kurd SK, Ciccotti MG, Cohen SB (2011) A comparison of the results of anterior cruciate ligament reconstruction using bioabsorbable versus metal interference screws: a meta-analysis. J Bone Joint Surg Am 93(6):572–580PubMedCrossRef Emond CE, Woelber EB, Kurd SK, Ciccotti MG, Cohen SB (2011) A comparison of the results of anterior cruciate ligament reconstruction using bioabsorbable versus metal interference screws: a meta-analysis. J Bone Joint Surg Am 93(6):572–580PubMedCrossRef
8.
go back to reference Frosch KH, Sawallich T, Schütze G, Losch A, Walde TA, Balcarek P, Konietschke F, Stürmer KM (2009) Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction. Strateg Trauma Limb Reconstr 2:73–79CrossRef Frosch KH, Sawallich T, Schütze G, Losch A, Walde TA, Balcarek P, Konietschke F, Stürmer KM (2009) Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction. Strateg Trauma Limb Reconstr 2:73–79CrossRef
9.
go back to reference George MS, Dunn WR, Spindler KP (2006) Current concepts review: revision anterior cruciate ligament reconstruction. Am J Sports Med 34(12):2026–2037PubMedCrossRef George MS, Dunn WR, Spindler KP (2006) Current concepts review: revision anterior cruciate ligament reconstruction. Am J Sports Med 34(12):2026–2037PubMedCrossRef
10.
go back to reference Halewood C, Hirschmann MT, Newman S, Hleihil J, Chaimski G, Amis AA (2011) The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study in vitro. Knee Surg Sports Traumatol Arthrosc 19(4):559–567PubMedCrossRef Halewood C, Hirschmann MT, Newman S, Hleihil J, Chaimski G, Amis AA (2011) The fixation strength of a novel ACL soft-tissue graft fixation device compared with conventional interference screws: a biomechanical study in vitro. Knee Surg Sports Traumatol Arthrosc 19(4):559–567PubMedCrossRef
11.
go back to reference Harilainen A, Sandelin J (2009) A prospective comparison of 3 hamstring ACL fixation devices–Rigidfix, BioScrew, and Intrafix–randomized into 4 groups with 2 years of follow-up. Am J Sports Med 37(4):699–706PubMedCrossRef Harilainen A, Sandelin J (2009) A prospective comparison of 3 hamstring ACL fixation devices–Rigidfix, BioScrew, and Intrafix–randomized into 4 groups with 2 years of follow-up. Am J Sports Med 37(4):699–706PubMedCrossRef
12.
go back to reference Hoeher J, Moller HD, Fu FH (1998) Bone tunnel enlargement after anterior cruciate ligament reconstruction: fact or fiction? Knee Surg Sports Traumatol Arthrosc 6(4):231–240CrossRef Hoeher J, Moller HD, Fu FH (1998) Bone tunnel enlargement after anterior cruciate ligament reconstruction: fact or fiction? Knee Surg Sports Traumatol Arthrosc 6(4):231–240CrossRef
13.
go back to reference Hunt P, Rehm O, Weiler A (2006) Soft tissue graft interference fit fixation: observations on graft insertion site healing and tunnel remodeling 2 years after ACL reconstruction in sheep. Knee Surg Sports Traumatol Arthrosc 14(12):1245–1251PubMedCrossRef Hunt P, Rehm O, Weiler A (2006) Soft tissue graft interference fit fixation: observations on graft insertion site healing and tunnel remodeling 2 years after ACL reconstruction in sheep. Knee Surg Sports Traumatol Arthrosc 14(12):1245–1251PubMedCrossRef
14.
go back to reference Johnson D, Harner CD, Maday MG (1994) Revision anterior cruciate ligament surgery. In: Fu F, Harner CD, Vince KG (eds) Knee surgery. Williams & Wilkins, Baltimore, pp 877–895 Johnson D, Harner CD, Maday MG (1994) Revision anterior cruciate ligament surgery. In: Fu F, Harner CD, Vince KG (eds) Knee surgery. Williams & Wilkins, Baltimore, pp 877–895
15.
go back to reference Kocher MS, Steadman JR, Briggs KK, Sterett WI, Hawkins RJ (2004) Relationships between objective assessment of ligament stability and subjective assessment of symptoms and function after anterior cruciate ligament reconstruction. Am J Sports Med 32(3):629–634PubMedCrossRef Kocher MS, Steadman JR, Briggs KK, Sterett WI, Hawkins RJ (2004) Relationships between objective assessment of ligament stability and subjective assessment of symptoms and function after anterior cruciate ligament reconstruction. Am J Sports Med 32(3):629–634PubMedCrossRef
16.
go back to reference Logan M, Williams A, Myers P (2003) Is bone tunnel osseointegration in hamstring tendon autograft anterior cruciate ligament reconstruction important? Arthroscopy 19(8):E1–E3PubMed Logan M, Williams A, Myers P (2003) Is bone tunnel osseointegration in hamstring tendon autograft anterior cruciate ligament reconstruction important? Arthroscopy 19(8):E1–E3PubMed
17.
go back to reference Marks P, O’Donnell S, Yee G (2008) A pilot clinical evaluation comparing the Mitek bone-tendon-bone cross pin and bioabsorbable screw in anterior cruciate ligament reconstruction fixation, a randomized double blind controlled trial. Knee 15(3):168–173PubMedCrossRef Marks P, O’Donnell S, Yee G (2008) A pilot clinical evaluation comparing the Mitek bone-tendon-bone cross pin and bioabsorbable screw in anterior cruciate ligament reconstruction fixation, a randomized double blind controlled trial. Knee 15(3):168–173PubMedCrossRef
18.
go back to reference Marshall JL, Fetto JF, Botero PM (1977) Knee ligament injuries. A standardized evaluation method. Clin Orthop Relat Res 123:115–129PubMed Marshall JL, Fetto JF, Botero PM (1977) Knee ligament injuries. A standardized evaluation method. Clin Orthop Relat Res 123:115–129PubMed
19.
go back to reference Musahl V, Voos J, O’Loughlin PF, Stueber V, Kendoff D, Pearle AD (2010) Mechanized pivot shift test achieves greater accuracy than manual pivot shift test. Knee Surg Sports Traumatol Arthrosc 18(9):1208–1213PubMedCrossRef Musahl V, Voos J, O’Loughlin PF, Stueber V, Kendoff D, Pearle AD (2010) Mechanized pivot shift test achieves greater accuracy than manual pivot shift test. Knee Surg Sports Traumatol Arthrosc 18(9):1208–1213PubMedCrossRef
20.
go back to reference Myers P, Logan M, Stokes A, Boyd K, Watts M (2008) Bioabsorbable versus titanium interference screws with hamstring autograft in anterior cruciate ligament reconstruction: a prospective randomized trial with 2-years follow-up. Arthroscopy 24(7):817–823PubMedCrossRef Myers P, Logan M, Stokes A, Boyd K, Watts M (2008) Bioabsorbable versus titanium interference screws with hamstring autograft in anterior cruciate ligament reconstruction: a prospective randomized trial with 2-years follow-up. Arthroscopy 24(7):817–823PubMedCrossRef
21.
go back to reference Noyes FR, Butler DL, Grood ES et al (1984) Biomechanical analysis of human grafts used in knee-ligament repairs and reconstructions. J Bone Joint Surg Am 66(3):344–352PubMed Noyes FR, Butler DL, Grood ES et al (1984) Biomechanical analysis of human grafts used in knee-ligament repairs and reconstructions. J Bone Joint Surg Am 66(3):344–352PubMed
22.
go back to reference Radford MJ, Noakes J, Read J, Wood DG (2005) The natural history of a bioabsorbable interference screw used for anterior cruciate ligament reconstruction with a 4-strand hamstring technique. Arthroscopy 21(6):707–710PubMedCrossRef Radford MJ, Noakes J, Read J, Wood DG (2005) The natural history of a bioabsorbable interference screw used for anterior cruciate ligament reconstruction with a 4-strand hamstring technique. Arthroscopy 21(6):707–710PubMedCrossRef
23.
go back to reference Shen C, Jiang SD, Jiang LS, Dai LY (2010) Bioabsorbable versus metallic interference screw fixation in anterior cruciate ligament reconstruction: a meta-analysis of randomized controlled trials. Arthroscopy 26(5):705–713PubMedCrossRef Shen C, Jiang SD, Jiang LS, Dai LY (2010) Bioabsorbable versus metallic interference screw fixation in anterior cruciate ligament reconstruction: a meta-analysis of randomized controlled trials. Arthroscopy 26(5):705–713PubMedCrossRef
24.
go back to reference Singhal MC, Holzhauer M, Powell D, Johnson DL (2008) MRI evaluation of the tibial tunnel/screw/tendon interface after ACL reconstruction using a bioabsorbable interference screw. Orthopedics 31(6):575–579PubMedCrossRef Singhal MC, Holzhauer M, Powell D, Johnson DL (2008) MRI evaluation of the tibial tunnel/screw/tendon interface after ACL reconstruction using a bioabsorbable interference screw. Orthopedics 31(6):575–579PubMedCrossRef
25.
go back to reference Tegnander A, Engebretsen L, Bergh K (1994) Activation of the complement system and adverse effects of biodegradable pins of polylactic acid (Biofix) in osteochondritis dissecans. Acta Orthop Scand 65(4):472–475PubMedCrossRef Tegnander A, Engebretsen L, Bergh K (1994) Activation of the complement system and adverse effects of biodegradable pins of polylactic acid (Biofix) in osteochondritis dissecans. Acta Orthop Scand 65(4):472–475PubMedCrossRef
26.
go back to reference Tegner Y, Lysholm J (1985) Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res 198:43–49PubMed Tegner Y, Lysholm J (1985) Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res 198:43–49PubMed
27.
go back to reference Warden WH, Chooljian D, Jackson DW (2008) Ten-year magnetic resonance imaging follow-up of bioabsorbable poly-l-lactic acid interference screws after anterior cruciate ligament reconstruction. Arthroscopy 24(3):371–373CrossRef Warden WH, Chooljian D, Jackson DW (2008) Ten-year magnetic resonance imaging follow-up of bioabsorbable poly-l-lactic acid interference screws after anterior cruciate ligament reconstruction. Arthroscopy 24(3):371–373CrossRef
28.
go back to reference Weninger P, Zifko B, Liska M, Spitaler R, Pelinka H, Hertz H (2008) Anterior cruciate ligament reconstruction using autografts and double biodegradable femoral cross-pin fixation: functional, radiographic and MRI outcome after 2-year minimum follow-up. Knee Surg Sports Traumatol Arthrosc 16(11):988–995PubMedCrossRef Weninger P, Zifko B, Liska M, Spitaler R, Pelinka H, Hertz H (2008) Anterior cruciate ligament reconstruction using autografts and double biodegradable femoral cross-pin fixation: functional, radiographic and MRI outcome after 2-year minimum follow-up. Knee Surg Sports Traumatol Arthrosc 16(11):988–995PubMedCrossRef
29.
go back to reference Zantop T, Weimann A, Rümmler M, Hassenpflug J, Petersen W (2004) Initial fixation strength of two bioabsorbable pins for the fixation of hamstring grafts compared to interference screw fixation: single cycle and cyclic loading. Am J Sports Med 32(3):641–649PubMedCrossRef Zantop T, Weimann A, Rümmler M, Hassenpflug J, Petersen W (2004) Initial fixation strength of two bioabsorbable pins for the fixation of hamstring grafts compared to interference screw fixation: single cycle and cyclic loading. Am J Sports Med 32(3):641–649PubMedCrossRef
30.
go back to reference Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of softtissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide-tricalcium phosphate screws. Arthroscopy 22(11):1204–1210PubMedCrossRef Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of softtissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide-tricalcium phosphate screws. Arthroscopy 22(11):1204–1210PubMedCrossRef
31.
go back to reference Zantop T, Weimann A, Wolle K, Musahl V, Langer M, Petersen W (2007) Initial and 6 weeks postoperative structural properties of soft tissue anterior cruciate ligament reconstructions with crosspin or interference screw fixation: an in vivo study in sheep. Arthroscopy 23(1):14–20PubMedCrossRef Zantop T, Weimann A, Wolle K, Musahl V, Langer M, Petersen W (2007) Initial and 6 weeks postoperative structural properties of soft tissue anterior cruciate ligament reconstructions with crosspin or interference screw fixation: an in vivo study in sheep. Arthroscopy 23(1):14–20PubMedCrossRef
Metadata
Title
Bioabsorbable interference screw versus bioabsorbable cross pins: influence of femoral graft fixation on the clinical outcome after ACL reconstruction
Authors
Stephan Frosch
Anne Rittstieg
Peter Balcarek
Tim Alexander Walde
Jan P. Schüttrumpf
Martin M. Wachowski
Klaus M. Stürmer
Karl-Heinz Frosch
Publication date
01-11-2012
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 11/2012
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1875-4

Other articles of this Issue 11/2012

Knee Surgery, Sports Traumatology, Arthroscopy 11/2012 Go to the issue