Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 3/2016

Open Access 01-03-2016 | Original Paper

Automatic aortic root landmark detection in CTA images for preprocedural planning of transcatheter aortic valve implantation

Authors: Mustafa Elattar, Esther Wiegerinck, Floortje van Kesteren, Lucile Dubois, Nils Planken, Ed Vanbavel, Jan Baan, Henk Marquering

Published in: The International Journal of Cardiovascular Imaging | Issue 3/2016

Login to get access

Abstract

Transcatheter aortic valve implantation is currently a well-established minimal invasive treatment option for patients with severe aortic valve stenosis. CT Angiography is used for the pre-operative planning and sizing of the prosthesis. To reduce the inconsistency in sizing due to interobserver variability, we introduce and evaluate an automatic aortic root landmarks detection method to determine the sizing parameters. The proposed algorithm detects the sinotubular junction, two coronary ostia, and three valvular hinge points on a segmented aortic root surface. Using these aortic root landmarks, the automated method determines annulus radius, annulus orientation, and distance from annulus plane to right and left coronary ostia. Validation is performed by the comparison with manual measurements of two observers for 40 CTA image datasets. Detection of landmarks showed high accuracy where the mean distance between the automatically detected and reference landmarks was 2.81 ± 2.08 mm, comparable to the interobserver variation of 2.67 ± 2.52 mm. The mean annulus to coronary ostium distance was 16.9 ± 3.3 and 17.1 ± 3.3 mm for the automated and the reference manual measurements, respectively, with a mean paired difference of 1.89 ± 1.71 mm and interobserver mean paired difference of 1.38 ± 1.52 mm. Automated detection of aortic root landmarks enables automated sizing with good agreement with manual measurements, which suggests applicability of the presented method in current clinical practice.
Literature
4.
go back to reference Kamath AR, Pai RG (2008) Risk factors for progression of calcific aortic stenosis and potential therapeutic targets. Int J Angiol 17:63–70PubMedCentralPubMed Kamath AR, Pai RG (2008) Risk factors for progression of calcific aortic stenosis and potential therapeutic targets. Int J Angiol 17:63–70PubMedCentralPubMed
8.
go back to reference Leon M, Smith C, Mack M (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. Engl J 363:1597–1607CrossRef Leon M, Smith C, Mack M (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. Engl J 363:1597–1607CrossRef
9.
go back to reference Vahanian A, Alfieri O, Al-Attar N et al (2008) Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percu. Eur Heart J 29:1463–1470. doi:10.1093/eurheartj/ehn183 CrossRefPubMed Vahanian A, Alfieri O, Al-Attar N et al (2008) Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percu. Eur Heart J 29:1463–1470. doi:10.​1093/​eurheartj/​ehn183 CrossRefPubMed
10.
go back to reference Baan J, Yong ZY, Koch KT et al (2010) Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the Core Valve prosthesis. Am Heart J 159:497–503. doi:10.1016/j.ahj.2009.12.009 CrossRefPubMed Baan J, Yong ZY, Koch KT et al (2010) Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the Core Valve prosthesis. Am Heart J 159:497–503. doi:10.​1016/​j.​ahj.​2009.​12.​009 CrossRefPubMed
15.
go back to reference Okuyama K, Jilaihawi H, Makkar RR (2013) Leaflet length and left main coronary artery occlusion following transcatheter aortic valve replacement. Catheter Cardiovasc Interv 82:E754–E759. doi:10.1002/ccd.25059 CrossRefPubMed Okuyama K, Jilaihawi H, Makkar RR (2013) Leaflet length and left main coronary artery occlusion following transcatheter aortic valve replacement. Catheter Cardiovasc Interv 82:E754–E759. doi:10.​1002/​ccd.​25059 CrossRefPubMed
16.
go back to reference Elattar MA, Wiegerinck EM, Planken RN et al (2014) Automatic segmentation of the aortic root in CT angiography of candidate patients for transcatheter aortic valve implantation. Med Biol Eng Comput 52:611–618. doi:10.1007/s11517-014-1165-7 CrossRefPubMed Elattar MA, Wiegerinck EM, Planken RN et al (2014) Automatic segmentation of the aortic root in CT angiography of candidate patients for transcatheter aortic valve implantation. Med Biol Eng Comput 52:611–618. doi:10.​1007/​s11517-014-1165-7 CrossRefPubMed
17.
go back to reference Bertaso AG, Wong DTL, Liew GYH et al (2012) Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole. Int J Cardiovasc Imaging 28:2091–2098. doi:10.1007/s10554-012-0018-4 CrossRefPubMed Bertaso AG, Wong DTL, Liew GYH et al (2012) Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole. Int J Cardiovasc Imaging 28:2091–2098. doi:10.​1007/​s10554-012-0018-4 CrossRefPubMed
20.
go back to reference Arjmand Shabestari A, Pourghorban R, Tehrai M et al. (2013) Comparison of aortic root dimension changes during cardiac cycle between the patients with and without aortic valve calcification using ECG-gated 64-slice and dual-source 256-slice computed tomography scanners: results of a multicenter study. Int J Cardiovasc Imaging 1–10. doi: 10.1007/s10554-013-0217-7 Arjmand Shabestari A, Pourghorban R, Tehrai M et al. (2013) Comparison of aortic root dimension changes during cardiac cycle between the patients with and without aortic valve calcification using ECG-gated 64-slice and dual-source 256-slice computed tomography scanners: results of a multicenter study. Int J Cardiovasc Imaging 1–10. doi: 10.​1007/​s10554-013-0217-7
24.
go back to reference Waechter I, Kneser R, Korosoglou G et al (2010) Patient specific models for planning and guidance of minimally invasive aortic valve implantation. Med Image Comput Comput Assist Interv 13:526–533PubMed Waechter I, Kneser R, Korosoglou G et al (2010) Patient specific models for planning and guidance of minimally invasive aortic valve implantation. Med Image Comput Comput Assist Interv 13:526–533PubMed
25.
Metadata
Title
Automatic aortic root landmark detection in CTA images for preprocedural planning of transcatheter aortic valve implantation
Authors
Mustafa Elattar
Esther Wiegerinck
Floortje van Kesteren
Lucile Dubois
Nils Planken
Ed Vanbavel
Jan Baan
Henk Marquering
Publication date
01-03-2016
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 3/2016
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-015-0793-9

Other articles of this Issue 3/2016

The International Journal of Cardiovascular Imaging 3/2016 Go to the issue