Skip to main content
Top
Published in: Pediatric Cardiology 1/2017

01-01-2017 | Case Report

Atrial Septal Defect Closure with Occlutech® ASD Fenestrated Device in a Child with Severe Pulmonary Hypertension

Authors: Francisco Gonzalez-Barlatay, Anne Fournier, Marie-Josée Raboisson, Nagib Dahdah

Published in: Pediatric Cardiology | Issue 1/2017

Login to get access

Abstract

We report a 5-year-old patient with severe pulmonary hypertension and a large secundum atrial septal defect who benefited from a percutaneous closure of the defect with an Occlutech® custom-made fenestrated device. Whereas the closure is technically identical to standard atrial defect closure, the immediate and midterm beneficial results are presented.
Literature
1.
go back to reference Schwerzmann M, Zafar M, McLaughlin PR, Chamberlain DW, Webb G, Granton J (2006) Atrial septal defect closure in a patient with “irreversible” pulmonary hypertensive arteriopathy. Int J Cardiol 110(1):104–107CrossRefPubMed Schwerzmann M, Zafar M, McLaughlin PR, Chamberlain DW, Webb G, Granton J (2006) Atrial septal defect closure in a patient with “irreversible” pulmonary hypertensive arteriopathy. Int J Cardiol 110(1):104–107CrossRefPubMed
2.
go back to reference Skinner GJ, Tulloh RM, Tometzki AJ, Schulze-Neick I, Morgan GJ (2013) Atrial septal defect closure with an Amplatzer septal occluder fenestrated with a coronary stent in a child with pulmonary arterial hypertension. Cardiol Young 23(05):692–696CrossRefPubMed Skinner GJ, Tulloh RM, Tometzki AJ, Schulze-Neick I, Morgan GJ (2013) Atrial septal defect closure with an Amplatzer septal occluder fenestrated with a coronary stent in a child with pulmonary arterial hypertension. Cardiol Young 23(05):692–696CrossRefPubMed
3.
go back to reference Kretschmar O, Sglimbea A, Corti R, Knirsch W (2010) Shunt reduction with a fenestrated Amplatzer device. Catheter Cardiovasc Interv 76(4):564–571CrossRefPubMed Kretschmar O, Sglimbea A, Corti R, Knirsch W (2010) Shunt reduction with a fenestrated Amplatzer device. Catheter Cardiovasc Interv 76(4):564–571CrossRefPubMed
4.
go back to reference Schneider HE, Jux C, Kriebel T, Paul T (2011) Fate of a modified fenestration of atrial septal occluder device after transcatheter closure of atrial septal defects in elderly patients. J Interv Cardiol 24(5):485–490CrossRefPubMed Schneider HE, Jux C, Kriebel T, Paul T (2011) Fate of a modified fenestration of atrial septal occluder device after transcatheter closure of atrial septal defects in elderly patients. J Interv Cardiol 24(5):485–490CrossRefPubMed
5.
go back to reference Badesch DB, Abman SH, Ahearn GS, Barst RJ, McCrory DC, Simonneau G, McLaughlin VV (2004) American College of Chest Physicians. Medical therapy for pulmonary arterial hypertension: ACCP evidence based clinical practice guidelines. Chest 126(Suppl. 1):35S–62SCrossRefPubMed Badesch DB, Abman SH, Ahearn GS, Barst RJ, McCrory DC, Simonneau G, McLaughlin VV (2004) American College of Chest Physicians. Medical therapy for pulmonary arterial hypertension: ACCP evidence based clinical practice guidelines. Chest 126(Suppl. 1):35S–62SCrossRefPubMed
6.
go back to reference van Riel AC, Blok IM, Zwinderman AH, Wajon EM, Sadee AS, Bakker-de Boo M, van Dijk AP, Hoendermis ES, Riezebos RK, Mulder BJ, Bouma BJ (2015) Lifetime risk of pulmonary hypertension for all patients after shunt closure. J Am Coll Cardiol 66(9):1084–1086CrossRefPubMed van Riel AC, Blok IM, Zwinderman AH, Wajon EM, Sadee AS, Bakker-de Boo M, van Dijk AP, Hoendermis ES, Riezebos RK, Mulder BJ, Bouma BJ (2015) Lifetime risk of pulmonary hypertension for all patients after shunt closure. J Am Coll Cardiol 66(9):1084–1086CrossRefPubMed
8.
go back to reference Ammar RI, Hegazy RA (2013) Transcatheter closure of secundum ASD using Occlutech Figulla-N device in symptomatic children younger than 2 years of age. J Invasive Cardiol 25(2):76–79PubMed Ammar RI, Hegazy RA (2013) Transcatheter closure of secundum ASD using Occlutech Figulla-N device in symptomatic children younger than 2 years of age. J Invasive Cardiol 25(2):76–79PubMed
Metadata
Title
Atrial Septal Defect Closure with Occlutech® ASD Fenestrated Device in a Child with Severe Pulmonary Hypertension
Authors
Francisco Gonzalez-Barlatay
Anne Fournier
Marie-Josée Raboisson
Nagib Dahdah
Publication date
01-01-2017
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 1/2017
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-016-1530-4

Other articles of this Issue 1/2017

Pediatric Cardiology 1/2017 Go to the issue