Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 3/2019

01-09-2019 | Atrial Fibrillation

The modified ablation index: a novel determinant of acute pulmonary vein reconnections after pulmonary vein isolation

Authors: Yuji Wakamatsu, Koichi Nagashima, Ichiro Watanabe, Ryuta Watanabe, Masaru Arai, Naoto Otsuka, Seina Yagyu, Sayaka Kurokawa, Kimie Ohkubo, Toshiko Nakai, Yasuo Okumura

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 3/2019

Login to get access

Abstract

Background

Although pulmonary vein isolation (PVI) guided by the ablation index (AI) has been well-developed, acute PV reconnections (PVRs) still occur. This study aimed to compare the prognostic performance of the modified AI and its optimal cut-off value for the prediction of acute PVRs to ensure durable PVI.

Methods

Three-dimensional left atrium (LA) voltage maps created before an extensive encircling PVI in 64 patients with atrial fibrillation (AF) (45 men, 62 ± 10 years) were examined for an association between electrogram voltage amplitude recorded from the PV–LA junction and acute post-PVI PVRs (spontaneous PVRs and/or ATP-provoked dormant PV conduction).

Results

Acute PVRs were observed in 22 patients (34%) and 33 (3%) of the 1012 PV segments. Acute PVRs were significantly associated with segments with higher bipolar voltage zones (3.23 ± 1.17 vs. 1.97 ± 1.20 mV, P < 0.0001), lower mean AI values (449 [428–450] vs. 460 [437–486], P = 0.05), and radiofrequency lesion gaps ≥ 6 mm (48 vs. 32%, P = 0.04), but not with contact force, force–time integral, or power. We created the modified AI calculated as AI/LA bipolar voltage, and found it to be significantly lower in areas with acute PVRs than in those without (152 [109–185] vs. 256 [176–413] AU/mV, P < 0.0001). Univariate analysis showed the prognostic performance of the modified AI, with an area under the curve of 0.801 (0.775–0.825), to be the highest of all the significant parameters.

Conclusions

Low values of the novel modified AI on the PV-encircling ablation line were strongly associated with acute PVRs.
Literature
3.
go back to reference Phlips T, Taghji P, El Haddad M, Wolf M, Knecht S, Vandekerckhove Y, et al. Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the ‘CLOSE’-protocol. EUROPACE. 2018. https://doi.org/10.1093/europace/eux376. Phlips T, Taghji P, El Haddad M, Wolf M, Knecht S, Vandekerckhove Y, et al. Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the ‘CLOSE’-protocol. EUROPACE. 2018. https://​doi.​org/​10.​1093/​europace/​eux376.
8.
go back to reference Schwartzman D, Ren JF, Devine WA, Callans DJ. Cardiac swelling associated with linear radiofrequency ablation in the atrium. J Interv Card Electrophysiol. 2001;5(2):159–66.CrossRefPubMed Schwartzman D, Ren JF, Devine WA, Callans DJ. Cardiac swelling associated with linear radiofrequency ablation in the atrium. J Interv Card Electrophysiol. 2001;5(2):159–66.CrossRefPubMed
9.
11.
go back to reference Okumura Y, Watanabe I, Iso K, Nagashima K, Sonoda K, Sasaki N, et al. Clinical utility of automated ablation lesion tagging based on catheter stability information (VisiTag module of the CARTO 3 system) with contact force-time integral during pulmonary vein isolation for atrial fibrillation. J Interv Card Electrophysiol. 2016;47:245–52. https://doi.org/10.1007/s10840-016-0156-z.CrossRefPubMed Okumura Y, Watanabe I, Iso K, Nagashima K, Sonoda K, Sasaki N, et al. Clinical utility of automated ablation lesion tagging based on catheter stability information (VisiTag module of the CARTO 3 system) with contact force-time integral during pulmonary vein isolation for atrial fibrillation. J Interv Card Electrophysiol. 2016;47:245–52. https://​doi.​org/​10.​1007/​s10840-016-0156-z.CrossRefPubMed
13.
16.
go back to reference Iso K, Okumura Y, Watanabe I, Nagashima K, Sonoda K, Kogawa R, et al. Wall thickness of the pulmonary vein-left atrial junction rather than electrical information as the major determinant of dormant conduction after contact force-guided pulmonary vein isolation. J Interv Card Electrophysiol. 2016;46:325–33. https://doi.org/10.1007/s10840-016-0147-0.CrossRefPubMed Iso K, Okumura Y, Watanabe I, Nagashima K, Sonoda K, Kogawa R, et al. Wall thickness of the pulmonary vein-left atrial junction rather than electrical information as the major determinant of dormant conduction after contact force-guided pulmonary vein isolation. J Interv Card Electrophysiol. 2016;46:325–33. https://​doi.​org/​10.​1007/​s10840-016-0147-0.CrossRefPubMed
17.
go back to reference Haissaguerre M, Shah DC, Jais P, Hocini M, Yamane T, Deisenhofer I, et al. Electrophysiological breakthroughs from the left atrium to the pulmonary veins. Circulation. 2000;102(20):2463–5.CrossRefPubMed Haissaguerre M, Shah DC, Jais P, Hocini M, Yamane T, Deisenhofer I, et al. Electrophysiological breakthroughs from the left atrium to the pulmonary veins. Circulation. 2000;102(20):2463–5.CrossRefPubMed
Metadata
Title
The modified ablation index: a novel determinant of acute pulmonary vein reconnections after pulmonary vein isolation
Authors
Yuji Wakamatsu
Koichi Nagashima
Ichiro Watanabe
Ryuta Watanabe
Masaru Arai
Naoto Otsuka
Seina Yagyu
Sayaka Kurokawa
Kimie Ohkubo
Toshiko Nakai
Yasuo Okumura
Publication date
01-09-2019
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 3/2019
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-018-0501-5

Other articles of this Issue 3/2019

Journal of Interventional Cardiac Electrophysiology 3/2019 Go to the issue