Skip to main content
Top
Published in: BMC Cardiovascular Disorders 1/2022

Open Access 01-12-2022 | Atrial Fibrillation | Research

Impact of baseline impedance of pulmonary vein antrum on success of catheter ablation for paroxysmal atrial fibrillation guided by ablation index

Authors: Yuanjun Sun, Xianjie Xiao, Xiaomeng Yin, Lianjun Gao, Xiaohong Yu, Rongfeng Zhang, Zhongzhen Wang, Shiyu Dai, Yanzong Yang, Yunlong Xia

Published in: BMC Cardiovascular Disorders | Issue 1/2022

Login to get access

Abstract

Objective

Ablation index (AI) is an effective ablation quality marker. Impedance is also an important factor for lesion formation. The present study evaluated the influence of the baseline impedance in the effect of ablation for atrial fibrillation (AF) guided by AI.

Methods

This was a retrospective study. 101 patients with paroxysmal AF (PAF) were enrolled. All patients underwent radiofrequency ablation guided by the same AI strategy. The ablation strategy was pulmonary vein (PV) isolation with non-PV triggers ablation. The baseline impedance of the ablation points was recorded. The patients were followed up every 3 months or so.

Results

During a median follow-up of 12 (4–14) months, freedom from AF/atrial tachycardia recurrence were 82.2%. No difference existed in baseline characteristics between the success group and the recurrence group. The average baseline impedance was 124.3 ± 9.7 Ω. The baseline impedance of the ablation points in success group was lower compared to the recurrence group (122.9 ± 9.4 vs. 130.5 ± 8.8 Ω, P < 0.01). The ratio of impedance drop in the success group was higher than the recurrence group ([8.8 ± 1.4]% vs. [8.1 ± 1.2]%, P = 0.03). Multivariate analysis revealed that baseline impedance, PAF duration and AI were the independent predictors of AF recurrence. The cumulative free of recurrence rate of low-impedance group (≤ 124 Ω, n = 54) was higher than that of high-impedance group.

Conclusion

Baseline impedance correlates with clinical outcome of radiofrequency ablation for PAF guided by AI. Higher impedance in the same AI strategy may result in an ineffective lesion which probably causes recurrence.
Appendix
Available only for authorised users
Literature
1.
go back to reference Verma A, Jiang CY, Betts TR, Chen J, Deisenhofer I, Mantovan R, Macle L, Morillo CA, Haverkamp W, Weerasooriya R, Albenque JP, Nardi S, Menardi E, Novak P, Sanders P. STAR AF II investigators: approaches to catheter ablation for persistent atrial fibrillation. N Engl J Med. 2015;372:1812–22.CrossRefPubMed Verma A, Jiang CY, Betts TR, Chen J, Deisenhofer I, Mantovan R, Macle L, Morillo CA, Haverkamp W, Weerasooriya R, Albenque JP, Nardi S, Menardi E, Novak P, Sanders P. STAR AF II investigators: approaches to catheter ablation for persistent atrial fibrillation. N Engl J Med. 2015;372:1812–22.CrossRefPubMed
2.
go back to reference Yin X, Zhao Z, Gao L, Chang D, Xiao X, Zhang R, Chen Q, Cheng J, Yang Y, Xi Y, Xia Y. Frequency gradient within coronary sinus predicts the long-term outcome of persistent atrial fibrillation catheter ablation. J Am Heart Assoc. 2017;6:e004869.CrossRefPubMedPubMedCentral Yin X, Zhao Z, Gao L, Chang D, Xiao X, Zhang R, Chen Q, Cheng J, Yang Y, Xi Y, Xia Y. Frequency gradient within coronary sinus predicts the long-term outcome of persistent atrial fibrillation catheter ablation. J Am Heart Assoc. 2017;6:e004869.CrossRefPubMedPubMedCentral
3.
go back to reference Whitaker J, Fish J, Harrison J, Chubb H, Williams SE, Fastl T, Corrado C, Van Zaen J, Gibbs J, O’Neill L, Mukherjee R, Rittey D, Thorsten J, Donskoy E, Sohal M, Rajani R, Niederer S, Wright M, O’Neill MD. Lesion index-guided ablation facilitates continuous, transmural, and durable lesions in a porcine recovery model. Circ Arrhythm Electrophysiol. 2018;11(4):e005892.CrossRefPubMed Whitaker J, Fish J, Harrison J, Chubb H, Williams SE, Fastl T, Corrado C, Van Zaen J, Gibbs J, O’Neill L, Mukherjee R, Rittey D, Thorsten J, Donskoy E, Sohal M, Rajani R, Niederer S, Wright M, O’Neill MD. Lesion index-guided ablation facilitates continuous, transmural, and durable lesions in a porcine recovery model. Circ Arrhythm Electrophysiol. 2018;11(4):e005892.CrossRefPubMed
4.
go back to reference Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, Jaïs P, Hindricks G, Peichl P, Yulzari A, Lambert H, Neuzil P, Natale A, Kuck KH. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm. 2012;9:1789–95.CrossRefPubMed Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, Jaïs P, Hindricks G, Peichl P, Yulzari A, Lambert H, Neuzil P, Natale A, Kuck KH. The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm. 2012;9:1789–95.CrossRefPubMed
5.
go back to reference Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, Schaumann A, Chun J, Falk P, Hennig D, Liu X, Bänsch D, Kuck KH. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique. Circulation. 2005;111:127–35.CrossRefPubMed Ouyang F, Antz M, Ernst S, Hachiya H, Mavrakis H, Deger FT, Schaumann A, Chun J, Falk P, Hennig D, Liu X, Bänsch D, Kuck KH. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique. Circulation. 2005;111:127–35.CrossRefPubMed
6.
go back to reference Nery PB, Belliveau D, Nair GM, Bernick J, Redpath CJ, Szczotka A, Sadek MM, Green MS, Wells G, Birnie DH. Relationship between pulmonary vein reconnection and atrial fibrillation recurrence: a systematic review and meta-analysis. JACC Clin Electrophysiol. 2016;2:474–83.CrossRefPubMed Nery PB, Belliveau D, Nair GM, Bernick J, Redpath CJ, Szczotka A, Sadek MM, Green MS, Wells G, Birnie DH. Relationship between pulmonary vein reconnection and atrial fibrillation recurrence: a systematic review and meta-analysis. JACC Clin Electrophysiol. 2016;2:474–83.CrossRefPubMed
7.
go back to reference Shah S, Barakat AF, Saliba WI, Abdur Rehman K, Tarakji KG, Rickard J, Bassiouny M, Baranowski B, Tchou P, Bhargava M, Chung M, Dresing T, Callahan T, Cantillon D, Kanj M, Lindsay BD, Wazni OM, Hussein AA. Recurrent atrial fibrillation after initial long-term ablation success: electrophysiological findings and outcomes of repeat ablation procedures. Circ Arrhythm Electrophysiol. 2018;11:e005785.CrossRefPubMed Shah S, Barakat AF, Saliba WI, Abdur Rehman K, Tarakji KG, Rickard J, Bassiouny M, Baranowski B, Tchou P, Bhargava M, Chung M, Dresing T, Callahan T, Cantillon D, Kanj M, Lindsay BD, Wazni OM, Hussein AA. Recurrent atrial fibrillation after initial long-term ablation success: electrophysiological findings and outcomes of repeat ablation procedures. Circ Arrhythm Electrophysiol. 2018;11:e005785.CrossRefPubMed
8.
go back to reference Anselmino M, Matta M, Bunch TJ, Fiala M, Scaglione M, Nölker G, Qian P, Neumann T, Ferraris F, Gaita F. Conduction recovery following catheter ablation in patients with recurrent atrial fibrillation and heart failure. Int J Cardiol. 2017;240:240–5.CrossRefPubMed Anselmino M, Matta M, Bunch TJ, Fiala M, Scaglione M, Nölker G, Qian P, Neumann T, Ferraris F, Gaita F. Conduction recovery following catheter ablation in patients with recurrent atrial fibrillation and heart failure. Int J Cardiol. 2017;240:240–5.CrossRefPubMed
9.
go back to reference Kowalski M, Grimes MM, Perez FJ, Kenigsberg DN, Koneru J, Kasirajan V, Wood MA, Ellenbogen KA. Histopathologic characterization of chronic radiofrequency ablation lesions for pulmonary vein isolation. J Am Coll Cardiol. 2012;59:930–8.CrossRefPubMed Kowalski M, Grimes MM, Perez FJ, Kenigsberg DN, Koneru J, Kasirajan V, Wood MA, Ellenbogen KA. Histopathologic characterization of chronic radiofrequency ablation lesions for pulmonary vein isolation. J Am Coll Cardiol. 2012;59:930–8.CrossRefPubMed
10.
go back to reference Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D. Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace. 2017;19:775–83.PubMed Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D. Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace. 2017;19:775–83.PubMed
11.
go back to reference Hussein A, Das M, Chaturvedi V, Asfour IK, Daryanani N, Morgan M, Ronayne C, Shaw M, Snowdon R, Gupta D. Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation. J Cardiovasc Electrophysiol. 2017;28:1037–47.CrossRefPubMed Hussein A, Das M, Chaturvedi V, Asfour IK, Daryanani N, Morgan M, Ronayne C, Shaw M, Snowdon R, Gupta D. Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation. J Cardiovasc Electrophysiol. 2017;28:1037–47.CrossRefPubMed
12.
go back to reference Park JK, Halperin BD, Kron J, Holcomb SR, Silka MJ. Analysis of body surface area as a determinant of impedance during radiofrequency catheter ablation in adults and children. J Electrocardiol. 1994;27:329–32.CrossRefPubMed Park JK, Halperin BD, Kron J, Holcomb SR, Silka MJ. Analysis of body surface area as a determinant of impedance during radiofrequency catheter ablation in adults and children. J Electrocardiol. 1994;27:329–32.CrossRefPubMed
13.
go back to reference Eick OJ. Factors influencing lesion formation during radiofrequency catheter ablation. Indian Pacing Electrophysiol J. 2003;3:117–28.PubMedPubMedCentral Eick OJ. Factors influencing lesion formation during radiofrequency catheter ablation. Indian Pacing Electrophysiol J. 2003;3:117–28.PubMedPubMedCentral
14.
go back to reference Bhaskaran A, Barry MA, Pouliopoulos J, Nalliah C, Qian P, Chik W, Thavapalachandran S, Davis L, McEwan A, Thomas S, Kovoor P, Thiagalingam A. Circuit impedance could be a crucial factor influencing radiofrequency ablation efficacy and safety: a myocardial phantom study of the problem and its correction. J Cardiovasc Electrophysiol. 2016;27:351–7.CrossRefPubMed Bhaskaran A, Barry MA, Pouliopoulos J, Nalliah C, Qian P, Chik W, Thavapalachandran S, Davis L, McEwan A, Thomas S, Kovoor P, Thiagalingam A. Circuit impedance could be a crucial factor influencing radiofrequency ablation efficacy and safety: a myocardial phantom study of the problem and its correction. J Cardiovasc Electrophysiol. 2016;27:351–7.CrossRefPubMed
15.
go back to reference Barkagan M, Rottmann M, Leshem E, Shen C, Buxton AE, Anter E. Effect of baseline impedance on ablation lesion dimensions: a multimodality concept validation from physics to clinical experience. Circ Arrhythm Electrophysiol. 2018;11(10):e006690.CrossRefPubMed Barkagan M, Rottmann M, Leshem E, Shen C, Buxton AE, Anter E. Effect of baseline impedance on ablation lesion dimensions: a multimodality concept validation from physics to clinical experience. Circ Arrhythm Electrophysiol. 2018;11(10):e006690.CrossRefPubMed
16.
go back to reference Bourier F, Ramirez FD, Martin CA, Vlachos K, Frontera A, Takigawa M, Kitamura T, Lam A, Duchateau J, Pambrun T, Cheniti G, Derval N, Denis A, Sacher F, Hocini M, Haissaguerre M, Jais P. Impedance, power, and current in radiofrequency ablation: insights from technical, ex vivo, and clinical studies. J Cardiovasc Electrophysiol. 2020;31(11):2836–45.CrossRefPubMed Bourier F, Ramirez FD, Martin CA, Vlachos K, Frontera A, Takigawa M, Kitamura T, Lam A, Duchateau J, Pambrun T, Cheniti G, Derval N, Denis A, Sacher F, Hocini M, Haissaguerre M, Jais P. Impedance, power, and current in radiofrequency ablation: insights from technical, ex vivo, and clinical studies. J Cardiovasc Electrophysiol. 2020;31(11):2836–45.CrossRefPubMed
17.
go back to reference Jain MK, Tomassoni G, Riley RE, Wolf PD. Effect of skin electrode location on radiofrequency ablation lesions: an in vivo and a three-dimensional finite element study. J Cardiovasc Electrophysiol. 1998;9:1325–35.CrossRefPubMed Jain MK, Tomassoni G, Riley RE, Wolf PD. Effect of skin electrode location on radiofrequency ablation lesions: an in vivo and a three-dimensional finite element study. J Cardiovasc Electrophysiol. 1998;9:1325–35.CrossRefPubMed
18.
go back to reference Wang D, Hulse J, Walsh E, Saul J. Factors influencing impedance during radiofrequency ablation in humans. Chin Med J. 1995;108:450–5.PubMed Wang D, Hulse J, Walsh E, Saul J. Factors influencing impedance during radiofrequency ablation in humans. Chin Med J. 1995;108:450–5.PubMed
19.
go back to reference Nath S, DiMarco JP, Gallop RG, McRury ID, Haines DE. Effects of dispersive electrode position and surface area on electrical parameters and temperature during radiofrequency catheter ablation. Am J Cardiol. 1996;77:765–7.CrossRefPubMed Nath S, DiMarco JP, Gallop RG, McRury ID, Haines DE. Effects of dispersive electrode position and surface area on electrical parameters and temperature during radiofrequency catheter ablation. Am J Cardiol. 1996;77:765–7.CrossRefPubMed
20.
go back to reference Borganelli M, El-Atassi R, Leon A, Kalbfleisch SJ, Calkins H, Morady F, Langberg JJ. Determinants of impedance during radiofrequency catheter ablation in humans. Am J Cardiol. 1992;69:1095–7.CrossRefPubMed Borganelli M, El-Atassi R, Leon A, Kalbfleisch SJ, Calkins H, Morady F, Langberg JJ. Determinants of impedance during radiofrequency catheter ablation in humans. Am J Cardiol. 1992;69:1095–7.CrossRefPubMed
21.
go back to reference Berjano E, d’Avila A. Lumped element electrical model based on three resistors for electrical impedance in radiofrequency cardiac ablation: estimations from analytical calculations and clinical data. Open Biomed Eng J. 2013;7:62–70.CrossRefPubMedPubMedCentral Berjano E, d’Avila A. Lumped element electrical model based on three resistors for electrical impedance in radiofrequency cardiac ablation: estimations from analytical calculations and clinical data. Open Biomed Eng J. 2013;7:62–70.CrossRefPubMedPubMedCentral
22.
go back to reference Shapira-Daniels A, Barkagan M, Rottmann M, Sroubek J, Tugal D, Carlozzi MA, McConville JW, Buxton AE, Anter E. Modulating the baseline impedance: an adjunctive technique for maximizing radiofrequency lesion dimensions in deep and intramural ventricular substrate. Circ Arrhythm Electrophysiol. 2019;12:e007336.CrossRefPubMedPubMedCentral Shapira-Daniels A, Barkagan M, Rottmann M, Sroubek J, Tugal D, Carlozzi MA, McConville JW, Buxton AE, Anter E. Modulating the baseline impedance: an adjunctive technique for maximizing radiofrequency lesion dimensions in deep and intramural ventricular substrate. Circ Arrhythm Electrophysiol. 2019;12:e007336.CrossRefPubMedPubMedCentral
23.
go back to reference Kugler JD, Danford DA, Deal BJ, Gillette PC, Perry JC, Silka MJ, Van Hare GF, Walsh EP. Radiofrequency catheter ablation for tachyarrhythmias in children and adolescents. N Engl J Med. 1994;330:1481–7.CrossRefPubMed Kugler JD, Danford DA, Deal BJ, Gillette PC, Perry JC, Silka MJ, Van Hare GF, Walsh EP. Radiofrequency catheter ablation for tachyarrhythmias in children and adolescents. N Engl J Med. 1994;330:1481–7.CrossRefPubMed
24.
go back to reference Aldhoon B, Wichterle D, Peichl P, Cihak R, Kautzner J. Complications of catheter ablation for atrial fibrillation in a high-volume centre with the use of intracardiac echocardiography. Europace. 2013;15:24–32.CrossRefPubMed Aldhoon B, Wichterle D, Peichl P, Cihak R, Kautzner J. Complications of catheter ablation for atrial fibrillation in a high-volume centre with the use of intracardiac echocardiography. Europace. 2013;15:24–32.CrossRefPubMed
25.
go back to reference Gaeta S, Bahnson TD. Impedance guided radiofrequency ablation for atrial fibrillation: something old is new again. J Cardiovasc Electrophysiol. 2016;27:1399–402.CrossRefPubMed Gaeta S, Bahnson TD. Impedance guided radiofrequency ablation for atrial fibrillation: something old is new again. J Cardiovasc Electrophysiol. 2016;27:1399–402.CrossRefPubMed
Metadata
Title
Impact of baseline impedance of pulmonary vein antrum on success of catheter ablation for paroxysmal atrial fibrillation guided by ablation index
Authors
Yuanjun Sun
Xianjie Xiao
Xiaomeng Yin
Lianjun Gao
Xiaohong Yu
Rongfeng Zhang
Zhongzhen Wang
Shiyu Dai
Yanzong Yang
Yunlong Xia
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Cardiovascular Disorders / Issue 1/2022
Electronic ISSN: 1471-2261
DOI
https://doi.org/10.1186/s12872-022-02530-y

Other articles of this Issue 1/2022

BMC Cardiovascular Disorders 1/2022 Go to the issue