Skip to main content
Top
Published in: Heart and Vessels 1/2022

01-01-2022 | Atrial Fibrillation | Original Article

Fluoroscopy and contrast media use in cryoballoon ablation of atrial fibrillation using a novel imaging system

Authors: Vincenzo Schillaci, Giuseppe Stabile, Alberto Arestia, Gergana Shopova, Alessia Agresta, Sara Poggi, Armando Salita, Carmine Romano, Carlo Maria Giannitti, Andrea Natalizia, Antonio De Simone, Francesco Solimene

Published in: Heart and Vessels | Issue 1/2022

Login to get access

Abstract

Pulmonary vein (PV) isolation using cryoballoon (CB) catheter is generally characterized by a high radiation and contrast media exposure. A new dielectric imaging system (KODEX–EPD imaging system) allows pulmonary vein (PV) occlusion assessment without dye use. The purpose of this study was to verify the feasibility of reducing the radiation and dye use during CB ablation in patients with atrial fibrillation (AF) using the new dielectric imaging system. In a retrospective, single center study, we enrolled 34 consecutive patients with paroxysmal AF divided in two groups: 17 patients in Conventional Group underwent the procedure under fluoroscopy guidance before the new system introduction, while 17 patient in KODEX–EPD Group underwent the procedure under fluoroscopy and KODEX–EPD imaging system guidance. There were no differences in any clinical and anatomical characteristics between the two study groups. Overall procedure time was comparable between the two groups (69 [IQR 63–98] min in Conventional Group vs. 65 [IQR 58–74] min in KODEX–EPD Group, p = 0.16), while fluoroscopy time (8 [IQR 5–9] min vs. 11 [IQR 9–12] min, p = 0.014) and dye use (35 [IQR 28–45] ml vs. 70 [IQR 57–83] ml, p < 0.001) were significantly lower in the KODEX–EPD Group. No 30-day complications were observed. At 12-month follow-up 7/37 (19%) patients had an atrial arrhythmias recurrence, without any difference between the two study groups (17.6% vs. 23.5%, p = 0.68). The use of a new dielectric imaging system allowed a significantly reduction in radiation exposure and dye use during CB ablation in patients with AF.
Literature
1.
go back to reference January CT, Wann LS, Alpert JS, Calkins H, Cigarroa JE, Cleveland JC Jr, Conti JB, Ellinor PT, Ezekowitz MD, Field ME, Murray KT, Sacco RL, Stevenson WG, Tchou PJ, Tracy CM, Yancy CW, American College of Cardiology/American Heart Association Task Force on Practice Guidelines (2014) 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol 64:e1-76CrossRef January CT, Wann LS, Alpert JS, Calkins H, Cigarroa JE, Cleveland JC Jr, Conti JB, Ellinor PT, Ezekowitz MD, Field ME, Murray KT, Sacco RL, Stevenson WG, Tchou PJ, Tracy CM, Yancy CW, American College of Cardiology/American Heart Association Task Force on Practice Guidelines (2014) 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol 64:e1-76CrossRef
2.
go back to reference Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B, Castella M, Diener HC, Heidbuchel H, Hendriks J, Hindricks G, Manolis AS, Oldgren J, Popescu BA, Schotten U, Van Putte B, Vardas P, Agewall S, Camm J, Esquivias GB, Budts W, Carerj S, Casselman F, Coca A, De Caterina R, Deftereos S, Dobrev D, Ferro JM, Filippatos G, Fitzsimons D, Gorenek B, Guenoun M, Hohnloser SH, Kolh P, Lip GY, Manolis A, McMurray J, Ponikowski P, Rosenhek R, Ruschitzka F, Savelieva I, Sharma S, Suwalski P, Tamargo JL, Taylor CJ, Van Gelder IC, Voors AA, Windecker S, Zamorano JL, Zeppenfeld K (2016) 2016 ESC guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Europace 18(11):1609–1678CrossRef Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B, Castella M, Diener HC, Heidbuchel H, Hendriks J, Hindricks G, Manolis AS, Oldgren J, Popescu BA, Schotten U, Van Putte B, Vardas P, Agewall S, Camm J, Esquivias GB, Budts W, Carerj S, Casselman F, Coca A, De Caterina R, Deftereos S, Dobrev D, Ferro JM, Filippatos G, Fitzsimons D, Gorenek B, Guenoun M, Hohnloser SH, Kolh P, Lip GY, Manolis A, McMurray J, Ponikowski P, Rosenhek R, Ruschitzka F, Savelieva I, Sharma S, Suwalski P, Tamargo JL, Taylor CJ, Van Gelder IC, Voors AA, Windecker S, Zamorano JL, Zeppenfeld K (2016) 2016 ESC guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Europace 18(11):1609–1678CrossRef
3.
go back to reference Luik A, Radzewitz A, Kieser M, Walter M, Bramlage P, Hörmann P, Schmidt K, Horn N, Brinkmeier-Theofanopoulou M, Kunzmann K, Riexinger T, Schymik G, Merkel M, Schmitt C (2015) Cryoballoon versus open irrigated radiofrequency ablation in patients with paroxysmal atrial fibrillation: the prospective, randomized, controlled noninferiority FreezeAF Study. Circulation 132(14):1311–1319CrossRef Luik A, Radzewitz A, Kieser M, Walter M, Bramlage P, Hörmann P, Schmidt K, Horn N, Brinkmeier-Theofanopoulou M, Kunzmann K, Riexinger T, Schymik G, Merkel M, Schmitt C (2015) Cryoballoon versus open irrigated radiofrequency ablation in patients with paroxysmal atrial fibrillation: the prospective, randomized, controlled noninferiority FreezeAF Study. Circulation 132(14):1311–1319CrossRef
4.
go back to reference Kuck KH, Brugada J, Fürnkranz A, Metzner A, Ouyang F, Chun KR, Elvan A, Arentz T, Bestehorn K, Pocock SJ, Albenque JP, Tondo C, FIRE AND ICE Investigators (2016) Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N Engl J Med 374(23):2235–2245CrossRef Kuck KH, Brugada J, Fürnkranz A, Metzner A, Ouyang F, Chun KR, Elvan A, Arentz T, Bestehorn K, Pocock SJ, Albenque JP, Tondo C, FIRE AND ICE Investigators (2016) Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N Engl J Med 374(23):2235–2245CrossRef
5.
go back to reference Romanov A, Dichterman E, Schwartz Y, Ibragimov Z, Ben-David Y, Rodriguez H, Pokushalov E, Siddiqui UR, Kadlec A, Ben-Haim SA (2019) High-resolution, real-time, and nonfluoroscopic 3-dimensional cardiac imaging and catheter navigation in humans using a novel dielectric-based system. Heart Rhythm 16(12):1883–1889CrossRef Romanov A, Dichterman E, Schwartz Y, Ibragimov Z, Ben-David Y, Rodriguez H, Pokushalov E, Siddiqui UR, Kadlec A, Ben-Haim SA (2019) High-resolution, real-time, and nonfluoroscopic 3-dimensional cardiac imaging and catheter navigation in humans using a novel dielectric-based system. Heart Rhythm 16(12):1883–1889CrossRef
6.
go back to reference Nicholls M (2019) KODEX-EPD mapping for AF ablation. Eur Heart J 40(36):3003–3005CrossRef Nicholls M (2019) KODEX-EPD mapping for AF ablation. Eur Heart J 40(36):3003–3005CrossRef
7.
go back to reference Cauti FM, Solimene F, Stabile G, Polselli M, Schillaci V, Arestia A, Shopova G, Iaia L, Giannitti CM, Rossi P, Bianchi S (2020) Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation. Pacing Clin Electrophysiol 44(1):63–70CrossRef Cauti FM, Solimene F, Stabile G, Polselli M, Schillaci V, Arestia A, Shopova G, Iaia L, Giannitti CM, Rossi P, Bianchi S (2020) Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation. Pacing Clin Electrophysiol 44(1):63–70CrossRef
8.
go back to reference Maurer T, Mathew S, Schlüter M, Lemes C, Riedl J, Inaba O, Hashiguchi N, Reißmann B, Fink T, Rottner L, Rillig A, Metzner A, Ouyang F, Kuck KH (2019) High-resolution imaging of LA anatomy using a novel wide-band dielectric mapping system: first clinical experience. JACC Clin Electrophysiol 5(11):1344–1354CrossRef Maurer T, Mathew S, Schlüter M, Lemes C, Riedl J, Inaba O, Hashiguchi N, Reißmann B, Fink T, Rottner L, Rillig A, Metzner A, Ouyang F, Kuck KH (2019) High-resolution imaging of LA anatomy using a novel wide-band dielectric mapping system: first clinical experience. JACC Clin Electrophysiol 5(11):1344–1354CrossRef
9.
go back to reference Bertaglia E, Stabile G, Senatore G, Zoppo F, Turco P, Amellone C, De Simone A, Fazzari M, Pascotto P (2005) Predictive value of early atrial fibrillation recurrence after circumferential pulmonary vein ablation. Pacing Clin Electrophysiol 28(5):366–371CrossRef Bertaglia E, Stabile G, Senatore G, Zoppo F, Turco P, Amellone C, De Simone A, Fazzari M, Pascotto P (2005) Predictive value of early atrial fibrillation recurrence after circumferential pulmonary vein ablation. Pacing Clin Electrophysiol 28(5):366–371CrossRef
10.
go back to reference Stabile G, Iacopino S, Verlato R, Arena G, Pieragnoli P, Molon G, Manfrin M, Rovaris G, Curnis A, Bertaglia E, Mantica M, Sciarra L, Landolina M, Tondo C (2020) Predictive role of early recurrence of atrial fibrillation after cryoballoon ablation. Europace 22(12):1798–1804CrossRef Stabile G, Iacopino S, Verlato R, Arena G, Pieragnoli P, Molon G, Manfrin M, Rovaris G, Curnis A, Bertaglia E, Mantica M, Sciarra L, Landolina M, Tondo C (2020) Predictive role of early recurrence of atrial fibrillation after cryoballoon ablation. Europace 22(12):1798–1804CrossRef
11.
go back to reference Chen S, Schmidt B, Bordignon S, Bologna F, Perrotta L, Nagase T, Chun KRJ (2018) Atrial fibrillation ablation using cryoballoon technology: recent advances and practical techniques. J Cardiovasc Electrophysiol 29(6):932–943CrossRef Chen S, Schmidt B, Bordignon S, Bologna F, Perrotta L, Nagase T, Chun KRJ (2018) Atrial fibrillation ablation using cryoballoon technology: recent advances and practical techniques. J Cardiovasc Electrophysiol 29(6):932–943CrossRef
12.
go back to reference Squara F, Zhao A, Marijon E, Latcu DG, Providencia R, Di Giovanni G, Jauvert G, Jourda F, Chierchia GB, De Asmundis C, Ciconte G, Alonso C, Grimard C, Boveda S, Cauchemez B, Saoudi N, Brugada P, Albenque JP, Thomas O (2015) Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation. Europace 17(5):718–724CrossRef Squara F, Zhao A, Marijon E, Latcu DG, Providencia R, Di Giovanni G, Jauvert G, Jourda F, Chierchia GB, De Asmundis C, Ciconte G, Alonso C, Grimard C, Boveda S, Cauchemez B, Saoudi N, Brugada P, Albenque JP, Thomas O (2015) Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation. Europace 17(5):718–724CrossRef
13.
go back to reference Fortuni F, Casula M, Sanzo A, Angelini F, Cornara S, Somaschini A, Mugnai G, Rordorf R, De Ferrari GM (2020) Meta-analysis comparing cryoballoon versus radiofrequency as first ablation procedure for atrial fibrillation. Am J Cardiol 125(8):1170–1179CrossRef Fortuni F, Casula M, Sanzo A, Angelini F, Cornara S, Somaschini A, Mugnai G, Rordorf R, De Ferrari GM (2020) Meta-analysis comparing cryoballoon versus radiofrequency as first ablation procedure for atrial fibrillation. Am J Cardiol 125(8):1170–1179CrossRef
14.
go back to reference Sarkozy A, De Potter T, Heidbuchel H, Ernst S, Kosiuk J, Vano E, Picano E, Arbelo E, Tedrow U, ESC Scientific Document Group (2017) Occupational radiation exposure in the electrophysiology laboratory with a focus on personnel with reproductive potential and during pregnancy: a European Heart Rhythm Association (EHRA) consensus document endorsed by the Heart Rhythm Society (HRS). Europace 19(12):1909–1922CrossRef Sarkozy A, De Potter T, Heidbuchel H, Ernst S, Kosiuk J, Vano E, Picano E, Arbelo E, Tedrow U, ESC Scientific Document Group (2017) Occupational radiation exposure in the electrophysiology laboratory with a focus on personnel with reproductive potential and during pregnancy: a European Heart Rhythm Association (EHRA) consensus document endorsed by the Heart Rhythm Society (HRS). Europace 19(12):1909–1922CrossRef
15.
go back to reference Siklódy CH, Minners J, Allgeier M, Allgeier HJ, Jander N, Weber R, Schiebeling-Römer J, Neumann FJ, Kalusche D, Arentz T (2009) Cryoballoon pulmonary vein isolation guided by transesophageal echocardiography: novel aspects on an emerging ablation technique. J Cardiovasc Electrophysiol 20(11):1197–1202CrossRef Siklódy CH, Minners J, Allgeier M, Allgeier HJ, Jander N, Weber R, Schiebeling-Römer J, Neumann FJ, Kalusche D, Arentz T (2009) Cryoballoon pulmonary vein isolation guided by transesophageal echocardiography: novel aspects on an emerging ablation technique. J Cardiovasc Electrophysiol 20(11):1197–1202CrossRef
16.
go back to reference Ottaviano L, Chierchia GB, Bregasi A, Bruno N, Antonelli A, Alsheraei ATA, Porrini AM, Gronda E, Donatelli F, Duijnhower AL, Brugada P, Montenero AS (2013) Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography: a feasibility study. Europace 15(7):944–950CrossRef Ottaviano L, Chierchia GB, Bregasi A, Bruno N, Antonelli A, Alsheraei ATA, Porrini AM, Gronda E, Donatelli F, Duijnhower AL, Brugada P, Montenero AS (2013) Cryoballoon ablation for atrial fibrillation guided by real-time three-dimensional transoesophageal echocardiography: a feasibility study. Europace 15(7):944–950CrossRef
17.
go back to reference Safavi-Naeini P, Shanoon F, Nazeri A, Rasekh A, Saeed M, Razavi M, Massumi A (2014) Cryoballoon pressure waveform change during balloon inflation is not a reliable predictor of adequate pulmonary vein occlusion. Pacing Clin Electrophysiol 37(12):1702–1707CrossRef Safavi-Naeini P, Shanoon F, Nazeri A, Rasekh A, Saeed M, Razavi M, Massumi A (2014) Cryoballoon pressure waveform change during balloon inflation is not a reliable predictor of adequate pulmonary vein occlusion. Pacing Clin Electrophysiol 37(12):1702–1707CrossRef
18.
go back to reference Rubesch-Kütemeyer V, Fischbach T, Guckel D, Körber B, Horstkotte D, Gutleben KJ, Nölker G (2020) Long-term development of radiation exposure, fluoroscopy time and contrast media use in daily routine in cryoballoon ablations after implementation of intracardiac echocardiography and other radioprotective measures: experiences from a large single-centre cohort. J Interv Card Electrophysiol 58(2):169–175CrossRef Rubesch-Kütemeyer V, Fischbach T, Guckel D, Körber B, Horstkotte D, Gutleben KJ, Nölker G (2020) Long-term development of radiation exposure, fluoroscopy time and contrast media use in daily routine in cryoballoon ablations after implementation of intracardiac echocardiography and other radioprotective measures: experiences from a large single-centre cohort. J Interv Card Electrophysiol 58(2):169–175CrossRef
19.
go back to reference Maalouf J, Whiteside HL, Pillai A, Omar A, Berman A, Saba S, Hreibe H (2020) Reduction of radiation and contrast agent exposure in a cryoballoon ablation procedure with integration of electromagnetic mapping and intracardiac echocardiography: a single center experience. J Interv Card Electrophysiol 59(3):545–550CrossRef Maalouf J, Whiteside HL, Pillai A, Omar A, Berman A, Saba S, Hreibe H (2020) Reduction of radiation and contrast agent exposure in a cryoballoon ablation procedure with integration of electromagnetic mapping and intracardiac echocardiography: a single center experience. J Interv Card Electrophysiol 59(3):545–550CrossRef
Metadata
Title
Fluoroscopy and contrast media use in cryoballoon ablation of atrial fibrillation using a novel imaging system
Authors
Vincenzo Schillaci
Giuseppe Stabile
Alberto Arestia
Gergana Shopova
Alessia Agresta
Sara Poggi
Armando Salita
Carmine Romano
Carlo Maria Giannitti
Andrea Natalizia
Antonio De Simone
Francesco Solimene
Publication date
01-01-2022
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 1/2022
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-021-01902-2

Other articles of this Issue 1/2022

Heart and Vessels 1/2022 Go to the issue