Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 2/2010

01-12-2010 | Original Paper

Assessment of global function of left ventricle with dual-source CT in patients with severe arrhythmia: a comparison with the use of two-dimensional transthoracic echocardiography

Authors: Song Soo Kim, Sung Min Ko, Meong Gun Song, Joon Suk Kim

Published in: The International Journal of Cardiovascular Imaging | Special Issue 2/2010

Login to get access

Abstract

To evaluate the agreement between dual-source computed tomography (DSCT) and two-dimensional transthoracic echocardiography (2D-TTE) with respect to the assessment of global left ventricular (LV) function in patients with severe arrhythmia. With 2D-TTE serving as the reference method, we performed both DSCT and 2D-TTE, at an interval of less than 2 days, in 54 patients with severe arrhythmia (average heart rate difference >30 beats per min) before open heart surgery for evaluation of valvular heart disease (VHD) and coronary artery disease. DSCT was performed using retrospective electrocardiography (ECG) without dose modulation. Ten phases of the cardiac cycle were analyzed for identification of end-diastolic and end-systolic phases with ECG-editing. Pearson’s correlation coefficient (r) and Bland–Altman analysis were used to determine agreement for parameters of LV global function. Correlation between DSCT and 2D-TTE measurements was good or excellent in terms of the values of the LV ejection fraction (51.0 ± 11.4% vs. 55.8 ± 11.6%; r = 0.8), LV end-diastolic volume (179.5 ± 98.6 ml vs. 152.1 ± 73.8 ml; r = 0.95), LV end-systolic volume (90.7 ± 60.7 ml vs. 69.1 ± 46.8 ml; r = 0.90), and LV stroke volume (89.0 ± 48.1 ml vs. 82.9 ± 37.3 ml; r = 0.89). Left ventricular ejection fraction measured using DSCT was less than that measured using 2D-TTE by an average of −4.8 ± 7.3%. Dual-source CT with ECG editing can provide results comparable to those of 2D-TTE for assessment of LV global function in patients with severe arrhythmia.
Literature
1.
go back to reference Schocken DD, Arrieta MI, Leaverton PE et al (1992) Prevalence and mortality rate of congestive heart failure in the United States. J Am Coll Cardiol 20(2):301–306CrossRefPubMed Schocken DD, Arrieta MI, Leaverton PE et al (1992) Prevalence and mortality rate of congestive heart failure in the United States. J Am Coll Cardiol 20(2):301–306CrossRefPubMed
2.
go back to reference White HD, Norris RM, Brown MA et al (1987) Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 76(1):44–51PubMed White HD, Norris RM, Brown MA et al (1987) Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 76(1):44–51PubMed
3.
go back to reference Gerber TC, Behrenbeck T, Allison T et al (1999) Comparison of measurement of left ventricular ejection fraction by Tc-99 m sestamibi first-pass angiography with electron beam computed tomography in patients with anterior wall acute myocardial infarction. Am J Cardiol 83(7):1022–1026CrossRefPubMed Gerber TC, Behrenbeck T, Allison T et al (1999) Comparison of measurement of left ventricular ejection fraction by Tc-99 m sestamibi first-pass angiography with electron beam computed tomography in patients with anterior wall acute myocardial infarction. Am J Cardiol 83(7):1022–1026CrossRefPubMed
4.
go back to reference Fuster V, Rydén LE, Cannom DS et al (2006) ACC/AHA/ESC 2006 Guidelines for the Management of Patients with Atrial Fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Circulation 114(7):e257–e354CrossRefPubMed Fuster V, Rydén LE, Cannom DS et al (2006) ACC/AHA/ESC 2006 Guidelines for the Management of Patients with Atrial Fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Circulation 114(7):e257–e354CrossRefPubMed
5.
go back to reference Bellenger NG, Burgess MI, Ray SG et al (2000) Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J 21(16):1387–1396CrossRefPubMed Bellenger NG, Burgess MI, Ray SG et al (2000) Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J 21(16):1387–1396CrossRefPubMed
6.
go back to reference Schiller NB, Acquatella H, Ports TA et al (1979) Left ventricular volume from paired biplane two-dimensional echocardiography. Circulation 60(3):547–555PubMed Schiller NB, Acquatella H, Ports TA et al (1979) Left ventricular volume from paired biplane two-dimensional echocardiography. Circulation 60(3):547–555PubMed
7.
go back to reference Pons-Lladó G (2005) Assessment of cardiac function by CMR. Eur Radiol 15(Suppl 2):B23–B32PubMed Pons-Lladó G (2005) Assessment of cardiac function by CMR. Eur Radiol 15(Suppl 2):B23–B32PubMed
8.
go back to reference Orakzai SH, Orakzai RH, Nasir K et al (2006) Assessment of cardiac function using multidetector row computed tomography. J Comput Assist Tomogr 30(4):555–563CrossRefPubMed Orakzai SH, Orakzai RH, Nasir K et al (2006) Assessment of cardiac function using multidetector row computed tomography. J Comput Assist Tomogr 30(4):555–563CrossRefPubMed
9.
go back to reference Juergens KU, Fischbach R (2006) Left ventricular function studied with MDCT. Eur Radiol 16(2):342–357CrossRefPubMed Juergens KU, Fischbach R (2006) Left ventricular function studied with MDCT. Eur Radiol 16(2):342–357CrossRefPubMed
10.
go back to reference Mahnken AH, Mühlenbruch G, Gunther RW et al (2007) Cardiac CT: coronary arteries and beyond. Eur Radiol 17(4):994–1008CrossRefPubMed Mahnken AH, Mühlenbruch G, Gunther RW et al (2007) Cardiac CT: coronary arteries and beyond. Eur Radiol 17(4):994–1008CrossRefPubMed
11.
go back to reference Ko SM, Kim YJ, Park JH et al (2010) Assessment of left ventricular ejection fraction and regional wall motion with 64-slice multidetector CT: a comparison with two-dimensional transthoracic echocardiography. Br J Radiol 83(985):28–34CrossRefPubMed Ko SM, Kim YJ, Park JH et al (2010) Assessment of left ventricular ejection fraction and regional wall motion with 64-slice multidetector CT: a comparison with two-dimensional transthoracic echocardiography. Br J Radiol 83(985):28–34CrossRefPubMed
12.
go back to reference Dewey M, Müller M, Eddicks S et al (2006) Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography: comparison with magnetic resonance imaging. J Am Coll Cardiol 48(10):2034–2044CrossRefPubMed Dewey M, Müller M, Eddicks S et al (2006) Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography: comparison with magnetic resonance imaging. J Am Coll Cardiol 48(10):2034–2044CrossRefPubMed
13.
go back to reference Salm LP, Schuijf JD, de Roos A et al (2006) Global and regional left ventricular function assessment with 16-detector row CT: comparison with echocardiography and cardiovascular magnetic resonance. Eur J Echocardiogr 7(4):308–314CrossRefPubMed Salm LP, Schuijf JD, de Roos A et al (2006) Global and regional left ventricular function assessment with 16-detector row CT: comparison with echocardiography and cardiovascular magnetic resonance. Eur J Echocardiogr 7(4):308–314CrossRefPubMed
14.
go back to reference Mahnken AH, Bruners P, Stanzel S et al (2009) Functional imaging in the assessment of myocardial infarction: MR imaging vs. MDCT vs. SPECT. Eur J Radiol 71(3):480–485CrossRefPubMed Mahnken AH, Bruners P, Stanzel S et al (2009) Functional imaging in the assessment of myocardial infarction: MR imaging vs. MDCT vs. SPECT. Eur J Radiol 71(3):480–485CrossRefPubMed
15.
go back to reference Schepis T, Gaemperli O, Koepfli P et al (2006) Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function. J Nucl Med 47(8):1288–1294PubMed Schepis T, Gaemperli O, Koepfli P et al (2006) Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function. J Nucl Med 47(8):1288–1294PubMed
16.
go back to reference Wu YW, Tadamura E, Yamamuro M et al (2008) Estimation of global and regional cardiac function using 64-slice computed tomography: a comparison study with echocardiography, gated-SPECT and cardiovascular magnetic resonance. Int J Cardiol 128(1):69–76CrossRefPubMed Wu YW, Tadamura E, Yamamuro M et al (2008) Estimation of global and regional cardiac function using 64-slice computed tomography: a comparison study with echocardiography, gated-SPECT and cardiovascular magnetic resonance. Int J Cardiol 128(1):69–76CrossRefPubMed
17.
go back to reference Wu YW, Tadamura E, Kanao S et al (2008) Left ventricular functional analysis using 64-slice multidetector row computed tomography: comparison with left ventriculography and cardiovascular magnetic resonance. Cardiology 109(2):135–142CrossRefPubMed Wu YW, Tadamura E, Kanao S et al (2008) Left ventricular functional analysis using 64-slice multidetector row computed tomography: comparison with left ventriculography and cardiovascular magnetic resonance. Cardiology 109(2):135–142CrossRefPubMed
18.
go back to reference Henneman MM, Schuijf JD, Jukema JW et al (2006) Assessment of global and regional left ventricular function and volumes with 64-slice MSCT: a comparison with 2D echocardiography. J Nucl Cardiol 13(4):480–487CrossRefPubMed Henneman MM, Schuijf JD, Jukema JW et al (2006) Assessment of global and regional left ventricular function and volumes with 64-slice MSCT: a comparison with 2D echocardiography. J Nucl Cardiol 13(4):480–487CrossRefPubMed
19.
go back to reference Bansal D, Singh RM, Sarkar M et al (2008) Assessment of left ventricular function: comparison of cardiac multidetector-row computed tomography with two-dimension standard echocardiography for assessment of left ventricular function. Int J Cardiovasc Imaging 24(3):317–325CrossRefPubMed Bansal D, Singh RM, Sarkar M et al (2008) Assessment of left ventricular function: comparison of cardiac multidetector-row computed tomography with two-dimension standard echocardiography for assessment of left ventricular function. Int J Cardiovasc Imaging 24(3):317–325CrossRefPubMed
20.
go back to reference Brodoefel H, Burgstahler C, Tsiflikas I et al (2008) Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 247(2):346–355CrossRefPubMed Brodoefel H, Burgstahler C, Tsiflikas I et al (2008) Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology 247(2):346–355CrossRefPubMed
21.
go back to reference Gottdiener JS, Bednarz J, Devereux R et al (2004) American Society of Echocardiography recommendations for use of echocardiography in clinical trials. J Am Soc Echocardiogr 17(10):1086–1119PubMed Gottdiener JS, Bednarz J, Devereux R et al (2004) American Society of Echocardiography recommendations for use of echocardiography in clinical trials. J Am Soc Echocardiogr 17(10):1086–1119PubMed
22.
go back to reference Schiller NB, Shah PM, Crawford M et al (1989) Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, subcommittee on quantitation of two-dimensional echocardiograms. J Am Soc Echocardiogr 2(5):358–367PubMed Schiller NB, Shah PM, Crawford M et al (1989) Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, subcommittee on quantitation of two-dimensional echocardiograms. J Am Soc Echocardiogr 2(5):358–367PubMed
23.
go back to reference Folland ED, Parisi AF, Moynihan PF et al (1979) Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation 60(4):760–766PubMed Folland ED, Parisi AF, Moynihan PF et al (1979) Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation 60(4):760–766PubMed
24.
go back to reference Tops LF, Krishnàn SC, Schuijf JD et al (2008) Noncoronary applications of cardiac multidetector row computed tomography. JACC Cardiovasc Imaging 1(1):94–106CrossRefPubMed Tops LF, Krishnàn SC, Schuijf JD et al (2008) Noncoronary applications of cardiac multidetector row computed tomography. JACC Cardiovasc Imaging 1(1):94–106CrossRefPubMed
25.
go back to reference Johnson TR, Nikolaou K, Wintersperger BJ et al (2006) Dual-source CT cardiac imaging: initial experience. Eur Radiol 16:1409–1415CrossRefPubMed Johnson TR, Nikolaou K, Wintersperger BJ et al (2006) Dual-source CT cardiac imaging: initial experience. Eur Radiol 16:1409–1415CrossRefPubMed
26.
go back to reference Rist C, Johnson TR, Becker A et al (2007) Dual-source cardiac CT imaging with improved temporal resolution: impact on image quality and analysis of left ventricular function. Radiologe 47(4):287–290, 292–294 [German] Rist C, Johnson TR, Becker A et al (2007) Dual-source cardiac CT imaging with improved temporal resolution: impact on image quality and analysis of left ventricular function. Radiologe 47(4):287–290, 292–294 [German]
27.
go back to reference Gosselink AT, Blanksma PK, Crijns HJ et al (1995) Left ventricular beat-to-beat performance in atrial fibrillation: contribution of Frank-Starling mechanism after short rather than long RR intervals. J Am Coll Cardiol 26(6):1516–1521CrossRefPubMed Gosselink AT, Blanksma PK, Crijns HJ et al (1995) Left ventricular beat-to-beat performance in atrial fibrillation: contribution of Frank-Starling mechanism after short rather than long RR intervals. J Am Coll Cardiol 26(6):1516–1521CrossRefPubMed
28.
go back to reference Mahnken AH, Spuentrup E, Niethammer M et al (2003) Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI. Acta Radiol 44(6):604–611CrossRefPubMed Mahnken AH, Spuentrup E, Niethammer M et al (2003) Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI. Acta Radiol 44(6):604–611CrossRefPubMed
29.
go back to reference Juergens KU, Maintz D, Grude M et al (2005) Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements? Eur Radiol 15(1):111–117CrossRefPubMed Juergens KU, Maintz D, Grude M et al (2005) Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements? Eur Radiol 15(1):111–117CrossRefPubMed
30.
go back to reference Mahnken AH, Hohl C, Suess C et al (2006) Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study. Invest Radiol 41(5):429–435CrossRefPubMed Mahnken AH, Hohl C, Suess C et al (2006) Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study. Invest Radiol 41(5):429–435CrossRefPubMed
31.
go back to reference Mahnken AH, Bruder H, Suess C et al (2007) Dual-source computed tomography for assessing cardiac function: a phantom study. Invest Radiol 42(7):491–498CrossRefPubMed Mahnken AH, Bruder H, Suess C et al (2007) Dual-source computed tomography for assessing cardiac function: a phantom study. Invest Radiol 42(7):491–498CrossRefPubMed
32.
go back to reference Bastarrika G, De Cecco CN, Arraiza M et al (2008) Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates. AJR Am J Roentgenol 191:448–454CrossRefPubMed Bastarrika G, De Cecco CN, Arraiza M et al (2008) Dual-source CT for visualization of the coronary arteries in heart transplant patients with high heart rates. AJR Am J Roentgenol 191:448–454CrossRefPubMed
33.
go back to reference Matt D, Scheffel H, Leschka S et al (2007) Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR Am J Roentgenol 189(3):567–573CrossRefPubMed Matt D, Scheffel H, Leschka S et al (2007) Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR Am J Roentgenol 189(3):567–573CrossRefPubMed
34.
go back to reference Weustink AC, Neefjes LA, Kyrzopoulos S et al (2009) Impact of heart rate frequency and variability on radiation exposure, image quality, and diagnostic performance in dual-source spiral CT coronary angiography. Radiology 253(3):672–680CrossRefPubMed Weustink AC, Neefjes LA, Kyrzopoulos S et al (2009) Impact of heart rate frequency and variability on radiation exposure, image quality, and diagnostic performance in dual-source spiral CT coronary angiography. Radiology 253(3):672–680CrossRefPubMed
35.
go back to reference Gutiérrez-Chico JL, Zamorano JL, Pérez de Isla L et al (2005) Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies. Am J Cardiol 95(6):809–813CrossRefPubMed Gutiérrez-Chico JL, Zamorano JL, Pérez de Isla L et al (2005) Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies. Am J Cardiol 95(6):809–813CrossRefPubMed
36.
go back to reference Ko SM, Kim NR, Kim DH et al (2010) Assessment of image quality and radiation dose in prospective ECG-triggered coronary CT angiography compared with retrospective ECG-gated coronary CT angiography. Int J Cardiovasc Imaging 26 (Suppl 1):93–101 Ko SM, Kim NR, Kim DH et al (2010) Assessment of image quality and radiation dose in prospective ECG-triggered coronary CT angiography compared with retrospective ECG-gated coronary CT angiography. Int J Cardiovasc Imaging 26 (Suppl 1):93–101
37.
go back to reference Husmann L, Valenta I, Gaemperli O et al (2008) Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 29(2):191–197CrossRefPubMed Husmann L, Valenta I, Gaemperli O et al (2008) Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 29(2):191–197CrossRefPubMed
38.
go back to reference Stolzmann P, Leschka S, Scheffel H et al (2008) Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 249(1):71–80CrossRefPubMed Stolzmann P, Leschka S, Scheffel H et al (2008) Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 249(1):71–80CrossRefPubMed
39.
go back to reference Leschka S, Scheffel H, Husmann L et al (2008) Effect of decrease in heart rate variability on the diagnostic accuracy of 64-MDCT coronary angiography. AJR Am J Roentgenol 190(6):1583–1590CrossRefPubMed Leschka S, Scheffel H, Husmann L et al (2008) Effect of decrease in heart rate variability on the diagnostic accuracy of 64-MDCT coronary angiography. AJR Am J Roentgenol 190(6):1583–1590CrossRefPubMed
40.
go back to reference Yamakado T, Okano S, Higashiyama S et al (1985) Effects of nitroglycerin on left ventricular systolic, diastolic and regional myocardial function in patients with coronary artery disease. J Cardiogr 15(2):273–284 JapanesePubMed Yamakado T, Okano S, Higashiyama S et al (1985) Effects of nitroglycerin on left ventricular systolic, diastolic and regional myocardial function in patients with coronary artery disease. J Cardiogr 15(2):273–284 JapanesePubMed
Metadata
Title
Assessment of global function of left ventricle with dual-source CT in patients with severe arrhythmia: a comparison with the use of two-dimensional transthoracic echocardiography
Authors
Song Soo Kim
Sung Min Ko
Meong Gun Song
Joon Suk Kim
Publication date
01-12-2010
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue Special Issue 2/2010
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-010-9692-2

Other articles of this Special Issue 2/2010

The International Journal of Cardiovascular Imaging 2/2010 Go to the issue