Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 2/2019

01-04-2019 | Original Research

Assessing the correct inflation of the endotracheal tube cuff: a larger pilot balloon increases the sensitivity of the ‘finger-pressure’ technique, but it remains poorly reliable in clinical practice

Authors: Antonio Pisano, Luigi Verniero, Nicola Galdieri, Antonio Corcione

Published in: Journal of Clinical Monitoring and Computing | Issue 2/2019

Login to get access

Abstract

The pilot balloon palpation (or ‘finger-pressure’) method is still widely used to assess the endotracheal tube cuff inflation, despite consistent evidence of its poor sensitivity in recognizing cuff overinflation. It was recently speculated that this may be related to the lower wall tension (due to the smaller radius) of the pilot balloon as compared with the cuff, according to Laplace’s law. To verify this hypothesis and, secondarily, to assess whether the use of a ‘large’ pilot balloon (identical to the cuff) increases the reliability of this technique, 62 anesthetists (41 experienced anesthesiologists and 21 residents) were asked to estimate the pressure of a cuff inflated to 88 mmHg into a simulated trachea by feeling both a usual and a modified ‘large’ pilot balloon. A similar test was repeated at 40 mmHg. After palpation of the usual pilot balloon, only 35% of participants (49% of experienced anesthesiologists and 10% of residents) recognized considerable overinflation (88 mmHg), as compared with 87% of participants (95% of experienced anesthesiologists and 71% of residents) after palpation of the ‘large’ pilot balloon. Moreover, 89% of participants (85% of experienced anesthesiologists and 95% of residents) believed that pressure was higher in the ‘large’ balloon than in the normal one. However, only 32% of participants (51% of experienced anesthesiologists and none of residents) recognized slight overinflation (40 mmHg) after feeling the ‘large’ balloon. The pilot balloon size affects the sensitivity of the ‘finger-pressure’ technique, but it remains poorly reliable with a larger pilot balloon.
Literature
1.
go back to reference Liu J, Zhang X, Gong W, Li S, Wang F, Fu S, Zhang M, Hang Y. Correlations between controlled endotracheal tube cuff pressure and postprocedural complications: a multicenter study. Anesth Analg. 2010;111(5):1133–7.CrossRefPubMed Liu J, Zhang X, Gong W, Li S, Wang F, Fu S, Zhang M, Hang Y. Correlations between controlled endotracheal tube cuff pressure and postprocedural complications: a multicenter study. Anesth Analg. 2010;111(5):1133–7.CrossRefPubMed
2.
go back to reference Efrati S, Bolotin G, Levi L, Zaaroor M, Guralnik L, Weksler N, et al Levinger U, Soroksky A, Denman WT, Gurman GM. Optimization of endotracheal tube cuff pressure by monitoring CO2 levels in the subglottic space in mechanically ventilated patients: a randomized controlled trial. Anesth Analg. 2017;125(4):1309–15.CrossRefPubMed Efrati S, Bolotin G, Levi L, Zaaroor M, Guralnik L, Weksler N, et al Levinger U, Soroksky A, Denman WT, Gurman GM. Optimization of endotracheal tube cuff pressure by monitoring CO2 levels in the subglottic space in mechanically ventilated patients: a randomized controlled trial. Anesth Analg. 2017;125(4):1309–15.CrossRefPubMed
3.
go back to reference Hockey CA, van Zundert AA, Paratz JD. Does objective measurement of tracheal tube cuff pressures minimise adverse effects and maintain accurate cuff pressures? A systematic review and meta-analysis. Anaesth Intensive Care. 2016;44(5):560–70.CrossRef Hockey CA, van Zundert AA, Paratz JD. Does objective measurement of tracheal tube cuff pressures minimise adverse effects and maintain accurate cuff pressures? A systematic review and meta-analysis. Anaesth Intensive Care. 2016;44(5):560–70.CrossRef
4.
go back to reference Giusti GD, Rogari C, Gili A, Nisi F. Cuff pressure monitoring by manual palpation in intubated patients: how accurate is it? A manikin simulation study. Aust Crit Care. 2017;30(4):234–8.CrossRefPubMed Giusti GD, Rogari C, Gili A, Nisi F. Cuff pressure monitoring by manual palpation in intubated patients: how accurate is it? A manikin simulation study. Aust Crit Care. 2017;30(4):234–8.CrossRefPubMed
5.
go back to reference Michlig SA. Anaesthetic staff cannot identify extremely high tracheal tube cuff pressures by palpation of the pilot balloon. Br J Anaesth. 2013;111(2):300–1.CrossRefPubMed Michlig SA. Anaesthetic staff cannot identify extremely high tracheal tube cuff pressures by palpation of the pilot balloon. Br J Anaesth. 2013;111(2):300–1.CrossRefPubMed
6.
go back to reference Sole ML, Penoyer DA, Su X, Jimenez E, Kalita SJ, Poalillo E, Byers JF, Bennett M, Ludy JE. Assessment of endotracheal cuff pressure by continuous monitoring: a pilot study. Am J Crit Care. 2009;18:133–43.CrossRefPubMed Sole ML, Penoyer DA, Su X, Jimenez E, Kalita SJ, Poalillo E, Byers JF, Bennett M, Ludy JE. Assessment of endotracheal cuff pressure by continuous monitoring: a pilot study. Am J Crit Care. 2009;18:133–43.CrossRefPubMed
7.
go back to reference Svenson JE, Lindsay MB, O’Connor JE. Endotracheal intracuff pressures in the ED and prehospital setting: is there a problem? Am J Emerg Med. 2007;25:53–6.CrossRefPubMed Svenson JE, Lindsay MB, O’Connor JE. Endotracheal intracuff pressures in the ED and prehospital setting: is there a problem? Am J Emerg Med. 2007;25:53–6.CrossRefPubMed
8.
go back to reference Janossy KM, Pullen J, Young D, Bell G. The effect of pilot balloon design on estimation of safe tracheal tube cuff pressure. Anaesthesia. 2010;65(8):785–91.CrossRefPubMed Janossy KM, Pullen J, Young D, Bell G. The effect of pilot balloon design on estimation of safe tracheal tube cuff pressure. Anaesthesia. 2010;65(8):785–91.CrossRefPubMed
9.
go back to reference Hoffman RJ, Rarwani V, Hahn IH. Experienced emergency medicine physicians cannot safely inflate or estimate endotracheal tube cuff pressure using standard techniques. Am J Emerg Med. 2006;24:139–42.CrossRefPubMed Hoffman RJ, Rarwani V, Hahn IH. Experienced emergency medicine physicians cannot safely inflate or estimate endotracheal tube cuff pressure using standard techniques. Am J Emerg Med. 2006;24:139–42.CrossRefPubMed
10.
go back to reference Pisano A. Pitfalls from physics: why we can’t “feel” the tube cuff pressure with our fingers. Anesth Analg. 2017;124(4):1368.CrossRefPubMed Pisano A. Pitfalls from physics: why we can’t “feel” the tube cuff pressure with our fingers. Anesth Analg. 2017;124(4):1368.CrossRefPubMed
11.
go back to reference Pisano A. Bubbles, tracheal tube cuffs, and reservoir bags: surface tension and Laplace’s law. In: Physics for anesthesiologists. Cham: Springer; 2017. pp. 33–43.CrossRef Pisano A. Bubbles, tracheal tube cuffs, and reservoir bags: surface tension and Laplace’s law. In: Physics for anesthesiologists. Cham: Springer; 2017. pp. 33–43.CrossRef
12.
go back to reference Pisano A. Toothpaste, sea deeps, and invasive pressure monitoring: Stevin’s law and Pascal’s principle. In: Physics for anesthesiologists. Cham: Springer; 2017. pp. 65–73.CrossRef Pisano A. Toothpaste, sea deeps, and invasive pressure monitoring: Stevin’s law and Pascal’s principle. In: Physics for anesthesiologists. Cham: Springer; 2017. pp. 65–73.CrossRef
13.
go back to reference Özcan ATD, Döğer C, But A, Kutlu I, Aksoy ŞM. Comparison of endotracheal tube cuff pressure values before and after training seminar. J Clin Monit Comput. 2018;32(3):527–31.CrossRefPubMed Özcan ATD, Döğer C, But A, Kutlu I, Aksoy ŞM. Comparison of endotracheal tube cuff pressure values before and after training seminar. J Clin Monit Comput. 2018;32(3):527–31.CrossRefPubMed
14.
go back to reference Efrati S, Deutsch I, Gurman GM. Endotracheal tube cuff-small important part of a big issue. J Clin Monit Comput. 2012;26(1):53–60.CrossRefPubMed Efrati S, Deutsch I, Gurman GM. Endotracheal tube cuff-small important part of a big issue. J Clin Monit Comput. 2012;26(1):53–60.CrossRefPubMed
15.
go back to reference Kamata M, Kako H, Ramesh AS, Krishna SG, Tobias JD. An in vitro and in vivo validation of a novel color-coded syringe device for measuring the intracuff pressure in cuffed endotracheal tubes. Int J Clin Exp Med. 2015;8(7):11356–9.PubMedPubMedCentral Kamata M, Kako H, Ramesh AS, Krishna SG, Tobias JD. An in vitro and in vivo validation of a novel color-coded syringe device for measuring the intracuff pressure in cuffed endotracheal tubes. Int J Clin Exp Med. 2015;8(7):11356–9.PubMedPubMedCentral
16.
go back to reference Ramesh AS, Krishna SG, Denman WT, Tobias JD. An in vitro and in vivo validation of a novel monitor for intracuff pressure in cuffed endotracheal tubes. Paediatr Anaesth. 2014;24:1005–8.CrossRefPubMed Ramesh AS, Krishna SG, Denman WT, Tobias JD. An in vitro and in vivo validation of a novel monitor for intracuff pressure in cuffed endotracheal tubes. Paediatr Anaesth. 2014;24:1005–8.CrossRefPubMed
Metadata
Title
Assessing the correct inflation of the endotracheal tube cuff: a larger pilot balloon increases the sensitivity of the ‘finger-pressure’ technique, but it remains poorly reliable in clinical practice
Authors
Antonio Pisano
Luigi Verniero
Nicola Galdieri
Antonio Corcione
Publication date
01-04-2019
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2019
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-0158-8

Other articles of this Issue 2/2019

Journal of Clinical Monitoring and Computing 2/2019 Go to the issue