Skip to main content
Top
Published in: Insights into Imaging 1/2021

01-12-2021 | Computed Tomography | Original Article

The impact of lung parenchyma attenuation on nodule volumetry in lung cancer screening

Authors: Diana Penha, Erique Pinto, Bruno Hochhegger, Colin Monaghan, Edson Marchiori, Luís Taborda-Barata, Klaus Irion

Published in: Insights into Imaging | Issue 1/2021

Login to get access

Abstract

Background

Recent recommendations for lung nodule management include volumetric analysis using tools that present intrinsic measurement variability, with possible impacts on clinical decisions and patient safety. This study was conducted to evaluate whether changes in the attenuation of the lung parenchyma adjacent to a nodule affect the performance of nodule segmentation using computed tomography (CT) studies and volumetric tools.

Methods

Two radiologists retrospectively applied two commercially available volumetric tools for the assessment of lung nodules with diameters of 5–8 mm detected by low-dose chest CT during a lung cancer screening program. The radiologists recorded the success and adequacy of nodule segmentation, nodule volume, manually and automatically (or semi-automatically) obtained long- and short-axis measurements, mean attenuation of adjacent lung parenchyma, and presence of interstitial lung abnormalities or disease, emphysema, pleural plaques, and linear atelectasis. Regression analysis was performed to identify predictors of good nodule segmentation using the volumetric tools. Interobserver and intersoftware agreement on good nodule segmentation was assessed using the intraclass correlation coefficient.

Results

In total, data on 1265 nodules (mean patient age, 68.3 ± 5.1 years; 70.2% male) were included in the study. In the regression model, attenuation of the adjacent lung parenchyma was highly significant (odds ratio 0.987, p < 0.001), with a large effect size. Interobserver and intersoftware agreement on good segmentation was good, although one software package performed better and measurements differed consistently between software packages.

Conclusion

For lung nodules with diameters of 5–8 mm, the likelihood of good segmentation declines with increasing attenuation of the adjacent parenchyma.
Literature
2.
go back to reference Callister MEJ, Baldwin DR, Akram A et al (2015) British Thoracic Society Guidelines for the Investigation and Management of Pulmonary Nodules. Thorax 70(2):10 Callister MEJ, Baldwin DR, Akram A et al (2015) British Thoracic Society Guidelines for the Investigation and Management of Pulmonary Nodules. Thorax 70(2):10
14.
go back to reference de Hoop B, Gietema H, van Ginneken B, Zanen P, Groenewegen G, Prokop M (2009) A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations. Eur Radiol 19(4):800–808. https://doi.org/10.1007/s00330-008-1229-xCrossRefPubMed de Hoop B, Gietema H, van Ginneken B, Zanen P, Groenewegen G, Prokop M (2009) A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations. Eur Radiol 19(4):800–808. https://​doi.​org/​10.​1007/​s00330-008-1229-xCrossRefPubMed
Metadata
Title
The impact of lung parenchyma attenuation on nodule volumetry in lung cancer screening
Authors
Diana Penha
Erique Pinto
Bruno Hochhegger
Colin Monaghan
Edson Marchiori
Luís Taborda-Barata
Klaus Irion
Publication date
01-12-2021
Publisher
Springer International Publishing
Published in
Insights into Imaging / Issue 1/2021
Electronic ISSN: 1869-4101
DOI
https://doi.org/10.1186/s13244-021-01027-0

Other articles of this Issue 1/2021

Insights into Imaging 1/2021 Go to the issue