Skip to main content
Top
Published in: Critical Care 1/2020

Open Access 01-12-2020 | Coronavirus | Research

COVID-19: What Iodine Maps From Perfusion CT can reveal—A Prospective Cohort Study

Authors: Mario G. Santamarina, Dominique Boisier Riscal, Ignacio Beddings, Roberto Contreras, Martiniano Baque, Mariano Volpacchio, Felipe Martinez Lomakin

Published in: Critical Care | Issue 1/2020

Login to get access

Abstract

Background

Subtraction CT angiography (sCTA) is a technique used to evaluate pulmonary perfusion based on iodine distribution maps. The aim of this study is to assess lung perfusion changes with sCTA seen in patients with COVID-19 pneumonia and correlate them with clinical outcomes.

Material and methods

A prospective cohort study was carried out with 45 RT-PCR-confirmed COVID-19 patients that required hospitalization at three different hospitals, between April and May 2020. In all cases, a basic clinical and demographic profile was obtained. Lung perfusion was assessed using sCTA. Evaluated imaging features included: Pattern predominance of injured lung parenchyma in both lungs (ground-glass opacities, consolidation and mixed pattern) and anatomical extension; predominant type of perfusion abnormality (increased perfusion or hypoperfusion), perfusion abnormality distribution (focal or diffuse), extension of perfusion abnormalities (mild, moderate and severe involvement); presence of vascular dilatation and vascular tortuosity. All participants were followed-up until hospital discharge searching for the development of any of the study endpoints. These endpoints included intensive-care unit (ICU) admission, initiation of invasive mechanical ventilation (IMV) and death.

Results

Forty-one patients (55.2 ± 16.5 years, 22 men) with RT-PCR-confirmed SARS-CoV-2 infection and an interpretable iodine map were included. Patients with perfusion anomalies on sCTA in morphologically normal lung parenchyma showed lower Pa/Fi values (294 ± 111.3 vs. 397 ± 37.7, p = 0.035), and higher D-dimer levels (1156 ± 1018 vs. 378 ± 60.2, p < 0.01). The main common patterns seen in lung CT scans were ground-glass opacities, mixed pattern with predominant ground-glass opacities and mixed pattern with predominant consolidation in 56.1%, 24.4% and 19.5% respectively. Perfusion abnormalities were common (36 patients, 87.8%), mainly hypoperfusion in areas of apparently healthy lung. Patients with severe hypoperfusion in areas of apparently healthy lung parenchyma had an increased probability of being admitted to ICU and to initiate IMV (HR of 11.9 (95% CI 1.55–91.9) and HR 7.8 (95% CI 1.05–61.1), respectively).

Conclusion

Perfusion abnormalities evidenced in iodine maps obtained by sCTA are associated with increased admission to ICU and initiation of IMV in COVID-19 patients.
Literature
19.
go back to reference Tamura M, Yamada Y, Kawakami T, Kataoka M, Iwabuchi Y, Sugiura H, Hashimoto M, Nakahara T, Okuda S, Nakatsuka S, Sano F. Diagnostic accuracy of lung subtraction iodine mapping CT for the evaluation of pulmonary perfusion in patients with chronic thromboembolic pulmonary hypertension: correlation with perfusion SPECT/CT. Int J Cardiol. 2017;243:538–43. https://doi.org/10.1016/j.ijcard.2017.05.006. CrossRefPubMed Tamura M, Yamada Y, Kawakami T, Kataoka M, Iwabuchi Y, Sugiura H, Hashimoto M, Nakahara T, Okuda S, Nakatsuka S, Sano F. Diagnostic accuracy of lung subtraction iodine mapping CT for the evaluation of pulmonary perfusion in patients with chronic thromboembolic pulmonary hypertension: correlation with perfusion SPECT/CT. Int J Cardiol. 2017;243:538–43. https://​doi.​org/​10.​1016/​j.​ijcard.​2017.​05.​006. CrossRefPubMed
Metadata
Title
COVID-19: What Iodine Maps From Perfusion CT can reveal—A Prospective Cohort Study
Authors
Mario G. Santamarina
Dominique Boisier Riscal
Ignacio Beddings
Roberto Contreras
Martiniano Baque
Mariano Volpacchio
Felipe Martinez Lomakin
Publication date
01-12-2020
Publisher
BioMed Central
Published in
Critical Care / Issue 1/2020
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-020-03333-3

Other articles of this Issue 1/2020

Critical Care 1/2020 Go to the issue