Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2019

Open Access 01-12-2019 | Pelvic Ring Fractures | Research article

Tape suture for stabilization of incomplete posterior pelvic ring fractures—biomechanical analysis of a new minimally invasive treatment for incomplete lateral compression pelvic ring fractures

Authors: Christopher Alexander Becker, Adrian Cavalcanti Kussmaul, Eduardo Manuel Suero, Markus Regauer, Matthias Woiczinski, Christian Braun, Wilhelm Flatz, Oliver Pieske, Christian Kammerlander, Wolfgang Boecker, Axel Greiner

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2019

Login to get access

Abstract

Background

Incomplete lateral compression fractures (including AO Type B2.1) are among the most common pelvic ring injuries. Although the treatment of choice remains controversial, sacroiliac (SI) screws are commonly used for the operative treatment of incomplete lateral compression fractures of the pelvic ring. However, the disadvantages of SI screws include the risk of nerve root or blood vessel injury. Recently, tape sutures have been found useful as stabilizing material for the treatment of injuries of the syndesmosis, the rotator cuff and knee ligaments. In this current study, we aimed to test the biomechanical feasibility of tape sutures to stabilize the pelvis in the setting of AO Type B2.1 injury.

Methods

Six human cadaveric pelvises underwent cyclic loading to compare the biomechanical stability of different osteosynthesis methods in a B2.1 fracture model. The methods tested in this experiment were a FiberTape® suture and the currently established SI screw. A 3D ultrasound tracking system was used to measure fracture fragment motion. Linear regression was used to model displacement and stiffness at the posterior and anterior pelvic ring.

Results

At the posterior fracture site, the FiberTape® demonstrated similar displacement (2.2 ± 0.8 mm) and stiffness (52.2 ± 18.0 N/mm) compared to the sacroiliac screw (displacement 2.1 ± 0.6 mm, P >  0.999; stiffness 50.8 ± 13.0 N/mm, P > 0.999).
Considering the anterior fracture site, the FiberTape® again demonstrated similar displacement (3.8 ± 1.3 mm) and stiffness (29.5 ± 9.0 N/mm) compared to the sacroiliac screw (displacement 2.9 ± 0.8 mm, P = 0.2196; stiffness 37.5 ± 11.5 N/mm, P = 0.0711).

Conclusion

The newly presented osteosynthesis, the FiberTape®, shows promising results for the stabilization of the posterior pelvic ring in AO Type B2.1 lateral compression fractures compared to a sacroiliac screw osteosynthesis based on its minimal-invasiveness and the statistically similar biomechanical properties.
Literature
2.
go back to reference Li S, Meng X, Li W, Sun Z, Wang X, Qi H, Wei S, Zhou D. Effects of minimally invasive plate-screw internal fixation in the treatment of posterior pelvic ring fracture. Exp Ther Med. 2018;16(5):4150–4.PubMedPubMedCentral Li S, Meng X, Li W, Sun Z, Wang X, Qi H, Wei S, Zhou D. Effects of minimally invasive plate-screw internal fixation in the treatment of posterior pelvic ring fracture. Exp Ther Med. 2018;16(5):4150–4.PubMedPubMedCentral
3.
go back to reference Salari P, Cannada LK, Moed BR. Do asymptomatic patients have normal function after percutaneous fixation of the posterior pelvic ring? A case-control pilot study. J Orthop Surg Res. 2015;10(1):68.CrossRef Salari P, Cannada LK, Moed BR. Do asymptomatic patients have normal function after percutaneous fixation of the posterior pelvic ring? A case-control pilot study. J Orthop Surg Res. 2015;10(1):68.CrossRef
4.
go back to reference Lee S-W, Kim W-Y, Koh S-J, Kim Y-Y. Posterior locked lateral compression injury of the pelvis in geriatric patients: an infrequent and specific variant of the fragility fracture of pelvis. Arch Orthop Trauma Surg. 2017;137(9):1207–18.CrossRef Lee S-W, Kim W-Y, Koh S-J, Kim Y-Y. Posterior locked lateral compression injury of the pelvis in geriatric patients: an infrequent and specific variant of the fragility fracture of pelvis. Arch Orthop Trauma Surg. 2017;137(9):1207–18.CrossRef
5.
go back to reference Höch A, Özkurtul O, Pieroh P, Josten C, Böhme J. Outcome and 2-year survival rate in elderly patients with lateral compression fractures of the pelvis. Geriatr Orthop Surg Rehabil. 2017;8(1):3–9.CrossRef Höch A, Özkurtul O, Pieroh P, Josten C, Böhme J. Outcome and 2-year survival rate in elderly patients with lateral compression fractures of the pelvis. Geriatr Orthop Surg Rehabil. 2017;8(1):3–9.CrossRef
6.
go back to reference Beckmann JT, Presson AP, Curtis SH, Haller JM, Stuart AR, Higgins TF, Kubiak EN. Operative agreement on lateral compression-1 pelvis fractures. A survey of 111 OTA members. J Orthop Trauma. 2014;28(12):681–5.CrossRef Beckmann JT, Presson AP, Curtis SH, Haller JM, Stuart AR, Higgins TF, Kubiak EN. Operative agreement on lateral compression-1 pelvis fractures. A survey of 111 OTA members. J Orthop Trauma. 2014;28(12):681–5.CrossRef
7.
go back to reference Yinger K, Scalise J, Olson SA, Bay BK, Finkemeier CG. Biomechanical comparison of posterior pelvic ring fixation. J Orthop Trauma. 2003;17(7):481–7.CrossRef Yinger K, Scalise J, Olson SA, Bay BK, Finkemeier CG. Biomechanical comparison of posterior pelvic ring fixation. J Orthop Trauma. 2003;17(7):481–7.CrossRef
8.
go back to reference Giráldez-Sánchez MA, Lázaro-Gonzálvez Á, Martínez-Reina J, Serrano-Toledano D, Navarro-Robles A, Cano-Luis P, Fragkakis EM, Giannoudis PV. Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis. Injury. 2015;46(2):327–32.CrossRef Giráldez-Sánchez MA, Lázaro-Gonzálvez Á, Martínez-Reina J, Serrano-Toledano D, Navarro-Robles A, Cano-Luis P, Fragkakis EM, Giannoudis PV. Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis. Injury. 2015;46(2):327–32.CrossRef
9.
go back to reference Iorio JA, Jakoi AM, Rehman S. Percutaneous sacroiliac screw fixation of the posterior pelvic ring. Orthop Clin North Am. 2015;46(4):511–21.CrossRef Iorio JA, Jakoi AM, Rehman S. Percutaneous sacroiliac screw fixation of the posterior pelvic ring. Orthop Clin North Am. 2015;46(4):511–21.CrossRef
10.
go back to reference Pieske O, Landersdorfer C, Trumm C, Greiner A, Wallmichrath J, Gottschalk O, Rubenbauer B. CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: accuracy of screw position, injury reduction and complications in 71 patients with 136 screws. Injury. 2015;46(2):333–9.CrossRef Pieske O, Landersdorfer C, Trumm C, Greiner A, Wallmichrath J, Gottschalk O, Rubenbauer B. CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: accuracy of screw position, injury reduction and complications in 71 patients with 136 screws. Injury. 2015;46(2):333–9.CrossRef
11.
go back to reference van den Bosch EW, van Zwienen CMA, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma. 2002;53(1):44–8.CrossRef van den Bosch EW, van Zwienen CMA, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma. 2002;53(1):44–8.CrossRef
12.
go back to reference Kerschbaum M, Hausmann N, Worlicek M, Pfeifer C, Nerlich M, Schmitz P. Patient-related outcome of unstable pelvic ring fractures stabilized with a minimal invasive screw-rod system. Health Qual Life Outcomes. 2017;15(1):248.CrossRef Kerschbaum M, Hausmann N, Worlicek M, Pfeifer C, Nerlich M, Schmitz P. Patient-related outcome of unstable pelvic ring fractures stabilized with a minimal invasive screw-rod system. Health Qual Life Outcomes. 2017;15(1):248.CrossRef
13.
go back to reference Vigdorchik JM, Jin X, Sethi A, Herzog DT, Oliphant BW, Yang KH, Vaidya R. A biomechanical study of standard posterior pelvic ring fixation versus a posterior pedicle screw construct. Injury. 2015;46(8):1491–6.CrossRef Vigdorchik JM, Jin X, Sethi A, Herzog DT, Oliphant BW, Yang KH, Vaidya R. A biomechanical study of standard posterior pelvic ring fixation versus a posterior pedicle screw construct. Injury. 2015;46(8):1491–6.CrossRef
14.
go back to reference Regauer M, Mackay G, Lange M, Kammerlander C, Böcker W. Syndesmotic Internal Brace TM for anatomic distal tibiofibular ligament augmentation. World J Orthop. 2017;8(4):301.CrossRef Regauer M, Mackay G, Lange M, Kammerlander C, Böcker W. Syndesmotic Internal Brace TM for anatomic distal tibiofibular ligament augmentation. World J Orthop. 2017;8(4):301.CrossRef
15.
go back to reference Gilmer BB, Crall T, DeLong J, Kubo T, Mackay G, Jani SS. Biomechanical analysis of internal bracing for treatment of medial knee injuries. Orthopedics. 2016;39(3):e532–7.CrossRef Gilmer BB, Crall T, DeLong J, Kubo T, Mackay G, Jani SS. Biomechanical analysis of internal bracing for treatment of medial knee injuries. Orthopedics. 2016;39(3):e532–7.CrossRef
16.
go back to reference Ono Y, Joly DA, Thornton GM, Lo IKY. Mechanical and imaging evaluation of the effect of sutures on tendons: tape sutures are protective to suture pulling through tendon. J Shoulder Elbow Surg. 2018;27(9):1705–10.CrossRef Ono Y, Joly DA, Thornton GM, Lo IKY. Mechanical and imaging evaluation of the effect of sutures on tendons: tape sutures are protective to suture pulling through tendon. J Shoulder Elbow Surg. 2018;27(9):1705–10.CrossRef
17.
go back to reference Nothofer W, Thonke N, Neugebauer R. Die Therapie instabiler Sakrumfrakturen bei Beckenringbruechen mit dorsaler Sakrumdistanzosteosynthese. Der Unfallchirurg. 2004;107(2):118–28.CrossRef Nothofer W, Thonke N, Neugebauer R. Die Therapie instabiler Sakrumfrakturen bei Beckenringbruechen mit dorsaler Sakrumdistanzosteosynthese. Der Unfallchirurg. 2004;107(2):118–28.CrossRef
18.
go back to reference Soin SP, Knight TA, Dinah AF, Mears SC, Swierstra BA, Belkoff SM. Suture-button versus screw fixation in a syndesmosis rupture model: a biomechanical comparison. Foot Ankle Int. 2009;30(4):346–52.CrossRef Soin SP, Knight TA, Dinah AF, Mears SC, Swierstra BA, Belkoff SM. Suture-button versus screw fixation in a syndesmosis rupture model: a biomechanical comparison. Foot Ankle Int. 2009;30(4):346–52.CrossRef
20.
go back to reference van den Bosch EW, van Zwienen CMA, Hoek van Dijke GA, Snijders CJ, van Vugt AB. Sacroiliac screw fixation for tile B fractures. J Trauma. 2003;55(5):962–5.CrossRef van den Bosch EW, van Zwienen CMA, Hoek van Dijke GA, Snijders CJ, van Vugt AB. Sacroiliac screw fixation for tile B fractures. J Trauma. 2003;55(5):962–5.CrossRef
21.
go back to reference Krappinger D, Larndorfer R, Struve P, Rosenberger R, Arora R, Blauth M. Minimally invasive transiliac plate osteosynthesis for type C injuries of the pelvic ring: a clinical and radiological follow-up. J Orthop Trauma. 2007;21(9):595–602.CrossRef Krappinger D, Larndorfer R, Struve P, Rosenberger R, Arora R, Blauth M. Minimally invasive transiliac plate osteosynthesis for type C injuries of the pelvic ring: a clinical and radiological follow-up. J Orthop Trauma. 2007;21(9):595–602.CrossRef
22.
go back to reference Kobbe P, Hockertz I, Sellei RM, Reilmann H, Hockertz T. Minimally invasive stabilisation of posterior pelvic-ring instabilities with a transiliac locked compression plate. Int Orthop. 2012;36(1):159–64.CrossRef Kobbe P, Hockertz I, Sellei RM, Reilmann H, Hockertz T. Minimally invasive stabilisation of posterior pelvic-ring instabilities with a transiliac locked compression plate. Int Orthop. 2012;36(1):159–64.CrossRef
23.
go back to reference Wang H, Fu Y-H, Ke C, Zhuang Y, Zhang K, Wei X, Li Z, Lei J-L, Zhang B-F, Liu P. Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod. Int Orthop. 2018;42(3):681–6.CrossRef Wang H, Fu Y-H, Ke C, Zhuang Y, Zhang K, Wei X, Li Z, Lei J-L, Zhang B-F, Liu P. Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod. Int Orthop. 2018;42(3):681–6.CrossRef
24.
go back to reference Quinn RH, Sanders JO, Brown GA, Murray J, Pezold R. The American Academy of Orthopaedic Surgeons Appropriate Use Criteria on the management of anterior cruciate ligament injuries. J Bone Joint Surg Am. 2016;98(2):153–5.CrossRef Quinn RH, Sanders JO, Brown GA, Murray J, Pezold R. The American Academy of Orthopaedic Surgeons Appropriate Use Criteria on the management of anterior cruciate ligament injuries. J Bone Joint Surg Am. 2016;98(2):153–5.CrossRef
25.
go back to reference Routt ML, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma. 1997;11(8):584–9.CrossRef Routt ML, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma. 1997;11(8):584–9.CrossRef
26.
go back to reference Osterhoff G, Ossendorf C, Wanner GA, Simmen H-P, Werner CML. Posterior screw fixation in rotationally unstable pelvic ring injuries. Injury. 2011;42(10):992–6.CrossRef Osterhoff G, Ossendorf C, Wanner GA, Simmen H-P, Werner CML. Posterior screw fixation in rotationally unstable pelvic ring injuries. Injury. 2011;42(10):992–6.CrossRef
27.
go back to reference Chalidis B, Stengel D, Giannoudis PV. Early excision and late excision of heterotopic ossification after traumatic brain injury are equivalent: a systematic review of the literature. J Neurotrauma. 2007;24(11):1675–86.CrossRef Chalidis B, Stengel D, Giannoudis PV. Early excision and late excision of heterotopic ossification after traumatic brain injury are equivalent: a systematic review of the literature. J Neurotrauma. 2007;24(11):1675–86.CrossRef
28.
go back to reference Templeman D, Schmidt A, Freese J, Weisman I. Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res. 1996 August;329:194–8.CrossRef Templeman D, Schmidt A, Freese J, Weisman I. Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop Relat Res. 1996 August;329:194–8.CrossRef
29.
go back to reference Behrendt D, Mütze M, Steinke H, Koestler M, Josten C, Böhme J. Evaluation of 2D and 3D navigation for iliosacral screw fixation. Int J Comput Assist Radiol Surg. 2012;7(2):249–55.CrossRef Behrendt D, Mütze M, Steinke H, Koestler M, Josten C, Böhme J. Evaluation of 2D and 3D navigation for iliosacral screw fixation. Int J Comput Assist Radiol Surg. 2012;7(2):249–55.CrossRef
30.
go back to reference Arand M, Kinzl L, Gebhard F. Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop Relat Res. 2004;422:201–7.CrossRef Arand M, Kinzl L, Gebhard F. Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop Relat Res. 2004;422:201–7.CrossRef
31.
go back to reference Höch A, Schneider I, Todd J, Josten C, Böhme J. Lateral compression type B 2-1 pelvic ring fractures in young patients do not require surgery. Eur J Trauma Emerg Surg. 2018;44(2):171–7.CrossRef Höch A, Schneider I, Todd J, Josten C, Böhme J. Lateral compression type B 2-1 pelvic ring fractures in young patients do not require surgery. Eur J Trauma Emerg Surg. 2018;44(2):171–7.CrossRef
32.
go back to reference Sanders D, Fox J, Starr A, Sathy A, Chao J. Transsacral-transiliac screw stabilization: effective for recalcitrant pain due to sacral insufficiency fracture. J Orthop Trauma. 2016;30(9):469–73.CrossRef Sanders D, Fox J, Starr A, Sathy A, Chao J. Transsacral-transiliac screw stabilization: effective for recalcitrant pain due to sacral insufficiency fracture. J Orthop Trauma. 2016;30(9):469–73.CrossRef
Metadata
Title
Tape suture for stabilization of incomplete posterior pelvic ring fractures—biomechanical analysis of a new minimally invasive treatment for incomplete lateral compression pelvic ring fractures
Authors
Christopher Alexander Becker
Adrian Cavalcanti Kussmaul
Eduardo Manuel Suero
Markus Regauer
Matthias Woiczinski
Christian Braun
Wilhelm Flatz
Oliver Pieske
Christian Kammerlander
Wolfgang Boecker
Axel Greiner
Publication date
01-12-2019
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2019
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-019-1509-y

Other articles of this Issue 1/2019

Journal of Orthopaedic Surgery and Research 1/2019 Go to the issue