Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2018

Open Access 01-12-2018 | Technical note

A novel implant removal technique by endoscopy

Authors: Chang Heng Liu, Wen Lin Yeh, Ping Jui Tsai, Kuo Feng Fan, Hung Wei Cheng, Jian Ming Chen

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2018

Login to get access

Abstract

Background

Routine implant removal after fracture healing remains controversial. However, it has been suggested that implant removal should be performed in cases of joint impingement, painful scar adhesion, and implant malposition. Entrance selection is relatively critical in patients with poor soft tissue conditions or sloughing coverage. We propose an innovative technique using endoscopy.

Methods

Consecutive surgeries of endoscopic implant removal performed between 2005 and 2016 by a single experienced arthroscopic surgeon were included. Overall, 73 patients were enrolled; 44 were not eligible for inclusion and were excluded from the study.

Results

Twenty-nine patients, including 32 surgical sites, were included. Twenty-four plates and 166 screws were removed using this technique. There were five complications during the follow-up period (range, 0.5 to 104 months; mean, 8.8), including one broken screw, one persistent knee joint contracture, and three wound dehiscence. There were no infections or neurovascular injuries.

Conclusion

Implant removal using endoscopy is a minimally invasive surgery that ensures that the screw axis does not strip, and treats the intra-articular pathology concomitantly. This innovative technique may be considered as an alternative to the traditional open method in cases with good surgical indications.
Literature
1.
go back to reference Kirchhoff C, Braunstein V, Kirchhoff S, Sprecher CM, Ockert B, Fischer F, et al. Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC Musculoskelet Disord. 2008;9:138.CrossRefPubMedPubMedCentral Kirchhoff C, Braunstein V, Kirchhoff S, Sprecher CM, Ockert B, Fischer F, et al. Outcome analysis following removal of locking plate fixation of the proximal humerus. BMC Musculoskelet Disord. 2008;9:138.CrossRefPubMedPubMedCentral
2.
go back to reference Lutsky KF, Beredjiklian PK, Hioe S, Bilello J, Kim N, Matzon JL. Incidence of hardware removal following volar plate fixation of distal radius fracture. J Hand Surg. 2015;40(12):2410–5.CrossRef Lutsky KF, Beredjiklian PK, Hioe S, Bilello J, Kim N, Matzon JL. Incidence of hardware removal following volar plate fixation of distal radius fracture. J Hand Surg. 2015;40(12):2410–5.CrossRef
4.
go back to reference Tan A, Chong A. Reasons for implant removal after distal radius fractures. J Hand Surg Asian Pac Vol. 2016;21(3):321–5.CrossRefPubMed Tan A, Chong A. Reasons for implant removal after distal radius fractures. J Hand Surg Asian Pac Vol. 2016;21(3):321–5.CrossRefPubMed
5.
go back to reference Lovald S, Mercer D, Hanson J, Cowgill I, Erdman M, Robinson P, et al. Complications and hardware removal after open reduction and internal fixation of humeral fractures. J Trauma. 2011;70(5):1273–7. discussion 7-8CrossRefPubMed Lovald S, Mercer D, Hanson J, Cowgill I, Erdman M, Robinson P, et al. Complications and hardware removal after open reduction and internal fixation of humeral fractures. J Trauma. 2011;70(5):1273–7. discussion 7-8CrossRefPubMed
6.
go back to reference Busam ML, Esther RJ, Obremskey WT. Hardware removal: indications and expectations. J Am Acad Orthop Surg. 2006;14(2):113–20.CrossRefPubMed Busam ML, Esther RJ, Obremskey WT. Hardware removal: indications and expectations. J Am Acad Orthop Surg. 2006;14(2):113–20.CrossRefPubMed
7.
go back to reference Ochs BG, Gonser CE, Baron HC, Stockle U, Badke A, Stuby FM. Refracture of long bones after implant removal. An avoidable complication? Unfallchirurg. 2012;115(4):323–9.CrossRefPubMed Ochs BG, Gonser CE, Baron HC, Stockle U, Badke A, Stuby FM. Refracture of long bones after implant removal. An avoidable complication? Unfallchirurg. 2012;115(4):323–9.CrossRefPubMed
8.
9.
go back to reference Backes M, Schep NW, Luitse JS, Goslings JC, Schepers T. High rates of postoperative wound infection following elective implant removal. Open Orthop J. 2015;9:418–21.CrossRefPubMedPubMedCentral Backes M, Schep NW, Luitse JS, Goslings JC, Schepers T. High rates of postoperative wound infection following elective implant removal. Open Orthop J. 2015;9:418–21.CrossRefPubMedPubMedCentral
10.
go back to reference Reith G, Schmitz-Greven V, Hensel KO, Schneider MM, Tinschmann T, Bouillon B, et al. Metal implant removal: benefits and drawbacks—a patient survey. BMC Surg. 2015;15:96.CrossRefPubMedPubMedCentral Reith G, Schmitz-Greven V, Hensel KO, Schneider MM, Tinschmann T, Bouillon B, et al. Metal implant removal: benefits and drawbacks—a patient survey. BMC Surg. 2015;15:96.CrossRefPubMedPubMedCentral
11.
12.
go back to reference Lill H, Katthagen C, Voigt C. Technique and value of arthroscopic implant removal in the shoulder. Orthopade. 2011;40(1):79–84.CrossRefPubMed Lill H, Katthagen C, Voigt C. Technique and value of arthroscopic implant removal in the shoulder. Orthopade. 2011;40(1):79–84.CrossRefPubMed
13.
go back to reference Katthagen JC, Jensen G, Hennecke D, Lill H, Voigt C. Arthroscopic implant removal after fixed-angle plate osteosynthesis of the proximal humerus. Technique and initial results in comparison to open implant removal. Unfallchirurg. 2012;115(1):47–54.CrossRefPubMed Katthagen JC, Jensen G, Hennecke D, Lill H, Voigt C. Arthroscopic implant removal after fixed-angle plate osteosynthesis of the proximal humerus. Technique and initial results in comparison to open implant removal. Unfallchirurg. 2012;115(1):47–54.CrossRefPubMed
14.
go back to reference Voigt C, Geisler A, Lill H. Arthroscopic locking plate removal after proximal humeral fractures. Arch Orthop Trauma Surg. 2010;130(3):391–5.CrossRefPubMed Voigt C, Geisler A, Lill H. Arthroscopic locking plate removal after proximal humeral fractures. Arch Orthop Trauma Surg. 2010;130(3):391–5.CrossRefPubMed
15.
go back to reference Dines JS, Hettrich CM, Kelly BT, Savoie FH 3rd, Lorich DG. Arthroscopic removal of proximal humerus locking plates. Knee Surg Sports Traumatol Arthrosc. 2010;18(3):409–11.CrossRefPubMed Dines JS, Hettrich CM, Kelly BT, Savoie FH 3rd, Lorich DG. Arthroscopic removal of proximal humerus locking plates. Knee Surg Sports Traumatol Arthrosc. 2010;18(3):409–11.CrossRefPubMed
16.
go back to reference Maroun C, Aliani D, Hass A, Werthel JD, Vidil A, Valenti P. Shoulder arthroscopy combined to hardware removal in proximal humeral fractures: a series of 58 cases with a mean follow-up of 2 years. Eur J Orthop Surg Traumatol. 2017;27(3):317–21.CrossRefPubMed Maroun C, Aliani D, Hass A, Werthel JD, Vidil A, Valenti P. Shoulder arthroscopy combined to hardware removal in proximal humeral fractures: a series of 58 cases with a mean follow-up of 2 years. Eur J Orthop Surg Traumatol. 2017;27(3):317–21.CrossRefPubMed
17.
go back to reference Berrios-Torres SI, Umscheid CA, Bratzler DW, Leas B, Stone EC, Kelz RR, et al. Centers for disease control and prevention guideline for the prevention of surgical site infection, 2017. JAMA Surg. 2017;152(8):784–91.CrossRefPubMed Berrios-Torres SI, Umscheid CA, Bratzler DW, Leas B, Stone EC, Kelz RR, et al. Centers for disease control and prevention guideline for the prevention of surgical site infection, 2017. JAMA Surg. 2017;152(8):784–91.CrossRefPubMed
18.
go back to reference Backes M, Dingemans SA, Dijkgraaf MGW, van den Berg HR, van Dijkman B, Hoogendoorn JM, et al. Effect of antibiotic prophylaxis on surgical site infections following removal of orthopedic implants used for treatment of foot, ankle, and lower leg fractures: a randomized clinical trial. JAMA. 2017;318(24):2438–45.CrossRefPubMed Backes M, Dingemans SA, Dijkgraaf MGW, van den Berg HR, van Dijkman B, Hoogendoorn JM, et al. Effect of antibiotic prophylaxis on surgical site infections following removal of orthopedic implants used for treatment of foot, ankle, and lower leg fractures: a randomized clinical trial. JAMA. 2017;318(24):2438–45.CrossRefPubMed
19.
go back to reference Maqdes A, Levy B, Klouche S, Hardy P. The feasibility and results of an arthroscopic removal of humeral locking plates and glenohumeral arthrolysis after proximal humeral fractures. Knee Surg Sports Traumatol Arthrosc. 2014;22(2):456–61.CrossRefPubMed Maqdes A, Levy B, Klouche S, Hardy P. The feasibility and results of an arthroscopic removal of humeral locking plates and glenohumeral arthrolysis after proximal humeral fractures. Knee Surg Sports Traumatol Arthrosc. 2014;22(2):456–61.CrossRefPubMed
20.
go back to reference Kim KC, Rhee KJ, Shin HD, Kim YM. Arthroscopic removal of an intramedullary nail in the humerus. Knee Surg Sports Traumatol Arthrosc. 2007;15(7):922–6.CrossRefPubMed Kim KC, Rhee KJ, Shin HD, Kim YM. Arthroscopic removal of an intramedullary nail in the humerus. Knee Surg Sports Traumatol Arthrosc. 2007;15(7):922–6.CrossRefPubMed
21.
go back to reference Katthagen JC, Hennecke D, Jensen G, Ellwein A, Voigt C, Lill H. Arthroscopy after locked plating of proximal humeral fractures: implant removal, capsular release, and intra-articular findings. Arthroscopy. 2014;30(9):1061–7.CrossRefPubMed Katthagen JC, Hennecke D, Jensen G, Ellwein A, Voigt C, Lill H. Arthroscopy after locked plating of proximal humeral fractures: implant removal, capsular release, and intra-articular findings. Arthroscopy. 2014;30(9):1061–7.CrossRefPubMed
22.
go back to reference Gardner MJ, Griffith MH, Dines JS, Briggs SM, Weiland AJ, Lorich DG. The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus. Clin Orthop Relat Res. 2005;434:123–9.CrossRef Gardner MJ, Griffith MH, Dines JS, Briggs SM, Weiland AJ, Lorich DG. The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus. Clin Orthop Relat Res. 2005;434:123–9.CrossRef
23.
go back to reference Voleti PB, Camp CL, Sinatro AL, Dines JS. Arthroscopic removal of symptomatic proximal humerus locking plates with bone-void filler augmentation. Arthrosc Tech. 2016;5(2):e343–6.CrossRefPubMedPubMedCentral Voleti PB, Camp CL, Sinatro AL, Dines JS. Arthroscopic removal of symptomatic proximal humerus locking plates with bone-void filler augmentation. Arthrosc Tech. 2016;5(2):e343–6.CrossRefPubMedPubMedCentral
Metadata
Title
A novel implant removal technique by endoscopy
Authors
Chang Heng Liu
Wen Lin Yeh
Ping Jui Tsai
Kuo Feng Fan
Hung Wei Cheng
Jian Ming Chen
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2018
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-018-0783-4

Other articles of this Issue 1/2018

Journal of Orthopaedic Surgery and Research 1/2018 Go to the issue