Skip to main content
Top
Published in: International Urology and Nephrology 5/2024

13-12-2023 | Arteriovenous Fistula | Nephrology - Original Paper

Evaluation of arteriovenous fistula for hemodialysis with a new generation digital stethoscope: a pilot study

Authors: Pierangela Presta, Nazareno Carullo, Annarita Armeni, Maria Teresa Zicarelli, Michela Musolino, Maria Giovanna Bianco, Salvatore Chiarella, Michele Andreucci, Antonino S. Fiorillo, Salvatore Andrea Pullano, Davide Bolignano, Giuseppe Coppolino

Published in: International Urology and Nephrology | Issue 5/2024

Login to get access

Abstract

Background and aims

The management of complications of arteriovenous fistula (AVF) for hemodialysis, principally stenosis, remains a major challenge for clinicians with a substantial impact on health resources. Stenosis not infrequently preludes to thrombotic events with the loss of AVF functionality. A functioning AVF, when listened by a stethoscope, has a continuous systolic–diastolic low-frequency murmur, while with stenosis, the frequency of the murmur increases and the duration of diastolic component decreases, disappearing in severe stenosis. These evidences are strictly subjective and dependent from operator skill and experience. New generation digital stethoscopes are able to record sound and subsequently dedicated software allows to extract quantitative variables that characterize the sound in an absolutely objective and repeatable way. The aim of our study was to analyze with an appropriate software sounds from AVFs taken by a commercial digital stethoscope and to investigate the potentiality to develop an objective way to detect stenosis.

Methods

Between September 2022 and January 2023, 64 chronic hemodialysis (HD) patients were screened by two blinded experienced examiners for recognized criteria for stenosis by Doppler ultrasound (DUS) and, consequently, the sound coming from the AVFs using a 3 M™ Littmann® CORE Digital Stethoscope 8570 in standardized sites was recorded. The sound waves were transformed into quantitative variables (amplitude and frequency) using a sound analysis software. The practical usefulness of the core digital stethoscope for a quick identification of an AVF stenosis was further evaluated through a pragmatic trial. Eight young nephrologist trainees underwent a simple auscultatory training consisting of two sessions of sound auscultation focusing two times on a “normal” AVF sound by placing the digital stethoscope on a convenience site of a functional AVF.

Results

In 48 patients eligible, all sound components displayed, alone, a remarkable diagnostic capacity. More in detail, the AUC of the average power was 0.872 [95% CI 0.729–0.951], while that of the mean normalized frequency was 0.822 [95% 0.656–0.930]. From a total of 32 auscultations (eight different block sequences, each one comprising four auscultations), the young clinicians were able to identify the correct sound (stenosis/normal AVF) in 25 cases, corresponding to an overall accuracy of 78.12% (95% CI 60.03–90.72%).

Conclusions

The analysis of sound waves by a digital stethoscope permitted us to distinguish between stenotic and no stenotic AVFs. The standardization of this technique and the introducing of data in a deep learning algorithm could allow an objective and fast method for a frequent monitoring of AVF.
Literature
2.
go back to reference Roca-Tey R, Ibeas J, Moreno T, Gruss E, Merino JL, Vallespin J, Hernan D, Arribas P, Spanish Multidisciplinary Vascular Access G (2018) Dialysis arteriovenous access monitoring and surveillance according to the 2017 Spanish guidelines. J Vasc Access 19:422–429CrossRefPubMed Roca-Tey R, Ibeas J, Moreno T, Gruss E, Merino JL, Vallespin J, Hernan D, Arribas P, Spanish Multidisciplinary Vascular Access G (2018) Dialysis arteriovenous access monitoring and surveillance according to the 2017 Spanish guidelines. J Vasc Access 19:422–429CrossRefPubMed
3.
go back to reference Schwarz C, Mitterbauer C, Boczula M, Maca T, Funovics M, Heinze G, Lorenz M, Kovarik J, Oberbauer R (2003) Flow monitoring: performance characteristics of ultrasound dilution versus color Doppler ultrasound compared with fistulography. Am J Kidney Dis 42:539–545CrossRefPubMed Schwarz C, Mitterbauer C, Boczula M, Maca T, Funovics M, Heinze G, Lorenz M, Kovarik J, Oberbauer R (2003) Flow monitoring: performance characteristics of ultrasound dilution versus color Doppler ultrasound compared with fistulography. Am J Kidney Dis 42:539–545CrossRefPubMed
4.
go back to reference Malik J, Lomonte C, Meola M, de Bont C, Shahverdyan R, Rotmans JI, Saucy F, Jemcov T, Ibeas J (2021) The role of Doppler ultrasonography in vascular access surveillance-controversies continue. J Vasc Access 22:63–70CrossRefPubMedPubMedCentral Malik J, Lomonte C, Meola M, de Bont C, Shahverdyan R, Rotmans JI, Saucy F, Jemcov T, Ibeas J (2021) The role of Doppler ultrasonography in vascular access surveillance-controversies continue. J Vasc Access 22:63–70CrossRefPubMedPubMedCentral
5.
go back to reference Colombo A, Provenzano M, Rivoli L, Donato C, Capria M, Leonardi G, Chiarella S, Andreucci M, Fuiano G, Bolignano D, Coppolino G (2020) Utility of blood flow/resistance index ratio (Q(x)) as a marker of stenosis and future thrombotic events in native arteriovenous fistulas. Front Surg 7:604347CrossRefPubMed Colombo A, Provenzano M, Rivoli L, Donato C, Capria M, Leonardi G, Chiarella S, Andreucci M, Fuiano G, Bolignano D, Coppolino G (2020) Utility of blood flow/resistance index ratio (Q(x)) as a marker of stenosis and future thrombotic events in native arteriovenous fistulas. Front Surg 7:604347CrossRefPubMed
6.
go back to reference Lok CE, Huber TS, Lee T, Shenoy S, Yevzlin AS, Abreo K, Allon M, Asif A, Astor BC, Glickman MH, Graham J, Moist LM, Rajan DK, Roberts C, Vachharajani TJ, Valentini RP, National KF (2020) KDOQI clinical practice guideline for vascular access: 2019 update. Am J Kidney Dis 75:S1–S164CrossRefPubMed Lok CE, Huber TS, Lee T, Shenoy S, Yevzlin AS, Abreo K, Allon M, Asif A, Astor BC, Glickman MH, Graham J, Moist LM, Rajan DK, Roberts C, Vachharajani TJ, Valentini RP, National KF (2020) KDOQI clinical practice guideline for vascular access: 2019 update. Am J Kidney Dis 75:S1–S164CrossRefPubMed
8.
go back to reference Provenzano M, Jongs N, Vart P, Stefansson BV, Chertow GM, Langkilde AM, McMurray JJV, Correa-Rotter R, Rossing P, Sjostrom CD, Toto RD, Wheeler DC, Heerspink HJL, Committees D-CT and Investigators (2022) The kidney protective effects of the sodium-glucose cotransporter-2 inhibitor, dapagliflozin, are present in patients with CKD treated with mineralocorticoid receptor antagonists. Kidney Int Rep. https://doi.org/10.1016/j.ekir.2021.12.013CrossRefPubMedPubMedCentral Provenzano M, Jongs N, Vart P, Stefansson BV, Chertow GM, Langkilde AM, McMurray JJV, Correa-Rotter R, Rossing P, Sjostrom CD, Toto RD, Wheeler DC, Heerspink HJL, Committees D-CT and Investigators (2022) The kidney protective effects of the sodium-glucose cotransporter-2 inhibitor, dapagliflozin, are present in patients with CKD treated with mineralocorticoid receptor antagonists. Kidney Int Rep. https://​doi.​org/​10.​1016/​j.​ekir.​2021.​12.​013CrossRefPubMedPubMedCentral
10.
go back to reference Malik J, Kudlicka J, Novakova L, Adamec J, Malikova H, Kavan J (2014) Surveillance of arteriovenous accesses with the use of duplex Doppler ultrasonography. J Vasc Access 15(Suppl 7):S28-32CrossRefPubMed Malik J, Kudlicka J, Novakova L, Adamec J, Malikova H, Kavan J (2014) Surveillance of arteriovenous accesses with the use of duplex Doppler ultrasonography. J Vasc Access 15(Suppl 7):S28-32CrossRefPubMed
11.
go back to reference Mansy HA, Hoxie SJ, Patel NH, Sandler RH (2005) Computerised analysis of auscultatory sounds associated with vascular patency of haemodialysis access. Med Biol Eng Comput 43:56–62CrossRefPubMed Mansy HA, Hoxie SJ, Patel NH, Sandler RH (2005) Computerised analysis of auscultatory sounds associated with vascular patency of haemodialysis access. Med Biol Eng Comput 43:56–62CrossRefPubMed
12.
go back to reference Sato T, Tsuji K, Kawashima N, Agishi T, Toma H (2006) Evaluation of blood access dysfunction based on a wavelet transform analysis of shunt murmurs. J Artif Organs 9:97–104CrossRefPubMed Sato T, Tsuji K, Kawashima N, Agishi T, Toma H (2006) Evaluation of blood access dysfunction based on a wavelet transform analysis of shunt murmurs. J Artif Organs 9:97–104CrossRefPubMed
13.
go back to reference Malindretos P, Liaskos C, Bamidis P, Chryssogonidis I, Lasaridis A, Nikolaidis P (2014) Computer assisted sound analysis of arteriovenous fistula in hemodialysis patients. Int J Artif Organs 37:173–176CrossRefPubMed Malindretos P, Liaskos C, Bamidis P, Chryssogonidis I, Lasaridis A, Nikolaidis P (2014) Computer assisted sound analysis of arteriovenous fistula in hemodialysis patients. Int J Artif Organs 37:173–176CrossRefPubMed
14.
go back to reference Sturiale A, Coppolino G, Loddo S, Criseo M, Campo S, Crasci E, Bolignano D, Nostro L, Teti D, Buemi M (2007) Effects of haemodialysis on circulating endothelial progenitor cell count. Blood Purif 25:242–251CrossRefPubMed Sturiale A, Coppolino G, Loddo S, Criseo M, Campo S, Crasci E, Bolignano D, Nostro L, Teti D, Buemi M (2007) Effects of haemodialysis on circulating endothelial progenitor cell count. Blood Purif 25:242–251CrossRefPubMed
15.
go back to reference Abreo K, Amin BM, Abreo AP (2019) Physical examination of the hemodialysis arteriovenous fistula to detect early dysfunction. J Vasc Access 20:7–11CrossRefPubMed Abreo K, Amin BM, Abreo AP (2019) Physical examination of the hemodialysis arteriovenous fistula to detect early dysfunction. J Vasc Access 20:7–11CrossRefPubMed
16.
go back to reference Coentrao L, Faria B, Pestana M (2012) Physical examination of dysfunctional arteriovenous fistulae by non-interventionalists: a skill worth teaching. Nephrol Dial Transplant 27:1993–1996CrossRefPubMed Coentrao L, Faria B, Pestana M (2012) Physical examination of dysfunctional arteriovenous fistulae by non-interventionalists: a skill worth teaching. Nephrol Dial Transplant 27:1993–1996CrossRefPubMed
17.
go back to reference Swarup S, Makaryus AN (2018) Digital stethoscope: technology update. Med Devices (Auckl) 11:29–36PubMed Swarup S, Makaryus AN (2018) Digital stethoscope: technology update. Med Devices (Auckl) 11:29–36PubMed
18.
go back to reference Isaak A, Jorg L, Attigah N, Thalhammer C, Staub D, Aschwanden M, Richarz S (2023) Practical guide of vascular ultrasound in arteriovenous fistulae. Vasa 52:22–28CrossRefPubMed Isaak A, Jorg L, Attigah N, Thalhammer C, Staub D, Aschwanden M, Richarz S (2023) Practical guide of vascular ultrasound in arteriovenous fistulae. Vasa 52:22–28CrossRefPubMed
19.
go back to reference Manov JJ, Mohan PP, Vazquez-Padron R (2022) Arteriovenous fistulas for hemodialysis: brief review and current problems. J Vasc Access 23:839–846CrossRefPubMed Manov JJ, Mohan PP, Vazquez-Padron R (2022) Arteriovenous fistulas for hemodialysis: brief review and current problems. J Vasc Access 23:839–846CrossRefPubMed
Metadata
Title
Evaluation of arteriovenous fistula for hemodialysis with a new generation digital stethoscope: a pilot study
Authors
Pierangela Presta
Nazareno Carullo
Annarita Armeni
Maria Teresa Zicarelli
Michela Musolino
Maria Giovanna Bianco
Salvatore Chiarella
Michele Andreucci
Antonino S. Fiorillo
Salvatore Andrea Pullano
Davide Bolignano
Giuseppe Coppolino
Publication date
13-12-2023
Publisher
Springer Netherlands
Published in
International Urology and Nephrology / Issue 5/2024
Print ISSN: 0301-1623
Electronic ISSN: 1573-2584
DOI
https://doi.org/10.1007/s11255-023-03895-5

Other articles of this Issue 5/2024

International Urology and Nephrology 5/2024 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine