Skip to main content
Top
Published in: International Urology and Nephrology 4/2013

01-08-2013 | Nephrology - Original Paper

Arm circumference: its importance for dialysis patients in the obesity era

Authors: Tekin Akpolat, Coşkun Kaya, Cengiz Utaş, Turgay Arinsoy, Hülya Taşkapan, Emre Erdem, M. Emin Yilmaz, Rezzan Ataman, Semra Bozfakioğlu, Çetin Özener, İbrahim Karayaylali, Rümeyza Kazancioğlu, Taner Çamsari, Mahmut Yavuz, Fevzi Ersoy, Soner Duman, Kenan Ateş

Published in: International Urology and Nephrology | Issue 4/2013

Login to get access

Abstract

Purpose

The purposes of this study were to investigate the association between arm circumference and body mass index (BMI) and to discuss problems, mainly arm circumference and cuff size mismatch, that could affect the reliability of home blood pressure monitoring (HBPM) among peritoneal dialysis (PD) and hemodialysis (HD) patients.

Methods

525 PD and 502 HD patients from 16 centers were included in the study. A two-part questionnaire was used to gather information from the participants. Arm circumferences were categorized into four groups according to the British Hypertension Society cuff size recommendations.

Results

Mean BMI and arm circumference of all participants were 25.0 kg/m2 and 27.6 cm, respectively. There was a significant correlation between BMI and arm circumference. The mean BMI and arm circumference values were higher in PD patients than in HD patients. Requirement of a large-sized adult cuff was more common among PD patients compared to HD patients (14 % vs 8 %, p = 0.002).

Conclusions

Since HBPM is a useful tool for clinicians to improve BP control, nephrologists should be aware of the problems related to HBPM in dialysis patients and take an active role to increase the reliability of HBPM.
Literature
1.
go back to reference Goldsmith D, Covic A (2009) Blood pressure control in CKD stage 5D patients-are we more or less certain what to do in 2009? Nephrol Dial Transpl 24:3597–3601CrossRef Goldsmith D, Covic A (2009) Blood pressure control in CKD stage 5D patients-are we more or less certain what to do in 2009? Nephrol Dial Transpl 24:3597–3601CrossRef
2.
go back to reference Agarwal R, Nissenson AR, Batlle D, Coyne DW, Trout JR, Warnock DG (2003) Prevalence, treatment, and control of hypertension in chronic hemodialysis patients in the United States. Am J Med 115:291–297PubMedCrossRef Agarwal R, Nissenson AR, Batlle D, Coyne DW, Trout JR, Warnock DG (2003) Prevalence, treatment, and control of hypertension in chronic hemodialysis patients in the United States. Am J Med 115:291–297PubMedCrossRef
3.
go back to reference Agarwal R, Peixoto AJ, Santos SF, Zoccali C (2009) Out-of-office blood pressure monitoring in chronic kidney disease. Blood Press Monit 14:2–11PubMedCrossRef Agarwal R, Peixoto AJ, Santos SF, Zoccali C (2009) Out-of-office blood pressure monitoring in chronic kidney disease. Blood Press Monit 14:2–11PubMedCrossRef
4.
go back to reference Pickering TG, Miller NH, Ogedegbe G, Krakoff LR, Artinian NT, Goff D et al (2008) Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society of Hypertension, and Preventive Cardiovascular Nurses Association. J Cardiovasc Nurs 23:299–323PubMedCrossRef Pickering TG, Miller NH, Ogedegbe G, Krakoff LR, Artinian NT, Goff D et al (2008) Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society of Hypertension, and Preventive Cardiovascular Nurses Association. J Cardiovasc Nurs 23:299–323PubMedCrossRef
5.
go back to reference Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN et al (2005) Recommendations for blood pressure measurement in human and experimental animals. Part: 1: blood pressure measurement in humans. A statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on high blood pressure research. Hypertension 45:142–161PubMed Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN et al (2005) Recommendations for blood pressure measurement in human and experimental animals. Part: 1: blood pressure measurement in humans. A statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on high blood pressure research. Hypertension 45:142–161PubMed
6.
go back to reference Parati G, Stergiou GS, Asmar R, Bilo G, de Leeuw P, Imai Y et al (2010) European Society of Hypertension practice guidelines for home blood pressure monitoring. J Hum Hypertens 24:779–785PubMedCrossRef Parati G, Stergiou GS, Asmar R, Bilo G, de Leeuw P, Imai Y et al (2010) European Society of Hypertension practice guidelines for home blood pressure monitoring. J Hum Hypertens 24:779–785PubMedCrossRef
7.
go back to reference Goldsmith D, Covic A (2011) Ambulatory blood pressure measurements in chronic kidney disease: ready to (rock and) roll? Arch Intern Med 171:1098–1099PubMedCrossRef Goldsmith D, Covic A (2011) Ambulatory blood pressure measurements in chronic kidney disease: ready to (rock and) roll? Arch Intern Med 171:1098–1099PubMedCrossRef
8.
go back to reference Agarwal R (2010) Managing hypertension using home blood pressure monitoring among haemodialysis patients–a call to action. Nephrol Dial Transpl 25:1766–1771CrossRef Agarwal R (2010) Managing hypertension using home blood pressure monitoring among haemodialysis patients–a call to action. Nephrol Dial Transpl 25:1766–1771CrossRef
10.
go back to reference Maxwell MH, Schroth PC, Waks AU, Karam M, Dornfeld LP (1982) Error in blood-pressure measurement due to incorrect cuff size in obese patients. Lancet 2:33–36PubMedCrossRef Maxwell MH, Schroth PC, Waks AU, Karam M, Dornfeld LP (1982) Error in blood-pressure measurement due to incorrect cuff size in obese patients. Lancet 2:33–36PubMedCrossRef
11.
go back to reference Kalaitzidis RG, Siamopoulos KC (2011) The role of obesity in kidney disease: recent findings and potential mechanisms. Int Urol Nephrol 43:771–784PubMedCrossRef Kalaitzidis RG, Siamopoulos KC (2011) The role of obesity in kidney disease: recent findings and potential mechanisms. Int Urol Nephrol 43:771–784PubMedCrossRef
12.
go back to reference Graves JW, Bailey KR, Sheps SG (2003) The changing distribution of arm circumferences in NHANES III and NHANES 2000 and its impact on the utility of the ‘standard adult’ blood pressure cuff. Blood Press Monit 8:223–227PubMedCrossRef Graves JW, Bailey KR, Sheps SG (2003) The changing distribution of arm circumferences in NHANES III and NHANES 2000 and its impact on the utility of the ‘standard adult’ blood pressure cuff. Blood Press Monit 8:223–227PubMedCrossRef
13.
go back to reference Bross R, Chandramohan G, Kovesdy CP, Oreopoulos A, Noori N, Golden S et al (2010) Am J Kidney Dis 55:885–896PubMedCrossRef Bross R, Chandramohan G, Kovesdy CP, Oreopoulos A, Noori N, Golden S et al (2010) Am J Kidney Dis 55:885–896PubMedCrossRef
14.
go back to reference Noori N, Kovesdy CP, Dukkipati R, Kim Y, Duong U, Bross R et al (2010) Survival predictability of lean and fat mass in men and women undergoing maintenance hemodialysis. Am J Clin Nutr 92:1060–1070PubMedCrossRef Noori N, Kovesdy CP, Dukkipati R, Kim Y, Duong U, Bross R et al (2010) Survival predictability of lean and fat mass in men and women undergoing maintenance hemodialysis. Am J Clin Nutr 92:1060–1070PubMedCrossRef
15.
go back to reference Noori N, Kovesdy CP, Bross R, Lee M, Oreopoulos A, Benner D et al (2011) Novel equations to estimate lean body mass in maintenance hemodialysis patients. Am J Kidney Dis 57:130–139PubMedCrossRef Noori N, Kovesdy CP, Bross R, Lee M, Oreopoulos A, Benner D et al (2011) Novel equations to estimate lean body mass in maintenance hemodialysis patients. Am J Kidney Dis 57:130–139PubMedCrossRef
16.
go back to reference Akpolat T (2010) Obesity, hypertension and home sphygmomanometer cuffs. Eur J Intern Med 21:338–340PubMedCrossRef Akpolat T (2010) Obesity, hypertension and home sphygmomanometer cuffs. Eur J Intern Med 21:338–340PubMedCrossRef
18.
go back to reference Finucane MM, Stevens GA, Cowan MJ, Danaei G, Lin JK, Paciorek CJ (2011) National, regional, and global trends in body-mass index since 1980: systematic analysis of health examination surveys and epidemiological studies with 960 country-years and 9·1 million participants. Lancet 377:557–567PubMedCrossRef Finucane MM, Stevens GA, Cowan MJ, Danaei G, Lin JK, Paciorek CJ (2011) National, regional, and global trends in body-mass index since 1980: systematic analysis of health examination surveys and epidemiological studies with 960 country-years and 9·1 million participants. Lancet 377:557–567PubMedCrossRef
19.
go back to reference Ricks J, Molnar MZ, Kovesdy CP, Kopple JD, Norris KC, Mehrotra R (2011) Racial and ethnic differences in the association of body mass index and survival in maintenance hemodialysis patients. Am J Kidney Dis 58:574–582PubMedCrossRef Ricks J, Molnar MZ, Kovesdy CP, Kopple JD, Norris KC, Mehrotra R (2011) Racial and ethnic differences in the association of body mass index and survival in maintenance hemodialysis patients. Am J Kidney Dis 58:574–582PubMedCrossRef
20.
go back to reference Peixoto AJ, Gray TA, Crowley ST (1999) Validation of the SpaceLabs 90207 ambulatory blood pressure device for hemodialysis patients. Blood Press Monit 4:217–221PubMed Peixoto AJ, Gray TA, Crowley ST (1999) Validation of the SpaceLabs 90207 ambulatory blood pressure device for hemodialysis patients. Blood Press Monit 4:217–221PubMed
21.
go back to reference Association for the Advancement of Medical Instrumentation (1993) American National Standard for Electronic or Automated Sphygmomanometers: ANSI/AAMI SP10—1993. AAMI, Arlington Association for the Advancement of Medical Instrumentation (1993) American National Standard for Electronic or Automated Sphygmomanometers: ANSI/AAMI SP10—1993. AAMI, Arlington
22.
go back to reference O’Brien E, Petrie J, Littler W, DeSweet M, Padfield PL, Altman DG et al (1993) The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices. J Hypertens 11(suppl 2):S43–S63 O’Brien E, Petrie J, Littler W, DeSweet M, Padfield PL, Altman DG et al (1993) The British Hypertension Society Protocol for the evaluation of blood pressure measuring devices. J Hypertens 11(suppl 2):S43–S63
23.
go back to reference O’Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R (2010) European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit 15:23–38PubMedCrossRef O’Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R (2010) European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit 15:23–38PubMedCrossRef
24.
go back to reference Omboni S, Riva I, Giglio I, Caldara G, Groppelli A, Parati G (2007) Validation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension. Blood Press Monit 12:233–242PubMedCrossRef Omboni S, Riva I, Giglio I, Caldara G, Groppelli A, Parati G (2007) Validation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension. Blood Press Monit 12:233–242PubMedCrossRef
25.
go back to reference Kanbay M, Afsar B, Gusbeth-Tatomir P, Covic A (2010) Arterial stiffness in dialysis patients: where are we now? Int Urol Nephrol 42:741–752PubMedCrossRef Kanbay M, Afsar B, Gusbeth-Tatomir P, Covic A (2010) Arterial stiffness in dialysis patients: where are we now? Int Urol Nephrol 42:741–752PubMedCrossRef
26.
go back to reference Thompson AM, Eguchi K, Reznik ME, Shah SS, Pickering TG (2007) Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Blood Press Monit 12:227–232PubMedCrossRef Thompson AM, Eguchi K, Reznik ME, Shah SS, Pickering TG (2007) Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Blood Press Monit 12:227–232PubMedCrossRef
27.
go back to reference Akpolat T, Erdem E, Aydogdu T (2012) Validation of the Omron M3 Intellisense (HEM-7051-E) Upper Arm Blood Pressure Monitor, for Self-Measurement, according to the European Society of Hypertension International Protocol Revision 2010 in a Stage 3–5 Chronic Kidney Disease Population. Kidney Blood Press Res 35:82–88PubMedCrossRef Akpolat T, Erdem E, Aydogdu T (2012) Validation of the Omron M3 Intellisense (HEM-7051-E) Upper Arm Blood Pressure Monitor, for Self-Measurement, according to the European Society of Hypertension International Protocol Revision 2010 in a Stage 3–5 Chronic Kidney Disease Population. Kidney Blood Press Res 35:82–88PubMedCrossRef
28.
go back to reference Semret M, Zidehsarai M, Agarwal R (2005) Accuracy of oscillometric blood pressure monitoring with concurrent auscultatory blood pressure in hemodialysis patients. Blood Press Monit 10:249–255PubMedCrossRef Semret M, Zidehsarai M, Agarwal R (2005) Accuracy of oscillometric blood pressure monitoring with concurrent auscultatory blood pressure in hemodialysis patients. Blood Press Monit 10:249–255PubMedCrossRef
29.
go back to reference Czarkowski M, Staszkow M, Kostyra K, Shebani Z, Niemczyk S, Matuszkiewicz-Rowińska J (2009) Determining the accuracy of blood pressure measurement by the Omron HEM-907 before and after hemodialysis. Blood Press Monit 14:232–238PubMedCrossRef Czarkowski M, Staszkow M, Kostyra K, Shebani Z, Niemczyk S, Matuszkiewicz-Rowińska J (2009) Determining the accuracy of blood pressure measurement by the Omron HEM-907 before and after hemodialysis. Blood Press Monit 14:232–238PubMedCrossRef
30.
go back to reference Imai Y, Otsuka K, Kawano Y, Shimada K, Hayashi H, Tochikubo O et al (2003) Japanese Society of hypertension (JSH) guidelines for self-monitoring of blood pressure at home. Hypertens Res 26:771–782PubMedCrossRef Imai Y, Otsuka K, Kawano Y, Shimada K, Hayashi H, Tochikubo O et al (2003) Japanese Society of hypertension (JSH) guidelines for self-monitoring of blood pressure at home. Hypertens Res 26:771–782PubMedCrossRef
33.
go back to reference Ogihara T, Kikuchi K, Matsuoka H, Fujita T, Higaki J, Horiuchi M et al (2009) The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2009). Hypertens Res 32:3–107PubMed Ogihara T, Kikuchi K, Matsuoka H, Fujita T, Higaki J, Horiuchi M et al (2009) The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2009). Hypertens Res 32:3–107PubMed
34.
go back to reference Obara T, Ohkubo T, Fukunaga H, Kobayashi M, Satoh M, Metoki H (2010) Practice and awareness of physicians regarding home blood pressure measurement in Japan. Hypertens Res 33:428–434PubMedCrossRef Obara T, Ohkubo T, Fukunaga H, Kobayashi M, Satoh M, Metoki H (2010) Practice and awareness of physicians regarding home blood pressure measurement in Japan. Hypertens Res 33:428–434PubMedCrossRef
35.
go back to reference Akpolat T, Erdem Y, Derici U, Erturk S, Caglar S, Hasanoglu E et al (2012) Use of home sphygmomanometers in Turkey: a nation-wide survey. Hypertens Res 35:356–361PubMedCrossRef Akpolat T, Erdem Y, Derici U, Erturk S, Caglar S, Hasanoglu E et al (2012) Use of home sphygmomanometers in Turkey: a nation-wide survey. Hypertens Res 35:356–361PubMedCrossRef
36.
go back to reference Akpolat T, Aydogdu T, Erdem E, Karatas A (2011) Inaccuracy of home sphygmomanometers: a perspective from clinical practice. Blood Press Monit 16:168–171PubMedCrossRef Akpolat T, Aydogdu T, Erdem E, Karatas A (2011) Inaccuracy of home sphygmomanometers: a perspective from clinical practice. Blood Press Monit 16:168–171PubMedCrossRef
37.
go back to reference Coleman A, Steel S, deGreeff A, Shennan A (2010) Validation of the Lloyds pharmacy BP11 oscillometric blood pressure monitor according to the international protocol of the European society of hypertension. Blood Press Monit 15:163–166PubMedCrossRef Coleman A, Steel S, deGreeff A, Shennan A (2010) Validation of the Lloyds pharmacy BP11 oscillometric blood pressure monitor according to the international protocol of the European society of hypertension. Blood Press Monit 15:163–166PubMedCrossRef
38.
go back to reference O’Brien E (2001) State of the market for devices for blood pressure measurement. Blood Press Monit 6:281–286PubMedCrossRef O’Brien E (2001) State of the market for devices for blood pressure measurement. Blood Press Monit 6:281–286PubMedCrossRef
Metadata
Title
Arm circumference: its importance for dialysis patients in the obesity era
Authors
Tekin Akpolat
Coşkun Kaya
Cengiz Utaş
Turgay Arinsoy
Hülya Taşkapan
Emre Erdem
M. Emin Yilmaz
Rezzan Ataman
Semra Bozfakioğlu
Çetin Özener
İbrahim Karayaylali
Rümeyza Kazancioğlu
Taner Çamsari
Mahmut Yavuz
Fevzi Ersoy
Soner Duman
Kenan Ateş
Publication date
01-08-2013
Publisher
Springer Netherlands
Published in
International Urology and Nephrology / Issue 4/2013
Print ISSN: 0301-1623
Electronic ISSN: 1573-2584
DOI
https://doi.org/10.1007/s11255-012-0219-8

Other articles of this Issue 4/2013

International Urology and Nephrology 4/2013 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.