Abstract

Objectives

Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes.

Methods

One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0–6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level).

Results

Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2–3) vs 2(1–2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl−1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649—-0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371—-0.001, p = 0.048) were predictors for lower platelet levels.

Conclusion

Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.
Appendix
Available only for authorised users
Literature
1.
go back to reference Stegmeier P, Schlömicher M, Stiegler H, Strauch JT, Bechtel JFM. Thrombocytopenia after implantation of the Perceval S aortic bioprosthesis. J Thorac Cardiovasc Surg. 2020;160(1):61–8.e8.CrossRefPubMed Stegmeier P, Schlömicher M, Stiegler H, Strauch JT, Bechtel JFM. Thrombocytopenia after implantation of the Perceval S aortic bioprosthesis. J Thorac Cardiovasc Surg. 2020;160(1):61–8.e8.CrossRefPubMed
2.
go back to reference Mujtaba SS, Ledingham S, Shah AR, Schueler S, Clark S, Pillay T. Thrombocytopenia after aortic valve replacement: comparison between sutureless perceval s valve and perimount magna ease bioprosthesis. Braz J Cardiovasc Surg. 2018;33(2):169–75.CrossRefPubMedPubMedCentral Mujtaba SS, Ledingham S, Shah AR, Schueler S, Clark S, Pillay T. Thrombocytopenia after aortic valve replacement: comparison between sutureless perceval s valve and perimount magna ease bioprosthesis. Braz J Cardiovasc Surg. 2018;33(2):169–75.CrossRefPubMedPubMedCentral
3.
go back to reference Lorusso R, Jiritano F, Roselli E, Shrestha M, Folliguet T, Meuris B, et al. Perioperative platelet reduction after sutureless or stented valve implantation: results from the PERSIST-AVR controlled randomized trial. Eur J Cardiothorac Surg. 2021;60(6):1359–65.CrossRefPubMed Lorusso R, Jiritano F, Roselli E, Shrestha M, Folliguet T, Meuris B, et al. Perioperative platelet reduction after sutureless or stented valve implantation: results from the PERSIST-AVR controlled randomized trial. Eur J Cardiothorac Surg. 2021;60(6):1359–65.CrossRefPubMed
4.
go back to reference Jiritano F, Cristodoro L, Malta E, Mastroroberto P. Thrombocytopenia after sutureless aortic valve implantation: comparison between Intuity and Perceval bioprostheses. J Thorac Cardiovasc Surg. 2016;152(6):1631–3.CrossRefPubMed Jiritano F, Cristodoro L, Malta E, Mastroroberto P. Thrombocytopenia after sutureless aortic valve implantation: comparison between Intuity and Perceval bioprostheses. J Thorac Cardiovasc Surg. 2016;152(6):1631–3.CrossRefPubMed
5.
go back to reference Haeussler A, Ntinopoulos V, Rings L, Papadopoulos N, Hoti G, Fleckenstein P et al. Thrombocytopenia after implantation of the perceval, intuity, and sapien aortic valve prostheses. Thorac Cardiovasc Surg. 2023;71(7):550–6. https://doi.org/10.1055/s-0042-1757893. Haeussler A, Ntinopoulos V, Rings L, Papadopoulos N, Hoti G, Fleckenstein P et al. Thrombocytopenia after implantation of the perceval, intuity, and sapien aortic valve prostheses. Thorac Cardiovasc Surg. 2023;71(7):550–6. https://​doi.​org/​10.​1055/​s-0042-1757893.
6.
go back to reference Albacker TB. Thrombocytopenia associated with perceval sutureless aortic valve replacement in elderly patients: a word of caution. Heart Surg Forum. 2015;18(3):E93–7.CrossRef Albacker TB. Thrombocytopenia associated with perceval sutureless aortic valve replacement in elderly patients: a word of caution. Heart Surg Forum. 2015;18(3):E93–7.CrossRef
7.
go back to reference Stanger O, Grabherr M, Gahl B, Longnus S, Meinitzer A, Fiedler M, et al. Thrombocytopaenia after aortic valve replacement with stented, stentless and sutureless bioprostheses. Eur J Cardiothorac Surg. 2017;51(2):340–6.PubMed Stanger O, Grabherr M, Gahl B, Longnus S, Meinitzer A, Fiedler M, et al. Thrombocytopaenia after aortic valve replacement with stented, stentless and sutureless bioprostheses. Eur J Cardiothorac Surg. 2017;51(2):340–6.PubMed
8.
go back to reference Jiritano F, Santarpino G, Serraino GF, ten Cate H, Matteucci M, Fina D, et al. Peri-procedural thrombocytopenia after aortic bioprosthesis implant: a systematic review and meta-analysis comparison among conventional, stentless, rapid-deployment, and transcatheter valves. Int J Cardiol. 2019;296:43–50.CrossRefPubMed Jiritano F, Santarpino G, Serraino GF, ten Cate H, Matteucci M, Fina D, et al. Peri-procedural thrombocytopenia after aortic bioprosthesis implant: a systematic review and meta-analysis comparison among conventional, stentless, rapid-deployment, and transcatheter valves. Int J Cardiol. 2019;296:43–50.CrossRefPubMed
9.
go back to reference Takahashi S, Yokoyama N, Watanabe Y, Katayama T, Hioki H, Yamamoto H, et al. Predictor and mid-term outcome of clinically significant thrombocytopenia after transcatheter aortic valve selection. Circ J. 2020;84(6):1020–7.CrossRefPubMed Takahashi S, Yokoyama N, Watanabe Y, Katayama T, Hioki H, Yamamoto H, et al. Predictor and mid-term outcome of clinically significant thrombocytopenia after transcatheter aortic valve selection. Circ J. 2020;84(6):1020–7.CrossRefPubMed
11.
go back to reference van Straten AHM, Hamad MAS, Berreklouw E, ter Woorst JF, Martens EJ, Tan MESH. Thrombocytopenia after aortic valve replacement: comparison between mechanical and biological valves. J Heart Valve Dis. 2010;19(3):394–9.PubMed van Straten AHM, Hamad MAS, Berreklouw E, ter Woorst JF, Martens EJ, Tan MESH. Thrombocytopenia after aortic valve replacement: comparison between mechanical and biological valves. J Heart Valve Dis. 2010;19(3):394–9.PubMed
12.
16.
go back to reference Sena A, Ferreira R, Nobre M, Ferreira H, Junqueira N, Velho T et al. Platelet count drop after rapid deployment aortic valve implantation. Rev Port Cir Cardiotorac Vasc. 2020;27(2):91–6. Sena A, Ferreira R, Nobre M, Ferreira H, Junqueira N, Velho T et al. Platelet count drop after rapid deployment aortic valve implantation. Rev Port Cir Cardiotorac Vasc. 2020;27(2):91–6. 
19.
go back to reference Pulcinelli FM, Sebastiani S, Pesciotti M, Pignatelli P, Gazzaniga PP, Daniel JL. Nickel enhances collagen-induced platelet activation acting by increasing the organization of the cytoskeleton. Thromb Haemost. 1998;79(2):395–9.CrossRefPubMed Pulcinelli FM, Sebastiani S, Pesciotti M, Pignatelli P, Gazzaniga PP, Daniel JL. Nickel enhances collagen-induced platelet activation acting by increasing the organization of the cytoskeleton. Thromb Haemost. 1998;79(2):395–9.CrossRefPubMed
20.
go back to reference Chen CY, Lin TH. Effects of nickel chloride on human platelets: enhancement of lipid peroxidation, inhibition of aggregation and interaction with ascorbic acid. J Toxicol Environ Health A. 2001;62(6):431–8.CrossRefPubMed Chen CY, Lin TH. Effects of nickel chloride on human platelets: enhancement of lipid peroxidation, inhibition of aggregation and interaction with ascorbic acid. J Toxicol Environ Health A. 2001;62(6):431–8.CrossRefPubMed
Metadata
Title
Thrombocytopenia after sutureless and standard stented aortic valve replacement: a retrospective analysis of risk factors, clinical course, and early outcome
Authors
Alicja Zientara
Mohammad Yousuf Salmasi
Bella Milan-Chhatrisha
Sharan Kapadia
Ryan Bashir
Ian Cummings
Cesare Quarto
George Asimakopoulos
Publication date
01-12-2024
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2024
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-024-02755-2

Other articles of this Issue 1/2024

Journal of Cardiothoracic Surgery 1/2024 Go to the issue