Skip to main content
Top
Published in: HSS Journal ® 1/2016

01-02-2016 | Original Article

Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study

Authors: Peter K. Sculco, MD, Alexander S. McLawhorn, MD, MBA, Kaitlin M. Carroll, BS, Benjamin A. McArthur, MD, David J. Mayman, MD

Published in: HSS Journal ® | Issue 1/2016

Login to get access

Abstract

Background

Measuring acetabular anteversion is relevant to routine follow-up of total hip arthroplasties (THAs) and for malfunctioning THAs. Imageless navigation facilitates acetabular component orientation relative to the anterior pelvic plane (APP) or to the APP adjusted for sagittal pelvic tilt (PT). The optimal plain radiographic method for the postoperative assessment of anteversion is not agreed upon.

Questions/Purposes

(1) Do anteversion measurements on plain radiographs correlate more with APP anteversion or PT-adjusted anteversion? (2) Do measurements of anteversion performed on supine anteroposterior (AP) radiographs more accurately reflect intraoperative anteversion values for navigated THA compared to anteversion measured on cross-table lateral (CL) radiographs?

Methods

Seventy patients receiving primary navigated THA were included. APP and PT-adjusted anteversion were recorded; the latter defined the intraoperative target for anteversion. Postoperative anteversion was measured on supine AP pelvis radiographs with computer software and CL radiographs with conventional methods. Intraoperative measurements were used as the reference standards for comparisons.

Results

Mean intraoperative APP anteversion was 20.6° ± 5.6°. Mean intraoperative PT-adjusted anteversion was 22.9° ± 4.5°. Mean anteversion was 22.7° ± 4.7° on AP radiographs and 27.2° ± 4.2° on CL radiographs (p < 0.001). Only correlations between PT-adjusted anteversion and radiographic assessments of anteversion were significant. The mean difference between PT-adjusted anteversion and anteversion on AP radiographs was −0.2° ± 4.3°, while the mean difference between the PT-adjusted anteversion and anteversion measured on CL radiographs was 4.3 ± 5.1° (p < 0.001).

Conclusion

Plain film assessment of anteversion was more accurate on supine AP radiographs than on CL radiographs, which overestimated acetabular anteversion.
Appendix
Available only for authorised users
Literature
1.
go back to reference Arai N, Nakamura S, Matsushita T. Difference between 2 measurement methods of version angles of the acetabular component. J Arthroplasty. 2007; 22(5): 715-720.CrossRefPubMed Arai N, Nakamura S, Matsushita T. Difference between 2 measurement methods of version angles of the acetabular component. J Arthroplasty. 2007; 22(5): 715-720.CrossRefPubMed
2.
go back to reference Barrack RL. Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg. 2003; 11(2): 89-99.PubMed Barrack RL. Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg. 2003; 11(2): 89-99.PubMed
3.
go back to reference Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stöckl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br. 2005; 87(6): 762-769.CrossRefPubMed Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stöckl B. Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br. 2005; 87(6): 762-769.CrossRefPubMed
4.
go back to reference Blondel B, Parratte S, Tropiano P, Pauly V, Aubaniac JM, Argenson JN. Pelvic tilt measurement before and after total hip arthroplasty. Orthop Traumatol Surg Res. 2009; 95(8): 568-572.CrossRefPubMed Blondel B, Parratte S, Tropiano P, Pauly V, Aubaniac JM, Argenson JN. Pelvic tilt measurement before and after total hip arthroplasty. Orthop Traumatol Surg Res. 2009; 95(8): 568-572.CrossRefPubMed
5.
go back to reference Ghelman B, Kepler CK, Lyman S, Della Valle AG. CT outperforms radiography for determination of acetabular cup version after THA. Clin Orthop Relat Res. 2009; 467(9): 2362-2370.PubMedCentralCrossRefPubMed Ghelman B, Kepler CK, Lyman S, Della Valle AG. CT outperforms radiography for determination of acetabular cup version after THA. Clin Orthop Relat Res. 2009; 467(9): 2362-2370.PubMedCentralCrossRefPubMed
6.
go back to reference Grammatopoulos G, Thomas GE, Pandit H, Beard DJ, Gill HS, Murray DW. The effect of orientation of the acetabular component on outcome following total hip arthroplasty with small diameter hard-on-soft bearings. Bone Joint J. 2015; 97-B(2): 164-172.CrossRefPubMed Grammatopoulos G, Thomas GE, Pandit H, Beard DJ, Gill HS, Murray DW. The effect of orientation of the acetabular component on outcome following total hip arthroplasty with small diameter hard-on-soft bearings. Bone Joint J. 2015; 97-B(2): 164-172.CrossRefPubMed
7.
go back to reference Haaker RG, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB. Comparison of conventional versus computer-navigated acetabular component insertion. J Arthroplasty. 2007; 22(2): 151-159.CrossRefPubMed Haaker RG, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB. Comparison of conventional versus computer-navigated acetabular component insertion. J Arthroplasty. 2007; 22(2): 151-159.CrossRefPubMed
8.
go back to reference Hassan DM, Johnston GH, Dust WN, Watson LG, Cassidy D. Radiographic calculation of anteversion in acetabular prostheses. J Arthroplasty. 1995; 10(3): 369-372.CrossRefPubMed Hassan DM, Johnston GH, Dust WN, Watson LG, Cassidy D. Radiographic calculation of anteversion in acetabular prostheses. J Arthroplasty. 1995; 10(3): 369-372.CrossRefPubMed
9.
go back to reference Kalteis T, Handel M, Herold T, Perlick L, Baethis H, Grifka J. Greater accuracy in positioning of the acetabular cup by using an image-free navigation system. Int Orthop. 2005; 29(5): 272-276.PubMedCentralCrossRefPubMed Kalteis T, Handel M, Herold T, Perlick L, Baethis H, Grifka J. Greater accuracy in positioning of the acetabular cup by using an image-free navigation system. Int Orthop. 2005; 29(5): 272-276.PubMedCentralCrossRefPubMed
10.
go back to reference Krismer M, Bauer R, Tschupik J, Mayrhofer P. EBRA: a method to measure migration of acetabular components. J Biomech. 1995; 28(10): 1225-1236.CrossRefPubMed Krismer M, Bauer R, Tschupik J, Mayrhofer P. EBRA: a method to measure migration of acetabular components. J Biomech. 1995; 28(10): 1225-1236.CrossRefPubMed
11.
12.
go back to reference Lewinnek GE, Lewis JL, Tarr R, et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978; 60: 217.PubMed Lewinnek GE, Lewis JL, Tarr R, et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978; 60: 217.PubMed
13.
go back to reference Lu M, Zhou YX, Du H, Zhang J, Liu J. Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs. Clin Orthop Relat Res. 2013; 471(9): 2987-2994.PubMedCentralCrossRefPubMed Lu M, Zhou YX, Du H, Zhang J, Liu J. Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs. Clin Orthop Relat Res. 2013; 471(9): 2987-2994.PubMedCentralCrossRefPubMed
14.
go back to reference Maratt JD, Esposito CI, McLawhorn AS, Jerabek SA, Padgett DE, Mayman DJ. Pelvic tilt in patients undergoing total hip arthroplasty: when does it matter? J Arthroplasty. 2015; 30(3): 387-391.CrossRefPubMed Maratt JD, Esposito CI, McLawhorn AS, Jerabek SA, Padgett DE, Mayman DJ. Pelvic tilt in patients undergoing total hip arthroplasty: when does it matter? J Arthroplasty. 2015; 30(3): 387-391.CrossRefPubMed
15.
go back to reference McArthur B, Cross M, Geatrakas C, Mayman D, Ghelman B. Measuring acetabular component version after THA: CT or plain radiograph? Clin Orthop Relat Res. 2012; 470(10): 2810-2818.PubMedCentralCrossRefPubMed McArthur B, Cross M, Geatrakas C, Mayman D, Ghelman B. Measuring acetabular component version after THA: CT or plain radiograph? Clin Orthop Relat Res. 2012; 470(10): 2810-2818.PubMedCentralCrossRefPubMed
16.
go back to reference McLawhorn AS, Sculco PK, Weeks KD, Nam D, Mayman DJ. Targeting a New Safe Zone: A Step in the Development of Patient-Specific Component Positioning for Total Hip Arthroplasty. Am J Orthop (Belle Mead NJ). 2015; 44(6): 270-276. McLawhorn AS, Sculco PK, Weeks KD, Nam D, Mayman DJ. Targeting a New Safe Zone: A Step in the Development of Patient-Specific Component Positioning for Total Hip Arthroplasty. Am J Orthop (Belle Mead NJ). 2015; 44(6): 270-276.
17.
go back to reference Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993; 75: 228-232.PubMed Murray DW. The definition and measurement of acetabular orientation. J Bone Joint Surg Br. 1993; 75: 228-232.PubMed
18.
go back to reference Nho JH, Lee YK, Kim HJ, Ha YC, Suh YS, Koo KH. Reliability and validity of measuring version of the acetabular component. J Bone Joint Surg Br. 2012; 94(1): 32-36.CrossRefPubMed Nho JH, Lee YK, Kim HJ, Ha YC, Suh YS, Koo KH. Reliability and validity of measuring version of the acetabular component. J Bone Joint Surg Br. 2012; 94(1): 32-36.CrossRefPubMed
19.
go back to reference Nishino H, Nakamura S, Arai N, Matsushita T. Accuracy and precision of version angle measurements of the acetabular component after total hip arthroplasty. J Arthroplasty. 2013; 28(9): 1644-1647.CrossRefPubMed Nishino H, Nakamura S, Arai N, Matsushita T. Accuracy and precision of version angle measurements of the acetabular component after total hip arthroplasty. J Arthroplasty. 2013; 28(9): 1644-1647.CrossRefPubMed
20.
go back to reference Nogler M, Kessler O, Prassl A, et al. Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop Relat Res. 2004; 426(426): 159-163.CrossRefPubMed Nogler M, Kessler O, Prassl A, et al. Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop Relat Res. 2004; 426(426): 159-163.CrossRefPubMed
21.
go back to reference Pulos N, Tiberi JV 3rd, Schmalzried TP. Measuring acetabular component position on lateral radiographs: ischio-lateral method. Bull NYU Hosp Jt Dis. 2011; 69(Suppl 1): S84-S89.PubMed Pulos N, Tiberi JV 3rd, Schmalzried TP. Measuring acetabular component position on lateral radiographs: ischio-lateral method. Bull NYU Hosp Jt Dis. 2011; 69(Suppl 1): S84-S89.PubMed
22.
go back to reference Ryan JA, Jamali AA, Bargar WL. Accuracy of computer navigation for acetabular component placement in THA. Clin Orthop Relat Res. 2010; 468(1): 169-177.PubMedCentralCrossRefPubMed Ryan JA, Jamali AA, Bargar WL. Accuracy of computer navigation for acetabular component placement in THA. Clin Orthop Relat Res. 2010; 468(1): 169-177.PubMedCentralCrossRefPubMed
23.
go back to reference Sendtner E, Schuster T, Worner M, Kalteis T, Grifka J, Renkawitz T. Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position. Int Orthop. 2011; 35(6): 809-815.PubMedCentralCrossRefPubMed Sendtner E, Schuster T, Worner M, Kalteis T, Grifka J, Renkawitz T. Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus position. Int Orthop. 2011; 35(6): 809-815.PubMedCentralCrossRefPubMed
24.
go back to reference Snyder GM, Lozano Calderon SA, Lucas PA, Russinoff S. Accuracy of computer-navigated total hip arthroplasty. J Arthroplasty. 2012; 27(3): 415-420.CrossRefPubMed Snyder GM, Lozano Calderon SA, Lucas PA, Russinoff S. Accuracy of computer-navigated total hip arthroplasty. J Arthroplasty. 2012; 27(3): 415-420.CrossRefPubMed
25.
go back to reference Steppacher SD, Tannast M, Zheng G, et al. Validation of a new method for determination of cup orientation in THA. J Orthop Res. 2009; 27(12): 1583-1588.CrossRefPubMed Steppacher SD, Tannast M, Zheng G, et al. Validation of a new method for determination of cup orientation in THA. J Orthop Res. 2009; 27(12): 1583-1588.CrossRefPubMed
26.
go back to reference Tiberi JV, Pulos N, Kertzner M, Schmalzried TP. A more reliable method to assess acetabular component position. Clin Orthop Relat Res. 2012; 470(2): 471-476.PubMedCentralCrossRefPubMed Tiberi JV, Pulos N, Kertzner M, Schmalzried TP. A more reliable method to assess acetabular component position. Clin Orthop Relat Res. 2012; 470(2): 471-476.PubMedCentralCrossRefPubMed
27.
go back to reference Wan Z, Boutary M, Dorr LD. The influence of acetabular component position on wear in total hip arthroplasty. J Arthroplasty. 2008; 23(1): 51-56.CrossRefPubMed Wan Z, Boutary M, Dorr LD. The influence of acetabular component position on wear in total hip arthroplasty. J Arthroplasty. 2008; 23(1): 51-56.CrossRefPubMed
28.
go back to reference Woo RY, Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg Am. 1982; 64(9): 1295-1306.PubMed Woo RY, Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg Am. 1982; 64(9): 1295-1306.PubMed
Metadata
Title
Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study
Authors
Peter K. Sculco, MD
Alexander S. McLawhorn, MD, MBA
Kaitlin M. Carroll, BS
Benjamin A. McArthur, MD
David J. Mayman, MD
Publication date
01-02-2016
Publisher
Springer US
Published in
HSS Journal ® / Issue 1/2016
Print ISSN: 1556-3316
Electronic ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-015-9472-6

Other articles of this Issue 1/2016

HSS Journal ® 1/2016 Go to the issue