Skip to main content
Top
Published in: European Journal of Trauma and Emergency Surgery 6/2019

01-12-2019 | Original Paper

Anteromedial femoral neck plate with cannulated screws for the treatment of irreducible displaced femoral neck fracture in young patients: a preliminary study

Authors: Linbo Zhuang, Lisheng Wang, Dongming Xu, Zhiyong Wang

Published in: European Journal of Trauma and Emergency Surgery | Issue 6/2019

Login to get access

Abstract

Backgrounds

Although most displaced femoral neck fractures of young patients can be repositioned successfully by closed reduction, there are still some can not repositioned successfully by this way and open reductions are required. This type of fracture was defined as irreducible displaced femoral neck fracture in this study. The purpose of this study was to introduce a new technique using anteromedial femoral neck plate with cannulated screws fixation by open reduction for the treatment of irreducible displaced femoral neck fractures in young patients.

Methods

Totally 26 patients with irreducible displaced femoral neck fracture treated by this technique were retrospectively reviewed. This technique included three major steps: open reduction of femoral neck fracture was performed via the modified anterior approach of hip joint, anteromedial femoral neck plate was fixed to the femoral neck, and two cannulated compression screws were inserted in the femoral neck inside.

Results

All patients were followed up with an average of 18months (range 12–30 months). Radiological and clinical outcomes were evaluated. The fracture union was achieved in 24 patients (92.3%) with an average duration of 4.5 months (range 3.8–10 months). Nonunion was not observed in all cases. Avascular necrosis of femoral head was identified in two patients (7.7%). Clinical outcomes of 24 hips with satisfactory union were evaluated by the Harris Hip Scores (HHS), excellent outcomes were achieved in 20 cases (HHS ≧ 90), fair outcomes in 3 cases (80 ≦ HHS < 90), and poor outcome in 1 case (HHS < 80).

Conclusions

Anteromedial femoral neck plate with cannulated screws fixation by open reduction is an alternative therapeutic method for the irreducible displaced femoral neck fracture in young patients, with low incidence of complications including nonunion and avascular necrosis.
Literature
1.
go back to reference Bensen AS, Jakobsen T, Krarup N. Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures. Int Orthop. 2014;38(6):1241–5.CrossRef Bensen AS, Jakobsen T, Krarup N. Dual mobility cup reduces dislocation and re-operation when used to treat displaced femoral neck fractures. Int Orthop. 2014;38(6):1241–5.CrossRef
2.
go back to reference Liu Y, Tao X, Wang P, Zhang Z, Zhang W, Qi Q. Meta-analysis of randomised controlled trials comparing unipolar with bipolar hemiarthroplasty for displaced femoral-neck fractures. Int Orthop. 2014;38(8):1691–6.CrossRef Liu Y, Tao X, Wang P, Zhang Z, Zhang W, Qi Q. Meta-analysis of randomised controlled trials comparing unipolar with bipolar hemiarthroplasty for displaced femoral-neck fractures. Int Orthop. 2014;38(8):1691–6.CrossRef
3.
go back to reference Gierer P, Mittlmeier T. Femoral neck fracture. Unfallchirurg. 2015;118(3):259–69.CrossRef Gierer P, Mittlmeier T. Femoral neck fracture. Unfallchirurg. 2015;118(3):259–69.CrossRef
4.
go back to reference Davidovitch RI, Jordan CJ, Egol KA, Vrahas MS. Challenges in the treatment of femoral neck fractures in the nonelderly adult. J Trauma. 2010;68(1):236–42.CrossRef Davidovitch RI, Jordan CJ, Egol KA, Vrahas MS. Challenges in the treatment of femoral neck fractures in the nonelderly adult. J Trauma. 2010;68(1):236–42.CrossRef
5.
go back to reference Elgeidi A, El Negery A, Abdellatif MS, El Moghazy N. Dynamic hip screws and fibular strut graft for fixation of fresh femoral neck fracture with posterior comminution. Arch Orthop Trauma Surg. 2017;137(10):1363–9.CrossRef Elgeidi A, El Negery A, Abdellatif MS, El Moghazy N. Dynamic hip screws and fibular strut graft for fixation of fresh femoral neck fracture with posterior comminution. Arch Orthop Trauma Surg. 2017;137(10):1363–9.CrossRef
6.
go back to reference Yu XB, Zhao DW, Zhong SZ, Liu BY, Wang BJ, Liu YP, Zhang Y, Cui DP, Fu DP, Xie H. Prospective and comparative analysis of internal fixation of femoral neck fractures with or without vascularized iliac graft in young adults. Orthopedics. 2013;36(2):132–8.CrossRef Yu XB, Zhao DW, Zhong SZ, Liu BY, Wang BJ, Liu YP, Zhang Y, Cui DP, Fu DP, Xie H. Prospective and comparative analysis of internal fixation of femoral neck fractures with or without vascularized iliac graft in young adults. Orthopedics. 2013;36(2):132–8.CrossRef
7.
go back to reference Souder CD, Brennan ML, Brennan KL, Song J, Williams J, Chaput C. The rate of contralateral proximal femoral fracture following closed reduction and percutaneous pinning compared with arthroplasty for the treatment of femoral neck fractures. J Bone Joint Surg Am. 2012;94(5):418–25.CrossRef Souder CD, Brennan ML, Brennan KL, Song J, Williams J, Chaput C. The rate of contralateral proximal femoral fracture following closed reduction and percutaneous pinning compared with arthroplasty for the treatment of femoral neck fractures. J Bone Joint Surg Am. 2012;94(5):418–25.CrossRef
8.
go back to reference Araujo TP, Guimaraes TM, Andrade-Silva FB, Kojima KE, Silva Jdos S. Influence of time to surgery on the incidence of complications in femoral neck fracture treated with cannulated screws. Injury. 2014;5:S36–S39. Araujo TP, Guimaraes TM, Andrade-Silva FB, Kojima KE, Silva Jdos S. Influence of time to surgery on the incidence of complications in femoral neck fracture treated with cannulated screws. Injury. 2014;5:S36–S39.
9.
go back to reference Lin D, Lian K, Ding Z, Zhai W, Hong J. Proximal femoral locking plate with cannulated screws for the treatment of femoral neck fractures. Orthopedics. 2012;35(1):e1–e5. Lin D, Lian K, Ding Z, Zhai W, Hong J. Proximal femoral locking plate with cannulated screws for the treatment of femoral neck fractures. Orthopedics. 2012;35(1):e1–e5.
10.
go back to reference Samsami S, Saberi S, Sadighi S, Rouhi G. Comparison of three fixation methods for femoral neck fracture in young adults: experimental and numerial investigations. J Med Biol Eng. 2015;35(5):566–79.CrossRef Samsami S, Saberi S, Sadighi S, Rouhi G. Comparison of three fixation methods for femoral neck fracture in young adults: experimental and numerial investigations. J Med Biol Eng. 2015;35(5):566–79.CrossRef
11.
go back to reference Yu X, Zhao D, Huang S, Wang B, Zhang X, Wang W, Wei X. Biodegradable magnesium screws and vascularized iliac grafting for displaced femoral neck fracture in young adults. BMC Musculoskelet Disord. 2015;16:329.CrossRef Yu X, Zhao D, Huang S, Wang B, Zhang X, Wang W, Wei X. Biodegradable magnesium screws and vascularized iliac grafting for displaced femoral neck fracture in young adults. BMC Musculoskelet Disord. 2015;16:329.CrossRef
12.
go back to reference Chammout GK, Mukka SS, Carisson T, Neander GF, Stark AW, Skoldenberg OG. Total hip replacement versus open reduction and internal fixation of displaced femoral neck fractures: a randomized long-term follow-up study. J Bong Joint Surg Am. 2012;94(21):1921–8.CrossRef Chammout GK, Mukka SS, Carisson T, Neander GF, Stark AW, Skoldenberg OG. Total hip replacement versus open reduction and internal fixation of displaced femoral neck fractures: a randomized long-term follow-up study. J Bong Joint Surg Am. 2012;94(21):1921–8.CrossRef
13.
go back to reference Kapoor A, Deety LV, John VZ, Devadoss S, Devadoss A. Management of neglected femoral neck fractures and nonunion using a novel triple surgery combination: an Indian experience. Int J Low Extrem Wounds. 2012;11(1):49–58.CrossRef Kapoor A, Deety LV, John VZ, Devadoss S, Devadoss A. Management of neglected femoral neck fractures and nonunion using a novel triple surgery combination: an Indian experience. Int J Low Extrem Wounds. 2012;11(1):49–58.CrossRef
14.
go back to reference Xie X, zhang C, Jin D, Chen S, Gao Y. Free vascularised fibular graft for neglected femoral neck fractures in young adults. Hip Int. 2012;22(3):319–23.CrossRef Xie X, zhang C, Jin D, Chen S, Gao Y. Free vascularised fibular graft for neglected femoral neck fractures in young adults. Hip Int. 2012;22(3):319–23.CrossRef
15.
go back to reference Mathews V, Cabanela ME. Femoral neck nonunion treatment. Clin Orthop Relat Res. 2004;419:57–64.CrossRef Mathews V, Cabanela ME. Femoral neck nonunion treatment. Clin Orthop Relat Res. 2004;419:57–64.CrossRef
16.
go back to reference Kalra M, Anand S. Valgus intertrochanteric osteotomy for neglected femoral neck fractures in young adults. Int Orthop. 2001;25(6):363–6.CrossRef Kalra M, Anand S. Valgus intertrochanteric osteotomy for neglected femoral neck fractures in young adults. Int Orthop. 2001;25(6):363–6.CrossRef
17.
go back to reference Sen RK, Tripathy SK, Goyal T, Aggarwal S, Tahasildar N, Singh D, Singh AK. Osteosynthesis of femoral-neck nonunion with angle blade plate and autogenous fibular graft. Int Orthop. 2012;36(4):827–32.CrossRef Sen RK, Tripathy SK, Goyal T, Aggarwal S, Tahasildar N, Singh D, Singh AK. Osteosynthesis of femoral-neck nonunion with angle blade plate and autogenous fibular graft. Int Orthop. 2012;36(4):827–32.CrossRef
18.
go back to reference LeCroy CM, Rizzo M, Gunneson EE, Urbaniak JR. Free vascularized fibular bone grafting in the management of femoral neck nonunion in patients younger than fifty years. J Orthop Trauma. 2002;16(7):464–72.CrossRef LeCroy CM, Rizzo M, Gunneson EE, Urbaniak JR. Free vascularized fibular bone grafting in the management of femoral neck nonunion in patients younger than fifty years. J Orthop Trauma. 2002;16(7):464–72.CrossRef
19.
go back to reference Steinberg ME, Hayken GD, Steinberg DR. A quantitative system for staging avascular necrosis. J Bone Joint Surg Br. 1995;77(1):34–41.CrossRef Steinberg ME, Hayken GD, Steinberg DR. A quantitative system for staging avascular necrosis. J Bone Joint Surg Br. 1995;77(1):34–41.CrossRef
20.
go back to reference Perren SM. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res. 1979;138:175–96. Perren SM. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res. 1979;138:175–96.
21.
go back to reference Claes LE, Heigele CA. Magnitudes of local stress and strain along bony surfaces predict the course and type of facture healing. J Biomech. 1999;32(3):255–66.CrossRef Claes LE, Heigele CA. Magnitudes of local stress and strain along bony surfaces predict the course and type of facture healing. J Biomech. 1999;32(3):255–66.CrossRef
22.
go back to reference Siavashi B, Aalirezaei A, Moosavi M, Golbakhsh MR, Savadkoohi D, Zehtab MJ. A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults. Int Orthop. 2015;39(10):2069–71.CrossRef Siavashi B, Aalirezaei A, Moosavi M, Golbakhsh MR, Savadkoohi D, Zehtab MJ. A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults. Int Orthop. 2015;39(10):2069–71.CrossRef
23.
go back to reference Panteli M, Rodham P, Giannoudis PV. Biomechanical rationale for implant choice in femoral neck fracture fixation in the non-elderly. Injury. 2015;46(3):445–52.CrossRef Panteli M, Rodham P, Giannoudis PV. Biomechanical rationale for implant choice in femoral neck fracture fixation in the non-elderly. Injury. 2015;46(3):445–52.CrossRef
24.
go back to reference Su Y, Chen W, Zhang Q, Li B, Li Z, Guo M, Pan J, Zhang Y. An irreducible variant of femoral neck fracture: a minimally traumatic reduction technique. Injury. 2011;42(2):140–5.CrossRef Su Y, Chen W, Zhang Q, Li B, Li Z, Guo M, Pan J, Zhang Y. An irreducible variant of femoral neck fracture: a minimally traumatic reduction technique. Injury. 2011;42(2):140–5.CrossRef
25.
go back to reference Van Walsum ADP, Vroemen J, Janzing HMJ, Winkelhorst T, Kalsbeek J, Roerdink WH. Low failure rate by means of DLBP fixation of undisplaced femoral neck fractures. Eur J Trauma Emerg Surg. 2017;43(4):475–80.CrossRef Van Walsum ADP, Vroemen J, Janzing HMJ, Winkelhorst T, Kalsbeek J, Roerdink WH. Low failure rate by means of DLBP fixation of undisplaced femoral neck fractures. Eur J Trauma Emerg Surg. 2017;43(4):475–80.CrossRef
26.
go back to reference Sevitt S. Avascular necrosis and revascularisation of the femoral head after intracapsular fractures: a combined arteriographic and histological necropsy study. J Bone Joint Surg Br. 1964;46:270–96.CrossRef Sevitt S. Avascular necrosis and revascularisation of the femoral head after intracapsular fractures: a combined arteriographic and histological necropsy study. J Bone Joint Surg Br. 1964;46:270–96.CrossRef
27.
go back to reference Dargan DP, Callachand F, Diamond OJ, Connolly CK. Three-year outcomes of intracapsular femoral neck fractures fixed with sliding hip screws in adults aged under sixty-five years. Injury. 2016;47(11):2495–500.CrossRef Dargan DP, Callachand F, Diamond OJ, Connolly CK. Three-year outcomes of intracapsular femoral neck fractures fixed with sliding hip screws in adults aged under sixty-five years. Injury. 2016;47(11):2495–500.CrossRef
28.
go back to reference Roerdink WH, Aalsma AM, Nijenbanning G, van Walsum AD. Initial promising results of the dynamic locking blade plate, a new implant for the fixation of intracapsular hip fractures: results of a pilot study. Arch Orthop Trauma Surg. 2011;131(4):519–24.CrossRef Roerdink WH, Aalsma AM, Nijenbanning G, van Walsum AD. Initial promising results of the dynamic locking blade plate, a new implant for the fixation of intracapsular hip fractures: results of a pilot study. Arch Orthop Trauma Surg. 2011;131(4):519–24.CrossRef
29.
go back to reference Stromqvist B, Hansson LI, Palmer J, Ceder L, Thorngren KG. Scintimetric evaluation of nailed femoral neck fractures with special reference to type of osteosynthesis. Acta Orthop Scand. 1983;54(3):340–7.CrossRef Stromqvist B, Hansson LI, Palmer J, Ceder L, Thorngren KG. Scintimetric evaluation of nailed femoral neck fractures with special reference to type of osteosynthesis. Acta Orthop Scand. 1983;54(3):340–7.CrossRef
30.
go back to reference Linde F, Andersen E, Hvass I, Madsen F, Pallesen R. Avascular femoral head necrosis following fracture fixation. Injury. 1986;17(3):159–63.CrossRef Linde F, Andersen E, Hvass I, Madsen F, Pallesen R. Avascular femoral head necrosis following fracture fixation. Injury. 1986;17(3):159–63.CrossRef
Metadata
Title
Anteromedial femoral neck plate with cannulated screws for the treatment of irreducible displaced femoral neck fracture in young patients: a preliminary study
Authors
Linbo Zhuang
Lisheng Wang
Dongming Xu
Zhiyong Wang
Publication date
01-12-2019
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Trauma and Emergency Surgery / Issue 6/2019
Print ISSN: 1863-9933
Electronic ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-018-0972-1

Other articles of this Issue 6/2019

European Journal of Trauma and Emergency Surgery 6/2019 Go to the issue