Skip to main content
Top
Published in: CardioVascular and Interventional Radiology 7/2019

01-07-2019 | Aneurysm | Review

Current Status of Endovascular Preservation of the Internal Iliac Artery with Iliac Branch Devices (IBD)

Authors: Mario D’Oria, Davide Mastrorilli, Randall DeMartino, Sandro Lepidi

Published in: CardioVascular and Interventional Radiology | Issue 7/2019

Login to get access

Abstract

Endovascular aneurysm repair (EVAR) has become the most utilized treatment for abdominal aortic aneurysms (AAA), but the presence of common iliac dilatation or aneurysm may prevent the achievement of effective distal seal and fixation. Ideal repair in these cases should involve both effective preservation of the pelvic circulation and durable exclusion of the AAA. Unilateral or bilateral internal iliac artery (IIA) preservation with iliac branch devices (IBD) is safe, feasible and effective with technical and clinical outcomes comparable to standard EVAR. The versatility of current devices has allowed extended application to complex cases, but must be considered carefully in difficult anatomies. Pending long-term durability results and formal cost-effectiveness appraisals, IBD implantation has several advantages to anatomically eligible patients as compared with other available open or endovascular/hybrid solutions for IIA preservation during EVAR for aortoiliac aneurysms.
Literature
1.
go back to reference Schanzer A, Greenberg RK, Hevelone N, Robinson WP, Eslami MH, Goldberg RJ, et al. Predictors of abdominal aortic aneurysm sac enlargement after endovascular repair. Circulation. 2011;123(24):2848–55.CrossRefPubMed Schanzer A, Greenberg RK, Hevelone N, Robinson WP, Eslami MH, Goldberg RJ, et al. Predictors of abdominal aortic aneurysm sac enlargement after endovascular repair. Circulation. 2011;123(24):2848–55.CrossRefPubMed
2.
go back to reference Kaladji A, Daoudal A, Dumenil A, Goksu C, Cardon A, Clochard E, et al. Predictive models of complications after endovascular aortic aneurysm repair. Ann Vasc Surg. 2017;40:19–27.CrossRefPubMed Kaladji A, Daoudal A, Dumenil A, Goksu C, Cardon A, Clochard E, et al. Predictive models of complications after endovascular aortic aneurysm repair. Ann Vasc Surg. 2017;40:19–27.CrossRefPubMed
3.
go back to reference Bosanquet DC, Wilcox C, Whitehurst L, et al. Systematic review and meta-analysis of the effect of internal iliac artery occlusion for patients undergoing EVAR. Eur J Vasc Endovasc Surg. 2017;53:534–48.CrossRefPubMed Bosanquet DC, Wilcox C, Whitehurst L, et al. Systematic review and meta-analysis of the effect of internal iliac artery occlusion for patients undergoing EVAR. Eur J Vasc Endovasc Surg. 2017;53:534–48.CrossRefPubMed
4.
go back to reference Chun JY, Mailli L, Abbasi MA, et al. Embolization of the internal iliac artery before EVAR: Is it effective? Is it safe? Which technique should be used? Cardiovasc Intervent Radiol. 2014;37:329–36.CrossRefPubMed Chun JY, Mailli L, Abbasi MA, et al. Embolization of the internal iliac artery before EVAR: Is it effective? Is it safe? Which technique should be used? Cardiovasc Intervent Radiol. 2014;37:329–36.CrossRefPubMed
5.
go back to reference Rayt HS, Bown MJ, Lambert KV, et al. Buttock claudication and erectile disfunction after internal iliac artery embolization in patients prior to endovascular aortic aneurysm repair. Cardiovasc Intervent Radiol. 2008;31:728–34.CrossRefPubMed Rayt HS, Bown MJ, Lambert KV, et al. Buttock claudication and erectile disfunction after internal iliac artery embolization in patients prior to endovascular aortic aneurysm repair. Cardiovasc Intervent Radiol. 2008;31:728–34.CrossRefPubMed
6.
go back to reference Chaikof E, Dalman RL, Eskandari M, et al. The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg. 2018;67:2–77.CrossRefPubMed Chaikof E, Dalman RL, Eskandari M, et al. The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg. 2018;67:2–77.CrossRefPubMed
7.
go back to reference Wanhainen A, Verzini F, Van Herzeele I, et al. European Society for Vascular Surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms. Eur J Vasc Endovasc Surg. 2019 (Epub ahead of print). Wanhainen A, Verzini F, Van Herzeele I, et al. European Society for Vascular Surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms. Eur J Vasc Endovasc Surg. 2019 (Epub ahead of print).
8.
go back to reference Kouvelos GN, Katsargyris A, Antoniou GA, et al. Outcome after interruption or preservation of internal iliac artery flow during endovascular repair of abdominal aorto-iliac aneurysms. Eur J Vasc Endovasc Surg. 2016;52:621–34.CrossRefPubMed Kouvelos GN, Katsargyris A, Antoniou GA, et al. Outcome after interruption or preservation of internal iliac artery flow during endovascular repair of abdominal aorto-iliac aneurysms. Eur J Vasc Endovasc Surg. 2016;52:621–34.CrossRefPubMed
9.
go back to reference Bratby MJ, Munneke GM, Belli AM, et al. How safe is bilateral internal iliac artery embolization prior to EVAR? Cardiovasc Intervent Radiol. 2008;31:246–53.CrossRefPubMed Bratby MJ, Munneke GM, Belli AM, et al. How safe is bilateral internal iliac artery embolization prior to EVAR? Cardiovasc Intervent Radiol. 2008;31:246–53.CrossRefPubMed
10.
go back to reference Bisdas T, Panuccio G, Sugimoto M, et al. Risk factors for spinal cord ischemia after endovascular repair of thoracoabdominal aortic aneurysms. J Vasc Surg. 2015;61:1408–16.CrossRefPubMed Bisdas T, Panuccio G, Sugimoto M, et al. Risk factors for spinal cord ischemia after endovascular repair of thoracoabdominal aortic aneurysms. J Vasc Surg. 2015;61:1408–16.CrossRefPubMed
11.
go back to reference Eagleton MJ, Shah S, Petkosevek D, et al. Hypogastric and subclavian artery patency affects onset and recovery of spinal cord ischemia associated with aortic endografting. J Vasc Surg. 2014;59:89–95.CrossRefPubMed Eagleton MJ, Shah S, Petkosevek D, et al. Hypogastric and subclavian artery patency affects onset and recovery of spinal cord ischemia associated with aortic endografting. J Vasc Surg. 2014;59:89–95.CrossRefPubMed
12.
go back to reference Maurel B, Delclaux N, Sobocinski J, et al. Editor’s choice. The impact of early pelvic and lower limb reperfusion and attentive peri-operative management on the incidence of spinal cord ischemia during thoracoabdominal aortic aneurysm endovascular repair. Eur J Vasc Endovasc Surg. 2015;49:248–54.CrossRefPubMed Maurel B, Delclaux N, Sobocinski J, et al. Editor’s choice. The impact of early pelvic and lower limb reperfusion and attentive peri-operative management on the incidence of spinal cord ischemia during thoracoabdominal aortic aneurysm endovascular repair. Eur J Vasc Endovasc Surg. 2015;49:248–54.CrossRefPubMed
13.
go back to reference Dijkstra ML, Vainas T, Zeebregts CJ, et al. Editor’s choice. Spinal cord ischemia in endovascular thoracic and thoracoabdominal aortic repair: review of preventive strategies. Eur J Vasc Endovasc Surg. 2018;55:829–41.CrossRefPubMed Dijkstra ML, Vainas T, Zeebregts CJ, et al. Editor’s choice. Spinal cord ischemia in endovascular thoracic and thoracoabdominal aortic repair: review of preventive strategies. Eur J Vasc Endovasc Surg. 2018;55:829–41.CrossRefPubMed
14.
go back to reference Tenorio E, Eagleton MJ, Karkkainen J, et al. Prevention of spinal cord injury during endovascular thoracoabdominal repair. J Cardiovasc Surg. 2019 (Epub ahead of print). Tenorio E, Eagleton MJ, Karkkainen J, et al. Prevention of spinal cord injury during endovascular thoracoabdominal repair. J Cardiovasc Surg. 2019 (Epub ahead of print).
15.
go back to reference Bisdas T, Weiss K, Donas KP, et al. Use of iliac branch devices for endovascular repair of aneurysmal distal seal zones after EVAR. J Endovasc Ther. 2014;21:579–86.CrossRefPubMed Bisdas T, Weiss K, Donas KP, et al. Use of iliac branch devices for endovascular repair of aneurysmal distal seal zones after EVAR. J Endovasc Ther. 2014;21:579–86.CrossRefPubMed
16.
go back to reference Tenorio E, Oderich GS, Sandri GA, et al. Outcomes of an iliac branch endoprosthesis using an up-and-over technique for endovascular repair of failed bifurcated grafts. J Vasc Surg. 2018 (Epub ahead of print). Tenorio E, Oderich GS, Sandri GA, et al. Outcomes of an iliac branch endoprosthesis using an up-and-over technique for endovascular repair of failed bifurcated grafts. J Vasc Surg. 2018 (Epub ahead of print).
17.
go back to reference Fatima J, Oderich GS. Iliac branch device designs. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 38. Springer International Publishing AG; 2017. p. 579–582. Fatima J, Oderich GS. Iliac branch device designs. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 38. Springer International Publishing AG; 2017. p. 579–582.
18.
go back to reference Della Schiava N, Arsicot M, Boudjelit T, et al. Conformability of GORE excluder iliac branch endoprosthesis and COOK zenith bifurcated iliac side branched iliac stent grafts. Ann Vasc Surg. 2016;36:139–44.CrossRefPubMed Della Schiava N, Arsicot M, Boudjelit T, et al. Conformability of GORE excluder iliac branch endoprosthesis and COOK zenith bifurcated iliac side branched iliac stent grafts. Ann Vasc Surg. 2016;36:139–44.CrossRefPubMed
19.
go back to reference Fatima J, Oderich GS. Preoperative planning and sizing for iliac branch devices. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 39. Springer International Publishing AG; 2017. p. 583–593. Fatima J, Oderich GS. Preoperative planning and sizing for iliac branch devices. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 39. Springer International Publishing AG; 2017. p. 583–593.
20.
go back to reference Bellandi G, Ventoruzzo G. Endovascular bilateral evolutive common iliac artery aneurysm repair using a Zenith branch graft through a combined femoro-brachial approach in a patient with previous EVAR. Eur J Vasc Endovasc Surg. 2010;40:596–8.CrossRefPubMed Bellandi G, Ventoruzzo G. Endovascular bilateral evolutive common iliac artery aneurysm repair using a Zenith branch graft through a combined femoro-brachial approach in a patient with previous EVAR. Eur J Vasc Endovasc Surg. 2010;40:596–8.CrossRefPubMed
21.
go back to reference D’Oria M, Chiarandini S, Pipitone M, et al. Urgent use of Gore Excluder Iliac Branch Endoprosthesis with left transaxillary approach for preservation of the residual hypogastric artery: a case series. Ann Vasc Surg. 2018;51:326.e17–21.CrossRef D’Oria M, Chiarandini S, Pipitone M, et al. Urgent use of Gore Excluder Iliac Branch Endoprosthesis with left transaxillary approach for preservation of the residual hypogastric artery: a case series. Ann Vasc Surg. 2018;51:326.e17–21.CrossRef
22.
go back to reference Ferrer C, Venturini L, Grande G, et al. A steerable sheath to deploy hypogastric bridging stent by contralateral femoral approach in an iliac branch procedure after endovascular aneurysm repair. Ann Vasc Surg. 2017;44:415.e1–5.CrossRef Ferrer C, Venturini L, Grande G, et al. A steerable sheath to deploy hypogastric bridging stent by contralateral femoral approach in an iliac branch procedure after endovascular aneurysm repair. Ann Vasc Surg. 2017;44:415.e1–5.CrossRef
23.
go back to reference Oberhuber A, Duran M, Ertas N, et al. Implantation of an iliac branch device after EVAR via a femoral approach using a steerable sheath. J Endovasc Ther. 2015;22:610–2.CrossRefPubMed Oberhuber A, Duran M, Ertas N, et al. Implantation of an iliac branch device after EVAR via a femoral approach using a steerable sheath. J Endovasc Ther. 2015;22:610–2.CrossRefPubMed
24.
go back to reference Dawson DL, Sandri GA, Tenorio ER, et al. Up-and-over technique for implantation of iliac branch devices after prior aortic endograft repair. J Endovasc Ther. 2018;25:21–7.CrossRefPubMed Dawson DL, Sandri GA, Tenorio ER, et al. Up-and-over technique for implantation of iliac branch devices after prior aortic endograft repair. J Endovasc Ther. 2018;25:21–7.CrossRefPubMed
25.
go back to reference Mantas GK, Antonopoulos CN, Sfyroeras GS, et al. Factors predisposing to endograft limb occlusion after endovascular aortic repair. Eur J Vasc Endovasc Surg. 2015;49:39–44.CrossRefPubMed Mantas GK, Antonopoulos CN, Sfyroeras GS, et al. Factors predisposing to endograft limb occlusion after endovascular aortic repair. Eur J Vasc Endovasc Surg. 2015;49:39–44.CrossRefPubMed
26.
go back to reference Moulakakis KG, Antonopoulos CN, Klonaris C, et al. Bilateral endograft limb occlusion after endovascular aortic repair: predictive factors of occurrence. Ann Vasc Surg. 2018;46:299–306.CrossRefPubMed Moulakakis KG, Antonopoulos CN, Klonaris C, et al. Bilateral endograft limb occlusion after endovascular aortic repair: predictive factors of occurrence. Ann Vasc Surg. 2018;46:299–306.CrossRefPubMed
27.
go back to reference Taudorf M, Jensen LP, Vogt KC, Gronvall J, Schroeder TV, Lonn L. Endograft limb occlusion in EVAR: iliac tortuosity quantified by three different indices on the basis of preoperative CTA. Eur J Vasc Endovasc Surg. 2014;48:527–33.CrossRefPubMed Taudorf M, Jensen LP, Vogt KC, Gronvall J, Schroeder TV, Lonn L. Endograft limb occlusion in EVAR: iliac tortuosity quantified by three different indices on the basis of preoperative CTA. Eur J Vasc Endovasc Surg. 2014;48:527–33.CrossRefPubMed
28.
go back to reference Maleux G, Koolen M, Heye S, et al. Limb occlusion after endovascular repair of abdominal aortic aneurysms with supported endografts. J Vasc Interv Radiol. 2008;19:1409–12.CrossRefPubMed Maleux G, Koolen M, Heye S, et al. Limb occlusion after endovascular repair of abdominal aortic aneurysms with supported endografts. J Vasc Interv Radiol. 2008;19:1409–12.CrossRefPubMed
29.
go back to reference Conway AM, Modarai B, Taylor PR, et al. Stent-graft limb deployment in the external iliac artery increases the risk of limb occlusion following endovascular AAA repair. J Endovasc Ther. 2012;19:79–85.CrossRefPubMed Conway AM, Modarai B, Taylor PR, et al. Stent-graft limb deployment in the external iliac artery increases the risk of limb occlusion following endovascular AAA repair. J Endovasc Ther. 2012;19:79–85.CrossRefPubMed
30.
go back to reference Cochennec F, Becquemin JP, Desgranges P, Allaire E, Kobeiter H, Roudot-Thoraval F. Limb graft occlusion following EVAR: clinical pattern, outcomes and predictive factors of occurrence. Eur J Vasc Endovasc Surg. 2007;34:59–65.CrossRefPubMed Cochennec F, Becquemin JP, Desgranges P, Allaire E, Kobeiter H, Roudot-Thoraval F. Limb graft occlusion following EVAR: clinical pattern, outcomes and predictive factors of occurrence. Eur J Vasc Endovasc Surg. 2007;34:59–65.CrossRefPubMed
31.
go back to reference Faure EM, Becquemin JP, Cochennec F, et al. Predictive factors for limb occlusions after endovascular aneurysm repair. J Vasc Surg. 2015;61:1138–45.CrossRefPubMed Faure EM, Becquemin JP, Cochennec F, et al. Predictive factors for limb occlusions after endovascular aneurysm repair. J Vasc Surg. 2015;61:1138–45.CrossRefPubMed
32.
go back to reference Hammond A, Hansrani V, Lowe C, et al. Meta-analysis and meta-regression of iliac limb occlusion after endovascular aneurysm repair. J Vasc Surg. 2018;68:1916–24.CrossRefPubMed Hammond A, Hansrani V, Lowe C, et al. Meta-analysis and meta-regression of iliac limb occlusion after endovascular aneurysm repair. J Vasc Surg. 2018;68:1916–24.CrossRefPubMed
33.
go back to reference Tenorio ER, Oderich GS, Sandri GA, et al. Impact of onlay fusion and cone beam computed tomography on radiation exposure and technical assessment of fenestrated-branched endovascular aortic repair. J Vasc Surg. 2018 (Epub ahead of print). Tenorio ER, Oderich GS, Sandri GA, et al. Impact of onlay fusion and cone beam computed tomography on radiation exposure and technical assessment of fenestrated-branched endovascular aortic repair. J Vasc Surg. 2018 (Epub ahead of print).
34.
go back to reference Hertault A, Maurel B, Sobocinski J, et al. Impact of hybrid rooms with image fusion on radiation exposure during endovascular aortic repair. Eur J Vasc Endovasc Surg. 2014;48:382–90.CrossRefPubMed Hertault A, Maurel B, Sobocinski J, et al. Impact of hybrid rooms with image fusion on radiation exposure during endovascular aortic repair. Eur J Vasc Endovasc Surg. 2014;48:382–90.CrossRefPubMed
35.
go back to reference McNally MM, Scali ST, Feezor RJ, et al. Three dimensional fusion CT decreases radiation exposure, procedure time and contrast use during fenestrated endovascular aortic repair. J Vasc Surg. 2015;61:309–16.CrossRefPubMed McNally MM, Scali ST, Feezor RJ, et al. Three dimensional fusion CT decreases radiation exposure, procedure time and contrast use during fenestrated endovascular aortic repair. J Vasc Surg. 2015;61:309–16.CrossRefPubMed
36.
go back to reference Hertault A, Rhee R, Antoniou GA, et al. Radiation dose reduction during EVAR: results from a prospective multicenter study (The REVAR Study). Eur J Vasc Endovasc Surg. 2018;56:426–33.CrossRefPubMed Hertault A, Rhee R, Antoniou GA, et al. Radiation dose reduction during EVAR: results from a prospective multicenter study (The REVAR Study). Eur J Vasc Endovasc Surg. 2018;56:426–33.CrossRefPubMed
37.
go back to reference Vento V, Gavit L, Soler R, et al. Optimizing imaging and reducing radiation exposure during complex aortic endovascular procedures. J Cardiovasc Surg. 2018 (Epub ahead of print). Vento V, Gavit L, Soler R, et al. Optimizing imaging and reducing radiation exposure during complex aortic endovascular procedures. J Cardiovasc Surg. 2018 (Epub ahead of print).
38.
go back to reference Donas KP, Bisdas T, Torsello G, et al. Technical considerations and performance of bridging stent-grafts for iliac side branches devices based on a pooled analysis of single-center experiences. J Endovasc Ther. 2012;19:667–71.CrossRefPubMed Donas KP, Bisdas T, Torsello G, et al. Technical considerations and performance of bridging stent-grafts for iliac side branches devices based on a pooled analysis of single-center experiences. J Endovasc Ther. 2012;19:667–71.CrossRefPubMed
39.
go back to reference Sharafuddin MJ, Hoballa JJ, Kresowik TF, et al. Long-term outcome following stent reconstruction of the aortic bifurcation and the role of geometric determinants. Ann Vasc Surg. 2008;22:346–57.CrossRefPubMed Sharafuddin MJ, Hoballa JJ, Kresowik TF, et al. Long-term outcome following stent reconstruction of the aortic bifurcation and the role of geometric determinants. Ann Vasc Surg. 2008;22:346–57.CrossRefPubMed
40.
go back to reference Malkawi AH, Hinchliffe RJ, Holt PJ, et al. Percutaneous access for endovascular aneurysm repair: a systematic review. Eur J Vasc Endovasc Surg. 2010;39:676–82.CrossRefPubMed Malkawi AH, Hinchliffe RJ, Holt PJ, et al. Percutaneous access for endovascular aneurysm repair: a systematic review. Eur J Vasc Endovasc Surg. 2010;39:676–82.CrossRefPubMed
41.
go back to reference Nelson PR, Kracjer Z, Kansal N, et al. A multicenter, randomized, controlled trial of totally percutaneous access versus open femoral exposure for endovascular aneurysm repair (the PEVAR trial). J Vasc Surg. 2014;59:1181–93.CrossRefPubMed Nelson PR, Kracjer Z, Kansal N, et al. A multicenter, randomized, controlled trial of totally percutaneous access versus open femoral exposure for endovascular aneurysm repair (the PEVAR trial). J Vasc Surg. 2014;59:1181–93.CrossRefPubMed
42.
go back to reference Hajibandeh S, Hajibandeh S, Antoniouo SA, et al. Percutaneous access for endovascular aortic aneurysm repair: a systematic review and meta-analysis. Vascular. 2016;24:638–48.CrossRefPubMed Hajibandeh S, Hajibandeh S, Antoniouo SA, et al. Percutaneous access for endovascular aortic aneurysm repair: a systematic review and meta-analysis. Vascular. 2016;24:638–48.CrossRefPubMed
43.
44.
go back to reference Dwivedi K, Regi JM, Cleveland TJ, et al. Long-term evaluation of percutaneous groin access for EVAR. Cardiovasc Intervent Radiol. 2019;42:28–33.CrossRefPubMed Dwivedi K, Regi JM, Cleveland TJ, et al. Long-term evaluation of percutaneous groin access for EVAR. Cardiovasc Intervent Radiol. 2019;42:28–33.CrossRefPubMed
45.
go back to reference Eisenack M, Umscheid T, Tessarek J, et al. Percutaneous endovascular aortic aneurysm repair: a prospective evaluation of safety, efficiency, and risk factors. J Endovasc Ther. 2009;16:708–13.CrossRefPubMed Eisenack M, Umscheid T, Tessarek J, et al. Percutaneous endovascular aortic aneurysm repair: a prospective evaluation of safety, efficiency, and risk factors. J Endovasc Ther. 2009;16:708–13.CrossRefPubMed
46.
go back to reference Mousa AY, Campbell JE, Broce M, et al. Predictors of percutaneous access failure requiring open femoral surgical conversion during endovascular aortic aneurysm repair. J Vasc Surg. 2013;58:1213–9.CrossRefPubMed Mousa AY, Campbell JE, Broce M, et al. Predictors of percutaneous access failure requiring open femoral surgical conversion during endovascular aortic aneurysm repair. J Vasc Surg. 2013;58:1213–9.CrossRefPubMed
47.
go back to reference Haulon S, Greenberg RK, Pfaff K, et al. Branched grafting for aortoiliac aneurysms. Eur J Vasc Endovasc Surg. 2007;33:567–74.CrossRefPubMed Haulon S, Greenberg RK, Pfaff K, et al. Branched grafting for aortoiliac aneurysms. Eur J Vasc Endovasc Surg. 2007;33:567–74.CrossRefPubMed
48.
go back to reference Karthikesalingam A, Hinchliffe RJ, Holt PJ, et al. Endovascular aneurysm repair with preservation of the internal iliac artery using the iliac branch graft device. Eur J Vasc Endovasc Surg. 2010;39:285–94.CrossRefPubMed Karthikesalingam A, Hinchliffe RJ, Holt PJ, et al. Endovascular aneurysm repair with preservation of the internal iliac artery using the iliac branch graft device. Eur J Vasc Endovasc Surg. 2010;39:285–94.CrossRefPubMed
49.
go back to reference van Sterkenburg SMM, Heyligers JMM, van Bladel M, et al; for the Dutch IBE Collaboration. Experience with the GORE EXCLUDER iliac branch endoprosthesis for common iliac artery aneurysms. J Vasc Surg. 2016;63:1451–1457. van Sterkenburg SMM, Heyligers JMM, van Bladel M, et al; for the Dutch IBE Collaboration. Experience with the GORE EXCLUDER iliac branch endoprosthesis for common iliac artery aneurysms. J Vasc Surg. 2016;63:1451–1457.
50.
go back to reference Verzini F, Parlani G, De Rango P, et al. Results of iliac branch stent-grafts. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 41. Springer International Publishing AG; 2017. p. 623–640. Verzini F, Parlani G, De Rango P, et al. Results of iliac branch stent-grafts. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 41. Springer International Publishing AG; 2017. p. 623–640.
51.
go back to reference Donas KP, Torsello G, Pitoulias G, et al. Surgical versus endovascular repair by iliac branch device of aneurysms involving the iliac bifurcation. J Vasc Surg. 2011;53:1223–9.CrossRefPubMed Donas KP, Torsello G, Pitoulias G, et al. Surgical versus endovascular repair by iliac branch device of aneurysms involving the iliac bifurcation. J Vasc Surg. 2011;53:1223–9.CrossRefPubMed
52.
go back to reference Mylonas SN, Rumenapf G, Schelzig H, et al. A multicenter 12-month experience with a new iliac side-branched device for revascularization of hypogastric arteries. J Vasc Surg. 2016;64:1652–9.CrossRefPubMed Mylonas SN, Rumenapf G, Schelzig H, et al. A multicenter 12-month experience with a new iliac side-branched device for revascularization of hypogastric arteries. J Vasc Surg. 2016;64:1652–9.CrossRefPubMed
53.
go back to reference Cochennec F, Marzelle J, Allaire E, et al. Open versus endovascular repair of abdominal aortic aneurysm involving the iliac bifurcation. J Vasc Surg. 2010;51:1360–6.CrossRefPubMed Cochennec F, Marzelle J, Allaire E, et al. Open versus endovascular repair of abdominal aortic aneurysm involving the iliac bifurcation. J Vasc Surg. 2010;51:1360–6.CrossRefPubMed
54.
go back to reference Verzini F, Parlani G, Romano L, et al. Endovascular treatment of iliac aneurysm: concurrent comparison of side branched endograft versus hypogastric exclusion. J Vasc Surg. 2009;49:1154–61.CrossRefPubMed Verzini F, Parlani G, Romano L, et al. Endovascular treatment of iliac aneurysm: concurrent comparison of side branched endograft versus hypogastric exclusion. J Vasc Surg. 2009;49:1154–61.CrossRefPubMed
55.
go back to reference Pratesi G, Fargion A, Pulli R, et al. Endovascular treatment of aorto-iliac aneurysms: four-year results of iliac branch endograft. Eur J Vasc Endovasc Surg. 2013 45(6):607–9.CrossRefPubMed Pratesi G, Fargion A, Pulli R, et al. Endovascular treatment of aorto-iliac aneurysms: four-year results of iliac branch endograft. Eur J Vasc Endovasc Surg. 2013 45(6):607–9.CrossRefPubMed
56.
go back to reference Farivar BS, Abbasi MN, Dias AP, et al. Durability of iliac artery preservation associated with endovascular repair of infrarenal aortoiliac aneurysms. J Vasc Surg. 2017;66:1028–36.CrossRefPubMed Farivar BS, Abbasi MN, Dias AP, et al. Durability of iliac artery preservation associated with endovascular repair of infrarenal aortoiliac aneurysms. J Vasc Surg. 2017;66:1028–36.CrossRefPubMed
57.
go back to reference Li Y, Hu Z, Zhang J, et al. Iliac aneurysms treated with endovascular iliac branch device: a systematic review and meta-analysis. Ann Vasc Surg. 2018 (Epub ahead of print). Li Y, Hu Z, Zhang J, et al. Iliac aneurysms treated with endovascular iliac branch device: a systematic review and meta-analysis. Ann Vasc Surg. 2018 (Epub ahead of print).
58.
go back to reference Simonte G, Parlani G, Farchioni L, et al. Lesson learned with the use of iliac branch devices: single centre 10 year experience in 157 consecutive patients. Eur J Vasc Endovasc Surg. 2017;54:95–103.CrossRefPubMed Simonte G, Parlani G, Farchioni L, et al. Lesson learned with the use of iliac branch devices: single centre 10 year experience in 157 consecutive patients. Eur J Vasc Endovasc Surg. 2017;54:95–103.CrossRefPubMed
59.
go back to reference Schneider DB, Matsumura JS, Lee JT, et al. Prospective, multicenter study of endovascular repair of aortoiliac and iliac aneurysms using the Gore Iliac Branch Endoprosthesis. J Vasc Surg. 2017;66:775–85.CrossRefPubMed Schneider DB, Matsumura JS, Lee JT, et al. Prospective, multicenter study of endovascular repair of aortoiliac and iliac aneurysms using the Gore Iliac Branch Endoprosthesis. J Vasc Surg. 2017;66:775–85.CrossRefPubMed
60.
go back to reference Jongsma H, Bekken JA, Bekkers WJ, et al. Endovascular treatment of common iliac artery aneurysms with an iliac branch device: multicenter experience of 140 patients. J Endovasc Ther. 2017;24:239–45.CrossRefPubMed Jongsma H, Bekken JA, Bekkers WJ, et al. Endovascular treatment of common iliac artery aneurysms with an iliac branch device: multicenter experience of 140 patients. J Endovasc Ther. 2017;24:239–45.CrossRefPubMed
61.
go back to reference Delay C, Deglise S, Lejay A, et al. Zenith bifurcated iliac side branch device: midterm results and assessment of risk factors for intraoperative thrombosis. Ann Vasc Surg. 2017;41:141–50.CrossRefPubMed Delay C, Deglise S, Lejay A, et al. Zenith bifurcated iliac side branch device: midterm results and assessment of risk factors for intraoperative thrombosis. Ann Vasc Surg. 2017;41:141–50.CrossRefPubMed
62.
go back to reference Donas KP, Inchingolo M, Cao P, et al. Secondary procedures following iliac branch device treatment of aneurysms involving the iliac bifurcation: the pELVIS Registry. J Endovasc Ther. 2017;24:405–10.CrossRefPubMed Donas KP, Inchingolo M, Cao P, et al. Secondary procedures following iliac branch device treatment of aneurysms involving the iliac bifurcation: the pELVIS Registry. J Endovasc Ther. 2017;24:405–10.CrossRefPubMed
63.
go back to reference de Marino PM, Botos B, Kouvelos G, et al. Use of bilateral cook Zenith Iliac Branch Devices to preserve internal iliac artery flow during endovascular aneurysm repair. Eur J Vasc Endovasc Surg. 2018 (Epub ahead of print). de Marino PM, Botos B, Kouvelos G, et al. Use of bilateral cook Zenith Iliac Branch Devices to preserve internal iliac artery flow during endovascular aneurysm repair. Eur J Vasc Endovasc Surg. 2018 (Epub ahead of print).
64.
go back to reference Maldonado TS, Mosquera NJ, Lin P, et al; on behalf of the Gore Bilateral IBE Study Group. Gore Iliac Branch Endoprosthesis for treatment of bilateral common iliac artery aneurysms. J Vasc Surg. 2018;68:100–108. Maldonado TS, Mosquera NJ, Lin P, et al; on behalf of the Gore Bilateral IBE Study Group. Gore Iliac Branch Endoprosthesis for treatment of bilateral common iliac artery aneurysms. J Vasc Surg. 2018;68:100–108.
65.
go back to reference Wong S, Greenberg RK, Brown CR, et al. Endovascular repair of aortoiliac aneurysmal disease with the helical iliac bifurcation device and the bifurcated-bifurcated iliac bifurcation device. J Vasc Surg. 2013;58:861–9.CrossRefPubMed Wong S, Greenberg RK, Brown CR, et al. Endovascular repair of aortoiliac aneurysmal disease with the helical iliac bifurcation device and the bifurcated-bifurcated iliac bifurcation device. J Vasc Surg. 2013;58:861–9.CrossRefPubMed
66.
go back to reference Fatima J, Oderich GS. Techniques of endovascular repair of aorto-iliac aneurysms using iliac branch devices. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 40. Springer International Publishing AG; 2017. p. 595–622. Fatima J, Oderich GS. Techniques of endovascular repair of aorto-iliac aneurysms using iliac branch devices. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 40. Springer International Publishing AG; 2017. p. 595–622.
67.
go back to reference Karthikesalingam A, Hinchliffe RJ, Malkawi AH, et al. Morphological suitability of patients with aortoiliac aneurysms for endovascular preservation of the internal iliac artery using commercially available iliac branch graft devices. J Endovasc Ther. 2010;17:163–71.CrossRefPubMed Karthikesalingam A, Hinchliffe RJ, Malkawi AH, et al. Morphological suitability of patients with aortoiliac aneurysms for endovascular preservation of the internal iliac artery using commercially available iliac branch graft devices. J Endovasc Ther. 2010;17:163–71.CrossRefPubMed
68.
go back to reference Gray D, Shahverdyan R, Jakobs C. Endovascular aneurysm repair of aortoiliac aneurysms with an iliac side-branched stent-graft: studying the morphological applicability of the Cook device. Eur J Vasc Endovasc Surg. 2015;49:283–8.CrossRefPubMed Gray D, Shahverdyan R, Jakobs C. Endovascular aneurysm repair of aortoiliac aneurysms with an iliac side-branched stent-graft: studying the morphological applicability of the Cook device. Eur J Vasc Endovasc Surg. 2015;49:283–8.CrossRefPubMed
69.
go back to reference Pearce BJ, Varu VN, Glocker R, et al. Anatomic suitability of aortoiliac aneurysms for next generation branched systems. Ann Vasc Surg. 2015;29:69–75.CrossRefPubMed Pearce BJ, Varu VN, Glocker R, et al. Anatomic suitability of aortoiliac aneurysms for next generation branched systems. Ann Vasc Surg. 2015;29:69–75.CrossRefPubMed
70.
go back to reference Schneider DB, Milner R, Heyligers JMM, et al. Outcomes of the GORE Iliac Branch Endoprosthesis in clinical trial and real-world registry settings. J Vasc Surg. 2018 (Epub ahead of print). Schneider DB, Milner R, Heyligers JMM, et al. Outcomes of the GORE Iliac Branch Endoprosthesis in clinical trial and real-world registry settings. J Vasc Surg. 2018 (Epub ahead of print).
71.
go back to reference Bosiers MJ, Panuccio G, Bisdas T, et al. Longer bridging stent grafts in iliac branch endografting doesn’t worsen outcome and expand its applicability, even in concomitant diseased hypogastric arteries. J Cardiovasc Surg. 2018 (Epub ahead of print). Bosiers MJ, Panuccio G, Bisdas T, et al. Longer bridging stent grafts in iliac branch endografting doesn’t worsen outcome and expand its applicability, even in concomitant diseased hypogastric arteries. J Cardiovasc Surg. 2018 (Epub ahead of print).
72.
go back to reference D’Oria M, Pipitone M, Sgorlon G. Endovascular exclusion of hypogastric aneurysms using distal branches of the internal iliac artery as landing zone: a case series. Ann Vasc Surg. 2018;46:369.e13–8.CrossRef D’Oria M, Pipitone M, Sgorlon G. Endovascular exclusion of hypogastric aneurysms using distal branches of the internal iliac artery as landing zone: a case series. Ann Vasc Surg. 2018;46:369.e13–8.CrossRef
73.
go back to reference Conway BD, Greenberg RK, Mastracci TM, et al. Renal artery implantation angles in thoracoabdominal aneurysms and their implications in the era of branched endografts. J Endovasc Ther. 2010;17:380–7.CrossRefPubMed Conway BD, Greenberg RK, Mastracci TM, et al. Renal artery implantation angles in thoracoabdominal aneurysms and their implications in the era of branched endografts. J Endovasc Ther. 2010;17:380–7.CrossRefPubMed
74.
go back to reference Sugimoto M, Panuccio G, Bisdas T, et al. Tortuosity is the significant predictive factor for renal branch occlusion after branched endovascular aneurysm repair. Eur J Vasc Endovasc Surg. 2016;51:350–7.CrossRefPubMed Sugimoto M, Panuccio G, Bisdas T, et al. Tortuosity is the significant predictive factor for renal branch occlusion after branched endovascular aneurysm repair. Eur J Vasc Endovasc Surg. 2016;51:350–7.CrossRefPubMed
75.
go back to reference Gallitto E, Faggioli G, Pini R, et al. Renal artery orientation influences the renal outcome in endovascular thoraco-abdominal aneurysm repair. Eur J Vasc Endovasc Surg. 2018;56:382–90.CrossRefPubMed Gallitto E, Faggioli G, Pini R, et al. Renal artery orientation influences the renal outcome in endovascular thoraco-abdominal aneurysm repair. Eur J Vasc Endovasc Surg. 2018;56:382–90.CrossRefPubMed
76.
go back to reference Donas KP, Taneva GT, Pitoulias GA, et al; on behalf of the pELVIS Registry collaborators. Coexisting hypogastric aneurysms worsen the outcomes of endovascular treatment by the iliac branch devices within the pELVIS Registry. J Vasc Surg. 2018 (Epub ahead of print). Donas KP, Taneva GT, Pitoulias GA, et al; on behalf of the pELVIS Registry collaborators. Coexisting hypogastric aneurysms worsen the outcomes of endovascular treatment by the iliac branch devices within the pELVIS Registry. J Vasc Surg. 2018 (Epub ahead of print).
77.
go back to reference Giaquinta A, Ardita V, Ferrer C, et al; on behalf of the Iliac Branch Stent-Graft Italian Trial Collaborators. Isolated common iliac artery aneurysms treated solely with iliac branch stent-grafts: midterm results of a multicenter registry. J Endovasc Ther. 2018;25:169–177. Giaquinta A, Ardita V, Ferrer C, et al; on behalf of the Iliac Branch Stent-Graft Italian Trial Collaborators. Isolated common iliac artery aneurysms treated solely with iliac branch stent-grafts: midterm results of a multicenter registry. J Endovasc Ther. 2018;25:169–177.
78.
go back to reference Fargion AT, Masciello F, Pratesi C, et al. Results of the multicenter pELVIS Registry for isolated common iliac aneurysms treated by the iliac branch device. J Vasc Surg. 2018;68:1367–73.CrossRefPubMed Fargion AT, Masciello F, Pratesi C, et al. Results of the multicenter pELVIS Registry for isolated common iliac aneurysms treated by the iliac branch device. J Vasc Surg. 2018;68:1367–73.CrossRefPubMed
79.
go back to reference Antoniou GA, Georgiadis GS, Antoniou SA, et al. A meta-analysis of outcomes of endovascular abdominal aortic aneurysm repair in patients with hostile and friendly neck anatomy. J Vasc Surg. 2013;57:527–38.CrossRefPubMed Antoniou GA, Georgiadis GS, Antoniou SA, et al. A meta-analysis of outcomes of endovascular abdominal aortic aneurysm repair in patients with hostile and friendly neck anatomy. J Vasc Surg. 2013;57:527–38.CrossRefPubMed
80.
go back to reference Stather PW, Wild JB, Sayers RD, et al. Endovascular aortic aneurysm repair in patients with hostile neck anatomy. J Endovasc Ther. 2013;20:623–37.CrossRefPubMed Stather PW, Wild JB, Sayers RD, et al. Endovascular aortic aneurysm repair in patients with hostile neck anatomy. J Endovasc Ther. 2013;20:623–37.CrossRefPubMed
81.
go back to reference Speziale F, Sirignano P, Setacci F, et al. Immediate and two-year outcomes after EVAR in “on-label” and “off-label”neck anatomies using different commercially available devices. Analysis of the experience of two Italian vascular centers. Ann Vasc Surg. 2014;28:1892–900.CrossRefPubMed Speziale F, Sirignano P, Setacci F, et al. Immediate and two-year outcomes after EVAR in “on-label” and “off-label”neck anatomies using different commercially available devices. Analysis of the experience of two Italian vascular centers. Ann Vasc Surg. 2014;28:1892–900.CrossRefPubMed
82.
go back to reference Jordan WD, Ouriel K, Mehta M, et al. Outcome based anatomic criteria for defining the hostile aortic neck. J Vasc Surg. 2015;61:1383–90.CrossRefPubMed Jordan WD, Ouriel K, Mehta M, et al. Outcome based anatomic criteria for defining the hostile aortic neck. J Vasc Surg. 2015;61:1383–90.CrossRefPubMed
83.
go back to reference AbuRahma AF, Yacoub M, Mousa AY, et al. Aortic neck anatomic features and predictors of outcomes in endovascular repair of abdominal aortic aneurysms following vs not following instructions for use. J Am Coll Surg. 2016;222:579–89.CrossRefPubMedPubMedCentral AbuRahma AF, Yacoub M, Mousa AY, et al. Aortic neck anatomic features and predictors of outcomes in endovascular repair of abdominal aortic aneurysms following vs not following instructions for use. J Am Coll Surg. 2016;222:579–89.CrossRefPubMedPubMedCentral
84.
go back to reference Bryce Y, Kim W, Katzen B, et al. Outcomes over time in patients with hostile neck anatomy undergoing endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol. 2018;29:1011–6.CrossRefPubMed Bryce Y, Kim W, Katzen B, et al. Outcomes over time in patients with hostile neck anatomy undergoing endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol. 2018;29:1011–6.CrossRefPubMed
85.
go back to reference Herman CR, Charbonneau P, Hongku K, et al. Any nonadherence to instructions for use predicts graft-related adverse events in patients undergoing elective endovascular aneurysm repair. J Vasc Surg. 2018;67:126–33.CrossRefPubMed Herman CR, Charbonneau P, Hongku K, et al. Any nonadherence to instructions for use predicts graft-related adverse events in patients undergoing elective endovascular aneurysm repair. J Vasc Surg. 2018;67:126–33.CrossRefPubMed
86.
go back to reference Oliveira NFG, Bastos Goncalves FM, Van Rijn MJ, et al. Standard endovascular aneurysm repair in patients with wide infrarenal aneurysm necks is associated with increased risk of adverse events. J Vasc Surg. 2017;65:1608–16.CrossRefPubMed Oliveira NFG, Bastos Goncalves FM, Van Rijn MJ, et al. Standard endovascular aneurysm repair in patients with wide infrarenal aneurysm necks is associated with increased risk of adverse events. J Vasc Surg. 2017;65:1608–16.CrossRefPubMed
87.
go back to reference Gargiulo M, Gallitto E, Wattez H, et al. Outcomes of endovascular aneurysm repair performed in abdominal aortic aneurysms with large infrarenal necks. J Vasc Surg. 2017;66:1065–72.CrossRefPubMed Gargiulo M, Gallitto E, Wattez H, et al. Outcomes of endovascular aneurysm repair performed in abdominal aortic aneurysms with large infrarenal necks. J Vasc Surg. 2017;66:1065–72.CrossRefPubMed
88.
go back to reference Howard DPJ, Marron CD, Sideso E, et al; The Global Registry for Endovascular Aortic Treatment (GREAT) Investigators. Influence of proximal aortic neck diameter on durability of aneurysm sealing and overall survival in patients undergoing endovascular aneurysm repair. Real world data from the Gore global registry for endovascular aortic treatment (GREAT). Eur J Vasc Endovasc Surg. 2018;56:189-199. Howard DPJ, Marron CD, Sideso E, et al; The Global Registry for Endovascular Aortic Treatment (GREAT) Investigators. Influence of proximal aortic neck diameter on durability of aneurysm sealing and overall survival in patients undergoing endovascular aneurysm repair. Real world data from the Gore global registry for endovascular aortic treatment (GREAT). Eur J Vasc Endovasc Surg. 2018;56:189-199.
89.
go back to reference Aburahma AF, DerDerian T, AbuRahma ZT, et al. Comparative study of clinical outcome of endovascular aortic aneurysm repair in large diameter aortic necks (> 31 mm) versus smaller necks. J Vasc Surg. 2018;68:1345–53.CrossRefPubMed Aburahma AF, DerDerian T, AbuRahma ZT, et al. Comparative study of clinical outcome of endovascular aortic aneurysm repair in large diameter aortic necks (> 31 mm) versus smaller necks. J Vasc Surg. 2018;68:1345–53.CrossRefPubMed
90.
go back to reference Oliveira NFG, Bastos Goncalves FM, Ultee K, et al. Patients with large neck diameter have a higher risk of type IA endoleaks and aneurysm rupture after standard endovascular aneurysm repair. J Vasc Surg. 2018 (Epub ahead of print). Oliveira NFG, Bastos Goncalves FM, Ultee K, et al. Patients with large neck diameter have a higher risk of type IA endoleaks and aneurysm rupture after standard endovascular aneurysm repair. J Vasc Surg. 2018 (Epub ahead of print).
91.
go back to reference McFarland G, Tran K, Virgin-Downey W, et al. Infrarenal endovascular aneurysm repair with large device (34- to 36-mm) diameters is associated with higher risk of proximal fixation failure. J Vasc Surg. 2019;69:385–93.CrossRefPubMed McFarland G, Tran K, Virgin-Downey W, et al. Infrarenal endovascular aneurysm repair with large device (34- to 36-mm) diameters is associated with higher risk of proximal fixation failure. J Vasc Surg. 2019;69:385–93.CrossRefPubMed
92.
go back to reference Monahan TS, Chuter TAM, Reilly LM, et al. Long-term follow-up of neck expansion after endovascular aortic aneurysm repair. J Vasc Surg. 2010;52:303–7.CrossRefPubMedPubMedCentral Monahan TS, Chuter TAM, Reilly LM, et al. Long-term follow-up of neck expansion after endovascular aortic aneurysm repair. J Vasc Surg. 2010;52:303–7.CrossRefPubMedPubMedCentral
93.
go back to reference Oberhuber A, Buecken M, Hoffmann MH, et al. Comparison of aortic neck dilatation after open and endovascular repair of abdominal aortic aneurysm. J Vasc Surg. 2012;55:929–34.CrossRefPubMed Oberhuber A, Buecken M, Hoffmann MH, et al. Comparison of aortic neck dilatation after open and endovascular repair of abdominal aortic aneurysm. J Vasc Surg. 2012;55:929–34.CrossRefPubMed
94.
go back to reference Tsilimparis N, Dayama A, Ricotta JJ. Remodeling of aortic aneurysm and aortic neck on mid- and long-term follow-up after endovascular repair with suprarenal fixation. J Vasc Surg. 2015;61:28–34.CrossRefPubMed Tsilimparis N, Dayama A, Ricotta JJ. Remodeling of aortic aneurysm and aortic neck on mid- and long-term follow-up after endovascular repair with suprarenal fixation. J Vasc Surg. 2015;61:28–34.CrossRefPubMed
95.
go back to reference Kret MR, Tran K, Lee JT. Change in aortic neck diameter after endovascular aortic aneurysm repair. Ann Vasc Surg. 2017;43:115–20.CrossRefPubMed Kret MR, Tran K, Lee JT. Change in aortic neck diameter after endovascular aortic aneurysm repair. Ann Vasc Surg. 2017;43:115–20.CrossRefPubMed
96.
go back to reference Tepe G, Bantleon R, Brechtel K, et al. Management of peripheral arterial interventions with mono or dual antiplatelet therapy—the MIRROR study: a randomized and double blinded clinical trial. Eur Radiol. 2012;22:1998–2006.CrossRefPubMed Tepe G, Bantleon R, Brechtel K, et al. Management of peripheral arterial interventions with mono or dual antiplatelet therapy—the MIRROR study: a randomized and double blinded clinical trial. Eur Radiol. 2012;22:1998–2006.CrossRefPubMed
97.
go back to reference Moll F, Baumgartner I, Jaff M, et al. Edoxaban plus aspirin vs dual antiplatelet therapy in endovascular treatment of patients with peripheral artery disease: results of the ePAD trial. J Endovasc Ther. 2018;25:158–68.CrossRefPubMedPubMedCentral Moll F, Baumgartner I, Jaff M, et al. Edoxaban plus aspirin vs dual antiplatelet therapy in endovascular treatment of patients with peripheral artery disease: results of the ePAD trial. J Endovasc Ther. 2018;25:158–68.CrossRefPubMedPubMedCentral
98.
go back to reference Patel R, sweeting MJ, Powell JT, Greenhalgh RM, for the EVAR trial Investigators. Endovascular versus open repair of abdominal aortic aneurysm in 15-years’ follow-up of the UK endovascular aneurysm repair trial 1 (EVAR trial 1): a randomized controlled trial. Lancet. 2016;388:2366-2374. Patel R, sweeting MJ, Powell JT, Greenhalgh RM, for the EVAR trial Investigators. Endovascular versus open repair of abdominal aortic aneurysm in 15-years’ follow-up of the UK endovascular aneurysm repair trial 1 (EVAR trial 1): a randomized controlled trial. Lancet. 2016;388:2366-2374.
99.
go back to reference Garg T, Baker LC, Mell MW, et al. Adherence to postoperative surveillance guidelines after endovascular aortic aneurysm repair among medicare beneficiaries. J Vasc Surg. 2015;61:23–7.CrossRefPubMed Garg T, Baker LC, Mell MW, et al. Adherence to postoperative surveillance guidelines after endovascular aortic aneurysm repair among medicare beneficiaries. J Vasc Surg. 2015;61:23–7.CrossRefPubMed
100.
101.
go back to reference Spanos K, Karathanos C, Athanasoulas A, et al. Systematic review of follow-up compliance after endovascular abdominal aortic aneurysm repair. J Cardiovasc Surg. 2018;59:611–8.CrossRef Spanos K, Karathanos C, Athanasoulas A, et al. Systematic review of follow-up compliance after endovascular abdominal aortic aneurysm repair. J Cardiovasc Surg. 2018;59:611–8.CrossRef
102.
go back to reference Wu CY, Chen H, Gallagher KA, et al. Predictors of compliance with surveillance after endovascular aneurysm repair and comparative survival outcomes. J Vasc Surg. 2015;62:27–35.CrossRefPubMed Wu CY, Chen H, Gallagher KA, et al. Predictors of compliance with surveillance after endovascular aneurysm repair and comparative survival outcomes. J Vasc Surg. 2015;62:27–35.CrossRefPubMed
103.
go back to reference De Mestral C, Croxford R, Eisenberg N, et al. The impact of compliance with imaging follow-up on mortality after endovascular abdominal aortic aneurysm repair: a population based cohort study. Eur J Vasc Endovasc Surg. 2017;54:315–23.CrossRefPubMed De Mestral C, Croxford R, Eisenberg N, et al. The impact of compliance with imaging follow-up on mortality after endovascular abdominal aortic aneurysm repair: a population based cohort study. Eur J Vasc Endovasc Surg. 2017;54:315–23.CrossRefPubMed
104.
go back to reference Goncalves FB, van de Luijtgaarden KM, Hoeks SE, et al. Adequate seal and no endoleak on the first postoperative computed tomography angiography as criteria for no additional imaging up to 5 years after endovascular aneurysm repair. J Vasc Surg. 2013;57:1503–11.CrossRef Goncalves FB, van de Luijtgaarden KM, Hoeks SE, et al. Adequate seal and no endoleak on the first postoperative computed tomography angiography as criteria for no additional imaging up to 5 years after endovascular aneurysm repair. J Vasc Surg. 2013;57:1503–11.CrossRef
105.
go back to reference Troutman DA, Chaudry M, Dougherty MJ, et al. Endovascular aortic aneurysm repair surveillance may not be necessary for the first 3 years after an initially normal duplex postoperative study. J Vasc Surg. 2014;60:558–62.CrossRefPubMed Troutman DA, Chaudry M, Dougherty MJ, et al. Endovascular aortic aneurysm repair surveillance may not be necessary for the first 3 years after an initially normal duplex postoperative study. J Vasc Surg. 2014;60:558–62.CrossRefPubMed
106.
go back to reference Baderkhan H, Haller O, Wanhainen A, et al. Follow-up after endovascular aortic aneurysm repair can be stratified based on first postoperative imaging. Br J Surg. 2018;105:709–18.CrossRefPubMed Baderkhan H, Haller O, Wanhainen A, et al. Follow-up after endovascular aortic aneurysm repair can be stratified based on first postoperative imaging. Br J Surg. 2018;105:709–18.CrossRefPubMed
107.
go back to reference Chaer RA, Gushchin A, Rhee R, et al. Duplex ultrasound as the sole long-term surveillance method post-endovascular aneurysm repair: a safe alternative for stable aneurysms. J Vasc Surg. 2009;49:845–9.CrossRefPubMed Chaer RA, Gushchin A, Rhee R, et al. Duplex ultrasound as the sole long-term surveillance method post-endovascular aneurysm repair: a safe alternative for stable aneurysms. J Vasc Surg. 2009;49:845–9.CrossRefPubMed
108.
go back to reference Gray C, Goodman P, Herron CC, et al. Use of color duplex ultrasound as a first line surveillance tool following EVAR is associated with a reduction in cost without compromising accuracy. Eur J Vasc Endovasc Surg. 2012;44:145–50.CrossRefPubMed Gray C, Goodman P, Herron CC, et al. Use of color duplex ultrasound as a first line surveillance tool following EVAR is associated with a reduction in cost without compromising accuracy. Eur J Vasc Endovasc Surg. 2012;44:145–50.CrossRefPubMed
109.
go back to reference Iezzi R, Basilico R, Giancristofaro D, et al. Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2009;49:552–60.CrossRefPubMed Iezzi R, Basilico R, Giancristofaro D, et al. Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2009;49:552–60.CrossRefPubMed
110.
go back to reference Ten Bosch JA, Rouwet EV, Peters CTH, et al. Contrast enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair. J Vasc Interv Radiol. 2010;21:638–43.CrossRefPubMed Ten Bosch JA, Rouwet EV, Peters CTH, et al. Contrast enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair. J Vasc Interv Radiol. 2010;21:638–43.CrossRefPubMed
111.
go back to reference Perini P, Sediri I, Midulla M, et al. Single-center prospective comparison between contrast-enhanced ultrasound and computed tomography angiography after EVAR. Eur J Vasc Endovasc Surg. 2011;42:797–802.CrossRefPubMed Perini P, Sediri I, Midulla M, et al. Single-center prospective comparison between contrast-enhanced ultrasound and computed tomography angiography after EVAR. Eur J Vasc Endovasc Surg. 2011;42:797–802.CrossRefPubMed
112.
go back to reference Bredahl KK, Taudorf M, Lonn L, et al. Contrast enhanced ultrasound can replace computed tomography angiography for surveillance after endovascular aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2016;52:729–35.CrossRef Bredahl KK, Taudorf M, Lonn L, et al. Contrast enhanced ultrasound can replace computed tomography angiography for surveillance after endovascular aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2016;52:729–35.CrossRef
113.
go back to reference Chisci E, Harris L, Guidotti A, et al. Endovascular aortic repair follow up protocol based on contrast enhanced ultrasound is safe and effective. Eur J Vasc Endovasc Surg. 2018;56:40–7.CrossRefPubMed Chisci E, Harris L, Guidotti A, et al. Endovascular aortic repair follow up protocol based on contrast enhanced ultrasound is safe and effective. Eur J Vasc Endovasc Surg. 2018;56:40–7.CrossRefPubMed
114.
go back to reference Karthikesalingam A, Al-Jundi W, Jackson D, et al. Systematic review and meta-analysis of duplex ultrasonography, contrast–enhanced ultrasonography or computed tomography for surveillance after endovascular aneurysm repair. Br J Surg. 2012;99:1514–23.CrossRefPubMed Karthikesalingam A, Al-Jundi W, Jackson D, et al. Systematic review and meta-analysis of duplex ultrasonography, contrast–enhanced ultrasonography or computed tomography for surveillance after endovascular aneurysm repair. Br J Surg. 2012;99:1514–23.CrossRefPubMed
115.
go back to reference Hobo R, Sybrandy JEM, Harris P, et al. Endovascular repair of abdominal aortic aneurysms with concomitant iliac artery aneurysm. Outcome analysis of the EUROSTAR experience. J Endovasc Ther. 2008;15:12–22.CrossRefPubMed Hobo R, Sybrandy JEM, Harris P, et al. Endovascular repair of abdominal aortic aneurysms with concomitant iliac artery aneurysm. Outcome analysis of the EUROSTAR experience. J Endovasc Ther. 2008;15:12–22.CrossRefPubMed
116.
go back to reference Albertini JN, Favre JP, Bouziane Z, et al. Aneurysmal extension to the iliac bifurcation increases the risk of complications and secondary procedures after endovascular repair of abdominal aortic aneurysms. Ann Vasc Surg. 2010;24:663–9.CrossRefPubMed Albertini JN, Favre JP, Bouziane Z, et al. Aneurysmal extension to the iliac bifurcation increases the risk of complications and secondary procedures after endovascular repair of abdominal aortic aneurysms. Ann Vasc Surg. 2010;24:663–9.CrossRefPubMed
117.
go back to reference Fatima J, Oderich GS. Technical aspects and results of hybrid iliac revascularization. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 42. Springer International Publishing AG; 2017. p. 641–649. Fatima J, Oderich GS. Technical aspects and results of hybrid iliac revascularization. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 42. Springer International Publishing AG; 2017. p. 641–649.
118.
go back to reference Ghosh J, Murray D, Paravast S, et al. Contemporary management of aorto-iliac aneurysms in the endovascular era. Eur J Vasc Endovasc Surg. 2009;37:182–8.CrossRefPubMed Ghosh J, Murray D, Paravast S, et al. Contemporary management of aorto-iliac aneurysms in the endovascular era. Eur J Vasc Endovasc Surg. 2009;37:182–8.CrossRefPubMed
119.
go back to reference Bekdache K, Dietzek AM, Cha A, et al. Endovascular hypogastric artery preservation during endovascular aneurysm repair: a review of current techniques and devices. Ann Vasc Surg. 2015;29:367–76.CrossRefPubMed Bekdache K, Dietzek AM, Cha A, et al. Endovascular hypogastric artery preservation during endovascular aneurysm repair: a review of current techniques and devices. Ann Vasc Surg. 2015;29:367–76.CrossRefPubMed
120.
go back to reference Torsello G, Schonefeld E, Osada N, et al. Endovascular treatment of common iliac artery aneurysms using the bell-bottom technique: long-term results. J Endovasc Ther. 2010;17:504–9.CrossRefPubMed Torsello G, Schonefeld E, Osada N, et al. Endovascular treatment of common iliac artery aneurysms using the bell-bottom technique: long-term results. J Endovasc Ther. 2010;17:504–9.CrossRefPubMed
121.
go back to reference Naughton PA, Parl MS, Kheirelseid EAH, et al. A comparative study of the bell-bottom technique versus hypogastric exclusion for the treatment of aneurysmal extension to the iliac bifurcation. J Vasc Surg. 2012;55:956–62.CrossRefPubMedPubMedCentral Naughton PA, Parl MS, Kheirelseid EAH, et al. A comparative study of the bell-bottom technique versus hypogastric exclusion for the treatment of aneurysmal extension to the iliac bifurcation. J Vasc Surg. 2012;55:956–62.CrossRefPubMedPubMedCentral
122.
go back to reference Griffin CL, Scali ST, Feezor RJ. Fate of aneurysmal common iliac artery landing zones used for endovascular aneurysm repair. J Endovasc Ther. 2015;22:748–9.CrossRefPubMedPubMedCentral Griffin CL, Scali ST, Feezor RJ. Fate of aneurysmal common iliac artery landing zones used for endovascular aneurysm repair. J Endovasc Ther. 2015;22:748–9.CrossRefPubMedPubMedCentral
123.
go back to reference Gray D, Shahverdyan R, Reifferscheid V, et al. EVAR with flared iliac limbs has a high risk of late type 1b endoleak. Eur J Vasc Endovasc Surg. 2017;54:170–6.CrossRefPubMed Gray D, Shahverdyan R, Reifferscheid V, et al. EVAR with flared iliac limbs has a high risk of late type 1b endoleak. Eur J Vasc Endovasc Surg. 2017;54:170–6.CrossRefPubMed
124.
go back to reference Lee WA, Nelson PR, Berceli SA, et al. Outcome after hypogastric artery bypass and embolization during endovascular aneurysm repair. J Vasc Surg. 2006;44:1162–9.CrossRefPubMed Lee WA, Nelson PR, Berceli SA, et al. Outcome after hypogastric artery bypass and embolization during endovascular aneurysm repair. J Vasc Surg. 2006;44:1162–9.CrossRefPubMed
125.
go back to reference Unno N, Inuzuka K, Yamamoto N, et al. Preservation of pelvis circulation with hypogastric artery bypass in endovascular repair of abdominal aortic aneurysms with bilateral iliac artery aneurysms. J Vasc Surg. 2006;44:1170–5.CrossRefPubMed Unno N, Inuzuka K, Yamamoto N, et al. Preservation of pelvis circulation with hypogastric artery bypass in endovascular repair of abdominal aortic aneurysms with bilateral iliac artery aneurysms. J Vasc Surg. 2006;44:1170–5.CrossRefPubMed
126.
go back to reference Mansukhani NA, Havelka GE, Helenowski IB, et al. Hibrid EVAR: preservation of pelvic perfusion with external to internal iliac artery bypass. Ann Vasc Surg. 2017;42:162–8.CrossRefPubMedPubMedCentral Mansukhani NA, Havelka GE, Helenowski IB, et al. Hibrid EVAR: preservation of pelvic perfusion with external to internal iliac artery bypass. Ann Vasc Surg. 2017;42:162–8.CrossRefPubMedPubMedCentral
127.
go back to reference Tyagi S, Pineda D, Zheng H, et al. A novel method for the treatment of bilateral hypogastric aneurysms using hybrid polytetrafluoroethylene graft. Vasc Endovasc Surg. 2017;51:199–202.CrossRef Tyagi S, Pineda D, Zheng H, et al. A novel method for the treatment of bilateral hypogastric aneurysms using hybrid polytetrafluoroethylene graft. Vasc Endovasc Surg. 2017;51:199–202.CrossRef
128.
go back to reference DeRubertis BG, Quinones-Baldrich WJ, Greenberg JI, et al. Results of a double-barrel technique with commercially available devices for hypogastric preservation aortoiliac endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2012;56:1252–9.CrossRefPubMed DeRubertis BG, Quinones-Baldrich WJ, Greenberg JI, et al. Results of a double-barrel technique with commercially available devices for hypogastric preservation aortoiliac endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2012;56:1252–9.CrossRefPubMed
129.
go back to reference Ricci C, Ceccherini C, Cini M, et al. Single-center experience and 1-year follow-up results of “sandwich technique” in the management of common iliac artery aneurysms during EVAR. Cardiovasc Intervent Radiol. 2012;35:1195–200.CrossRefPubMed Ricci C, Ceccherini C, Cini M, et al. Single-center experience and 1-year follow-up results of “sandwich technique” in the management of common iliac artery aneurysms during EVAR. Cardiovasc Intervent Radiol. 2012;35:1195–200.CrossRefPubMed
130.
go back to reference Lobato AC, Camacho-Lobato L. The sandwich technique to treat complex aortoiliac or isolated iliac aneurysms: results of mid-term follow-up. J Vasc Surg. 2013;57:26S–34S.CrossRefPubMed Lobato AC, Camacho-Lobato L. The sandwich technique to treat complex aortoiliac or isolated iliac aneurysms: results of mid-term follow-up. J Vasc Surg. 2013;57:26S–34S.CrossRefPubMed
131.
go back to reference Lepidi S, Piazza M, Scrivere P, et al. Parallel endografts in the treatment of distal aortic and common iliac aneurysms. Eur J Vasc Endovasc Surg. 2014;48:29–37.CrossRefPubMed Lepidi S, Piazza M, Scrivere P, et al. Parallel endografts in the treatment of distal aortic and common iliac aneurysms. Eur J Vasc Endovasc Surg. 2014;48:29–37.CrossRefPubMed
132.
go back to reference Massmann A, Mosquera Arochena NJ, Shayesteh-Kheslat R, et al. Endovascular anatomic reconstruction of the iliac bifurcation with covered stent-grafts in sandwich-technique for the treatment of complex aorto-iliac aneurysms. Int J Cardiol. 2016;222:332–9.CrossRefPubMed Massmann A, Mosquera Arochena NJ, Shayesteh-Kheslat R, et al. Endovascular anatomic reconstruction of the iliac bifurcation with covered stent-grafts in sandwich-technique for the treatment of complex aorto-iliac aneurysms. Int J Cardiol. 2016;222:332–9.CrossRefPubMed
133.
go back to reference Minion D. Off-label use of aortic devices and parallel stent grafts for iliac revascularization. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 40. Springer International Publishing AG; 2017. p. 595–622. Minion D. Off-label use of aortic devices and parallel stent grafts for iliac revascularization. In: Oderich GS, editor. Endovascular aortic repair. Current techniques with fenestrated, branched and parallel stent-grafts, vol. 40. Springer International Publishing AG; 2017. p. 595–622.
134.
go back to reference Oderich GS, Ricotta JS. Novel surgeon-modified hypogastric branch stent graft to preserve pelvic perfusion. Ann Vasc Surg. 2010;24:278–86.CrossRefPubMed Oderich GS, Ricotta JS. Novel surgeon-modified hypogastric branch stent graft to preserve pelvic perfusion. Ann Vasc Surg. 2010;24:278–86.CrossRefPubMed
135.
go back to reference Nykamp M, Anderson J, Remund T, et al. Use of physician-modified endografts to repair unilateral or bilateral aortoiliac aneurysms. Ann Vac Surg. 2015;29:1468–74.CrossRef Nykamp M, Anderson J, Remund T, et al. Use of physician-modified endografts to repair unilateral or bilateral aortoiliac aneurysms. Ann Vac Surg. 2015;29:1468–74.CrossRef
136.
go back to reference Bergamini TM, Rachel ES, Kinney EV, et al. External iliac artery–to–internal iliac artery endograft: a novel approach to preserve pelvic inflow in aortoiliac stent grafting. J Vasc Surg. 2002;35:120–4.CrossRefPubMed Bergamini TM, Rachel ES, Kinney EV, et al. External iliac artery–to–internal iliac artery endograft: a novel approach to preserve pelvic inflow in aortoiliac stent grafting. J Vasc Surg. 2002;35:120–4.CrossRefPubMed
137.
go back to reference Hossain S, Steinmetw OK, Corriveau MM, et al. Patency of the contralateral internal iliac artery in aortouni-iliac endografting. J Vasc Surg. 2016;63:974–82.CrossRefPubMed Hossain S, Steinmetw OK, Corriveau MM, et al. Patency of the contralateral internal iliac artery in aortouni-iliac endografting. J Vasc Surg. 2016;63:974–82.CrossRefPubMed
138.
go back to reference Stokmans RA, Willigendael EM, Teijink JA, et al. Challenging the evidence for pre-emptive coil embolization of the internal iliac artery during endovascular aneurysm repair. Eur J Vasc Endovasc Surg. 2013;45:220–6.CrossRefPubMed Stokmans RA, Willigendael EM, Teijink JA, et al. Challenging the evidence for pre-emptive coil embolization of the internal iliac artery during endovascular aneurysm repair. Eur J Vasc Endovasc Surg. 2013;45:220–6.CrossRefPubMed
139.
go back to reference Kontopodis N, Tavlas E, Papadopoulos G, et al. Embolization or simple coverage to exclude the internal iliac artery during endovascular repair of aortoiliac aneurysms? Systematic review and meta-analysis of comparative studies. J Endovasc Ther. 2017;24:47–56.CrossRefPubMed Kontopodis N, Tavlas E, Papadopoulos G, et al. Embolization or simple coverage to exclude the internal iliac artery during endovascular repair of aortoiliac aneurysms? Systematic review and meta-analysis of comparative studies. J Endovasc Ther. 2017;24:47–56.CrossRefPubMed
140.
go back to reference Stokmans RA, Broos PPHL, van Sambeek MRHM, et al. Overstenting the hypogastric artery during endovascular aneurysm repair with and without prior coil embolization: a comparative analysis from the ENGAGE registry. J Vasc Surg. 2018;67:134–41.CrossRefPubMed Stokmans RA, Broos PPHL, van Sambeek MRHM, et al. Overstenting the hypogastric artery during endovascular aneurysm repair with and without prior coil embolization: a comparative analysis from the ENGAGE registry. J Vasc Surg. 2018;67:134–41.CrossRefPubMed
141.
go back to reference Kouvelos GN, Koutsoumpelis A, Peroulis M, et al. In endovascular aneurysm repair cases, when should you consider internal iliac artery embolization when extending a stent into the external iliac artery? Interact CardioVasc Thorac Surg. 2014;18:821–4.CrossRefPubMed Kouvelos GN, Koutsoumpelis A, Peroulis M, et al. In endovascular aneurysm repair cases, when should you consider internal iliac artery embolization when extending a stent into the external iliac artery? Interact CardioVasc Thorac Surg. 2014;18:821–4.CrossRefPubMed
Metadata
Title
Current Status of Endovascular Preservation of the Internal Iliac Artery with Iliac Branch Devices (IBD)
Authors
Mario D’Oria
Davide Mastrorilli
Randall DeMartino
Sandro Lepidi
Publication date
01-07-2019
Publisher
Springer US
Published in
CardioVascular and Interventional Radiology / Issue 7/2019
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-019-02199-5

Other articles of this Issue 7/2019

CardioVascular and Interventional Radiology 7/2019 Go to the issue