Published in: Netherlands Heart Journal 4/2014

01-04-2014 | Imaging in Cardiology

An unusual fistula closed by percutaneous coil embolisation

Authors: K. Onsea, W. Budts

Published in: Netherlands Heart Journal | Issue 4/2014

Login to get access

Excerpt

A 25-year-old male patient was admitted for assessment of increasing shortness of breath and decreased transcutaneous oxygen saturation (91 %). He had a complex congenital heart defect, involving a dysplastic monocusp tricuspid valve and pulmonary valve atresia. The latter was palliated shortly after birth by a Brock procedure (entailing infundibular resection and pulmonary valvotomy). An atrial septal defect was surgically closed when he was 6 years old and a homograft was inserted in the right ventricular outflow tract at the age of 15. Replacement by a second homograft at the age of 23 was necessary together with tricuspid valvoplasty because of severe insufficiency of both valves. Apart from moderate pulmonary homograft stenosis (PHS) and re-occurrence of moderate to severe tricuspid insufficiency (TI) resulting in right heart failure, a right-left shunt was detected on transoesophageal echocardiography during intravenous agitated saline bubble-contrast injection, although the repaired atrial septum was intact. Invasive evaluation confirmed moderate to severe TI and a peak-to-peak gradient of 40 mmHg over the homograft. Right atrial pressures were above 20 mmHg. Contrast injection in the superior vena cava showed a very tortuous fistulous connection originating from the left axillary vein and draining towards the left atrium (Fig. 1, panel A and B). It was decided to close the fistula percutaneously and 4 coils (3 x IMWCE-3-PDA3 and 1 x IMWCE-3-PDA5, COOK MEDICAL, Bloomington, USA) were placed in the fistula, effectively occluding the vessel (panel C). The transcutaneous oxygen saturation increased slightly. Further management regarding the TI and PHS will be discussed with one option being percutaneous placement of a pulmonary valve (Medtronic, Minneapolis, USA), possibly in combination with another transcatheter valve prosthesis in tricuspid position to lower the right heart filling pressures.
Metadata
Title
An unusual fistula closed by percutaneous coil embolisation
Authors
K. Onsea
W. Budts
Publication date
01-04-2014
Publisher
Bohn Stafleu van Loghum
Published in
Netherlands Heart Journal / Issue 4/2014
Print ISSN: 1568-5888
Electronic ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-012-0282-x

Other articles of this Issue 4/2014

Netherlands Heart Journal 4/2014 Go to the issue

Rhythm Puzzle - Question

Think twice before you tell