Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2009

Open Access 01-12-2009 | Case report

Impingement syndrome of the shoulder following double row suture anchor technique for arthroscopic rotator cuff repair: a case report

Authors: Rohit Rambani, Roger G Hackney

Published in: Journal of Medical Case Reports | Issue 1/2009

Login to get access

Abstract

Introduction

Arthroscopic repair of the rotator cuff is a demanding surgery. Accurate placement of anchors is key to success.

Case presentation

A 38-year-old woman received arthroscopic repair of her rotator cuff using a double row suture anchor technique. Postoperatively, she developed impingement syndrome which resulted from vertical displacement of a suture anchor once the shoulder was mobilised. The anchor was removed eight weeks following initial surgery and the patient had an uneventful recovery.

Conclusion

Impingement syndrome following arthroscopic repair of the rotator cuffs using double row suture anchor has not been widely reported. This is the first such case where anchoring has resulted in impingement syndrome.
Literature
1.
go back to reference Iannotti JP: Full-Thickness Rotator Cuff Tears: Factors Affecting Surgical Outcome. J Am Acad Orthop Surg. 1994, 2: 87-95.CrossRefPubMed Iannotti JP: Full-Thickness Rotator Cuff Tears: Factors Affecting Surgical Outcome. J Am Acad Orthop Surg. 1994, 2: 87-95.CrossRefPubMed
2.
go back to reference Sugaya H: Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy. 2005, 21: 1307-1316. 10.1016/j.arthro.2005.08.011.CrossRefPubMed Sugaya H: Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy. 2005, 21: 1307-1316. 10.1016/j.arthro.2005.08.011.CrossRefPubMed
3.
go back to reference Lafosse L: The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Joint Surg Am. 2007, 89: 1533-1541. 10.2106/JBJS.F.00305.CrossRefPubMed Lafosse L: The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Joint Surg Am. 2007, 89: 1533-1541. 10.2106/JBJS.F.00305.CrossRefPubMed
4.
go back to reference Boileau P: Arthroscopic repair of full-thickness tears of the supraspinatus: does the tendon really heal?. J Bone Joint Surg Am. 2005, 87: 1229-1240. 10.2106/JBJS.D.02035.CrossRefPubMed Boileau P: Arthroscopic repair of full-thickness tears of the supraspinatus: does the tendon really heal?. J Bone Joint Surg Am. 2005, 87: 1229-1240. 10.2106/JBJS.D.02035.CrossRefPubMed
5.
go back to reference Bishop J: Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg. 2006, 15: 290-299. 10.1016/j.jse.2005.09.017.CrossRefPubMed Bishop J: Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg. 2006, 15: 290-299. 10.1016/j.jse.2005.09.017.CrossRefPubMed
6.
go back to reference Kircher J, Martinek V, Mittelmeier W: Heterotopic ossification after minimally invasive rotator cuff repair. Arthroscopy. 2007, 23: 1359 e1-3-10.1016/j.arthro.2006.10.020.CrossRefPubMed Kircher J, Martinek V, Mittelmeier W: Heterotopic ossification after minimally invasive rotator cuff repair. Arthroscopy. 2007, 23: 1359 e1-3-10.1016/j.arthro.2006.10.020.CrossRefPubMed
7.
go back to reference Boszotta H, Prunner K: Arthroscopically assisted rotator cuff repair. Arthroscopy. 2004, 20: 620-626. 10.1016/j.arthro.2004.04.058.CrossRefPubMed Boszotta H, Prunner K: Arthroscopically assisted rotator cuff repair. Arthroscopy. 2004, 20: 620-626. 10.1016/j.arthro.2004.04.058.CrossRefPubMed
8.
go back to reference Green LB: Sources of variation in readmission rates, length of stay, and operative time associated with rotator cuff surgery. J Bone Joint Surg Am. 2003, 85A: 1784-1789. Green LB: Sources of variation in readmission rates, length of stay, and operative time associated with rotator cuff surgery. J Bone Joint Surg Am. 2003, 85A: 1784-1789.
9.
go back to reference Brislin KJ, Field LD, Savoie FH: Complications after arthroscopic rotator cuff repair. Arthroscopy. 2007, 23: 124-128. 10.1016/j.arthro.2006.09.001.CrossRefPubMed Brislin KJ, Field LD, Savoie FH: Complications after arthroscopic rotator cuff repair. Arthroscopy. 2007, 23: 124-128. 10.1016/j.arthro.2006.09.001.CrossRefPubMed
10.
go back to reference Dines DM: The coracoid impingement syndrome. J Bone Joint Surg Br. 1990, 72: 314-316.PubMed Dines DM: The coracoid impingement syndrome. J Bone Joint Surg Br. 1990, 72: 314-316.PubMed
11.
go back to reference Barber FA, Cawley P, Prudich JF: Suture anchor failure strength-an in vivo study. Arthroscopy. 1993, 9: 647-652. 10.1016/S0749-8063(05)80500-6.CrossRefPubMed Barber FA, Cawley P, Prudich JF: Suture anchor failure strength-an in vivo study. Arthroscopy. 1993, 9: 647-652. 10.1016/S0749-8063(05)80500-6.CrossRefPubMed
12.
go back to reference Park MC: Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques. Am J Sports Med. 2005, 33: 1154-1159. 10.1177/0363546504273053.CrossRefPubMed Park MC: Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques. Am J Sports Med. 2005, 33: 1154-1159. 10.1177/0363546504273053.CrossRefPubMed
13.
go back to reference Bey MJ: In vivo measurement of subacromial space width during shoulder elevation: technique and preliminary results in patients following unilateral rotator cuff repair. Clin Biomech (Bristol, Avon). 2007, 22: 767-773. 10.1016/j.clinbiomech.2007.04.006.CrossRef Bey MJ: In vivo measurement of subacromial space width during shoulder elevation: technique and preliminary results in patients following unilateral rotator cuff repair. Clin Biomech (Bristol, Avon). 2007, 22: 767-773. 10.1016/j.clinbiomech.2007.04.006.CrossRef
Metadata
Title
Impingement syndrome of the shoulder following double row suture anchor technique for arthroscopic rotator cuff repair: a case report
Authors
Rohit Rambani
Roger G Hackney
Publication date
01-12-2009
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2009
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.4076/1752-1947-3-8109

Other articles of this Issue 1/2009

Journal of Medical Case Reports 1/2009 Go to the issue