Abstract

Background

There is a need for an easily accessible method for effective dose estimation in pediatric CT.

Objective

To estimate effective doses for a variety of pediatric neurological and body CT examinations in five age groups using recently published age- and region-specific dose length product (DLP) to effective dose conversion coefficients.

Materials and methods

A retrospective review was performed of 1,431 consecutive CT scans over a 12-week period using age- and weight-adjusted CT protocols. Age- and region-specific DLP to effective dose conversion coefficients were applied to console-displayed DLP data.

Results

Effective dose estimates for single-phase head CT scans in neonatal, and 1-, 5-, 10- and 15-year-old age groups were 4.2, 3.6, 2.4, 2.0 and 1.4 mSv, respectively. For abdomen/pelvis CT scans the corresponding effective doses were 13.1, 11.1, 8.4, 8.9 and 5.9 mSv. The range of pediatric CT effective doses is wide, from ultralow dose protocols (<1 mSv) to extended-coverage body examinations (10–15 mSv).

Conclusion

Age- and region-specific pediatric DLP to effective dose conversion coefficients provide an accessible and user-friendly method for estimating pediatric CT effective doses that is available to radiologists working without medical physics support.
Literature
1.
go back to reference Linton OW, Mettler FA (2003) National conference on dose reduction in CT with particular emphasis on pediatric patients. AJR 181:321–329PubMed Linton OW, Mettler FA (2003) National conference on dose reduction in CT with particular emphasis on pediatric patients. AJR 181:321–329PubMed
2.
go back to reference Blackwell CD, Gorelick M, Holmes JF et al (2007) Pediatric head trauma: changes in use of computed tomography in emergency departments in the United States over time. Ann Emerg Med 49:320–324PubMedCrossRef Blackwell CD, Gorelick M, Holmes JF et al (2007) Pediatric head trauma: changes in use of computed tomography in emergency departments in the United States over time. Ann Emerg Med 49:320–324PubMedCrossRef
3.
go back to reference Food and Drug Administration (FDA) (2002) Public health notification: reducing radiation risk from computed tomography for pediatric and small adult patients. Pediatr Radiol 32:314–316CrossRef Food and Drug Administration (FDA) (2002) Public health notification: reducing radiation risk from computed tomography for pediatric and small adult patients. Pediatr Radiol 32:314–316CrossRef
4.
go back to reference Brody AS, Frush DP, Huda W et al; American Academy of Pediatrics Section on Radiology (2007) Radiation risk to children from computed tomography. Pediatrics 120:677–682PubMedCrossRef Brody AS, Frush DP, Huda W et al; American Academy of Pediatrics Section on Radiology (2007) Radiation risk to children from computed tomography. Pediatrics 120:677–682PubMedCrossRef
5.
go back to reference McCullough CH, Schueler BA (2000) Educational treatise: calculation of effective dose. Med Phys 27:828–837CrossRef McCullough CH, Schueler BA (2000) Educational treatise: calculation of effective dose. Med Phys 27:828–837CrossRef
6.
7.
go back to reference ICRP (1991) 1990 recommendations of the International Commission on Radiological Protection (publication no. 60). Pergamon, Oxford, UK ICRP (1991) 1990 recommendations of the International Commission on Radiological Protection (publication no. 60). Pergamon, Oxford, UK
8.
go back to reference Almen A, Mattsson S (1996) On the calculation of effective dose to children and adolescents. J Radiol Prot 16:81–89CrossRef Almen A, Mattsson S (1996) On the calculation of effective dose to children and adolescents. J Radiol Prot 16:81–89CrossRef
9.
go back to reference Theocharopoulos N, Damilakis J, Perisinakis K et al (2006) Estimation of effective doses to adult and pediatric patients from multislice computed tomography: a method based on energy imparted. Med Phys 33:3846–3856PubMedCrossRef Theocharopoulos N, Damilakis J, Perisinakis K et al (2006) Estimation of effective doses to adult and pediatric patients from multislice computed tomography: a method based on energy imparted. Med Phys 33:3846–3856PubMedCrossRef
12.
go back to reference Khursheed A, Hillier MC, Shrimpton PC et al (1997) Influence of patient age on normalized effective doses calculated for CT examinations. Br J Radiol 75:819–830 Khursheed A, Hillier MC, Shrimpton PC et al (1997) Influence of patient age on normalized effective doses calculated for CT examinations. Br J Radiol 75:819–830
13.
go back to reference Huda W, Atherton JV, Ware DE et al (1997) An approach for the estimation of effective radiation dose at CT in pediatric patients. Radiology 203:417–422PubMed Huda W, Atherton JV, Ware DE et al (1997) An approach for the estimation of effective radiation dose at CT in pediatric patients. Radiology 203:417–422PubMed
14.
go back to reference Huda W, Gkanatsios NA (1997) Effective dose and energy imparted in diagnostic radiology. Med Phys 24:1311–1316PubMedCrossRef Huda W, Gkanatsios NA (1997) Effective dose and energy imparted in diagnostic radiology. Med Phys 24:1311–1316PubMedCrossRef
17.
go back to reference Shrimpton PC, Hillier MC, Lewis MA et al (2006) National survey of doses from CT in the UK: 2003. Br J Radiol 79:968–980PubMedCrossRef Shrimpton PC, Hillier MC, Lewis MA et al (2006) National survey of doses from CT in the UK: 2003. Br J Radiol 79:968–980PubMedCrossRef
19.
20.
go back to reference Shrimpton PC, Wall BF (2000) Reference doses for paediatric computed tomography. Radiat Prot Dosimetry 90:249–252 Shrimpton PC, Wall BF (2000) Reference doses for paediatric computed tomography. Radiat Prot Dosimetry 90:249–252
21.
go back to reference Chapple C-L, Willis S, Frame J (2002) Effective dose in paediatric computed tomography. Phys Med Biol 47:107–115PubMedCrossRef Chapple C-L, Willis S, Frame J (2002) Effective dose in paediatric computed tomography. Phys Med Biol 47:107–115PubMedCrossRef
22.
go back to reference Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation, National Research Council (2006) Health risks from exposure to low levels of ionizing radiation. BEIR VII Phase 2. National Academies Press, Washington DC Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation, National Research Council (2006) Health risks from exposure to low levels of ionizing radiation. BEIR VII Phase 2. National Academies Press, Washington DC
25.
go back to reference Mayo JR, Aldrich J, Muller N (2003) Radiation exposure at chest CT: a statement of the Fleishner Society. Radiology 228:15–21PubMedCrossRef Mayo JR, Aldrich J, Muller N (2003) Radiation exposure at chest CT: a statement of the Fleishner Society. Radiology 228:15–21PubMedCrossRef
26.
go back to reference Wintersperger B, Jakobs T, Herzog P et al (2005) Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 15:334–341PubMedCrossRef Wintersperger B, Jakobs T, Herzog P et al (2005) Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 15:334–341PubMedCrossRef
27.
go back to reference Hausleiter J, Meyer T, Hadamitzky M et al (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113:1305–1310PubMedCrossRef Hausleiter J, Meyer T, Hadamitzky M et al (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113:1305–1310PubMedCrossRef
28.
go back to reference Zankl M, Panzer, Drexler G (1993) Tomographic anthropomorphic models. Part II: Organ doses from computed tomographic examinations in paediatric radiology. GSF-Bericht 30/93. GSF, Munich Zankl M, Panzer, Drexler G (1993) Tomographic anthropomorphic models. Part II: Organ doses from computed tomographic examinations in paediatric radiology. GSF-Bericht 30/93. GSF, Munich
29.
go back to reference Hollingsworth C, Frush DP, Cross M et al (2003) Helical CT of the body: a survey of techniques used for pediatric patients. AJR 180:401–406PubMed Hollingsworth C, Frush DP, Cross M et al (2003) Helical CT of the body: a survey of techniques used for pediatric patients. AJR 180:401–406PubMed
30.
go back to reference McLean D, Malitz N, Lewis S (2003) Survey of effective dose levels from typical paediatric protocols. Australas Radiol 47:135–142PubMedCrossRef McLean D, Malitz N, Lewis S (2003) Survey of effective dose levels from typical paediatric protocols. Australas Radiol 47:135–142PubMedCrossRef
31.
go back to reference Hurwitz LM, Yoshizumi TT, Goodman PC et al (2007) Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. J Comput Assist Tomogr 31:544–549PubMedCrossRef Hurwitz LM, Yoshizumi TT, Goodman PC et al (2007) Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. J Comput Assist Tomogr 31:544–549PubMedCrossRef
32.
go back to reference Pages J, Buls N, Osteaux M (2003) CT doses in children: a multicentre study. Br J Radiol 76:803–811PubMedCrossRef Pages J, Buls N, Osteaux M (2003) CT doses in children: a multicentre study. Br J Radiol 76:803–811PubMedCrossRef
Metadata
Title
Age-specific effective doses for pediatric MSCT examinations at a large children’s hospital using DLP conversion coefficients: a simple estimation method
Authors
Karen E. Thomas
Bo Wang
Publication date
01-06-2008
Publisher
Springer-Verlag
Published in
Pediatric Radiology / Issue 6/2008
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-008-0794-0

Other articles of this Issue 6/2008

Pediatric Radiology 6/2008 Go to the issue

Hermes

Hermes