Abstract

From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous wireless SpO2 monitoring on hospital wards, and the integration of SpO2 as the input variable for closed-loop oxygen administration systems. The analysis of the pulse oximetry waveform may help to quantify respiratory efforts and prevent intubation delays. Tracking changes in the peripheral perfusion index during a preload-modifying maneuver may be useful to predict preload responsiveness and rationalize fluid therapy.
Literature
1.
go back to reference Shah A, Shelley KH. Is pulse oximetry an essential tool or just another distraction? The role of the pulse oximeter in modern anesthesia care. J Clin Monit Comput. 2013;27:235–42.CrossRef Shah A, Shelley KH. Is pulse oximetry an essential tool or just another distraction? The role of the pulse oximeter in modern anesthesia care. J Clin Monit Comput. 2013;27:235–42.CrossRef
2.
go back to reference Smith GCS, Pell JP. Parachute use to prevent death and major trauma related to gravitational challenge: systematic review of randomized controlled trials. BMJ. 2003;327:1459–61.CrossRef Smith GCS, Pell JP. Parachute use to prevent death and major trauma related to gravitational challenge: systematic review of randomized controlled trials. BMJ. 2003;327:1459–61.CrossRef
3.
go back to reference Michard F, Bellomo R, Taenzer A. The rise of ward monitoring: opportunities and challenges for critical care specialists. Intensive Care Med. 2019;45:671–3.CrossRef Michard F, Bellomo R, Taenzer A. The rise of ward monitoring: opportunities and challenges for critical care specialists. Intensive Care Med. 2019;45:671–3.CrossRef
4.
go back to reference Steinhubl SR, Feye D, Levine AC, et al. Validation of a portable, deployable system for continuous vital sign monitoring using a multiparametric wearable sensor and personalized analytics in an Ebola treatment center. BMJ Glob Health. 2016;1:e000070.CrossRef Steinhubl SR, Feye D, Levine AC, et al. Validation of a portable, deployable system for continuous vital sign monitoring using a multiparametric wearable sensor and personalized analytics in an Ebola treatment center. BMJ Glob Health. 2016;1:e000070.CrossRef
5.
go back to reference L’Her E, Dias P, Gouillou M, et al. Automatic versus manual oxygen administration in the emergency department. Eur Respir J. 2017;50:1602552.CrossRef L’Her E, Dias P, Gouillou M, et al. Automatic versus manual oxygen administration in the emergency department. Eur Respir J. 2017;50:1602552.CrossRef
6.
go back to reference Denault MH, Péloquin F, Lajoie AC, Lacasse Y. Automatic versus manual oxygen titration in patients requiring supplemental oxygen in the hospital: A systematic review and meta-anaylsis. Respiration. 2019;98:178–88.CrossRef Denault MH, Péloquin F, Lajoie AC, Lacasse Y. Automatic versus manual oxygen titration in patients requiring supplemental oxygen in the hospital: A systematic review and meta-anaylsis. Respiration. 2019;98:178–88.CrossRef
7.
go back to reference Brochard L, Slutsky A, Pesenti A. Mechanical ventilation to minimize progression of acute lung injury in acute respiratory failure. Am J Respir Crit Care Med. 2017;195:438–42.CrossRef Brochard L, Slutsky A, Pesenti A. Mechanical ventilation to minimize progression of acute lung injury in acute respiratory failure. Am J Respir Crit Care Med. 2017;195:438–42.CrossRef
11.
go back to reference Frey B, Butt W. Pulse oximetry for assessment of pulsus paradoxus: a clinical study in children. Intensive Care Med. 1988;24:242–6.CrossRef Frey B, Butt W. Pulse oximetry for assessment of pulsus paradoxus: a clinical study in children. Intensive Care Med. 1988;24:242–6.CrossRef
13.
go back to reference Monnet X, Marik P, Teboul JL. Prediction of fluid responsiveness: An update. Ann Intensive Care. 2016;6:111.CrossRef Monnet X, Marik P, Teboul JL. Prediction of fluid responsiveness: An update. Ann Intensive Care. 2016;6:111.CrossRef
14.
go back to reference Beurton A, Teboul JL, Gavelli F, et al. The effects of passive leg raising may be detected by the plethysmographic oxygen saturation signal in critically ill patients. Crit Care. 2019;23:1–10.CrossRef Beurton A, Teboul JL, Gavelli F, et al. The effects of passive leg raising may be detected by the plethysmographic oxygen saturation signal in critically ill patients. Crit Care. 2019;23:1–10.CrossRef
Metadata
Title
COVID-19: Pulse oximeters in the spotlight
Authors
Frederic Michard
Kirk Shelley
Erwan L’Her
Publication date
01-02-2021
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 1/2021
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-020-00550-7

Other articles of this Issue 1/2021

Journal of Clinical Monitoring and Computing 1/2021 Go to the issue