Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 3/2017

01-03-2017 | Original Paper

Accurate quantification of vessel cross-sectional area using CT angiography: a simulation study

Authors: Sabee Molloi, Travis Johnson, Huanjun Ding, Jerry Lipinski

Published in: The International Journal of Cardiovascular Imaging | Issue 3/2017

Login to get access

Abstract

Coronary computed tomography (CT) angiography is a noninvasive method for visualizing coronary atherosclerosis. However, CT angiography is limited in assessment of stenosis severity by the partial volume effect and calcification. Therefore, a quantitative method for assessment of stenosis severity is needed. Polyenergetic fan beam CT simulations were performed to match the geometry of a 320-slice CT scanner. Contrast-enhanced vessel lumens were modeled as 8 mg/ml Iodine solution against a lipid background. Normal vessels were simulated by circles with diameters in the range of 0.1–3 mm. To simulate lesions, 2, 3, and 4 mm diameter vessels were simulated with area stenoses in a range of 10–90 %. The occlusion was created by a circular region of lipid placed within the lumen resulting in a crescent shaped lumen. Each vessel was simulated three times to obtain multiple noise realizations for a total of 126 vessels. Two trained readers performed manual cross-sectional area measurements in simulated normal and stenotic vessels. A new, semi-automated technique based on integrated Hounsfield units was also used to calculate vessel cross-sectional area. There was an excellent correlation between the measured and the known cross-sectional area for both normal and stenotic vessels using the manual and the semi-automated techniques. However, the overall measurement error for the manual method was more than twice as compared with the integrated HU technique. Determination of vessel cross-sectional area using the semi-automated integrated Hounsfield unit technique yields more than a factor of two improvement in accuracy as compared to the existing manual technique for vessels with and without stenosis. This technique can also be used to correct for the effect of coronary calcification.
Literature
1.
go back to reference Achenbach S, Daniel WG (2001) Noninvasive coronary angiography—an acceptable alternative? N Engl J Med 345:1909–1910CrossRefPubMed Achenbach S, Daniel WG (2001) Noninvasive coronary angiography—an acceptable alternative? N Engl J Med 345:1909–1910CrossRefPubMed
2.
go back to reference Budoff MJ, Dowe D, Jollis JG, Gitter M, Sutherland J, Halamert E, Scherer M, Bellinger R, Martin A, Benton R, Delago A, Min JK (2008) Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter accuracy (assessment by coronary computed tomographic angiography of individuals undergoing invasive coronary angiography) trial. J Am Coll Cardiol 52:1724–1732CrossRefPubMed Budoff MJ, Dowe D, Jollis JG, Gitter M, Sutherland J, Halamert E, Scherer M, Bellinger R, Martin A, Benton R, Delago A, Min JK (2008) Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter accuracy (assessment by coronary computed tomographic angiography of individuals undergoing invasive coronary angiography) trial. J Am Coll Cardiol 52:1724–1732CrossRefPubMed
3.
go back to reference Min JK, Shaw LJ, Berman DS (2010) The present state of coronary computed tomography angiography a process in evolution. J Am Coll Cardiol 55:957–965CrossRefPubMed Min JK, Shaw LJ, Berman DS (2010) The present state of coronary computed tomography angiography a process in evolution. J Am Coll Cardiol 55:957–965CrossRefPubMed
4.
go back to reference Schuhbaeck A, Achenbach S, Layritz C, Eisentopf J, Hecker F, Pflederer T, Gauss S, Rixe J, Kalender W, Daniel WG, Lell M, Ropers D (2013) Image quality of ultra-low radiation exposure coronary ct angiography with an effective dose < 0.1 msv using high-pitch spiral acquisition and raw data-based iterative reconstruction. Eur Radiol 23:597–606CrossRefPubMed Schuhbaeck A, Achenbach S, Layritz C, Eisentopf J, Hecker F, Pflederer T, Gauss S, Rixe J, Kalender W, Daniel WG, Lell M, Ropers D (2013) Image quality of ultra-low radiation exposure coronary ct angiography with an effective dose < 0.1 msv using high-pitch spiral acquisition and raw data-based iterative reconstruction. Eur Radiol 23:597–606CrossRefPubMed
5.
go back to reference Goldstein JA, Gallagher MJ, O’Neill WW, Ross MA, O’Neil BJ, Raff GL (2007) A randomized controlled trial of multi-slice coronary computed tomography for evaluation of acute chest pain. J Am Coll Cardiol 49:863–871CrossRefPubMed Goldstein JA, Gallagher MJ, O’Neill WW, Ross MA, O’Neil BJ, Raff GL (2007) A randomized controlled trial of multi-slice coronary computed tomography for evaluation of acute chest pain. J Am Coll Cardiol 49:863–871CrossRefPubMed
6.
go back to reference Meijboom WB, Van Mieghem CA, van Pelt N, Weustink A, Pugliese F, Mollet NR, Boersma E, Regar E, van Geuns RJ, de Jaegere PJ, Serruys PW, Krestin GP, de Feyter PJ (2008) Comprehensive assessment of coronary artery stenoses: computed tomography coronary angiography versus conventional coronary angiography and correlation with fractional flow reserve in patients with stable angina. J Am Coll Cardiol 52:636–643CrossRefPubMed Meijboom WB, Van Mieghem CA, van Pelt N, Weustink A, Pugliese F, Mollet NR, Boersma E, Regar E, van Geuns RJ, de Jaegere PJ, Serruys PW, Krestin GP, de Feyter PJ (2008) Comprehensive assessment of coronary artery stenoses: computed tomography coronary angiography versus conventional coronary angiography and correlation with fractional flow reserve in patients with stable angina. J Am Coll Cardiol 52:636–643CrossRefPubMed
7.
go back to reference Nissen SE (2008) Limitations of computed tomography coronary angiography. J Am Coll Cardiol 52:2145–2147CrossRefPubMed Nissen SE (2008) Limitations of computed tomography coronary angiography. J Am Coll Cardiol 52:2145–2147CrossRefPubMed
8.
go back to reference Marwan M, Pflederer T, Schepis T, Seltmann M, Ropers D, Daniel WG, Achenbach S (2011) Coronary vessel and luminal area measurement using dual-source computed tomography in comparison with intravascular ultrasound: effect of window settings on measurement accuracy. J Comput Assist Tomogr 35:113–118CrossRefPubMed Marwan M, Pflederer T, Schepis T, Seltmann M, Ropers D, Daniel WG, Achenbach S (2011) Coronary vessel and luminal area measurement using dual-source computed tomography in comparison with intravascular ultrasound: effect of window settings on measurement accuracy. J Comput Assist Tomogr 35:113–118CrossRefPubMed
9.
go back to reference Komatsu S, Kamata T, Imai A, Ohara T, Miyaji K, Kobayashi Y, Kodama K (2014) Quantitative analysis of coronary vessels with optimized intracoronary ct number. Plos One 9:e85312CrossRefPubMedPubMedCentral Komatsu S, Kamata T, Imai A, Ohara T, Miyaji K, Kobayashi Y, Kodama K (2014) Quantitative analysis of coronary vessels with optimized intracoronary ct number. Plos One 9:e85312CrossRefPubMedPubMedCentral
10.
go back to reference Jiayin Z, Weimin H, Yanling C, Yuping D, Liang Z, Xiaodan Z, Junmei Z, Wei X, Ru San T, Kyaw Kyar T (2015) Quantification of coronary artery stenosis by area stenosis from cardiac ct angiography. Conf Proc IEEE Eng Med Biol Soc 2015:695–698 Jiayin Z, Weimin H, Yanling C, Yuping D, Liang Z, Xiaodan Z, Junmei Z, Wei X, Ru San T, Kyaw Kyar T (2015) Quantification of coronary artery stenosis by area stenosis from cardiac ct angiography. Conf Proc IEEE Eng Med Biol Soc 2015:695–698
11.
go back to reference Kruk M, Noll D, Achenbach S, Mintz GS, Pregowski J, Kaczmarska E, Kryczka K, Pracon R, Dzielinska Z, Sleszycka J, Witkowski A, Demkow M, Ruzyllo W, Kepka C (2014) Impact of coronary artery calcium characteristics on accuracy of ct angiography. JACC Cardiovasc Imaging 7:49–58CrossRefPubMed Kruk M, Noll D, Achenbach S, Mintz GS, Pregowski J, Kaczmarska E, Kryczka K, Pracon R, Dzielinska Z, Sleszycka J, Witkowski A, Demkow M, Ruzyllo W, Kepka C (2014) Impact of coronary artery calcium characteristics on accuracy of ct angiography. JACC Cardiovasc Imaging 7:49–58CrossRefPubMed
12.
go back to reference Fuchs A, Kuhl JT, Chen MY, Helqvist S, Razeto M, Arakita K, Steveson C, Arai AE, Kofoed KF (2015) Feasibility of coronary calcium and stent image subtraction using 320-detector row ct angiography. J Cardiovasc Comput Tomogr 9:393–398CrossRefPubMed Fuchs A, Kuhl JT, Chen MY, Helqvist S, Razeto M, Arakita K, Steveson C, Arai AE, Kofoed KF (2015) Feasibility of coronary calcium and stent image subtraction using 320-detector row ct angiography. J Cardiovasc Comput Tomogr 9:393–398CrossRefPubMed
13.
go back to reference Boone JM, Fewell TR, Jennings RJ (1997) Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. Med Phys 24:1863–1874CrossRefPubMed Boone JM, Fewell TR, Jennings RJ (1997) Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. Med Phys 24:1863–1874CrossRefPubMed
14.
go back to reference Boone JM, Seibert JA (1997) Accurate method for computer-generating tungsten anode X-ray spectra from 30 to 140 kv. Med Phys 24:1661–1670CrossRefPubMed Boone JM, Seibert JA (1997) Accurate method for computer-generating tungsten anode X-ray spectra from 30 to 140 kv. Med Phys 24:1661–1670CrossRefPubMed
15.
go back to reference Boone JM, Chavez AE (1996) Comparison of X-ray cross sections for diagnostic and therapeutic medical physics. Med Phys 23:1997–2005CrossRefPubMed Boone JM, Chavez AE (1996) Comparison of X-ray cross sections for diagnostic and therapeutic medical physics. Med Phys 23:1997–2005CrossRefPubMed
16.
17.
go back to reference Rasband WS (1997) 2005, Imagej. US National Institutes of Health, Bethesda, Maryland Rasband WS (1997) 2005, Imagej. US National Institutes of Health, Bethesda, Maryland
18.
go back to reference Leber AW, Knez A, von Ziegler F, Becker A, Nikolaou K, Paul S, Wintersperger B, Reiser M, Becker CR, Steinbeck G, Boekstegers P (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154CrossRefPubMed Leber AW, Knez A, von Ziegler F, Becker A, Nikolaou K, Paul S, Wintersperger B, Reiser M, Becker CR, Steinbeck G, Boekstegers P (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154CrossRefPubMed
19.
go back to reference Kim HJ, Vignon-Clementel IE, Coogan JS, Figueroa CA, Jansen KE, Taylor CA (2010) Patient-specific modeling of blood flow and pressure in human coronary arteries. Ann Biomed Eng 38:3195–3209CrossRefPubMed Kim HJ, Vignon-Clementel IE, Coogan JS, Figueroa CA, Jansen KE, Taylor CA (2010) Patient-specific modeling of blood flow and pressure in human coronary arteries. Ann Biomed Eng 38:3195–3209CrossRefPubMed
20.
go back to reference Koo BK, Erglis A, Doh JH, Daniels DV, Jegere S, Kim HS, Dunning A, DeFrance T, Lansky A, Leipsic J, Min JK (2011) Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter discover-flow (diagnosis of ischemia-causing stenoses obtained via noninvasive fractional flow reserve) study. J Am Coll Cardiol 58:1989–1997CrossRefPubMed Koo BK, Erglis A, Doh JH, Daniels DV, Jegere S, Kim HS, Dunning A, DeFrance T, Lansky A, Leipsic J, Min JK (2011) Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter discover-flow (diagnosis of ischemia-causing stenoses obtained via noninvasive fractional flow reserve) study. J Am Coll Cardiol 58:1989–1997CrossRefPubMed
21.
go back to reference Min JK, Leipsic J, Pencina MJ, Berman DS, Koo BK, van Mieghem C, Erglis A, Lin FY, Dunning AM, Apruzzese P, Budoff MJ, Cole JH, Jaffer FA, Leon MB, Malpeso J, Mancini GB, Park SJ, Schwartz RS, Shaw LJ, Mauri L (2012) Diagnostic accuracy of fractional flow reserve from anatomic ct angiography. JAMA 308:1237–1245CrossRefPubMedPubMedCentral Min JK, Leipsic J, Pencina MJ, Berman DS, Koo BK, van Mieghem C, Erglis A, Lin FY, Dunning AM, Apruzzese P, Budoff MJ, Cole JH, Jaffer FA, Leon MB, Malpeso J, Mancini GB, Park SJ, Schwartz RS, Shaw LJ, Mauri L (2012) Diagnostic accuracy of fractional flow reserve from anatomic ct angiography. JAMA 308:1237–1245CrossRefPubMedPubMedCentral
22.
go back to reference Huo Y, Svendsen M, Choy JS, Zhang ZD, Kassab GS (2012) A validated predictive model of coronary fractional flow reserve. J R Soc Interface 9:1325–1338CrossRefPubMed Huo Y, Svendsen M, Choy JS, Zhang ZD, Kassab GS (2012) A validated predictive model of coronary fractional flow reserve. J R Soc Interface 9:1325–1338CrossRefPubMed
Metadata
Title
Accurate quantification of vessel cross-sectional area using CT angiography: a simulation study
Authors
Sabee Molloi
Travis Johnson
Huanjun Ding
Jerry Lipinski
Publication date
01-03-2017
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 3/2017
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-016-1007-9

Other articles of this Issue 3/2017

The International Journal of Cardiovascular Imaging 3/2017 Go to the issue